annotation
标注
Experts adding labels to medical images: boxes around lesions, voxel-by-voxel organ outlines, or a diagnosis for the whole image. It is the raw material of supervised learning, and the slowest, most expensive step in medical AI.
Annotations come at different granularities: an image-level label (pneumonia or not), a box for object detection, a point, and, most laborious, a pixel-wise outline for image segmentation. Outlining one organ in a 3D CT can mean tracing tens to hundreds of slices, and only trained clinicians can do it. Even experts disagree on boundaries (inter-observer variability), so the reference standard is often built by majority vote or consensus.
There are many ways to spend less. Labels can be mined automatically from radiology reports, as for ChestX-ray14, at the price of label noise. Weakly and semi-supervised methods need fewer detailed labels. And clinicians can edit what a model drafts: in the MedSAM study, two experts annotating adrenal-tumor CT cut their time by 82.37% and 82.95%.
The protocol matters as much as the effort. Whether a tumor outline includes edema, or how small a nodule may be and still count, decides what a model eventually learns.
- Ma J, He Y, Li F, Han L, You C, Wang B. Segment anything in medical images. Nat Commun. 2024;15:654. doi.org/10.1038/s41467-024-44824-z
Key works · 23
Landmark2009CVPR 200987,569 citations
ImageNet: A large-scale hierarchical image database
ImageNet organized web images around WordNet synsets and used crowdsourced verification to check their labels. The paper reported roughly 3.2 million images across 5,247 synsets in 12 subtrees and illustrated their use in classification, object recognition, and automatic image clustering experiments.
SignificanceThe hierarchy and labeled images supported the subsequent ImageNet recognition challenge. Medical imaging researchers also reused ImageNet-trained parameters to initialize models and tested whether transfer improved performance in their target tasks, making the dataset relevant to medical imaging without containing clinical scans.
DOI Jia DengFei-Fei Li ImageNetannotationimage classification
Landmark2010Journal of the American Medical Informatics Association2,314 citations
Mayo clinical Text Analysis and Knowledge Extraction System (cTAKES): architecture, component evaluation and applications
cTAKES implemented clinical text processing as reusable components for finding sentence boundaries, tokenizing and parsing sentences, identifying concepts, and assigning attributes such as negation and status. The paper evaluated individual components and discussed how the resulting annotations could support several applications.
SignificanceThe system offered a common implementation for turning free-text notes into structured clinical concepts and attributes. Its continuation as an Apache project supplied maintained interfaces, documentation, and reusable components for researchers and developers working with clinical narratives.
DOI Full text Guergana K. SavovaChristopher G. Chute annotationclinical natural language processing
Landmark2011Medical Physics3,570 citations
The Lung Image Database Consortium (LIDC) and Image Database Resource Initiative (IDRI): A Completed Reference Database of Lung Nodules on CT Scans
The collection comprised 1,018 thoracic CT cases. Four radiologists independently marked lesions and then reviewed other readers' anonymized marks before finalizing their own. Of 2,669 findings marked as nodules at least 3 mm by any reader, 928 received that mark from all four.
SignificancePreserving reader-level marks allowed studies to account for disagreement when building nodule references. LUNA16 later used a subset of these scans and annotations to create a standardized detection benchmark with shared definitions for candidates and false positives.
DOI Full text Samuel G. ArmatoLaurence P. Clarke LIDC-IDRIcomputed tomographyinter-observer variabilityannotation
Landmark2016MICCAI 2016 (LNCS 9901)10,596 citations
3D U-Net: Learning Dense Volumetric Segmentation from Sparse Annotation
The paper replaces U-Net's convolutions, pooling, and upsampling with three-dimensional operations. The training loss ignores unlabeled voxels, allowing a dense volumetric mask to be learned from sparse slice annotations. The authors demonstrate the approach on microscopy volumes of Xenopus kidney tissue.
SignificanceThe work established a reusable volumetric convolutional baseline and demonstrated a way to train it from sparsely annotated slices. The later nnU-Net framework retains the 3D U-Net family as one of its core options when configuring a model for a new dataset.
DOI arXiv Özgün ÇiçekOlaf Ronneberger 3D U-NetU-Netannotationvoxel
Landmark2018Scientific Data5,286 citations
The HAM10000 dataset, a large collection of multi-source dermatoscopic images of common pigmented skin lesions
The authors harmonized dermatoscopic images from several sources and released 10,015 images of common pigmented lesions. They documented the diagnostic references used for the categories. More than half of lesions had pathology confirmation, with others supported by follow-up, expert consensus, or confocal microscopy.
SignificanceHAM10000 made multisource training data with a shared diagnostic taxonomy accessible through ISIC. The subsequent lesion classification benchmark used these images as training material, allowing different methods to be developed with a common set of categories and examples.
DOI arXiv Full text Philipp TschandlHarald Kittler ISIC archivedermoscopyannotationimage classification
Landmark2019AAAI 20192,359 citations
CheXpert: A Large Chest Radiograph Dataset with Uncertainty Labels and Expert Comparison
CheXpert contained 224,316 radiographs from 65,240 patients, with 14 observations derived from reports and explicit uncertainty labels. The authors compared several different ways of using uncertain observations during training and evaluated the resulting models on studies independently annotated by radiologists.
SignificanceExplicit uncertainty labels gave researchers a shared way to evaluate strategies for handling equivocal report findings during training. The expert-labeled evaluation made it possible to compare interpretations through a benchmark with a reference distinct from the automatically assigned training labels.
DOI arXiv Full text Jeremy IrvinAndrew Y. Ng radiographyweak supervisionannotationuncertainty estimationclinical natural language processing
Landmark2020Radiology: Artificial Intelligence1,789 citations
Checklist for Artificial Intelligence in Medical Imaging (CLAIM): A Guide for Authors and Reviewers
CLAIM presented a reporting checklist for medical imaging studies using machine learning. Its items addressed data sources and partitions, annotation and reference standards, model design and training, and performance evaluation. The paper explained the items for authors preparing reports and for reviewers appraising what was disclosed.
SignificanceThe checklist made imaging-specific details, such as annotation and how imaging data were partitioned, explicit reporting items. The 2024 revision retained that framework and is listed by EQUATOR, with updated guidance on acquisition and testing terminology.
DOI Full text John MonganLinda MoyCharles E. Kahn Jr. annotationground truthexternal validation
Key2014Image Analysis & Stereology1,730 citations
FEEDBACK ON A PUBLICLY DISTRIBUTED IMAGE DATABASE: THE MESSIDOR DATABASE
The paper described the Messidor release of graded fundus photographs intended for lesion detection and diabetic retinopathy assessment. It examined feedback after more than six years of public distribution to characterize how researchers and educators had used a shared ophthalmic image collection.
SignificanceThe released photographs and grades gave researchers a shared reference for retinal lesion and severity assessment. The paper's documentation of uptake also gave a concrete account of how a public ophthalmic dataset supported evaluation beyond the project that acquired the images.
DOI Full text Étienne DecencièreJean-Claude Klein fundus photographyannotation
Key2015International Journal of Computer Vision47,666 citations
ImageNet Large Scale Visual Recognition Challenge
The authors documented the challenge that began in 2010 using images from ImageNet. They described how training and test sets were assembled, how class and bounding-box annotations were checked, and how classification, localization, and detection were scored. They analyzed progress across rounds and compared machine and human performance on a subset.
SignificanceRecurrent evaluation on common tasks and held-out images created a shared basis for comparing advances in large-scale visual recognition. The challenge record documents how convolutional models performed in classification and localization, giving later studies a historical reference for evaluating changes in visual models.
DOI arXiv Full text Olga RussakovskyFei-Fei Li ImageNetgrand challengeannotationimage classificationobject detection
Key2017Scientific Data1,113 citations
A curated mammography data set for use in computer-aided detection and diagnosis research
CBIS-DDSM curated a subset of a digitized screen-film mammography collection. The release provided decompressed images, updated mass segmentations and bounding boxes, and pathology information. It included 753 calcification cases and 891 mass cases with documented training and test partitions for evaluation.
SignificanceDocumenting case selection, lesion annotations, and evaluation splits makes it possible to compare mammographic detection and classification methods on a common collection. TCIA maintains the release and provides images and metadata tables that identify the training and test subsets.
DOI Full text Rebecca Sawyer LeeDaniel L. Rubin computer-aided detection & diagnosismammographyannotationThe Cancer Imaging Archive
Key2017MICCAI 2017 (LNCS 10435)640 citations
Suggestive Annotation: A Deep Active Learning Framework for Biomedical Image Segmentation
This active learning framework used a fully convolutional network to estimate prediction uncertainty and similarity among image regions. It selected informative, representative examples with a set-cover objective. In gland histology and lymph node ultrasound experiments, the method reached competitive segmentation performance with roughly half of the training data.
SignificanceThe study treated the annotation budget as an experimental variable and showed how representativeness could complement uncertainty when selecting a batch. It became an example of combined selection criteria in later surveys of deep active learning for medical image analysis.
DOI arXiv Lin YangDanny Z. Chen annotationimage segmentationuncertainty estimationactive learning
Key2020Medical Image Analysis921 citations
Deep learning with noisy labels: Exploring techniques and remedies in medical image analysis
The authors reviewed sources of label noise in medical imaging and methods for handling them. They compared remedies in three case studies, including fetal brain segmentation. In one experiment, many mildly noisy masks supported better performance than a much smaller set of manual masks, illustrating dependence on the form of the noise.
SignificanceThe review coupled a taxonomy of noisy labels with experiments that compared remedies under different annotation processes. It became a reference for the medical imaging label-noise literature, where both the mechanism producing errors and the clinical task affect whether a mitigation helps.
DOI arXiv Full text Davood KarimiAli Gholipour weak supervisionannotationground truthinter-observer variabilitylabel noise
Key2020Academic Radiology303 citations
Exploring Large-scale Public Medical Image Datasets
The author inspected images in ChestX-ray14 and MURA to assess how their labels corresponded to visible findings. Labels for several chest findings had lower positive predictive value than documentation suggested. In MURA, some positive labels tracked features such as the presence of hardware.
SignificanceThe study moved dataset label quality from a documented assumption to something that could be checked by sampling imagery. Its findings about report-derived chest labels and musculoskeletal abnormality labels show why each benchmark needs a task-specific interpretation.
DOI arXiv Full text Luke Oakden-Rayner ChestX-ray14annotationground truth
Key2020Medical Image Analysis1,021 citations
PadChest: A large chest x-ray image dataset with multi-label annotated reports
PadChest assembled chest radiographs and corresponding Spanish-language reports from a hospital archive. The project used labels for radiographic findings, anatomical locations, and possible diagnoses. Trained annotators labeled a subset of reports, and a model assigned labels to the remaining reports.
SignificanceThe collection broadened the reporting language, geographic source, and label vocabulary represented in public chest radiography data. Later studies have used it alongside other datasets to test whether models retain performance when evaluated on an external institution's examinations.
DOI arXiv Aurelia BustosAntonio PertusaMaría de la Iglesia-Vayá radiographyannotationweak supervision
Key2021NeurIPS 2021 (Datasets and Benchmarks)468 citations
RadGraph: Extracting Clinical Entities and Relations from Radiology Reports
RadGraph defined a schema for annotating anatomy, observations, and relations in chest radiograph reports. Radiologists labeled development reports from MIMIC-CXR and a test set drawn from MIMIC-CXR and CheXpert. The authors released annotated data and trained a model to extract the same structures automatically.
SignificanceThe relation annotations made it possible to compare reports by clinical structure as well as wording. RadGraph F1 later used that structure for evaluating generated reports, and RadGraph-XL extended the resource to additional modalities and anatomical regions.
arXiv Saahil JainPranav Rajpurkar radiology report generationMIMIC-CXRannotationclinical natural language processing
Key2022Scientific Data662 citations
VinDr-CXR: An open dataset of chest X-rays with radiologist’s annotations
VinDr-CXR released 18,000 chest radiographs from two Vietnamese hospitals with manual annotations. Labels included boxes for 22 local findings and six image-level categories. Three radiologists annotated each training image independently, while boxes and labels for the test set used a five-reader consensus.
SignificanceReleased localization labels provide a reference for evaluating where a detector marks findings on the image. The documented institutions, annotation process, and training and test partitions also make VinDr-CXR useful for assessment alongside collections originating elsewhere.
DOI arXiv Full text Ha Q. NguyenHieu H. PhamVan Vu radiographyobject detectionannotationinter-observer variability
Key2023Scientific Data1,487 citations
MedMNIST v2 - A large-scale lightweight benchmark for 2D and 3D biomedical image classification
MedMNIST v2 standardized 12 two-dimensional and six three-dimensional datasets for lightweight classification. It provided uniformly small inputs, labels, and dataset partitions for tasks including binary, multiclass, and multilabel prediction. The paper reported several classification baseline results and released data and code.
SignificanceStandardized inputs and published partitions made it easier to run comparable classifications across imaging sources. The project provides a common download and evaluation interface, supporting repeatable classification experiments on small-scale two- and three-dimensional benchmark tasks.
DOI arXiv Full text Jiancheng YangBingbing Ni image classificationannotation
Key2024Radiology: Artificial Intelligence1,057 citations
Checklist for Artificial Intelligence in Medical Imaging (CLAIM): 2024 Update
The 2024 CLAIM update revised imaging-specific reporting items through expert review, including describing acquisition protocols and clarifying terms for reference standards, internal testing, and external testing. The article explains the scope of the checklist and how each item relates to transparent reporting of imaging studies.
SignificanceRequiring acquisition details makes it easier to assess whether experiments can be reproduced or compared across scanners and protocols. EQUATOR catalogs the updated version, which gives authors and reviewers a shared checklist for the information needed to interpret an imaging study.
DOI Full text Ali Shah TejaniCharles E. Kahn Jr. annotationground truthexternal validation
Key2025arXiv
HealthBench: Evaluating Large Language Models Towards Improved Human Health
HealthBench assembled 5,000 simulated health conversations, including both single-turn and multi-turn examples. A group of 262 physicians contributed case-specific criteria for assessing answers on dimensions including accuracy, completeness, and communication. A subset of consensus criteria was used to test agreement between automated scores and physician ratings.
SignificanceCase-specific criteria made open-ended health answers comparable along clinically defined dimensions. HealthBench Consensus retains criteria that multiple physicians agreed applied to the example and provides physician judgments for checking the automated grader. An independent study used a HealthBench sample alongside real clinician queries.
DOI arXiv Rahul K. AroraKaran Singhal large language modelannotation
Notable2021IEEE Transactions on Medical Imaging153 citations
Learning to Segment From Scribbles Using Multi-Scale Adversarial Attention Gates
This method used scribble annotations to guide target location and unrelated complete masks to train a multiscale adversarial shape constraint. Attention gates passed the adversarial signal to the segmentation network. Across experiments including cardiac and abdominal imaging, scribble-trained models could attain performance comparable to models trained with complete masks.
SignificanceThe authors released expert scribbles for the ACDC cardiac MRI dataset along with the experimental code. The shared annotations gave subsequent scribble-supervised work a common way to compare methods on the same cases and with the same type of weak annotation.
DOI arXiv Full text weak supervisionannotationgenerative adversarial networkimage segmentation
Notable2022The Journal of Machine Learning for Biomedical Imaging8 citations
Continual Active Learning Using Pseudo-Domains for Limited Labelling Resources and Changing Acquisition Characteristics
The method grouped incoming images into pseudo-domains by acquisition characteristics, selected examples under a labeling budget, and rehearsed stored examples to limit forgetting. Across cardiac segmentation, lung nodule detection, and brain age estimation, it improved on active-learning comparators tested on streams containing domain shifts.
SignificanceThe experimental design combined scanner or protocol changes with the cost of continuously seeking expert labels. Evaluating several tasks under a shared streaming setup made it possible to examine whether a model can acquire new capabilities while retaining performance on earlier acquisition conditions.
DOI arXiv Full text domain shiftannotationactive learningcontinual learning
Notable2024Findings of ACL 202489 citations
RadGraph-XL: A Large-Scale Expert-Annotated Dataset for Entity and Relation Extraction from Radiology Reports
RadGraph-XL extended report annotation to chest radiographs, chest CT, abdominal and pelvic CT, and brain MRI. Radiologists annotated more than 410,000 entities and relations across 2,300 reports. The study trained extraction models and included an expert review on out-of-domain reports.
SignificanceThe dataset made structured extraction from reports an evaluation problem spanning several anatomies and modalities. The trained models and the MIMIC subset released through PhysioNet support tests of whether methods established for chest radiographs transfer to other report types.
DOI Full text Jean-Benoit DelbrouckCurtis P. Langlotz radiology report generationannotationtransformerclinical natural language processing
Notable2026Radiology: Artificial Intelligence0 citations
Checklist for Artificial Intelligence in Medical Imaging (CLAIM): Explanation, Elaboration, and Examples
This companion explains all 44 items of the 2024 CLAIM update, including the rationale for each item, common misinterpretations, and how to apply it. An appendix and online tool illustrate the items with published studies across data sourcing, model development, testing, and reporting.
SignificanceThe examples make it easier for authors and reviewers to apply the checklist consistently to a manuscript. EQUATOR indexes the paper with the 2024 checklist, and the RSNA's interactive resource makes the accompanying explanations and examples accessible for each item.
DOI Tugba Akinci D’AntonoliJohn Mongan annotationexternal validation