MIMIC-CXR
A 2019 database of 377,110 chest radiographs from 65,379 emergency patients in Boston, each study paired with its full free-text radiology report. Those image–report pairs made it the main training dataset for report generation and vision–language models.
MIMIC-CXR was released by Alistair Johnson and colleagues at the MIT Laboratory for Computational Physiology together with Beth Israel Deaconess Medical Center. It holds 227,835 studies and 377,110 chest radiographs in DICOM format from the hospital's emergency department between 2011 and 2016, most studies with a frontal and a lateral view, each with its original report. Everything was de-identified to the US HIPAA Safe Harbor standard, including names and dates inside the report text.
The data sit on PhysioNet under credentialed access: researchers complete human-subjects training and sign a data use agreement before downloading. A companion release, MIMIC-CXR-JPG, converts the images to JPG and adds 14 labels extracted from the reports by automatic labelers.
Unlike ChestX-ray14, which offers only labels, MIMIC-CXR keeps the sentences radiologists actually wrote. That turned writing a report from an image into a task that can be measured, and lets researchers check whether a model's report describes findings that are not in the image at all.
- Johnson AEW, Pollard TJ, Berkowitz SJ, et al. MIMIC-CXR, a de-identified publicly available database of chest radiographs with free-text reports. Sci Data. 2019;6:317. doi.org/10.1038/s41597-019-0322-0
- Johnson AEW, Pollard TJ, Mark RG, Berkowitz SJ, Horng S. MIMIC-CXR Database (version 2.0.0). PhysioNet. 2019. doi.org/10.13026/C2JT1Q
Key works · 9
Landmark2019Scientific Data3,108 citations
MIMIC-CXR, a de-identified publicly available database of chest radiographs with free-text reports
The paper documented the de-identification and organization of MIMIC-CXR. It linked 377,110 chest radiographs from 227,835 studies to contemporaneous free-text reports. A study could include multiple radiographic views, allowing analysis to use the images together with the corresponding clinical interpretation.
SignificancePaired images and reports made a common clinical source available for work on report-derived labeling, report generation, and image–text modeling. Credentialed access through PhysioNet enables reuse under a common data-use agreement and preserves the documented study-to-image relationships.
DOI Full text Alistair E. W. JohnsonSteven Horng MIMIC-CXRradiographyDICOMradiology report generationmultimodal learning
Key2020EMNLP 2020735 citations
CheXbert: Combining Automatic Labelers and Expert Annotations for Accurate Radiology Report Labeling Using BERT
CheXbert first trained a biomedical BERT model on labels supplied by a rules-based chest radiograph report labeler, then fine-tuned it with a smaller set of expert annotations augmented by back-translation. On the report labeling evaluation, it improved on the selected rules-based comparison.
SignificanceCheXbert supplied a reusable extractor of chest radiograph findings from text. It also became part of report generation evaluation, where the RadCliQ study tested whether CheXbert-derived representations and other metrics captured differences judged clinically important by radiologists.
DOI arXiv Full text Akshay SmitMatthew P. Lungren transformerweak supervisionradiology report generationMIMIC-CXRclinical natural language processing
Key2020EMNLP 20201,113 citations
Generating Radiology Reports via Memory-driven Transformer
R2Gen used a relational memory to track information as a transformer decoder generated a radiology report, conditioning the decoder on that memory. On IU X-Ray and MIMIC-CXR, it improved language-generation scores and the paper’s clinical evaluations compared with the selected earlier methods.
SignificanceR2Gen provided a reusable transformer-based report generator and published comparative results on MIMIC-CXR. The later RadCliQ study used it alongside other systems to test how closely automatic report evaluation scores tracked clinically significant errors that radiologists identified.
DOI arXiv Full text Zhihong ChenXiang Wan transformerradiology report generationMIMIC-CXR
Key2021NeurIPS 2021 (Datasets and Benchmarks)468 citations
RadGraph: Extracting Clinical Entities and Relations from Radiology Reports
RadGraph defined a schema for annotating anatomy, observations, and relations in chest radiograph reports. Radiologists labeled development reports from MIMIC-CXR and a test set drawn from MIMIC-CXR and CheXpert. The authors released annotated data and trained a model to extract the same structures automatically.
SignificanceThe relation annotations made it possible to compare reports by clinical structure as well as wording. RadGraph F1 later used that structure for evaluating generated reports, and RadGraph-XL extended the resource to additional modalities and anatomical regions.
arXiv Saahil JainPranav Rajpurkar radiology report generationMIMIC-CXRannotationclinical natural language processing
Key2022Nature Biomedical Engineering736 citations
Expert-level detection of pathologies from unannotated chest X-ray images via self-supervised learning
CheXzero learned jointly from chest radiographs and their reports and used positive and negative text prompts to classify findings without task-specific labels at training time. In an external dataset, it outperformed one fully supervised comparator on three of eight findings.
SignificanceThe study operationalized CLIP-style classification for multilabel imaging findings using positive and negative prompts and external evaluation. Subsequent experiments on zero-shot chest radiograph recognition have used CheXzero as a comparison when testing more detailed disease descriptions and image-text alignment.
DOI Full text Ekin TiuPranav Rajpurkar contrastive learningCLIPMIMIC-CXRexternal validationshared embedding space
Key2023Patterns396 citations
Evaluating progress in automatic chest X-ray radiology report generation
The study compared automatic report scores with radiologists’ counts of errors. RadGraph F1 scored overlap in clinical entities and relations, while RadCliQ combined measures to estimate error counts. Both aligned more closely with radiologist judgments than several conventional measures of textual similarity.
SignificanceThe study made radiologists’ error judgments an external criterion for choosing report metrics. Subsequent report generation experiments used both RadGraph F1 and RadCliQ to test whether improvements in text generation were accompanied by improvements in the clinical content measured by those scores.
DOI Full text Feiyang YuPranav Rajpurkar radiology report generationhallucinationMIMIC-CXR
Notable2020MIDL 2020 (PMLR 121)80 citations
Continual Learning for Domain Adaptation in Chest X-ray Classification
The authors tested continual adaptation between ChestX-ray14 and MIMIC-CXR using joint training, elastic weight consolidation, and Learning without Forgetting. Joint training achieved the best overall performance. Learning without Forgetting offered competitive results while retaining prior-domain performance without needing to revisit the original source images.
SignificanceThis study evaluated model updates on both the original and new domains, making forgetting measurable in a medical imaging setting. Perkonigg and colleagues subsequently cited that line of work when studying scanner changes in a continuous stream with a limited labeling budget.
arXiv domain adaptationdomain shiftChestX-ray14MIMIC-CXRcontinual learning
Notable2024ECCV 2024 (LNCS 15115)69 citations
HERGen: Elevating Radiology Report Generation with Longitudinal Data
HERGen used a group-causal transformer to incorporate imaging from a patient’s earlier exams and a contrastive objective to align image sequences with their reports. The authors derived a longitudinal subset of MIMIC-CXR and evaluated what happened when earlier exams were supplied for report generation.
SignificanceThe work treated previous exams as an explicit source of information whose contribution could be measured. Its longitudinal data construction and comparisons give researchers a way to assess report-generation methods that incorporate imaging history alongside the index study.
DOI arXiv Full text Fuying WangLequan Yu radiology report generationtransformerMIMIC-CXR
Notable2024arXiv362 citations
MAIRA-2: Grounded Radiology Report Generation
MAIRA-2 took current radiographs and available prior images, reports, and examination context as input. It generated findings and attached bounding boxes to findings that could be localized. The authors introduced RadFact to assess whether report sentences were supported by a reference and to score the accompanying spatial predictions.
SignificanceBy attaching a region to a generated statement, the method made that statement’s proposed image evidence inspectable. RadFact operationalized separate checks on textual agreement and spatial localization, giving follow-up reporting methods evaluation targets for both language and visual grounding.
DOI arXiv Shruthi BannurStephanie L. Hyland vision–language modelradiology report generationobject detectionMIMIC-CXRphrase grounding