hallucination
幻觉
When a generative model produces fluent, plausible content with no basis in its input — a report describing a lesion that is not in the image, or a reconstruction showing structure the raw data never contained.
Large language models and vision–language models generate text token by token toward what is likely, not what the image proves. They can describe a nodule that is not there, compare against a prior study that does not exist, or cite a paper that was never written. In report generation this is harder to catch than a missed finding, because the text reads fluently and is correctly formatted.
Image reconstruction has the same failure. Reviewers of the 2020 fastMRI challenge found that deep-learning reconstructions at high acceleration could add small structures absent from the raw data, or erase real small lesions, while the image still looked sharp.
Remedies include grounding each statement in an image region or the raw data, measuring hallucination rates explicitly in evaluation, and keeping a clinician's review on the final conclusion.
Key works · 9
Landmark2023Nature7,472 citations
Large language models encode clinical knowledge
The authors assembled MultiMedQA and used instruction prompt tuning to adapt Flan-PaLM to medicine. Alongside multiple-choice accuracy, human reviewers scored free-text responses for factuality, reasoning, potential harm, and bias. The medically adapted model narrowed some of the gaps with clinician responses.
SignificanceMultiMedQA brought professional examinations, research questions, and consumer questions into one evaluation suite. The Med-PaLM 2 study used those comparisons and extended the human evaluation, making it possible to measure changes in both exam performance and the quality of open-ended answers.
DOI arXiv Full text Karan SinghalShekoofeh AziziAlan KarthikesalingamVivek Natarajan large language modelfoundation modelbias and fairnesshallucination
Key2018MICCAI 2018 (LNCS 11070)487 citations
Distribution Matching Losses Can Hallucinate Features in Medical Image Translation
The authors varied the frequency of abnormalities between source and target image distributions and tested how CycleGAN translation responded. The experiments demonstrated that matching the target distribution could remove an abnormal feature present in the input or introduce a feature resembling pathology.
SignificanceThe study gave controlled evidence that a plausible translated image can change pathology when the target cohort has different disease prevalence. It provided a reproducible way to evaluate patient-level fidelity separately from visual realism or resemblance to a target image collection.
DOI arXiv Joseph Paul CohenSina Honari generative adversarial networkhallucinationdomain shiftcycle consistency
Key2020Proceedings of the National Academy of Sciences1,000 citations
On instabilities of deep learning in image reconstruction and the potential costs of AI
The authors tested learned reconstruction algorithms by applying small perturbations, introducing localized structures, and varying the number of samples. They documented examples of visible artifacts, missed small structures, and worse reconstructions when additional measurements were provided. The paper released software for reproducing the stability tests.
SignificanceThe study turned stability into a concrete evaluation problem and published tests for failures that average reconstruction scores can miss. The subsequent fastMRI brain challenge documented related failure modes in highly ranked submissions, including false structures in images with high structural similarity.
DOI arXiv Vegard AntunAnders C. Hansen inverse problemartifacthallucination
Key2021IEEE Transactions on Medical Imaging485 citations
Results of the 2020 fastMRI Challenge for Machine Learning MR Image Reconstruction
The second fastMRI challenge used raw clinical brain MRI and included a transfer track for scanners outside the training set. Radiologists reviewed pathological findings, complementing quantitative image similarity scores. Some high-scoring reconstructions contained a false vessel or a bright line resembling a cerebrospinal fluid cleft.
SignificanceThe challenge incorporated scanner transfer and preservation of pathology into a public benchmark. Its documented failures give concrete examples for understanding when similarity scores and clinical judgments diverge, and for designing evaluations that examine individual structures in reconstructed images.
DOI arXiv Full text Matthew J. MuckleyFlorian Knoll fastMRIhallucinationgrand challengereader studystructural similarity index
Key2023Patterns396 citations
Evaluating progress in automatic chest X-ray radiology report generation
The study compared automatic report scores with radiologists’ counts of errors. RadGraph F1 scored overlap in clinical entities and relations, while RadCliQ combined measures to estimate error counts. Both aligned more closely with radiologist judgments than several conventional measures of textual similarity.
SignificanceThe study made radiologists’ error judgments an external criterion for choosing report metrics. Subsequent report generation experiments used both RadGraph F1 and RadCliQ to test whether improvements in text generation were accompanied by improvements in the clinical content measured by those scores.
DOI Full text Feiyang YuPranav Rajpurkar radiology report generationhallucinationMIMIC-CXR
Key2023npj Digital Medicine649 citations
Large language models propagate race-based medicine
The authors repeatedly queried four commercially available language models with questions developed to expose outdated race-based assumptions in medicine. Outputs from every tested model contained examples of potentially harmful race-based claims, and some answers changed when the same question was asked again.
SignificanceThe study gave safety evaluations a concrete way to test the recurrence of harmful medical assumptions through repeated prompts. Its observations show why average question-answering accuracy leaves out both content that can harm particular groups and variability across identical requests.
DOI Full text Jesutofunmi A. OmiyeRoxana Daneshjou large language modelbias and fairnesshallucination
Key2025Nature Medicine330 citations
Collaboration between clinicians and vision–language models in radiology report generation
The authors trained Flamingo-CXR to generate chest radiograph reports and convened a radiologist panel to review model and clinician reports retrospectively. For inpatient and outpatient radiographs, clinically significant errors occurred in both reports in 24.8% of cases, only the generated report in 22.8%, and only the clinician report in 14.0%.
SignificanceThe error review also supplied edits for a retrospective proof of concept. Radiologists’ corrections were incorporated into model drafts, and raters compared the edited reports with the original clinical reports. Janus-Pro-CXR subsequently examined report quality and time in a prospective workflow study.
DOI Full text Ryutaro TannoDavid G. T. BarrettAlan KarthikesalingamSofia Ira Ktena vision–language modelradiology report generationreader studyhallucination
Key2025Nature Medicine3,155 citations
Toward expert-level medical question answering with large language models
Med-PaLM 2 combined a stronger base model, medical adaptation, and strategies for aggregating candidate responses and retrieving evidence. It achieved up to 86.5% on the MedQA examination benchmark. Physicians also assessed longer answers to standard, adversarial, and real-world medical questions.
SignificanceThe study extended earlier question-answering comparisons with adversarial prompts and a specialist review of real consultation questions. Its separate measures for exam questions, longer responses, and different physician groups made it possible to identify where gains generalized and where they depended on the comparison.
DOI arXiv Full text Karan SinghalTao TuShekoofeh AziziAlan KarthikesalingamVivek Natarajan large language modelfoundation modelhallucination
Notable2024arXiv (Cornell University)249 citations
Advancing Multimodal Medical Capabilities of Gemini
The Med-Gemini preprint described models adapted from Gemini to inputs including two-dimensional images, volumetric scans, and genomics. It reported expert evaluation of chest radiograph and head CT reports. Presented examples included both clinically acceptable outputs and generated findings unsupported by the study or comparison report.
SignificanceThe preprint extended expert evaluation of generative vision-language models to volumetric head CT reporting. Its published examples make it possible to inspect errors in anatomical wording and clinical findings that would otherwise be hidden by aggregate acceptability scores.
DOI arXiv Lin YangDaniel I. Golden vision–language modelmultimodal learningradiology report generationhallucination