LIDC-IDRI

A public CT database of lung nodules completed in 2011: 1,018 chest scans from 1,010 patients, each marked independently by four radiologists. It underpins research on nodule detection and malignancy, and documents how much expert readers disagree.

LIDC was started by the US National Cancer Institute and later expanded with IDRI, bringing together seven academic centers and eight imaging companies. Every CT scan went through a two-phase read: four thoracic radiologists first marked lesions independently, then saw the others' marks and revised their own, with no forced consensus. Nodules of 3 mm or more were outlined and rated on nine characteristics, including calcification, spiculation, and likelihood of malignancy.

Skipping forced consensus is what makes the data valuable. Of 2,669 lesions marked as nodules of at least 3 mm by one or more readers, only 928 were marked by all four. That gives a real measure of inter-observer variability and lets researchers train models that output several plausible segmentations.

The data are free from TCIA. The 2016 LUNA16 challenge took 888 of its scans as a nodule-detection benchmark, and a generation of CAD and deep-learning methods has been compared on it.

Sources
  1. Armato SG III, McLennan G, Bidaut L, et al. The Lung Image Database Consortium (LIDC) and Image Database Resource Initiative (IDRI): a completed reference database of lung nodules on CT scans. Med Phys. 2011;38(2):915–931. doi.org/10.1118/1.3528204
  2. Setio AAA, Traverso A, de Bel T, et al. Validation, comparison, and combination of algorithms for automatic detection of pulmonary nodules in computed tomography images: the LUNA16 challenge. Med Image Anal. 2017;42:1–13. arxiv.org/abs/1612.08012

Key works · 2

Landmark2011Medical Physics3,570 citations

The Lung Image Database Consortium (LIDC) and Image Database Resource Initiative (IDRI): A Completed Reference Database of Lung Nodules on CT Scans

Samuel G. Armato, Geoffrey McLennan … Anthony P. Reeves

The collection comprised 1,018 thoracic CT cases. Four radiologists independently marked lesions and then reviewed other readers' anonymized marks before finalizing their own. Of 2,669 findings marked as nodules at least 3 mm by any reader, 928 received that mark from all four.

SignificancePreserving reader-level marks allowed studies to account for disagreement when building nodule references. LUNA16 later used a subset of these scans and annotations to create a standardized detection benchmark with shared definitions for candidates and false positives.

Key2017Medical Image Analysis1,681 citations

Validation, comparison, and combination of algorithms for automatic detection of pulmonary nodules in computed tomography images: The LUNA16 challenge

Arnaud Arindra Adiyoso Setio, Alberto Traverso … Piergiorgio Cerello

LUNA16 evaluated complete nodule detection and false-positive reduction on a common subset of 888 LIDC-IDRI CT scans. It compared submissions using shared folds and false-positive criteria. Combining several systems yielded sensitivity above 95% at fewer than one false positive per scan.

SignificanceThe two tracks separated the effects of generating candidates and classifying them. By publishing the scan splits, nodule references, and scoring procedure, LUNA16 provided a reproducible comparison for complete systems and specific stages of CT nodule detection.