Image basics

artifact

伪影

A feature in the image that is not present in the patient, produced by the physics, the equipment or motion. Artifacts can mimic disease or hide it, so recognising them is a basic reading skill.

Every modality has its own artifacts, and they often expose how the image was made. In CT, metal blocks nearly all X-rays, and filtered back-projection smears the corrupted readings back along their rays as bright and dark streaks. The beam also loses its low-energy photons first as it crosses the body; this beam hardening leaves dark bands between dense bones. In MRI, motion during the scan leaves ghosts along the phase-encoding direction, and a field of view smaller than the body causes wrap-around aliasing.

Some artifacts help. A gallstone reflects almost all the ultrasound that reaches it and casts a black acoustic shadow behind it, one of the main clues to its presence.

Artifacts mislead algorithms as well as people. A model can learn to rely on artifacts peculiar to one hospital's scanners, a classic route to shortcut learning and failure under domain shift.

Key works · 7

Key2002IEEE Transactions on Medical Imaging757 citations

Statistical image reconstruction for polyenergetic X-ray computed tomography

I. A. Elbakri, J. A. Fessler

The authors incorporated the source spectrum and energy-dependent attenuation into a statistical CT model. They estimated voxel densities using penalized likelihood and an ordered-subsets algorithm. In simulated measurements of objects containing bone and soft tissue, the reconstruction reduced beam-hardening artifacts.

SignificanceThe work demonstrated how statistical reconstruction can account for beam-hardening physics within the forward model. It is a reference for later model-based CT approaches that incorporate the physics of the transmission measurements into the image estimate itself.

Key2008Chest2,690 citations

Relevance of Lung Ultrasound in the Diagnosis of Acute Respiratory Failure: The BLUE Protocol

Daniel A. Lichtenstein, Gilbert A. Mezière

The investigators performed bedside ultrasound in patients admitted with acute respiratory failure and combined findings such as lung sliding, lung artifacts, and venous ultrasound into diagnostic profiles. They compared the resulting profiles with final diagnoses to assess discrimination among common causes of respiratory failure.

SignificanceThe report provided a structured, reproducible bedside ultrasound examination for investigating acute respiratory failure. Its combination of lung artifacts, pleural motion, and venous findings gave subsequent emergency and intensive care ultrasound studies a protocol they could evaluate.

Key2017Medical Physics924 citations

A deep convolutional neural network using directional wavelets for low‐dose X‐ray CT reconstruction

Eunhee Kang, Junhong Min, Jong Chul Ye

The researchers applied a residual convolutional network to directional wavelet coefficients of reconstructed low-dose CT. The transform exposed oriented noise patterns and dependencies across bands. The method placed second in the 2016 Low Dose CT Grand Challenge, whose evaluation included readers marking liver metastases.

SignificanceThe challenge gave this early denoising method a common test set and a reader-based endpoint. The approach also established a practical example of performing learned denoising in a transform basis, a distinction retained in later reviews of low-dose CT methods.

Key2019CVPR 2019353 citations

DuDoNet: Dual Domain Network for CT Metal Artifact Reduction

Wei-An Lin, Haofu Liao … Shaohua Kevin Zhou

DuDoNet corrected metal-corrupted sinograms and refined the resulting CT images within one trainable network. A differentiable Radon inversion layer connected the two stages. In the reported experiments, joint processing improved detail recovery and reduced residual and secondary artifacts relative to single-domain approaches.

SignificanceDuDoNet provided a concrete dual-domain baseline for learned metal artifact reduction. Later work on deep sinogram completion with an image prior compared against it when studying how projection continuity at the metal trace boundary affects artifacts after reconstruction.

Key2020Proceedings of the National Academy of Sciences1,000 citations

On instabilities of deep learning in image reconstruction and the potential costs of AI

Vegard Antun, Francesco Renna … Anders C. Hansen

The authors tested learned reconstruction algorithms by applying small perturbations, introducing localized structures, and varying the number of samples. They documented examples of visible artifacts, missed small structures, and worse reconstructions when additional measurements were provided. The paper released software for reproducing the stability tests.

SignificanceThe study turned stability into a concrete evaluation problem and published tests for failures that average reconstruction scores can miss. The subsequent fastMRI brain challenge documented related failure modes in highly ranked submissions, including false structures in images with high structural similarity.

Notable2003Investigative Radiology247 citations

Magnetic Resonance Imaging at 3.0 Tesla: Challenges and Advantages in Clinical Neurological Imaging

Richard Frayne, Bradley G. Goodyear … Robert J. Sevick

The Calgary group summarized 40 months of clinical neuroradiology at 3 tesla and presented patient images to illustrate potential benefits relative to 1.5 tesla. They described higher signal-to-noise and changes in contrast alongside practical issues involving radio-frequency power, coil design, and implant compatibility.

SignificanceThis report documented early clinical operation at 3 tesla and made the practical demands of higher-field imaging explicit alongside its benefits. Later guidance from the American College of Radiology continues to address risks by field strength and device conditions.

Notable2021IEEE Transactions on Medical Imaging184 citations

Deep Sinogram Completion With Image Prior for Metal Artifact Reduction in CT Images

Lequan Yu, Zhicheng Zhang … Lei Xing

The method produced an image prior and projected it forward differentiably to guide a second network that repaired metal-corrupted sinogram values. Filtered back-projection yielded the final image. Experiments with simulated and real artifacts examined projection continuity around metal traces and reported reduced artifacts relative to the comparison methods.

SignificanceThe paper showed how an estimated image could guide a projection-space correction and how that correction could be tested on both simulated and real artifacts. The differentiable forward operator allowed the prior-image and sinogram networks to be optimized jointly.