low-dose CTLDCT
低剂量CT
CT run at deliberately reduced tube current or voltage, cutting dose to a fraction of a standard scan at the cost of more image noise. In 2011 a US trial of 53,454 heavy smokers showed that screening with it lowered lung-cancer deaths by 20%.
Quantum noise in CT scales roughly as one over the square root of dose, : reducing the dose to a quarter doubles the noise. Lung offers enormous contrast between air and tissue, so nodules a few millimeters across stay visible through the extra noise, and screening protocols aim for an effective dose of about 1.5 mSv rather than the 6–8 mSv of a diagnostic chest CT.
The US National Lung Screening Trial randomized 53,454 heavy smokers aged 55–74 to low-dose CT or chest radiography. Reported in the New England Journal of Medicine in 2011, it found 20.0% fewer lung-cancer deaths with CT. It also found that 24.2% of CT screens were positive, and that 96.4% of those positives were false alarms.
Those false positives drove structured nodule-management schemes such as Lung-RADS and made automated nodule detection an important target for imaging AI, while iterative reconstruction and deep-learning reconstruction push the dose lower still.
- National Lung Screening Trial Research Team (Aberle DR, et al.). Reduced lung-cancer mortality with low-dose computed tomographic screening. N Engl J Med. 2011;365(5):395–409. doi.org/10.1056/NEJMoa1102873
- RadiologyInfo.org (RSNA/ACR). Radiation dose in X-ray and CT exams. www.radiologyinfo.org/en/info/safety-xray
Key works · 10
Landmark2011New England Journal of Medicine12,304 citations
Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening
At 33 centers, the National Lung Screening Trial randomly assigned high-risk participants to three annual rounds of low-dose CT or single-view chest radiography. Lung cancer mortality was 20% lower in the CT group. That group also had more positive screening results, most of which were false positives.
SignificanceThe trial showed that the evaluation of low-dose CT screening could measure lung cancer deaths along with detection and false-positive results. The US Preventive Services Task Force included NLST in its evidence for lung cancer screening recommendations.
DOI Full text Denise R. AberleChristine D. Berg low-dose CTradiographysensitivity and specificity
Landmark2017IEEE Transactions on Medical Imaging2,163 citations
Low-Dose CT With a Residual Encoder-Decoder Convolutional Neural Network
RED-CNN trained a residual convolutional encoder-decoder on image patches to denoise reconstructed low-dose CT. Its shortcuts linked encoder and decoder layers. Tests using simulated and clinical images compared noise suppression, preservation of anatomical structure, and lesion visibility with those of other image-domain methods.
SignificanceRED-CNN became a reference for denoising low-dose CT images after reconstruction, which makes the method testable without access to vendor-specific projections. Zeng and colleagues used it to study how differences in dose, reconstruction kernel, and slice thickness between training and testing affect denoising.
DOI arXiv Full text Hu ChenYi ZhangGe Wang low-dose CTdenoisingencoder–decoderskip connection
Landmark2019Nature Medicine2,876 citations
End-to-end lung cancer screening with three-dimensional deep learning on low-dose chest computed tomography
A volumetric model estimates lung cancer risk from low-dose chest CT, incorporating a prior scan when available. It achieved an AUC of 0.944 on held-out National Lung Screening Trial cases. The study also evaluated 1,139 independent clinical cases and compared readers with and without prior imaging.
SignificanceThe study provided an early end-to-end benchmark for lung screening from volumetric CT and made the availability of prior imaging explicit in the reader comparison. Sybil cites this work and extends the question to multiyear risk estimation from a single scan.
DOI Diego ArdilaDaniel TseShravya Shetty low-dose CTROC curve and AUCreader studyexternal validation
Key2012The Lancet4,240 citations
Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study
The authors followed a retrospective cohort of children and young adults examined by CT in Great Britain. They estimated cumulative absorbed doses to red bone marrow and the brain and used cancer registry data to assess subsequent disease. Estimated doses were positively associated with leukemia and brain tumor incidence.
SignificanceThe study supplied direct epidemiologic evidence linking reconstructed organ doses from childhood CT with later cancer incidence. The National Cancer Institute cites the results in its discussion of pediatric CT radiation, including the need to optimize exposure.
DOI Full text Mark S. PearceAmy Berrington de González radiation doseionizing radiationlow-dose CT
Key2017Medical Physics924 citations
A deep convolutional neural network using directional wavelets for low‐dose X‐ray CT reconstruction
The researchers applied a residual convolutional network to directional wavelet coefficients of reconstructed low-dose CT. The transform exposed oriented noise patterns and dependencies across bands. The method placed second in the 2016 Low Dose CT Grand Challenge, whose evaluation included readers marking liver metastases.
SignificanceThe challenge gave this early denoising method a common test set and a reader-based endpoint. The approach also established a practical example of performing learned denoising in a transform basis, a distinction retained in later reviews of low-dose CT methods.
DOI arXiv Eunhee KangJong Chul Ye low-dose CTdenoisingartifact
Key2017IEEE Transactions on Medical Imaging1,150 citations
Generative Adversarial Networks for Noise Reduction in Low-Dose CT
The authors trained a denoiser using cardiac CT images acquired at 20% of the routine dose. Voxel loss alone yielded the highest peak signal-to-noise ratio, while adversarial training better reproduced routine-dose image statistics. Denoising improved low-density calcium measurements in phantoms and enabled calcium scoring on noisy patient scans.
SignificanceThe experiment distinguished agreement with reference pixels, similarity of noise appearance, and usability for calcium scoring on the same set of scans. Reviews of low-dose CT restoration include it among the early uses of adversarial objectives in image-domain denoising.
DOI Jelmer M. WolterinkIvana Išgum generative adversarial networklow-dose CTdenoising
Key2017Medical Physics425 citations
Low-dose CT for the detection and classification of metastatic liver lesions: Results of the 2016 Low Dose CT Grand Challenge
The Low Dose CT Grand Challenge supplied common contrast-enhanced CT cases to groups testing image-space denoising or iterative reconstruction. Participants reconstructed twenty quarter-dose test examinations. Eleven blinded readers marked liver metastases, with substantial differences in reader scores across the submitted reconstruction and denoising methods.
SignificanceThe competition tied reconstruction evaluation to the clinical task of detecting liver metastases. The Cancer Imaging Archive's larger collection includes 13 of the challenge test cases. A separate release provides all 30 training and test cases in the same standardized projection format for further comparisons.
DOI Full text Cynthia H. McColloughJoel G. Fletcher low-dose CTreader studygrand challengefree-response ROC
Key2020New England Journal of Medicine4,125 citations
Reduced Lung-Cancer Mortality with Volume CT Screening in a Randomized Trial
NELSON randomly assigned 13,195 men in the primary analysis to low-dose CT screening or no screening. Another 2,594 women were included in subgroup analyses. The trial used nodule volumes and growth to guide follow-up. At 10 years the male lung-cancer mortality rate ratio was 0.76, with a 95% confidence interval of 0.61 to 0.94.
SignificanceNELSON supplied randomized mortality evidence for a screening program that used volumetric nodule management and a no-screening control. The US Preventive Services Task Force evidence review identified NELSON and the US National Lung Screening Trial as the two adequately powered trials for lung-cancer mortality.
DOI Harry J. de KoningMatthijs Oudkerk low-dose CTcomputed tomography
Key2023Radiology528 citations
Deep Learning Image Reconstruction for CT: Technical Principles and Clinical Prospects
The review traced clinical CT reconstruction from filtered back-projection through iterative and learned methods. It described commercial training targets and summarized evidence for noise texture, spatial resolution, and dose reduction across applications. It also examined metal artifact reduction and prospective uses in photon-counting CT.
SignificanceThe review assembled early clinical evidence for scanner-integrated deep learning reconstruction and explained why different training targets can yield different image properties. It provides a reference for tracing commercial implementations to their underlying studies and for comparing results across protocols and clinical tasks.
DOI Full text Lennart R. KoetzierMartin J. Willemink deep-learning reconstructionlow-dose CTiterative reconstructionmetal artifact reduction
Key2023Journal of Clinical Oncology391 citations
Sybil: A Validated Deep Learning Model to Predict Future Lung Cancer Risk From a Single Low-Dose Chest Computed Tomography
Sybil estimates future lung cancer risk from one low-dose chest CT over a period of up to six years without clinical inputs or nodule annotations at inference. The authors report separate validation results in held-out NLST data and hospital cohorts in the United States and Taiwan.
SignificanceThe model extended CT screening research from identifying existing lesions to estimating risk over several years. The released model enabled external evaluations, including a later screening cohort with predominantly Black participants in which investigators separately reported discrimination.
DOI Full text Peter G. MikhaelLecia V. SequistRegina Barzilay low-dose CTexternal validationROC curve and AUC