voxel
体素
The 3D counterpart of a pixel: a small box of tissue represented by one number. Every value in a CT or MRI volume is an average over its voxel, so large voxels blend different tissues together.
CT and MRI produce a stack of slices, and each pixel in them really stands for a small block with thickness. A chest CT with a 35 cm field of view and a 512 matrix has voxels about 0.68 mm across in-plane, times the slice thickness. Voxels with equal sides are called isotropic and look equally sharp when re-sliced in any direction (multiplanar reconstruction); the 1 × 1 × 5 mm voxels common in older MRI turn into staircases when viewed from the side.
A voxel's value is the average of everything inside it. A 3 mm nodule occupying part of a 5 mm thick voxel is diluted by surrounding lung, so it looks fainter and smaller than it is. This partial-volume effect is a classic cause of missed small lesions and biased measurements.
Smaller voxels bring detail and lose signal. In MRI, other things equal, the signal-to-noise ratio scales with voxel volume: halve each side and the volume, and roughly the SNR, drops to one eighth, which only longer scanning can buy back.
Key works · 18
Landmark1986Radiology4,375 citations
MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders
The authors used gradient pulses to measure spin-echo attenuation associated with diffusion and microcirculation within individual voxels. Measurements in water and acetone phantoms reproduced known diffusion values, and estimates of apparent diffusion in neurologic images differed between several normal and pathologic tissues.
SignificanceThe work established a way to map apparent diffusion in human tissue and introduced intravoxel incoherent motion as an imaging measurement. Subsequent tensor imaging used diffusion encoding in multiple directions to characterize anisotropy as well as overall diffusion magnitude.
DOI Denis Le BihanMaurice Laval-Jeantet diffusion MRIvoxelgradient coilspin echo
Landmark1987SIGGRAPH 198712,195 citations
Marching cubes: A high resolution 3D surface construction algorithm
The algorithm visits cells of eight neighboring samples, selects a triangle configuration according to the samples' relationship to an isovalue, and interpolates vertex positions along cell edges. The authors used local gradients for shading and demonstrated the resulting surfaces with CT, MRI, and SPECT data.
SignificanceThe case table and interpolation made isosurface extraction a practical cell-by-cell operation that produced triangular meshes from medical volumes. The Visualization Toolkit later made the method available as a reusable component for extracting surfaces from volume data.
DOI Full text William E. LorensenHarvey E. Cline marching cubessurface renderingvoxelinterpolationisosurface
Landmark1988IEEE Computer Graphics and Applications2,732 citations
Display of surfaces from volume data
Levoy computed voxel shading from local gradients and separately assigned opacity according to a surface classification rule. Combining the shaded samples along each viewing ray produced a surface depiction directly from a three-dimensional array, with examples drawn from medical and molecular data.
SignificanceSeparating shading, classification, and ray compositing gave visualization systems a way to adjust the displayed structures while rendering directly from sampled volumes. Later acceleration work retained voxel classification and compositing while reducing the time required to generate each view.
DOI Full text Marc Levoy volume renderingsurface renderingvoxelisosurface
Landmark1988ACM SIGGRAPH Computer Graphics1,806 citations
Volume rendering
The authors assigned different optical and color properties to materials and their boundaries and computed images by simulating absorption along view rays. The procedures addressed aliasing and quantization artifacts, and the paper illustrated the rendering method on several kinds of volumetric data, including medical images.
SignificanceThis approach made it possible to show several structures and their occlusion relationships from one volume, with optical properties controlling which materials were emphasized. Clinical CT angiography later used related volume-rendering methods to depict vessels alongside relevant surrounding anatomy.
DOI Full text Robert A. DrebinPat Hanrahan volume renderingvoxelaliasing
Landmark1996Journal of the American Medical Informatics Association779 citations
The Visible Human Male: A Technical Report
The report documented how the National Library of Medicine's Visible Human Male data were produced. MRI, CT, and photographs of serial cryosections were acquired from the same cadaver. The authors described specimen selection, image production, and the resulting collection of about 15 gigabytes.
SignificanceImaging and physical sections from the same specimen provided a common reference for volumetric anatomy. The National Library of Medicine documents reuse of Visible Human data for anatomical teaching resources, three-dimensional reconstruction, and research on processing medical images.
DOI Full text Victor Michael SpitzerDavid Whitlock Visible Human Projectvoxelsurface rendering
Landmark2016MICCAI 2016 (LNCS 9901)10,596 citations
3D U-Net: Learning Dense Volumetric Segmentation from Sparse Annotation
The paper replaces U-Net's convolutions, pooling, and upsampling with three-dimensional operations. The training loss ignores unlabeled voxels, allowing a dense volumetric mask to be learned from sparse slice annotations. The authors demonstrate the approach on microscopy volumes of Xenopus kidney tissue.
SignificanceThe work established a reusable volumetric convolutional baseline and demonstrated a way to train it from sparsely annotated slices. The later nnU-Net framework retains the 3D U-Net family as one of its core options when configuring a model for a new dataset.
DOI arXiv Özgün ÇiçekOlaf Ronneberger 3D U-NetU-Netannotationvoxel
Landmark20163DV 201615,423 citations
V-Net: Fully Convolutional Neural Networks for Volumetric Medical Image Segmentation
V-Net uses a fully convolutional, residual architecture that predicts a prostate mask from an MRI volume. It optimizes an objective based on the Dice coefficient to address foreground-background imbalance. The training data are augmented with nonlinear spatial transformations and histogram matching.
SignificanceV-Net provided a reproducible example of optimizing volumetric overlap directly and of organizing volumetric residual blocks in an encoder-decoder. Dense V-Networks explicitly extend the V-shaped design with dense connectivity for the simultaneous segmentation of multiple abdominal structures.
DOI arXiv Fausto MilletariSeyed-Ahmad Ahmadi V-NetDice coefficientmagnetic resonance imagingvoxel
Key1977Journal of Computer Assisted Tomography155 citations
Display of Three-Dimensional Information in Computed Tomography
The authors assembled transverse CT slices into a three-dimensional array and developed software to display a section through that array in an arbitrary orientation. They also demonstrated how to detect an organ boundary and display the isolated structure as a surface.
SignificanceThe study showed that one CT volume could be resampled outside the acquired orientation and also used to depict an organ surface. Both capabilities became functions of subsequent medical workstations for multiplanar reformatting and surface display.
DOI Gábor T. HermanHsun Kao Liu computed tomographyvoxelmultiplanar reconstructionsurface rendering
Key1979Computer Graphics and Image Processing468 citations
Three-dimensional display of human organs from computed tomograms
The authors approximated organ surfaces from CT with small square faces of restricted orientation and adapted a depth buffer to remove hidden surfaces efficiently. They applied low-pass filtering to reduce artifacts from the square approximation and demonstrated the method with actual patient-derived organ volumes.
SignificanceThe work showed that voxel boundaries could be rendered as visible faces for three-dimensional inspection of organs imaged by CT. Drebin and colleagues later described this square-face model when comparing existing surface methods with direct volume rendering.
DOI Gábor T. HermanHsun Kao Liu computed tomographysurface renderingvoxel
Key1982American Association of Physicists in Medicine57 citations
A Standard Format for Digital Image Exchange
The AAPM task force proposed a magnetic-tape interchange format in which multidimensional raster arrays are stored as sequential files. An opening directory records descriptive information in readable key-value pairs. The format worked within existing specifications for recorded magnetic tape and tape labels.
SignificanceThe report documents an early formal proposal for exchanging digital medical images across systems and treating image arrays and descriptive information as parts of the same interchange structure. The later DICOM specification also made this relationship explicit for networked imaging systems.
DOI Full text Brent S. BaxterGerald Q. Maguire Jr. pixelvoxelpicture archiving and communication system
Key1984Radiology497 citations
Three dimensional CT reconstruction images for craniofacial surgical planning and evaluation
The authors reconstructed three-dimensional bone and soft tissue surfaces from high-resolution CT contours and adapted computer-aided design methods to complex craniofacial cases. They showed how those surfaces could delineate abnormal anatomy, support surgical planning, and assist quantitative evaluation after surgery.
SignificanceThe work brought CT-derived surface models into preoperative and postoperative craniofacial assessment. Follow-up studies showed how clinicians could view skull reconstructions from different directions and selectively hide structures to inspect anatomical relationships obscured in an external view.
DOI Michael W. VannierJ. O. Warren surface renderingcomputed tomographyvoxelthree-dimensional surgical planning
Key1990Journal of Digital Imaging271 citations
Real time volumetric ultrasound imaging system
The authors used a 289-element two-dimensional phased array to scan a pyramidal volume with pulse echoes. Parallel processing on reception produced approximately eight volume acquisitions per second and also let the system display sections selected from the acquired three-dimensional data.
SignificanceThe prototype combined a two-dimensional array, parallel reception, and section display from acquired volumes to show how rapidly changing anatomy could be scanned in three dimensions. Later real-time three-dimensional echocardiography developed this approach using matrix-array transducers.
DOI Full text Olaf T. von RammStephen W. Smith ultrasound imagingbeamformingtransducertemporal resolutionvoxel
Key1994SIGGRAPH 19941,159 citations
Fast volume rendering using a shear-warp factorization of the viewing transformation
The authors factored the viewing transformation into a three-dimensional shear aligned with the data slices and a two-dimensional warp of an intermediate projection. Traversing the volume and intermediate image in synchrony, with run-length encoding to skip regions, accelerated rendering on contemporary workstations.
SignificanceAligning voxel rows with intermediate image rows reduced the work needed to generate a new view. A subsequent parallel implementation retained the factorization and increased the rate at which medical volumes could be rendered for interactive inspection.
DOI Full text Philippe LacrouteMarc Levoy volume renderingvoxelinterpolation
Key2020Medical Image Analysis570 citations
Exploring uncertainty measures in deep networks for Multiple sclerosis lesion detection and segmentation
The authors use Monte Carlo dropout to estimate uncertainty for multiple sclerosis lesions in MRI and compare scores at the voxel and lesion scales. Filtering uncertain predictions improved detection performance among retained predictions. The smallest lesions and lesion boundaries showed the most uncertainty.
SignificanceThe study treats uncertainty at the lesion level as an output that can help prioritize review. It compares several ways to derive that output, and a later medical image uncertainty survey describes it as an example of Monte Carlo dropout for lesion segmentation.
DOI arXiv Tanya NairTal Arbel uncertainty estimationmagnetic resonance imagingimage segmentationvoxeldropout
Key2022arXiv1,683 citations
MONAI: An open-source framework for deep learning in healthcare
The report describes MONAI, a collection of medical-imaging components built on PyTorch. It provides spatially aware transforms, domain-specific networks and losses, and tools for inference. Users can compose these pieces into training and deployment workflows maintained by a cross-institutional open-source project.
SignificanceMONAI made transforms that preserve imaging geometry and operations such as sliding-window inference available in a shared library. The project also publishes model bundle specifications, so workflows such as Swin UNETR can distribute preprocessing, postprocessing, and weights together.
DOI arXiv M. Jorge CardosoWenqi LiSébastien OurselinAndrew Feng MONAIvoxeldata augmentationimage segmentation
Key2022WACV 20224,964 citations
UNETR: Transformers for 3D Medical Image Segmentation
UNETR tokenizes a three-dimensional scan into patches, encodes them with a transformer, and transfers representations at different encoder depths to a convolutional decoder that restores voxel resolution. It was assessed on abdominal multi-organ CT and on brain tumor and spleen segmentation tasks.
SignificanceThe work turned a ViT-style encoder and a U-shaped decoder into a practical design for volumetric segmentation. Swin UNETR keeps that broad structure and substitutes a hierarchical shifted-window encoder to obtain spatial features at several scales.
DOI arXiv Full text Ali HatamizadehDaguang Xu vision transformerU-Netskip connectionvoxelmulti-organ segmentation
Key2023MICCAI 2023 (LNCS 14223)752 citations
MedNeXt: Transformer-Driven Scaling of ConvNets for Medical Image Segmentation
MedNeXt adapts large-kernel ConvNeXt-style blocks to a volumetric encoder-decoder. The authors scale depth, width, and kernel size and propose initializing larger kernels from trained smaller ones. Experiments across several volumetric segmentation datasets compare how changing each dimension affects predictive performance.
SignificanceMedNeXt supplied a large-kernel convolutional comparison for contemporary three-dimensional attention models. The subsequent nnU-Net Revisited study evaluates modern convolutional alternatives, including ConvNeXt-style variants, within a standardized training framework to examine the effects of architecture and scale.
DOI arXiv Saikat RoyKlaus H. Maier-Hein convolutional neural networkimage segmentationencoder–decodervoxelweight initialization
Notable2017MICCAI 2017 (LNCS 10434)287 citations
Automatic 3D Cardiovascular MR Segmentation with Densely-Connected Volumetric ConvNets
DenseVoxNet uses densely connected volumetric convolutional blocks so later layers can reuse earlier voxel features. The authors apply the resulting compact network to cardiovascular MRI and compare the segmentation of the myocardium and blood pool with prior methods using the HVSMR 2016 benchmark.
SignificanceThis work illustrates the transfer of DenseNet-style feature reuse from recognition to three-dimensional cardiac delineation. Its comparisons put model size alongside blood-pool and myocardium segmentation performance on the same dataset, a practical issue when labeled volumes are scarce.
DOI arXiv Lequan YuPheng-Ann Heng fully convolutional networkmagnetic resonance imagingvoxelimage segmentationdense connectivity