MG·LX · 346 entries
Lexicon of medical imaging and AI
Terms of medical imaging and artificial intelligence used across the exhibits.
Image basics33
- aliasing When sampling is too sparse, a fine pattern appears as a coarse one. In MRI, anatomy outside the field of view wraps onto the opposite side; in Doppler ultrasound, fast flow appears to run backwards. Both are aliasing.
- artifact A feature in the image that is not present in the patient, produced by the physics, the equipment or motion. Artifacts can mimic disease or hide it, so recognising them is a basic reading skill.
- bit depth How many binary digits store each pixel, and so how many gray levels it can take: n bits give 2^n. CT uses 12 bits, 4,096 levels, enough for every CT number from air to bone; an ordinary screen shows 8 bits per channel.
- contrast The difference in signal between a structure and its surroundings. Whether a lesion can be seen depends first on how much it differs from normal tissue in the measured quantity; without contrast, resolution does not help.
- contrast-to-noise ratioCNR The signal difference between two tissues divided by the noise. It predicts whether a lesion can be seen better than contrast or SNR alone, and is the usual yardstick when comparing protocols or cutting dose.
- convolution Sliding a small grid of weights across an image and taking a weighted sum at every position. Blurring, sharpening and edge detection are convolutions, and so is the blur an imaging system adds; a CNN learns its own weights.
- dynamic range The ratio between the strongest and weakest signals a system can record or show at once. A detector's dynamic range decides how forgiving it is of exposure errors; a display's narrow range is why images are viewed through a window width & level setting.
- fast Fourier transformFFT 1965 An efficient algorithm for the discrete Fourier transform that cuts the work from N^2 to about N\log_2 N operations. Without it, MRI reconstruction and much image filtering could not run in seconds.
- filter kernel The small matrix of weights used in a convolution, which decides what the filter does: smooth, sharpen or find edges. In CT the choice of reconstruction kernel directly trades sharpness against noise.
- Fourier transform 1822 A mathematical tool that rewrites any signal or image as a sum of sine waves of different frequencies. MRI measures an image's Fourier transform directly, as k-space, and CT filtering happens in the same domain; it is a common mathematical basis of modern imaging methods.
- grayscale Showing one number at each point as a brightness between black and white. Most medical images measure a single physical quantity per point, so they are naturally grayscale; which tissue looks white depends on what was measured.
- histogram 1895 A bar chart counting how many pixels take each gray value. It ignores where the pixels are, yet shows at a glance how intensities are distributed: the starting point for choosing thresholds, adjusting contrast and normalising intensities.
- interpolation Estimating values between known samples. Resizing, rotating, reformatting (multiplanar reconstruction) and registering images all depend on it. Interpolation makes images smoother but never adds information that was not sampled.
- inverse problem Working backwards from indirect measurements to the object that produced them. Recovering a slice from CT projections, an image from MRI k-space, or a sharp image from a blurred one are all inverse problems, and most are highly sensitive to noise.
- isosurface An isosurface consists of locations in a three-dimensional scalar field that share a chosen value. In medical imaging, it can approximate the boundary of a structure.
- marching cubes 1987 The classic algorithm for pulling a triangle mesh out of 3D image data: visit each little cube of eight neighboring voxels and look up which triangles to draw. Published by Lorensen and Cline of General Electric in 1987, it is still the default for medical 3D models.
- maximum intensity projectionMIP 1989 Keeping only the brightest voxel along each line of sight, which collapses a 3D volume into one 2D image. Contrast-filled vessels or high-uptake lesions stand out from the background, at the cost of all depth information.
- multiplanar reconstructionMPR Re-slicing a stack of axial images into coronal, sagittal, oblique or even curved planes. It frees the reader from the direction the scan was acquired in, provided the voxels are thin and close to isotropic.
- noise Random fluctuation added to the true signal, which makes uniform tissue look grainy. In X-ray and nuclear imaging it comes mainly from counting a finite number of photons, so lower dose means coarser grain.
- Nyquist–Shannon sampling theorem 1949 To capture a signal without loss, sample at more than twice its highest frequency. For images, that means at least two samples across the finest light–dark cycle; otherwise fine detail appears as a spurious coarse pattern, which is aliasing.
- pixel 1957 The smallest element of a digital image: a single number standing for a measured quantity over one small patch of the body. Smaller pixels can show finer detail, but each one collects less signal.
- point spread functionPSF The image a system makes of a single ideal point: the blur spot a point is smeared into. It sums up how blurry the system is; the narrower the spot, the better the spatial resolution.
- projection The sum of everything a ray passes through, recorded as one reading at the detector. A radiograph is a single projection, with front and back flattened into one plane; CT gathers projections from many angles and computes the slice.
- quantization Rounding a continuous measurement to one of a finite set of levels, for instance storing CT numbers as 12-bit integers. Too few levels turn smooth gradients into visible steps and erase subtle differences.
- sampling Reading a continuous signal at discrete positions or moments, the first step in turning the physical world into a digital image. The sampling interval sets the finest detail that survives; sample too sparsely and aliasing appears.
- signal-to-noise ratioSNR 1948 The ratio of signal strength to noise, a measure of how clean an image is. Low SNR buries detail in grain; raising it costs more photons, a stronger magnet or more scan time.
- spatial frequency How rapidly brightness varies across space, in cycles or line pairs per millimeter. Low frequencies carry overall shape and shading; high frequencies carry edges and fine detail, and most of the noise.
- spatial resolution How close two small objects can be and still appear separate. Measured in line pairs per millimeter or as the width of the point spread function, it depends on detector, focal spot, motion and reconstruction, not on pixel size alone.
- surface rendering 1979 Extracting the boundary of a structure from 3D data as a surface, then lighting it like any computer-graphics model. The mesh can go straight into surgical planning or a 3D printer, but only the surface is shown, not what lies inside.
- temporal resolution The time needed to capture one image, which decides whether motion can be frozen. The heart, blood and breathing never stop; if acquisition is too slow, they blur or leave motion artifacts.
- tomography 1921 Imaging a single thin slice of the body without the structures in front and behind piling on top of it; from the Greek tomos, a slice. CT, MRI, PET and SPECT are all tomographic, and all escape the superposition that limits a plain radiograph.
- volume rendering 1988 A 3D display that renders a whole volume directly, without extracting surfaces: each voxel gets a color and an opacity, and rays accumulate them on their way through. Bone, vessels and soft tissue can be shown together in their true spatial relation.
- voxel The 3D counterpart of a pixel: a small box of tissue represented by one number. Every value in a CT or MRI volume is an average over its voxel, so large voxels blend different tissues together.
Physics41
- acoustic impedance Density times sound speed, Z = ρc. How much ultrasound reflects at a boundary depends on the impedance difference across it: about 1% between soft tissues, nearly all at a tissue–air interface. Hence the gel under the probe, and why lungs and bowel gas are difficult to image through.
- ALARA 1977 "As low as reasonably achievable": keep radiation dose as low as practical while still answering the clinical question. It is why CT settings are tailored to body size and to children, and why the goal is a diagnostic image, not the prettiest one.
- annihilation When a positron meets an electron, both vanish and their mass becomes two gamma photons of 511 keV each, flying off almost exactly back to back. A PET scanner detects both at once on its detector ring, which locates the event on the line joining them.
- anti-scatter grid An anti-scatter grid sits between the patient and the detector. It transmits much of the primary X-ray beam and absorbs some obliquely traveling scatter, improving image contrast.
- attenuation The weakening of a beam, X-ray or ultrasound, as tissue absorbs and scatters it. Radiographs and CT images record attenuation directly; ultrasound and PET must compensate for it to image deep structures.
- attenuation coefficient How strongly a material weakens a beam per unit thickness, written μ and measured per centimeter. It depends on composition and photon energy; CT reconstructs μ for every voxel and reports it in Hounsfield units.
- Beer–Lambert law A beam crossing uniform material fades exponentially: I = I_0 e^{-\mu x}. Taking the logarithm turns each measured intensity into a sum of attenuation coefficients along the ray, which is what lets CT solve for the inside of the body.
- bremsstrahlung 1909 X-rays emitted when a fast electron is sharply decelerated by the electric field of a nucleus; the German word means "braking radiation". It produces most of the X-rays in an X-ray tube, as a continuous spectrum up to the tube voltage.
- collimator A lead plate full of narrow holes in front of a detector that admits only photons traveling in one direction, so their origin is known — at the cost of stopping most of them.
- Compton scattering 1923 An X- or gamma-ray photon bounces off a loosely bound electron, losing part of its energy and changing direction. It dominates in soft tissue at most diagnostic energies, says little about composition, fogs images, and is the main source of staff exposure.
- CT dose indexCTDI The CT dose index characterizes scanner radiation output under standardized measurement conditions. The commonly reported volume index, CTDIvol, is expressed in milligrays and can be used to compare protocols.
- Doppler effect 1842 When a wave source and receiver move relative to each other, the received frequency shifts: higher when approaching, lower when receding. Ultrasound measures this shift in echoes from moving red blood cells to map the speed and direction of flow, the basis of Doppler ultrasound.
- electromagnetic spectrum 1865 All electromagnetic radiation laid out by wavelength or photon energy, from radio waves to gamma rays. Imaging uses several bands: radio frequencies for MRI, near-infrared light for OCT, and X-rays and gamma rays at the energetic end.
- FDG 1976 A glucose analogue labeled with fluorine-18, and the most widely used PET tracer. Cells take it up like glucose but cannot metabolize it further, so it accumulates wherever glucose use is high; most cancers burn glucose avidly and light up on FDG PET.
- frequency encodingFE MRI frequency encoding uses a magnetic field gradient during signal reception, so spins at different positions precess at different frequencies. The measured frequencies therefore help locate the sources of the signal.
- gamma ray 1900 A high-energy photon emitted by an atomic nucleus. It is physically the same as an X-ray; the name reflects origin, not energy. Nuclear medicine images the gamma rays leaving a radiotracer inside the body: 140 keV from technetium-99m, 511 keV in PET.
- gradient coil 1973 Three sets of coils that make the MRI field vary linearly along x, y and z. Because resonance frequency follows field strength, each position gets its own frequency, which is how MRI determines where signal comes from. Their rapid switching causes the scanner's loud knocking.
- half-life The time for half of a radioactive nuclide's atoms to decay. It decides how long a radiotracer can be used and how long the patient stays radioactive: about 6 hours for technetium-99m, 110 minutes for the fluorine-18 used in PET, which must be made not far from the scanner.
- ionizing radiation Radiation energetic enough to strip electrons from atoms: X-rays, gamma rays, alpha and beta particles. Because it can break DNA, every X-ray, CT and nuclear medicine exam weighs dose against benefit; MRI and ultrasound do not ionize.
- k-space 1983 The spatial-frequency domain where MRI raw data live. The scanner measures the Fourier transform of the image, and an inverse transform turns it into a picture. The center carries overall contrast, the edges carry fine detail, and how much of it is sampled sets the scan time.
- Larmor frequency 1897 The rate at which nuclear spins precess about a magnetic field, proportional to field strength: 42.58 MHz per tesla for hydrogen, about 64 MHz at 1.5 T. Only an RF pulse at this frequency excites the protons, and making it vary with position is how MRI locates signal.
- nuclear magnetic resonanceNMR 1946 Nuclei in a magnetic field absorb radio waves at a precise frequency and then re-emit a signal. First a tool of physics and chemistry, it became an imaging method in the 1970s as MRI, which dropped the word "nuclear" to reassure patients.
- nuclear spin 1924 The intrinsic angular momentum of certain nuclei, such as the hydrogen proton, which makes each act like a tiny bar magnet. In a strong field slightly more of the body's hydrogen nuclei align with the field than against it, and that tiny net magnetization is the signal MRI measures.
- phase encodingPE In MRI, phase encoding uses a temporary magnetic field gradient to create position-dependent phase shifts. Varying the time integral of the gradient allows the scanner to collect distinct spatial measurements.
- photoelectric effect 1905 A photon gives all its energy to an inner-shell electron and vanishes. Its probability scales roughly as Z^3/E^3, so calcium and iodine stand out sharply at low X-ray energies; this is the main source of contrast in X-ray images.
- piezoelectric effect 1880 Some crystals produce a voltage when squeezed and change shape when a voltage is applied. An ultrasound transducer uses both directions: an electrical pulse makes it ring and send sound into the body, and returning echoes squeeze it back into electrical signals.
- positron 1932 The antiparticle of the electron: same mass, positive charge. Proton-rich nuclides such as fluorine-18 emit positrons as they decay; each travels at most a few millimeters in tissue before it meets an electron and annihilates into two gamma photons, the signal PET detects.
- proton densityPD The number of MRI-visible hydrogen nuclei per unit volume of tissue. It sets the ceiling on a voxel's signal. Proton-density-weighted images show little contrast between most soft tissues but are widely used for cartilage and menisci in joint imaging.
- pulse–echo principle Send a short pulse of sound, time the echo, and convert that time to depth using the speed of sound. All ultrasound imaging imaging rests on this: in soft tissue sound travels about 1540 m/s, so every 13 μs of delay means one more centimeter of depth.
- radiation dose How much energy ionizing radiation deposits in the body, and what that means for health. Absorbed dose is measured in grays; weighting by organ sensitivity gives the effective dose in sieverts, the common yardstick for comparing examinations.
- radiotracer 1923 A molecule tagged with a radioactive atom, given in amounts far too small to disturb the body yet detectable from outside. It follows a particular organ or metabolic pathway, so a nuclear medicine image maps function, where the tracer went, rather than anatomy.
- RF pulse A brief burst of radio waves at the Larmor frequency that tips the protons' net magnetization away from the main field by a chosen flip angle. Every MRI excitation and spin echo starts with one; the heat it deposits is a main MRI safety limit.
- scintillator 1948 A material that converts an absorbed X- or gamma-ray photon into a brief flash of visible light, which a photomultiplier or silicon photodetector turns into an electrical signal. Gamma cameras, PET, CT and many flat-panel X-ray detectors all rely on one.
- sievertSv 1979 The unit of radiation dose weighted for biological harm: 1 Sv is 1 J/kg after weighting for radiation type and organ. Imaging doses are quoted in millisieverts: about 0.1 mSv for a chest X-ray, about 6 mSv for a chest CT.
- spin echoSE A spin echo is a renewed magnetic resonance signal produced by refocusing spins whose phases spread because of static differences in magnetic field. It appears at a predictable time after excitation.
- T1 relaxation 1946 After an RF pulse, the protons' magnetization regrows along the main field with time constant T1. Fat recovers fast and water slowly, so on T1-weighted images fat is bright and fluid dark; gadolinium-based contrast agent shortens T1 and makes enhancing lesions light up.
- T2 relaxation 1946 After excitation, the transverse magnetization fades as protons fall out of step with one another, with time constant T2, typically tens of milliseconds and always shorter than T1. Fluid keeps its T2 longest, so edema and effusions appear bright on T2-weighted images, where many lesions first show.
- technetium-99mTc-99m Technetium-99m is a metastable radionuclide used in single-photon imaging. Its gamma radiation can be detected outside the body, and different technetium-labeled compounds can show different physiological processes.
- teslaT 1960 The SI unit of magnetic flux density, named after Nikola Tesla. Earth's field is about 50 μT; clinical MRI scanners run at 1.5 or 3 T, tens of thousands of times stronger. Higher fields give more signal, along with more artifacts, heating and cost.
- X-ray 1895 High-energy electromagnetic radiation, wavelength about 0.01–10 nm, that passes through the body but is attenuated differently by bone, soft tissue and air. Discovered by Röntgen in 1895, it is the basis of radiography and CT.
- X-ray tube 1913 The vacuum tube that makes medical X-rays: electrons from a hot filament are accelerated through tens of kilovolts into a tungsten target, where about 1% of their energy becomes X-rays and the rest heat. Voltage sets photon energy; current × time sets how many.
Modalities53
- A-mode The simplest ultrasound imaging display: echo strength plotted as spikes against depth along a single beam (A for amplitude). It makes no picture, but it measures distance precisely, and is still used to measure the length of the eye.
- angiography 1927 Making blood vessels visible by filling them with an iodinated contrast agent and imaging with X-rays. It maps narrowed coronary arteries, aneurysms and bleeding points, and the same catheter can then deliver the treatment.
- B-mode The familiar gray ultrasound imaging picture: each echo's strength becomes pixel brightness (B for brightness), and scan lines laid side by side form a two-dimensional slice, refreshed dozens of times a second.
- BOLD signalBOLD 1990 Deoxygenated hemoglobin is paramagnetic and makes nearby MR signal fade faster. When a brain region becomes active, blood flow overshoots demand, deoxyhaemoglobin is washed out and the signal rises slightly. This is the contrast functional MRI relies on.
- computed radiographyCR 1983 Radiography on a reusable imaging plate instead of film. A storage phosphor holds the X-ray pattern as trapped electrons until a scanning laser releases it as light, point by point, into a digital image. It let hospitals go digital without replacing their X-ray rooms.
- computed tomographyCT 1971 An X-ray tube and detector rotate around the body, measuring projections from hundreds of angles; a computer then calculates the attenuation at every point of a cross-section. It gave medicine its first overlap-free slices through the living body and remains the principal modality in emergency and cancer imaging.
- cone-beam CTCBCT CT with a cone-shaped X-ray beam and a flat-panel detector that captures a whole volume in a single rotation. Compact and low-dose, it is used in dentistry, radiotherapy positioning and on the interventional table, though its soft-tissue contrast falls short of conventional CT.
- contrast agent A substance introduced into the body to make otherwise invisible structures show: iodine or barium raise X-ray attenuation, gadolinium-based contrast agent shortens MRI relaxation times, and microbubbles brighten ultrasound echoes. A contrast-enhanced scan is one done with an injected agent.
- CT colonographyCTC CT colonography uses CT data from a distended colon to produce cross-sectional and internal views. The images allow readers to look for polyps and other findings along the bowel wall.
- dermoscopy A hand-held magnifier, usually 10×, that removes glare from the skin surface so the pigment patterns and vessels beneath become visible. It improves the recognition of melanoma, and dermoscopic images are the main training data for skin-lesion AI.
- diffusion MRIDWI 1985 MRI made sensitive to the random motion of water molecules: the further water molecules diffuse during the measurement, the more signal is lost. Where cells swell and diffusion is restricted, as in an acute stroke, tissue appears bright long before CT shows anything.
- diffusion tensor imagingDTI 1994 Diffusion MRI measured in at least six directions and summarized in each voxel by a 3×3 tensor that describes the direction in which water diffuses most easily. In white matter that direction follows the nerve fibers, so DTI reveals a fiber orientation that ordinary MRI does not show.
- digital pathology Scanning glass pathology slides into high-resolution whole-slide images so they can be read on screen, archived and shared. It turned pathology into a digital discipline and made it accessible to computational analysis and AI.
- digital radiographyDR Radiography captured directly by an electronic detector, usually a flat-panel detector, with the image on screen within seconds and no film or plate to process. It is now the usual way chest and bone X-rays are taken, and the source of the digital archives imaging AI is trained on.
- digital subtraction angiographyDSA 1980 A mask image is taken before contrast and further images as the contrast flows in; subtracting the mask cancels bone and soft tissue, leaving only the opacified vessels. Vascular detail becomes stark, but any movement between frames leaves misregistration artifacts.
- Doppler ultrasound 1957 Ultrasound that measures blood flow through the Doppler effect: echoes from blood cells moving towards the probe return at a higher frequency, those moving away at a lower one. Colour Doppler paints speed and direction in red and blue over the B-mode image.
- dual-energy CTDECT 1976 Scanning the same anatomy with two X-ray spectra. Because elements attenuate differently as energy changes, comparing the two data sets separates iodine, calcium, uric acid and other materials, producing iodine maps and virtual non-contrast images that ordinary CT cannot.
- echo-planar imagingEPI 1977 A way to read an entire MR image after a single excitation, switching the gradients back and forth so the echo train sweeps all of k-space in tens of milliseconds. It is the standard acquisition method for functional MRI and diffusion MRI, at the cost of geometric distortion.
- elastography 1991 Imaging that measures how stiff tissue is, quantifying what a doctor assesses by palpation. Tumours and fibrotic tissue are usually stiffer than their surroundings, so it is widely used to assess liver fibrosis without a biopsy and to characterize breast and thyroid lumps.
- endoscopy 1806 A flexible or rigid tube with a light and camera passed into the gut, airway or another body cavity, giving live color video of the lining. It diagnoses and treats in one session, from biopsies to polyp removal, and its real-time video suits AI that flags lesions as they appear.
- flat-panel detectorFPD A thin detector the size of a film cassette, with millions of pixels on a thin-film-transistor array, that reads X-rays out directly as a digital image. It replaced film and image intensifiers in digital radiography, mammography, fluoroscopy and cone-beam CT.
- fluoroscopy 1896 Real-time X-ray imaging: a continuous stream of low-dose frames that shows swallowed barium, a beating heart or a catheter being steered. Interventional procedures depend on it; the price is a dose that keeps adding up for as long as the beam is on.
- functional MRIfMRI 1992 Rapid, repeated MRI of the brain that tracks the local change in blood oxygenation (the BOLD signal signal) that follows neural activity, producing maps of which regions are active. It measures a blood-flow response, not the firing of neurons itself.
- fundus photography 1886 A color photograph of the retina taken through the pupil, showing the optic disc, macula and blood vessels. Quick, cheap and non-invasive, it is the standard tool for diabetic-retinopathy screening and the image behind the first FDA-authorized autonomous AI diagnosis.
- gadolinium-based contrast agentGBCA 1988 The standard MRI contrast agent. The gadolinium ion's seven unpaired electrons sharply shorten the T1 of nearby water, so tissue with a rich blood supply or a broken blood–brain barrier lights up on T1-weighted images. Toxic when free, the ion is locked inside a chelating molecule.
- gamma camera 1957 The standard detector of nuclear medicine. A lead collimator admits only gamma rays traveling straight in, a large scintillator crystal turns each into a flash of light, and an array of photomultiplier tubes works out where it landed, building a flat map of the tracer.
- helical CT 1989 The table moves steadily while the X-ray tube spins continuously, so the beam traces a helix through the patient and a whole body region is captured as a volume in one breath-hold. It turned computed tomography from slice-by-slice imaging into true 3D imaging.
- histopathology The study of tissue under the microscope: specimens are fixed, cut into sections a few micrometres thick and stained to show cells and their arrangement. It is the reference for diagnosing most cancers, and often the ground truth against which imaging AI is judged.
- low-dose CTLDCT CT run at deliberately reduced tube current or voltage, cutting dose to a fraction of a standard scan at the cost of more image noise. In 2011 a US trial of 53,454 heavy smokers showed that screening with it lowered lung-cancer deaths by 20%.
- low-field MRI MRI at fields well below the clinical 1.5 T, down to a few tens of millitesla. Signal is weaker and images coarser, but the magnet can be cheap, light and permanent, so the scanner can be wheeled to the bedside or installed where no conventional MRI exists.
- M-mode ultrasound M-mode ultrasound repeatedly samples echoes along a single beam direction and plots depth against time. The display records motion along that beam, such as the movement of a heart valve.
- magnetic resonance imagingMRI 1973 Imaging with a strong magnet, radio pulses and field gradients: hydrogen nuclei in the body's water and fat emit a faint radio signal, and the gradients encode where it came from. No ionizing radiation, and far better soft-tissue contrast than CT.
- mammography 1913 Low-energy X-ray imaging of the compressed breast, designed to show small masses and specks of calcium a fraction of a millimeter across. It is the principal method of breast-cancer screening and one of the first places computer-aided reading reached the clinic.
- multidetector CTMDCT 1998 CT with many detector rows side by side along the table axis, so each rotation captures several slices at once. The jump from 4 slices in 1998 to 64 around 2004 made sub-millimeter whole-body scans and coronary CT angiography routine.
- nuclear medicine The medical use of tiny amounts of radioactive tracers: the tracer is injected and its radiation detected from outside the body to show where it goes and how much collects. It shows function and metabolism rather than shape alone; positron emission tomography and single-photon emission computed tomography belong to it.
- optical coherence tomographyOCT 1991 An imaging method analogous to ultrasound but using light instead of sound: near-infrared light reflected from different depths in tissue is measured by interferometry, giving cross-sections with micrometre resolution. It lets ophthalmologists see the retina layer by layer and is a routine test in macular disease.
- PET/CT 1998 A positron emission tomography scanner and a computed tomography scanner in one gantry, so a single visit yields both scans already aligned. PET shows where metabolism is abnormal, CT shows exactly where that is, and the CT data also correct the PET image for attenuation.
- PET/MR 2011 positron emission tomography detectors built into an magnetic resonance imaging scanner so both run at once. It pairs metabolic imaging with MRI's superior soft-tissue contrast and avoids CT's radiation, but the machines are expensive and correcting for attenuation is harder.
- photon-counting CTPCCT 2021 CT whose detector counts individual X-ray photons and measures each one's energy, instead of integrating all the energy into one signal. It gives sharper images with almost no electronic noise and spectral information in every scan. The first clinical system was cleared by the FDA in 2021.
- point-of-care ultrasoundPOCUS Ultrasound performed at the bedside by the treating clinician, in emergency, intensive care or general practice, to answer one focused question, such as whether there is blood in the abdomen or air around a lung. Handheld devices take it almost anywhere.
- positron emission tomographyPET 1975 Imaging a positron-emitting tracer, most often FDG, by detecting the pair of 511 keV photons that fly apart when each positron annihilates. The result is a 3D map of metabolic activity, central to staging cancer.
- radiographic film Silver-halide film that recorded radiographs for most of the 20th century, usually exposed between two fluorescent intensifying screens. One sheet captured, displayed and archived the image at once, but its narrow exposure latitude left no way to rescue a bad exposure.
- radiography 1895 Imaging by sending X-rays through the body and recording what emerges on the other side. The result is a projection: bone absorbs strongly and shows white, air-filled lung hardly at all and shows black. The oldest and commonest exam, but it flattens everything along each ray together.
- single-photon emission computed tomographySPECT 1963 A gamma camera rotated around the patient, recording the tracer from dozens of angles, with slices reconstructed much as in CT. It took nuclear medicine from flat pictures into three dimensions and is used above all to image blood flow to the heart muscle.
- standardized uptake valueSUV The everyday number of positron emission tomography reading: tracer concentration in a region divided by the concentration if the injected dose were spread evenly through the body. An SUV of 1 means average uptake; tumors often reach several times that, and changes track response to treatment.
- time-of-flight PETTOF-PET positron emission tomography that times the arrival of each photon pair to within a few hundred picoseconds, narrowing where along the line of response the annihilation happened. Better timing means less noise, which can be traded for shorter scans or lower doses.
- tomosynthesis 1972 The X-ray tube sweeps through a limited arc, taking a dozen or more low-dose projections that are reconstructed into a stack of parallel slices. Somewhere between a radiograph and computed tomography, it is used mainly in the breast, letting readers scroll slice by slice through tissue that would otherwise overlap.
- total-body PET positron emission tomography with a detector ring long enough to cover the whole body at once, about two meters. Conventional scanners cover 15–30 cm at a time; collecting photons from everywhere simultaneously raises effective sensitivity dozens of times, allowing faster scans, lower doses or whole-body dynamic imaging.
- tractography 1999 Following the fiber direction estimated by diffusion tensor imaging or other diffusion models from voxel to voxel, joining it into three-dimensional white-matter pathways. It made the brain's white-matter connections visible in living people, but the streamlines are inferences, not dissected anatomy.
- transducer The hand-held probe of an ultrasound imaging scanner. Its piezoelectric elements turn electrical pulses into sound and returning echoes back into voltage; a modern probe lines up a hundred or more of them, which fixes the image's frequency, field of view and shape.
- ultra-high-field MRI MRI at 7 tesla or more. The extra signal resolves sub-millimeter detail such as cortical layers and tiny lesions, but shorter radio wavelengths and greater tissue heating make uniform images and safe scanning harder.
- ultrasound imagingUS 1942 Imaging with sound pitched far above human hearing: a probe sends short pulses and times the returning echoes to find depth. Cheap, free of ionizing radiation and real-time, it is one of the most widely used imaging tests in the world, though highly operator-dependent.
- whole-slide imageWSI A digital scan of an entire pathology glass slide, often billions of pixels at the resolution of a 40× objective. Far too large to feed whole into a neural network, it is processed as thousands of tiles, which shaped methods such as multiple-instance learning.
Reconstruction20
- attenuation correction Attenuation correction accounts for photons lost before detection in emission imaging. It uses an estimate of tissue attenuation to reduce bias in the reconstructed distribution of tracer activity.
- back-projection Reconstruction's intuitive step: smear each measured projection back across the image along the rays it came from, then add up all the angles. On its own it gives a blurred image; filtering first is what makes it sharp.
- beamforming 1968 How an ultrasound imaging array focuses electronically: delay the echo received by each element so that signals from one chosen point line up, then add them. That point is reinforced, and echoes from elsewhere partly cancel.
- compressed sensingCS 2006 If an image is sparse in some transform, it can be recovered from far fewer, randomly placed samples than Nyquist demands. Applied to MRI, it skips much of k-space and cuts scan times several-fold.
- data consistencyDC Data consistency makes a reconstructed image agree with the acquired measurements when passed through a model of the scanner. Agreement can be enforced exactly or weighted to account for noise.
- deep unrolling Deep unrolling turns a chosen number of iterations of an algorithm into stages of a trainable network. It can retain a measurement model while learning parts of the update from data.
- deep-learning reconstructionDLR 2019 Using a trained neural network to turn raw data into images, or to replace the hand-designed noise models and priors in that process. It yields clean images at lower dose or shorter scan times, but can also introduce structures that are not there.
- denoising Removing random noise from an image while keeping its real structure. In medical imaging it decides how far dose or scan time can be cut, since both trade directly against noise.
- filtered back-projectionFBP 1967 The classic CT reconstruction: sharpen each projection with a ramp filter, then back-project. One pass gives a sharp slice, which is why it was the standard way to make CT images for some four decades.
- Hounsfield unitHU The number stored in each CT voxel: tissue attenuation rescaled so that water is 0 and air is −1000. Fat sits near −100 and dense bone above +1000, which makes CT images quantitative, not just pictures.
- iterative reconstructionIR 1970 Reconstruction by repeated correction: guess an image, simulate the scan, compare with the measured data, adjust, repeat. Because the model can include the physics and the noise statistics, it gives cleaner images than filtered back-projection at the same dose.
- material decomposition Material decomposition uses measurements from different X-ray spectra to estimate equivalent amounts of selected basis materials. It can distinguish contributions that have similar attenuation in a conventional CT image.
- metal artifact reductionMAR Metal artifact reduction changes acquisition or reconstruction to reduce streaks and distorted intensities caused by metal. In CT it is used to improve the visibility of tissue near implants.
- ordered-subsets expectation maximizationOSEM Ordered-subsets expectation maximization is a statistical reconstruction method that divides projections into groups and updates the image after each group, accelerating the early stages of emission tomography reconstruction.
- parallel imaging 1997 An MRI speed-up that skips lines of k-space and uses an array of receive coils with different spatial sensitivities to unfold the resulting overlap. Accelerations of two to three are routine.
- Radon transform 1917 The operation that turns an image into its integrals along every straight line, that is, its projections at all angles. Johann Radon showed in 1917 that it can be inverted exactly, which is why CT can recover a slice from projections.
- ramp filter 1971 The filter applied to each projection in filtered back-projection. Its gain rises in proportion to spatial frequency, |\omega|, cancelling the blur of back-projection and amplifying high-frequency noise along the way.
- sinogram The raw data of a CT scan: every projection stacked row by row, one row per angle. Each point in the body traces a sine curve through it, hence the name; the cross-sectional image is reconstructed from it.
- super-resolutionSR 1984 Computing a higher-resolution image from lower-resolution data. It can sharpen thick-slice or low-field MRI, but some of the added detail is inferred by the algorithm rather than measured.
- window width & level The rule that maps CT numbers to screen gray: the level sets the center, the width sets the range, and everything outside is pure black or pure white. The same data show lung texture in one window and gray–white matter in another.
Image analysis25
- active contour (snake) 1988 A closed curve that moves on its own: internal forces keep it smooth, image forces pull it toward edges, and at minimum energy it settles on an organ's outline. Introduced by Kass, Witkin, and Terzopoulos in 1988.
- active shape modelASM 1995 A model that first learns from annotated examples how an organ's shape is allowed to vary, then deforms only within that range to fit a new image. Introduced by Cootes, Taylor, and colleagues in Manchester in 1995.
- atlas-based segmentation Segmenting a new scan by registering an expert-labeled reference image, the atlas, onto it and carrying the labels along with the deformation. For years it was the standard way to outline brain structures and radiotherapy organs at risk.
- computer-aided detection & diagnosisCAD Software that marks suspicious findings on a scan (detection, CADe) or estimates how likely they are to be malignant (diagnosis, CADx), acting as a second reader for the radiologist. The first mammography CAD system won FDA approval in 1998.
- edge detection Locating where intensity changes abruptly, which is usually where an organ or lesion ends. Classic detectors compute gradients with small kernels; Canny's 1986 detector remains the standard reference.
- graph cut 2001 Treating the image as a network in which pixels are nodes and similar neighbors are joined by strong links, then finding the cheapest cut that separates object from background. The optimum is global, and from 2001 the method powered interactive segmentation.
- hand-crafted features Image descriptors designed by people from experience: intensity statistics, shape, texture, SIFT, and HOG. Before 2012 most medical image analysis paired such features with a classifier; deep learning changed that by learning features from the data.
- image classification Assigning one label to a whole image: diabetic retinopathy or not, benign or malignant, normal or abnormal. Deep learning first broke through in medical imaging on this kind of task, though on its own a classifier does not say where the finding is.
- image registration Finding the spatial transformation that brings two images into one coordinate frame: scans of a patient taken at different times or on different machines, or a patient and a reference atlas. Image fusion, follow-up comparison, and radiotherapy planning all depend on it.
- image segmentation Labeling every voxel of a scan with what it belongs to (liver, tumor, background) to produce a mask. Organ volumes, tumor measurements, radiotherapy contours, and 3D-printed models all start from a segmentation.
- instance segmentation Instance segmentation assigns a separate mask to each individual object, including objects of the same class. This makes it possible to measure or count them separately.
- level set method 1988 Representing a contour as the zero level of a higher-dimensional function and evolving the whole function, so the contour can split and merge freely. It removed the topological limits of snakes and extends naturally to 3D segmentation.
- multi-atlas segmentation Registering a dozen or more labeled atlases to the same new scan and fusing their labels by voting or weighting. Errors from any single registration average out, and before deep learning it was among the most accurate segmentation methods.
- multi-organ segmentation Multi-organ segmentation delineates several organs in the same medical scan. It provides a separate region for each organ so its shape and volume can be measured and spatial relationships between organs can be analyzed.
- mutual informationMI A measure of how much information one image's intensities carry about another's, without requiring them to match. That makes it the standard similarity measure for multimodal image registration of CT, MRI, and PET, whose brightness rules are entirely different.
- object detection Finding each object of interest in an image, drawing a box around it, and giving it a class and a confidence score. Lung-nodule, breast-mass, and polyp finders are detectors, judged by their sensitivity at a given number of false positives per scan.
- phrase grounding Phrase grounding identifies the region in a specified image that corresponds to a text description. The result can be a heat map, bounding box, or region mask.
- radiomics 2012 Extracting hundreds of quantitative shape, intensity, and texture features from a lesion on CT, MRI, or PET, then using statistics or machine learning to predict subtype, treatment response, or survival. It treats images as data.
- region growing Starting from a seed point, neighboring pixels with similar intensity are added ring by ring until a boundary stops the growth. It suits connected structures such as vessels and airways, but leaks wherever the boundary is weak.
- resting-state functional connectivityrsFC Resting-state functional connectivity measures how strongly signals from brain regions fluctuate together when the participant performs no prescribed task. It can be used to identify functional networks.
- spatial transcriptomicsST Spatial transcriptomics measures RNA while retaining information about its location in tissue. It allows patterns of gene expression to be examined in relation to tissue structure.
- stain normalization Stain normalization adjusts the colors or estimated stain concentrations in digitized tissue slides to reduce variation introduced by slide preparation, staining, and scanning across specimens.
- texture analysis Describing with numbers how gray levels are arranged in space: coarse or fine, uniform or mottled, directional or not. It turns the visual texture of tissue into comparable features and forms the core of radiomics.
- three-dimensional surgical planning Three-dimensional surgical planning uses a patient-specific anatomical model to define a proposed operation before surgery. The model can help compare approaches, cut locations, or implant positions.
- thresholding The simplest segmentation: pixels brighter than a cut-off become the object, the rest background. On CT, bone, air, and soft tissue sit far apart on the Hounsfield scale, so a single threshold often isolates bone or lung.
Machine learning81
- 3D U-Net 2016 U-Net rebuilt in three dimensions: every 2D convolution, pooling, and upsampling step becomes its 3D counterpart, so the network segments whole CT, MRI, or microscopy volumes voxel by voxel, and can learn from only a few annotated slices.
- active learning Active learning selects examples to label and uses the acquired labels to train a model. Selection can use the current model’s uncertainty or differences between available examples.
- Adam optimizer Adam is an optimization algorithm that tracks exponential moving averages of the gradient and its square for each parameter and uses them to determine the update direction and size.
- AI agent An AI system that uses a large language model as its controller to plan steps and call tools until a multistep task is done. In imaging it can chain segmentation, detection, and reporting models to answer a complex clinical question.
- AlexNet 2012 The deep convolutional network that won the 2012 ImageNet challenge with a top-5 error of 15.3% against the runner-up's 26.2%, trained on two gaming graphics cards. It turned computer vision, and soon medical imaging, towards deep learning.
- annotation Experts adding labels to medical images: boxes around lesions, voxel-by-voxel organ outlines, or a diagnosis for the whole image. It is the raw material of supervised learning, and the slowest, most expensive step in medical AI.
- atrous convolution Atrous convolution spaces out the input locations sampled by a kernel. It increases the receptive field with the same number of weights and without increasing the output stride.
- attention gate An attention gate learns how strongly to transmit features using information from the features themselves and from a contextual signal, for example when a segmentation model sends encoder features through a skip connection.
- autoencoder 2006 A network that squeezes its input into a few numbers and rebuilds the input from them, trained only to make the copy faithful. It needs no labels; in medical imaging it is used for denoising, compact features, and spotting anomalies through reconstruction error.
- backpropagationBP 1986 The algorithm that trains neural networks. Starting from the error at the output, it uses the chain rule to work backwards layer by layer, computing how much each weight should change. Every deep network, from U-Net to today's large models, is trained this way.
- batch normalizationBN Batch normalization standardizes features using the mean and variance estimated from a training minibatch, then applies a learned scale and offset to each normalized feature.
- Bayesian neural networkBNN A Bayesian neural network represents unknown weights with probability distributions. Observed training data update the distributions, and predictions combine the outputs obtained under different plausible weights.
- boosting 1995 Chaining many weak classifiers, each only slightly better than guessing, so that every new one concentrates on the examples its predecessors got wrong. AdaBoost and gradient-boosted trees are the best-known forms; both were widely used to detect organs and anatomical landmarks.
- clinical natural language processing Clinical natural language processing uses rules or learned models to analyze clinical text. It can extract findings and record information about negation, timing, and relationships.
- CLIP 2021 A 2021 OpenAI model that learns from images paired with their captions, pulling each image and its own text together in a shared space. It can recognize images from a sentence with no task-specific training, and it underlies many medical vision–language models.
- continual learningCL Continual learning updates a model as data, tasks, or classes become available over time. It also assesses whether the updated model retains capabilities acquired during earlier stages.
- contrastive learning 2020 A way to learn image features without labels: two altered views of the same image are pulled together and views of different images are pushed apart. The model learns what makes things alike, then adapts to a medical task with few annotations.
- convolutional neural networkCNN 1989 A neural network whose layers slide small learnable filters across the image, reusing the same weights everywhere. Since 2012 it has been the basic building block for classifying, detecting, and segmenting medical images.
- cycle consistency Cycle consistency encourages an input translated from one domain to another and back to resemble the original. It can constrain image translation systems trained without paired examples.
- data augmentation Making new training examples from existing ones by rotating, flipping, deforming, or re-contrasting them. With labeled medical images scarce, nearly every model relies on it to curb overfitting, but each transformation must respect anatomy and imaging physics.
- deep learningDL 2012 Machine learning with many-layered neural networks that learn their own features straight from raw pixels instead of relying on hand-designed ones. Since 2012 it has become the dominant approach to medical image analysis.
- deep supervision Deep supervision adds auxiliary predictions and losses to intermediate layers during training. Earlier layers receive gradients from these auxiliary losses and from the final output loss.
- dense connectivity Dense connectivity passes the outputs of all earlier layers within a block to each later layer by concatenating their channels. It gives later computations direct access to features produced at several depths.
- diffusion model 2015 A generative model that learns to undo noise added step by step; to generate, it starts from pure noise and denoises repeatedly until an image emerges. Dominant in image generation since 2020, it is also used for accelerated MRI reconstruction and synthetic training data.
- domain adaptation Techniques that let a model trained in one domain (a scanner, a modality, a hospital) work in another, usually without new labels from the target. It is one of the main tools against domain shift.
- domain generalizationDG Domain generalization trains a model to work in new domains for which no data were available during training. In imaging, a new domain can be a hospital or acquisition setting.
- domain shift A systematic difference between the data a model was trained on and the data it meets in use: another scanner, protocol, hospital, or patient population. It is the usual reason a model that tests well at its own hospital performs worse elsewhere.
- dropout Dropout is a regularization method that randomly sets some intermediate features to zero during training, so the network must learn to make predictions from varying subsets of its features.
- encoder–decoder A two-part network layout: an encoder compresses the input into a compact representation, and a decoder expands it into the required output, whether a segmentation mask, an image in another modality, or a sentence. U-Net and the autoencoder both follow it.
- explainability Making it possible to see why a model reached a decision, for example by marking the image regions that drove it. Clinicians need this to check results and catch a model using the wrong cues, but a plausible-looking heatmap is not proof of a correct explanation.
- federated learningFL 2017 A way for many hospitals to train one model while patient data stay on site: each site trains locally and sends only model updates to a server that averages them. It sidesteps the legal and practical barriers to pooling medical data.
- foundation model 2021 A large model pretrained on broad data, usually with self-supervised learning, that can be adapted to many downstream tasks. In medical imaging, one such model can be fine-tuned with few labels for many diseases and tasks.
- fully convolutional networkFCN 2015 A classification network with its fully connected layers replaced by convolutions, so that it accepts images of any size and outputs a class for every pixel. Introduced in 2015, it made end-to-end image segmentation with CNNs practical.
- generative adversarial networkGAN 2014 Two networks trained against each other: a generator synthesizes images, a discriminator tries to tell them from real ones, and each improves against the other. Medical imaging uses GANs for synthetic data, modality translation, and low-dose CT denoising, but they can also add or remove lesions.
- Grad-CAM 2017 The most widely used way to visualize which image regions drive a convolutional network's prediction: gradients weight the last layer's feature maps by their importance for one class, and the weighted sum becomes a heatmap over the image.
- graphics processing unitGPU A chip designed for video-game graphics, with thousands of cores working in parallel. Once CUDA (2007) opened it to general computing, it became the main hardware for deep learning and for much fast image reconstruction.
- hallucination When a generative model produces fluent, plausible content with no basis in its input — a report describing a lesion that is not in the image, or a reconstruction showing structure the raw data never contained.
- ImageNet 2009 A large dataset of natural photographs built by Fei-Fei Li's team: about 14 million images in more than 20,000 categories. Its annual challenge saw the AlexNet breakthrough of 2012, and networks pretrained on it long served as the starting point for medical models.
- label noise Label noise occurs when recorded training labels differ from the target a model is intended to predict. It can arise from annotation errors, disagreements, or mistakes in extracting labels from reports.
- large language modelLLM 2020 A very large transformer network trained on huge amounts of text to predict the next word, such as GPT and ChatGPT. It can draft reports and answer medical questions, but it can also produce plausible-sounding statements that are false.
- layer normalizationLN Layer normalization standardizes a single input over specified feature dimensions and then applies learned scales and offsets. The statistics are computed independently for each input.
- machine learningML 1959 Getting a computer to infer its rules from examples instead of having a programmer write them out. In medical imaging nearly everything after the early rule-based computer-aided detection & diagnosis systems, from lesion classifiers to today's segmentation networks, is built this way.
- masked image modelingMIM 2021 A self-supervised pretraining task: hide most of an image's patches and train a network to fill them back in. Doing that well forces it to learn how anatomy is put together, which suits medical imaging, where labels are scarce.
- mean teacher 2017 A semi-supervised method in which a teacher network's weights are a running average of a student network's, and the student learns to agree with the teacher on unlabeled images. Medical segmentation uses it to draw on large numbers of unlabeled scans.
- MedSAM 2024 A promptable segmentation model made by retraining SAM on about 1.57 million medical image–mask pairs (2024). Given a box drawn around an organ or lesion on a CT, MRI, ultrasound, or pathology image, it returns the outline.
- multimodal learning Training one model on several kinds of data at once: two imaging modalities such as CT and PET, images with their reports, or scans with lab results and genomics. Clinicians already reason this way; a single image rarely contains all the relevant information.
- multiple-instance learningMIL 1997 Learning when labels belong to bags of examples rather than to each example. A pathology slide is cut into tens of thousands of tiles, and only the slide as a whole is known to contain cancer or not. It is the standard way to analyze whole-slide images.
- neural network 1943 A learnable function built from layers of simple units, each of which takes a weighted sum of its inputs and passes it through a nonlinearity. Stacking many such layers gives deep learning.
- nnU-Net 2018 A self-configuring segmentation framework from the German Cancer Research Center. Given a new dataset, it reads properties such as image size and voxel spacing and sets up preprocessing, a U-Net, and training on its own, matching or beating most hand-designed methods in public challenges.
- normalizing flow A normalizing flow transforms a simple probability distribution through a series of invertible, differentiable mappings. The change in density induced by each mapping can be calculated.
- overfitting When a model memorizes the accidental details and noise of its training data: near-perfect on the training set, unreliable on new patients. With few cases and many parameters, it is one of the commonest ways medical-imaging models fail.
- point cloud A shape described as a set of 3D coordinates, such as a dental arch from an intraoral scanner, an organ surface extracted from CT, or a vessel centerline. Lighter than a voxel grid, it suits the analysis of shape.
- pooling Merging each small neighborhood of a feature map into one number, its maximum or its average, so the map shrinks and the receptive field grows. The common 2×2 pooling halves both height and width.
- radiology report generation Having a model take a medical image, most often a chest radiograph, and generate the findings and impression of a radiology report. It could lighten a radiologist's writing load, but every sentence still has to be checked.
- random forestRF 2001 Hundreds of slightly different decision trees that vote. Fast to train and tolerant of many features, random forests were a standard tool around 2010 for locating organs, segmenting tissue, and building radiomics models.
- receptive field The patch of the input image that can influence a single unit in a network. Too small, and the model judges texture without context; recognizing a lesion often requires information from the organ around it.
- ResNet 2015 A deep convolutional network from 2015 whose blocks learn only a correction to their input and add it back through a shortcut. The trick made networks of more than 100 layers trainable, and ResNets remain a default backbone of medical-imaging models.
- rollout A model rollout starts from a given state and repeatedly feeds a model's predicted state into the next prediction. The result is one possible sequence of subsequent states.
- Segment Anything ModelSAM 2023 A promptable segmentation model released by Meta AI in 2023: given a clicked point or a drawn box, it returns a mask for that object. Trained on 11 million images, it became the starting point for medical foundation models such as MedSAM.
- self-attention 2017 An operation in which each element of a sequence (a word or an image patch) gathers information from all the others, weighted by relevance. Convolution covers only a local neighborhood; self-attention links distant regions in one step, at a cost that grows with the square of the element count.
- self-supervised learningSSL Training a model on tasks constructed from the data itself, such as filling in a masked part of an image or recognizing two distorted views of the same scan. No human labels are needed, which makes it the main way foundation models are pretrained.
- semi-supervised learning Training on a few labeled images together with many unlabeled ones. A hospital may hold thousands of unannotated scans for every few dozen with expert outlines, and semi-supervised learning is designed for exactly that ratio.
- shared embedding space A shared embedding space is a common vector space into which data from different sources are mapped. Similarity between vectors can then be used to compare inputs such as an image and a sentence.
- skip connection 2015 A connection that lets a signal bypass several layers and arrive further on. Additive skips, as in ResNet, make very deep networks trainable; concatenating skips, as in U-Net, hand fine boundary detail from encoder to decoder, which keeps segmentations sharp.
- supervised learning Training a model on pairs of inputs and correct answers, such as CT scans paired with tumor outlines drawn by radiologists. It usually gives the best accuracy, but every answer costs expert time to annotate.
- support vector machineSVM 1995 A classifier that places the boundary between two classes as far as possible from both, the maximum-margin hyperplane. Paired with hand-crafted features, it was a workhorse of medical image classification in the 2000s.
- Swin Transformer 2021 A hierarchical vision transformer from Microsoft Research Asia (2021) that computes self-attention only inside local windows and shifts the windows between layers. Its cost grows linearly with image size, which suits high-resolution and 3D medical images.
- synthetic data Synthetic data are produced by a simulator or a generative model. They can increase training samples or create controlled combinations of features for tests that are difficult to conduct with acquired data.
- tool use Tool use lets a model request an operation from an external program and use the returned result in further processing. The operation can be retrieval, calculation, or specialized analysis.
- transfer learning Training a model on a large dataset such as ImageNet first, then fine-tuning it on a small medical one. In the early years of deep learning in medical imaging most models started this way, because it sharply cuts the labeled data needed.
- transformer 2017 A neural-network architecture from 2017 that relies entirely on self-attention, letting every element of a sequence exchange information directly with every other. It underlies large language models and entered medical imaging as the vision transformer and its descendants.
- U-Net 2015 A convolutional network designed in 2015 for biomedical image segmentation: one side shrinks the image into features, the other expands them back into a pixel-wise mask, and skip connections carry fine detail across. Most segmentation models still share its shape.
- uncertainty estimation Getting a model to report how uncertain each prediction is, alongside the prediction itself. In medical imaging this lets a system flag the cases, or the stretches of a segmentation boundary, with high uncertainty and pass them to a clinician.
- unified representation A unified representation expresses different inputs or tasks in a compatible form so a common model can process them or so their features can be compared.
- unsupervised learning Learning from data without answers. The algorithm finds structure on its own, grouping similar pixels into tissue classes or learning what normal anatomy looks like so that anything unusual stands out. No labels are needed, but what it finds may not be what clinicians care about.
- V-Net 2016 A 3D fully convolutional network for prostate MRI segmentation, published in 2016. Its lasting contribution is the Dice loss, which optimizes overlap with the ground truth directly so that a small organ in a large volume is not drowned out by background.
- vision transformerViT 2020 An image model that cuts a picture into 16×16-pixel patches and feeds each patch to a transformer as if it were a word. Given enough training data it rivals CNNs, and it is now the most common backbone of medical foundation models.
- vision–language modelVLM 2023 A model that processes images together with text: an image encoder plugged into a large language model. It can answer questions about a chest film, describe findings, and draft a report. Medical examples include LLaVA-Med, Med-PaLM M, and MedGemma.
- weak supervision Training with labels that are coarser, cheaper, or noisier than the task demands: telling a model only that an X-ray shows pneumonia, then asking it where. It spares pixel-level outlining at the cost of noise and localization accuracy.
- weight initialization Weight initialization sets a neural network's weights before training begins. The scale of those initial values helps determine whether signals and gradients can travel through many layers.
- world model A world model learns from observations how a state changes over time. Some world models also take actions as inputs so that they can predict what follows different actions.
Evaluation & clinic33
- automation bias Automation bias is undue reliance on an automated system's suggestions, including the apparent absence of problems when it issues no prompt. It can lead a person to accept an incorrect prompt or miss an issue the system did not flag.
- autonomous AI 2018 A system whose output is the clinical decision itself, with no doctor reviewing the images. The first was IDx-DR, authorized in the US in 2018 to screen for diabetic eye disease; the AI moves from assisting a reader to replacing one.
- bias and fairness When a model performs worse for some groups of patients, by sex, race, age, or insurance, so that they are missed more often. In imaging AI the bias usually comes from the training data, not from anyone's intent.
- CE marking 1993 The mark showing that a product meets EU safety and performance law; a medical device needs it to be sold in the European Economic Area. Many AI imaging products were CE-marked before they reached the US market.
- conformal predictionCP Conformal prediction uses nonconformity scores to construct prediction sets or intervals. Under assumptions such as exchangeability, it gives a finite-sample lower bound on marginal coverage.
- counterfactual prediction Counterfactual prediction estimates an outcome for a given case under an alternative intervention or decision. It can also characterize uncertainty about the outcome under the alternative.
- diagnostic reference levelDRL A diagnostic reference level is a benchmark for a measurable dose indicator in a defined procedure and patient group. It helps identify protocols whose typical values warrant review.
- Dice coefficientDSC 1945 A score for how well two regions overlap, from 0 (no overlap) to 1 (identical). It is the standard evaluation metric for medical image segmentation, and is often used directly as the loss a network is trained to minimize.
- EU AI Act 2024 The EU's 2024 law regulating artificial intelligence by risk. AI medical devices that need third-party review count as high-risk and must meet extra duties on data governance, transparency, and human oversight on top of device law.
- external validation Testing a model on data from another hospital, other scanners, or a later period, rather than on a random slice of its own training pool. It is the minimum check of whether an imaging AI will work outside the place it was built.
- FDA 510(k) clearance 1976 The most common route to the US market for a medical device: show that the new product is substantially equivalent to one already legally sold, its predicate, and the FDA clears it. Most AI imaging software has reached the market by this route.
- FDA De Novo classification 1997 The US route for a novel, low-to-moderate-risk device that has no predicate to compare with. The first AI stroke-triage software and the first autonomous AI diagnostic both came through it, which allowed later products of the same type to use the 510(k) route.
- free-response ROCFROC Free-response ROC evaluates detection tasks that allow multiple location marks on each image. It relates the fraction of lesions found to the average number of false marks per image.
- ground truth The reference treated as the right answer when an algorithm is scored: a biopsy result, a follow-up outcome, or an expert's pixel-by-pixel annotation. It is rarely perfect, and its quality limits how precisely any model can be judged.
- Hausdorff distanceHD 1914 The worst-case distance between two outlines: how far any point on one boundary can lie from the other. Measured in millimeters, it captures stray errors that barely affect an overlap score such as the Dice coefficient.
- inter-observer variability How much experts disagree when they read the same image or outline the same structure. It shows how hard the task really is, and sets a realistic bar for what human-level performance means for an algorithm.
- intersection over unionIoU 1901 The area where a prediction and the reference overlap, divided by the area they cover together. Detection uses it to decide whether a box counts as a hit; in segmentation it converts one-to-one into the Dice coefficient.
- interval cancer An interval cancer is diagnosed after a negative screening examination and before the next scheduled screen, or within the normal screening interval if no further screen is planned. Its frequency helps assess a screening program's performance between appointments.
- marginal coverage Marginal coverage is the probability that a prediction set or interval contains the true outcome, averaged over the population of inputs and outcomes used for evaluation.
- noninferiority trial A noninferiority trial uses the estimated difference and its uncertainty to test whether a new approach is within a prespecified margin of acceptable loss relative to a comparator.
- postmarket monitoring Postmarket monitoring tracks the safety and performance of a medical device in routine use. For imaging AI, it can reveal changes associated with equipment, patient populations, or workflow.
- predetermined change control planPCCP In a US medical device marketing submission, a predetermined change control plan describes planned modifications, how they will be developed, validated, and implemented, and their impact on safety and effectiveness.
- probability calibration Probability calibration describes agreement between predicted probabilities and observed frequencies, and also refers to adjusting predictions to improve that agreement. A model is well calibrated for a population when cases assigned similar risks experience the outcome at roughly that rate.
- prospective validation Prospective validation specifies the model version, eligibility criteria, and evaluation measures in advance, then assesses the model on cases and outcomes collected according to that protocol.
- radiologist A physician trained to interpret medical images and turn them into diagnoses, who also chooses the right examination and performs image-guided procedures. Nearly every imaging AI study measures itself against them.
- reader study An experiment in which several doctors read the same set of cases under controlled conditions, so their accuracy alone, with AI assistance, and against the AI can be compared. It is the usual way imaging AI demonstrates clinical value.
- reference standard adjudication Reference standard adjudication uses prespecified rules to resolve conflicting readings or evidence. It produces the case-level reference labels against which a diagnostic test or model is evaluated.
- ROC curve and AUCAUC The ROC curve plots sensitivity against one minus specificity as a test's threshold is swept from strict to lenient. The area under it, the AUC, sums up discriminating power in one number between 0.5 (chance) and 1.
- sensitivity and specificity 1947 Two basic measures of any diagnostic test: sensitivity is the share of sick people it catches, specificity the share of healthy people it correctly clears. When the decision threshold is moved, one rises as the other falls.
- shortcut learning When a model latches onto a cue that happens to correlate with the answer but has nothing to do with the disease, such as a hospital's corner marker, the scanner, or a chest drain. It scores well in testing and fails elsewhere.
- structural similarity indexSSIM The structural similarity index compares luminance, contrast, and structure in corresponding local regions of two images. It is often used to compare a reconstruction with a reference.
- temperature scaling Temperature scaling adjusts a classifier's probabilities by dividing its raw class scores by one fitted positive number before the softmax. It preserves class rankings for each input while allowing the concentration of probabilities to change.
- triage 2018 Sorting cases by urgency. Imaging triage software screens each new scan and moves suspected strokes, brain bleeds, or collapsed lungs to the top of the reading queue, or alerts the specialist directly.
Standards, data, tools28
- 3D Slicer 1999 A free, open-source platform for viewing and analyzing medical images: load DICOM, segment, register, render in 3D, and export models for printing. It grew out of a surgical planning lab in Boston and is used by researchers worldwide.
- ACR-NEMA standard 1985 The imaging interface standard published in 1985 by the American College of Radiology and NEMA, linking two devices point to point over a dedicated cable. Its tagged data dictionary was carried over into DICOM, its direct successor.
- ADNI 2004 A long-running Alzheimer's study, launched in 2004, that scans the same people again and again with standardized MRI and PET, adds fluid and genetic biomarkers, and shares it all with researchers worldwide without embargo. It is one of the most used datasets in brain-imaging machine learning.
- BraTS 2012 The brain tumor segmentation challenge held every year since 2012. Each case has four MRI sequences, and the task is to outline the enhancing tumor, necrotic core, and surrounding edema of a glioma. It is the standard benchmark for the problem.
- CAMELYON 2016 A pathology challenge from the Netherlands: find breast-cancer metastases in whole-slide images of sentinel lymph nodes. Its 2017 results showed the best deep-learning algorithms outperforming pathologists who worked under a time limit.
- ChestX-ray14 2017 A chest X-ray dataset released by the US National Institutes of Health in 2017: 112,120 frontal films from 30,805 patients, with 14 disease labels mined automatically from reports. It launched large-scale chest X-ray AI and became a textbook case of noisy labels.
- DICOM 1993 The common standard for medical imaging data. It defines a file format, pixel data wrapped in numbered tags that describe patient, scanner, and acquisition, and a network protocol for finding and sending images. It lets scanners from any vendor exchange images with any PACS.
- DICOM transfer syntax A DICOM transfer syntax specifies how a data set is encoded for storage or exchange, including aspects such as byte order, element representation, and pixel compression.
- electronic health recordEHR An electronic health record stores clinical information in digital form, including encounters, diagnoses, medications, test results, and narrative notes. It can bring together information from different stages and providers of care.
- fastMRI 2018 An open MRI dataset released in 2018 by NYU Langone Health and Facebook AI Research, notable for providing raw k-space measurements rather than only finished images. It became the standard benchmark for accelerated MRI and deep-learning reconstruction.
- FreeSurfer 1999 A brain MRI analysis suite from Massachusetts General Hospital that turns a single T1-weighted scan into reconstructed cortical surfaces, cortical-thickness maps, and labeled brain structures. It is one of the most used tools in neuroimaging research.
- grand challenge 2007 A public competition: organizers release labeled training data, keep the test labels hidden, and rank submitted algorithms with metrics fixed in advance. Challenges gave the field a common benchmark and have steered which problems researchers work on.
- grayscale standard display functionGSDF The grayscale standard display function specifies a relationship between grayscale display levels and luminance. Equal steps on the display scale correspond to approximately equal perceptual differences in luminance.
- ISIC archive 2016 The open archive of dermoscopic skin-lesion images kept by the International Skin Imaging Collaboration, with a melanoma-detection challenge every year since 2016. It is the main public data source for skin-lesion AI.
- ITK & VTK 1999 Two foundational open-source toolkits for medical image computing. ITK reads, filters, segments, and registers images; VTK turns them into interactive 3D graphics. 3D Slicer and many other tools are built on top of them.
- JPEG 2000 image codingJP2K JPEG 2000 is a family of still-image coding methods based on wavelet transforms. It supports lossless and lossy compression, and its data can be organized for progressive decoding.
- JPEG image coding JPEG is a family of still-image coding methods. Its common baseline method transforms blocks of pixels and quantizes their coefficients, discarding some detail to reduce the number of bits.
- LIDC-IDRI 2011 A public CT database of lung nodules completed in 2011: 1,018 chest scans from 1,010 patients, each marked independently by four radiologists. It underpins research on nodule detection and malignancy, and documents how much expert readers disagree.
- MIMIC-CXR 2019 A 2019 database of 377,110 chest radiographs from 65,379 emergency patients in Boston, each study paired with its full free-text radiology report. Those image–report pairs made it the main training dataset for report generation and vision–language models.
- MONAI 2020 An open-source, PyTorch-based framework for deep learning in medical imaging, started in 2020 by NVIDIA and King's College London. It supplies tested building blocks for 3D medical data: loading, augmentation, networks, losses, and metrics.
- picture archiving and communication systemPACS 1982 The hospital computer system that stores, moves, and displays medical images: scanners send DICOM files to a central archive, and any authorized workstation can pull them up. It is why film libraries and lightboxes disappeared.
- radiology information systemRIS The radiology department's business system: it schedules exams, registers patients, tracks each study through the workflow, and holds reports and billing. The RIS says who is to be scanned and why; the PACS keeps the images.
- Shepp–Logan phantom 1974 A mathematical "head" published in 1974: ten ellipses standing in for skull, brain, ventricles, and small lesions. Because its true image is known exactly, it became the standard test picture for CT reconstruction algorithms.
- SPM 1991 Statistical Parametric Mapping: both a method and the free software from University College London that made it standard. It fits a general linear model at every voxel and maps where brain signal relates to a task or condition, the basis of most fMRI analysis.
- teleradiology 1950 Sending medical images to a radiologist somewhere else to read. It brings expert interpretation to night shifts, rural hospitals, and small towns, and it was the first branch of telemedicine to become routine.
- The Cancer Imaging ArchiveTCIA 2010 A public archive of cancer images funded by the US National Cancer Institute. It hosts collections of CT, MRI, PET, and pathology images with clinical data, most freely downloadable under Creative Commons licenses, and many classic datasets are hosted there.
- UK Biobank 2006 A cohort of 500,000 UK adults recruited in 2006–2010 and linked to genetics and health records, with an imaging study that aims to scan 100,000 of them: brain, heart, and abdomen by MRI, plus bone and arteries. It is the largest population imaging resource.
- Visible Human Project 1994 A US National Library of Medicine project that scanned two donated bodies with CT and MRI, then froze them, ground them away slice by slice, and photographed each exposed surface. Released in 1994–1995, it was the first complete three-dimensional image of a human body.
People24
- Allan Cormack 1924–1998 South African-born physicist who, in papers of 1963 and 1964, worked out how to rebuild a cross-section of the body from X-ray measurements taken at many angles: the mathematics of CT. He shared the 1979 Nobel Prize with Godfrey Hounsfield.
- David Townsend Physicist who, with engineer Ronald Nutt and colleagues, built the combined PET/CT scanner, in which PET and CT share one gantry and a single examination yields co-registered metabolic and anatomical images. The prototype entered clinical evaluation in Pittsburgh in 1998; commercial systems followed in 2001.
- Edward Purcell 1912–1997 American physicist who detected nuclear magnetic resonance in paraffin wax at Harvard in 1946 and shared the 1952 Nobel Prize with Felix Bloch. His relaxation theory helps explain why tissues differ in T1 and T2, the source of contrast in MRI.
- Fei-Fei Li born 1976 Chinese-American computer scientist who led the building of ImageNet, released in 2009. Networks pretrained on it became the usual starting point for transfer learning in medical imaging, and she later extended her own research into health care.
- Felix Bloch 1905–1983 Swiss-American physicist who detected nuclear magnetic resonance in water at Stanford in 1946 by "nuclear induction" and wrote the Bloch equations for how magnetization precesses and relaxes: the physical basis of every MRI scanner. Nobel Prize in Physics, 1952.
- Geoffrey Hinton born 1947 British-Canadian computer scientist who persisted with neural networks for decades, helped popularize backpropagation in 1986, and with his students built AlexNet in 2012, opening the deep-learning era. Turing Award 2018; Nobel Prize in Physics 2024.
- Godfrey Hounsfield 1919–2004 Electrical engineer at EMI, without a university degree, who conceived the CT scanner in 1967 and built it; the first patient was scanned in 1971. The Hounsfield unit carries his name, and he shared the 1979 Nobel Prize.
- Hal Anger 1920–2005 Berkeley engineer who built the scintillation camera, the gamma camera, around 1957: a sodium iodide crystal coupled to an array of photomultiplier tubes that images a whole organ's tracer uptake at once. Gamma cameras and SPECT still use his design.
- Ian Donald 1910–1987 Glasgow professor of obstetrics who turned an industrial flaw detector into a medical ultrasound imaging scanner and showed in a 1958 Lancet paper that pulsed echoes could be used to examine abdominal masses. Obstetric ultrasound, the routine imaging of the fetus without X-rays, developed from his work.
- Johann Radon 1887–1956 Austrian mathematician who proved in 1917 that a function in the plane can be recovered from its integrals along all straight lines. That result, the Radon transform, became the mathematical core of CT reconstruction half a century later.
- Kaiming He born 1984 Computer vision researcher who, with colleagues at Microsoft Research Asia, introduced ResNet in 2015. Its residual connections made networks over a hundred layers deep trainable, and they now appear in nearly every deep model used in medical imaging.
- Kunio Doi Medical physicist at the University of Chicago and a founder of computer-aided diagnosis. He framed the computer as a "second opinion" for the radiologist, who makes the final call, a framing that still shapes how imaging AI is designed and evaluated.
- Lei Xing Jacob Haimson and Sarah S. Donaldson Professor of Radiation Oncology at Stanford and director of its medical physics division, working on AI in medicine, imaging and radiation therapy; Lequan Yu's postdoctoral advisor.
- Lequan Yu Associate professor at the University of Hong Kong and director of its Medical AI Lab. He works on medical image analysis, multimodal learning and computational pathology, and is first author of UA-MT, a widely used semi-supervised method for 3D segmentation.
- Marie Curie 1867–1934 Polish-French physicist and chemist who discovered polonium and radium and won two Nobel Prizes. In the First World War she organized about 20 X-ray cars and some 200 fixed posts that brought radiography to wounded soldiers near the front.
- Olaf Ronneberger Computer scientist at the University of Freiburg who, with Philipp Fischer and Thomas Brox, introduced U-Net in 2015, the most widely used architecture for medical image segmentation. He later joined DeepMind and co-authored AlphaFold.
- Paul Lauterbur 1929–2007 American chemist who showed in 1973 that adding a magnetic field gradient makes nuclei at different positions resonate at different frequencies, so an NMR signal can be turned into a picture. It is the founding idea of MRI; Nobel Prize 2003.
- Peter Mansfield 1933–2017 British physicist who left school at 15 to work for a printer, then, at the University of Nottingham, developed slice selection and in 1977 invented echo-planar imaging, which captures a whole MR image in a fraction of a second. Nobel Prize 2003.
- Pheng-Ann Heng Choh-Ming Li Professor of Computer Science and Engineering at the Chinese University of Hong Kong, working on AI and virtual reality for medicine and on surgical simulation; one of Lequan Yu's doctoral supervisors.
- Raymond Damadian 1936–2022 American physician who reported in 1971 that tumors have longer NMR relaxation times than normal tissue and proposed NMR for cancer detection. In 1977 his home-built scanner, Indomitable, imaged a human chest. His exclusion from the 2003 Nobel Prize remains contested.
- Seiji Ogawa born 1934 Japanese biophysicist who found at Bell Labs in 1990 that deoxygenated hemoglobin acts as a natural MRI contrast agent. His BOLD contrast underlies nearly all functional MRI, letting researchers watch brain activity without injections or radiation.
- Wilhelm Röntgen 1845–1923 German physicist who discovered X-rays in Würzburg in November 1895 and, weeks later, imaged the bones of his wife's hand, the first image of the interior of a living body obtained without surgery. He received the first Nobel Prize in Physics in 1901.
- Willi Kalender 1949–2024 German medical physicist who developed spiral CT at Siemens: the table moves steadily while the tube rotates continuously, so a whole organ is scanned in a single breath-hold. First clinical results came in 1989; volume scanning has been the norm since.
- William Lorensen 1946–2019 Computer graphics researcher at General Electric who, with Harvey Cline, published the marching cubes algorithm in 1987, turning CT and MRI volumes into 3D surface meshes. He later co-wrote VTK, the open-source visualization toolkit under much of today's medical imaging software.
Organisations8
- EMI 1931 Electric and Musical Industries, the British record and electronics company in whose Central Research Laboratories Godfrey Hounsfield built the first clinical CT scanner. It scanned its first patient in 1971; within a decade EMI had left the business.
- HKU MedAI LabHKU-MedAI The Medical Artificial Intelligence Laboratory at the University of Hong Kong, led by Lequan Yu. It works on multimodal medical data, computational pathology, medical vision–language models and agents for healthcare.
- IEEE International Symposium on Biomedical ImagingISBI 2002 The IEEE's yearly biomedical-imaging meeting, founded in 2002 and covering every scale from microscopy to whole-body scans. Its challenges include early successes of deep learning: a deep network won its 2012 electron-microscopy segmentation contest, and U-Net won its 2015 cell-tracking challenge.
- IEEE Transactions on Medical ImagingIEEE TMI 1982 The IEEE's flagship medical-imaging journal, founded in 1982. It spans imaging physics, reconstruction, and image analysis, and is where many reconstruction algorithms, segmentation methods, and public benchmarks received their definitive papers.
- MICCAI 1998 Medical Image Computing and Computer Assisted Intervention: the yearly conference, held since 1998, that is the main academic venue for medical-image analysis. U-Net and many public challenges were first presented there.
- Nobel Prize 1901 The prizes founded by Alfred Nobel's will and first awarded in 1901. Several have recognized work on imaging: the very first physics prize went to X-rays, followed by NMR (1952), CT (1979), MRI (2003), and in 2024 the physics prize for neural networks.
- Radiological Society of North AmericaRSNA 1915 One of the world's largest radiology societies. Its Chicago meeting, held each year around the start of December, draws close to 40,000 people, and it publishes the journal Radiology. In 1972 the EMI CT scanner was shown to its members and drew a standing ovation.
- US Food and Drug AdministrationFDA 1906 The US federal agency that must authorize a medical device, including AI software, before it can be sold in the United States. Its public list of AI-enabled devices passed 1,600 entries in 2026, about three quarters of them in radiology.