magnetic resonance imagingMRI
磁共振成像
Imaging with a strong magnet, radio pulses and field gradients: hydrogen nuclei in the body's water and fat emit a faint radio signal, and the gradients encode where it came from. No ionizing radiation, and far better soft-tissue contrast than CT.
Inside a 1.5 or 3 tesla magnet, hydrogen nuclei in the body's water and fat line up with the field and precess at the Larmor frequency, about 64 MHz at 1.5 T. A radio pulse tips them over, and as they recover they emit a faint signal. Gradient coils make its frequency and phase depend on position, so the signal fills k-space and a Fourier transform turns it into an image. Tissues differ in T1, T2 and proton density, so the timing of the sequence determines which contrast the image shows.
Paul Lauterbur published the gradient idea in Nature in 1973; Peter Mansfield developed slice selection and fast imaging, and the two shared the 2003 Nobel Prize in Physiology or Medicine. Raymond Damadian had reported in 1971 that tumors relax more slowly, and in 1977 scanned the first human body with his home-built Indomitable.
The price is time and space. An examination often takes 15–45 minutes inside a narrow, loud bore, and because the magnet is always on, metal implants and some pacemakers must be screened before anyone goes near it.
- Lauterbur PC. Image formation by induced local interactions: examples employing nuclear magnetic resonance. Nature. 1973;242:190–191. doi.org/10.1038/242190a0
- Damadian R. Tumor detection by nuclear magnetic resonance. Science. 1971;171(3976):1151–1153. doi.org/10.1126/science.171.3976.1151
- The Nobel Prize in Physiology or Medicine 2003 — press release. www.nobelprize.org/prizes/medicine/2003/press-release/
Key works · 53
Landmark1973Nature5,033 citations
Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance
Lauterbur applied a linear magnetic field gradient so that proton resonance frequency depended on position. He recorded projections with the gradient oriented in different directions and combined them to reconstruct a two-dimensional image that resolved two water-filled tubes immersed in heavy water.
SignificanceThe work showed how to recover a two-dimensional image from nuclear magnetic resonance signals by deliberately encoding position. Gradient-based spatial encoding became a fundamental principle of MRI and was recognized in the scientific background for the 2003 Nobel Prize in Physiology or Medicine.
DOI Paul C. Lauterbur magnetic resonance imagingnuclear magnetic resonancegradient coilprojectionback-projection
Landmark1975Journal of Magnetic Resonance881 citations
NMR Fourier zeugmatography
The authors applied sequences of pulsed magnetic field gradients during a series of free induction decays to encode the spatial frequency components of spin density. A multidimensional Fourier transform reconstructed the image. The paper set out how the gradient pulses and measurement timing determined which components were acquired.
SignificanceDirect Fourier sampling offered a framework for combining frequency encoding with repeated phase encoding. The subsequent spin-warp method adapted Fourier encoding for routine image acquisition, establishing an approach that remains central to conventional clinical magnetic resonance imaging.
DOI Full text Anil KumarRichard R. Ernst Fourier transformgradient coilk-spacemagnetic resonance imagingphase encoding
Landmark1980Physics in Medicine and Biology952 citations
Spin warp NMR imaging and applications to human whole-body imaging
The Aberdeen group described spin-warp imaging, in which a gradient encodes phase with a different amplitude on successive excitations and a readout gradient encodes frequency. They presented examples of human imaging with the sequence using a 0.04 tesla magnet large enough to accommodate the body.
SignificanceSpin-warp imaging made slice selection and Fourier encoding practical in a sequence for human scanning. Aberdeen subsequently used its system to scan a patient, and the method's line-by-line acquisition of spatial frequency data became a standard approach in clinical MRI.
DOI William A. EdelsteinT. W. Redpath magnetic resonance imagingk-spacegradient coilFourier transformphase encodingfrequency encoding
Landmark1986Journal of Magnetic Resonance1,492 citations
FLASH imaging. Rapid NMR imaging using low flip-angle pulses
FLASH used small flip-angle radio-frequency pulses to retain longitudinal magnetization for the next excitation, allowing successive measurements at short intervals. The sequence reversed the readout gradient to generate an echo. Demonstrated acquisition times were about one second for 64 by 128 pixels and six seconds for 256 by 256.
SignificanceCombining small excitations with gradient echoes established a way to speed MRI by shortening the repetition interval. Kose’s technical history traces the development of fast T1-weighted imaging from FLASH to later sequences that used radio-frequency spoiling to control residual transverse magnetization.
DOI Full text Axel HaaseJens FrahmKlaus-Dietmar Merboldt magnetic resonance imagingRF pulsetemporal resolution
Landmark1986Magnetic Resonance in Medicine2,345 citations
RARE imaging: A fast imaging method for clinical MR
The team assigned a different phase-encoding step to each of several spin echoes following excitation, collecting enough data for a 256 by 256 image in 2 to 40 seconds. They examined artifacts caused by changing T2 weighting across the echo train and how phase-encoding order could reduce them.
SignificanceAcquiring multiple k-space lines from a train of refocused echoes became the basis of clinical fast or turbo spin-echo imaging. Later implementations retained this approach to accelerating T2-weighted acquisitions while addressing the blurring and radio-frequency demands of long echo trains.
DOI Jürgen HennigHartmut Friedburg magnetic resonance imagingT2 relaxationk-spacespin echophase encoding
Landmark1990Proceedings of the National Academy of Sciences8,190 citations
Brain magnetic resonance imaging with contrast dependent on blood oxygenation
The authors used high-field gradient echoes to observe brain microvasculature in live animals, exploiting the paramagnetism of deoxygenated hemoglobin. Image contrast changed when anesthesia, hypoglycemia, or inhaled gases altered physiology. The team named the effect blood oxygenation level-dependent, or BOLD, contrast.
SignificanceBOLD supplied an endogenous source of magnetic susceptibility contrast linked to blood oxygenation. Subsequent human visual stimulation experiments used that mechanism to localize task-related responses, establishing the signal used in a large share of functional MRI studies.
DOI Full text Seiji OgawaDavid W. Tank BOLD signalfunctional MRImagnetic resonance imaging
Landmark1990Magnetic Resonance in Medicine2,653 citations
The NMR phased array
The authors reduced coupling among receiving coils by overlapping neighboring coils and using low-input-impedance preamplifiers. They derived a rule for combining coil data to maximize signal-to-noise ratio. Two four-element arrays yielded twofold and threefold gains at the depth of the spine compared with one large coil under matched imaging conditions.
SignificanceThe receive array provided broad coverage while preserving separate measurements from local coils. Both SMASH and SENSE cited the array work and used differences among coil sensitivities as spatial encoding, turning those separate measurements into a means of accelerating acquisition.
DOI Peter B. RoemerWilliam A. EdelsteinO. M. Mueller magnetic resonance imagingsignal-to-noise ratioparallel imaging
Landmark1999IEEE Transactions on Medical Imaging5,930 citations
Nonrigid registration using free-form deformations: application to breast MR images
The method modeled global breast motion with an affine transform and local deformation with B-spline control points. It optimized normalized mutual information with a smoothness penalty. In three-dimensional contrast-enhanced MRI from volunteers and patients, it recovered deformation more effectively than the rigid and affine registrations tested.
SignificanceThe work demonstrated a practical combination of a B-spline control grid and a voxel-based matching criterion. B-spline free-form deformation became a reference transformation family in medical registration and is configurable in modular tools such as elastix.
DOI Daniel RueckertDavid J. Hawkes image registrationmutual informationmagnetic resonance imaging
Landmark2005Alzheimer's & Dementia1,399 citations
Ways toward an early diagnosis in Alzheimer's disease: The Alzheimer's Disease Neuroimaging Initiative (ADNI)
The paper described ADNI's plan to follow participants with normal cognition, mild cognitive impairment, or early Alzheimer's disease. Repeated MRI, PET, fluid biomarkers, and clinical assessments were to be combined to investigate markers for identifying and monitoring early Alzheimer’s disease across visits.
SignificanceADNI provided a way to examine longitudinal imaging and clinical measures together across participating sites. Its data portal supports research access, enabling tests of candidate biomarkers across modalities or visits from the same study participants.
DOI Full text Susanne G. MuellerMichael Walter WeinerLaurel A. Beckett ADNImagnetic resonance imagingpositron emission tomography
Landmark2013NeuroImage6,502 citations
The WU-Minn Human Connectome Project: An overview
The WU-Minn Human Connectome Project planned multimodal data collection for approximately 1,200 healthy young adults. The overview described structural, functional, and diffusion MRI alongside behavioral measures, set out processing and sharing plans, and presented initial examples of functional connectivity analyses.
SignificanceCommon acquisitions and processing made it possible to study functional and structural connectivity in the same population. Later releases through ConnectomeDB, with associated analysis tools, provided a resource for comparing and repeating network analyses on shared multimodal data.
DOI Full text David C. Van EssenKâmil Uğurbil magnetic resonance imagingfunctional MRIdiffusion MRI
Landmark2015IEEE Transactions on Medical Imaging8,349 citations
The Multimodal Brain Tumor Image Segmentation Benchmark (BRATS)
The paper reported the 2012 and 2013 brain tumor segmentation challenges, comparing 20 algorithms on 65 clinical multicontrast scans and 65 simulated scans. Human rater agreement for tumor subregions ranged from 74% to 85% Dice, and methods ranked differently across subregions.
SignificanceBraTS established shared multimodal inputs, tumor subregion labels, and evaluation for glioma segmentation. Subsequent rounds extended the data and benchmark while retaining common tasks, allowing successive methods to be compared within a sustained challenge series.
DOI Full text Bjoern H. MenzeKoen Van Leemput BraTSgrand challengemagnetic resonance imagingimage segmentationDice coefficientinter-observer variability
Landmark2016Nature Neuroscience2,190 citations
Multimodal population brain imaging in the UK Biobank prospective epidemiological study
The paper described the UK Biobank's multimodal brain MRI protocol and the analysis of the first roughly 5,000 imaged participants. It derived structural, functional, and diffusion measures and related selected imaging phenotypes to other participant information as demonstrations of population analysis.
SignificanceStandardized imaging and derived measures made it possible to link brain phenotypes with health, behavioral, and genetic information in a large cohort. UK Biobank provides access through research applications so independent investigations can reuse the same underlying measurements.
DOI Full text Karla L. MillerStephen M. Smith UK Biobankmagnetic resonance imagingfunctional MRIdiffusion MRI
Landmark20163DV 201615,423 citations
V-Net: Fully Convolutional Neural Networks for Volumetric Medical Image Segmentation
V-Net uses a fully convolutional, residual architecture that predicts a prostate mask from an MRI volume. It optimizes an objective based on the Dice coefficient to address foreground-background imbalance. The training data are augmented with nonlinear spatial transformations and histogram matching.
SignificanceV-Net provided a reproducible example of optimizing volumetric overlap directly and of organizing volumetric residual blocks in an encoder-decoder. Dense V-Networks explicitly extend the V-shaped design with dense connectivity for the simultaneous segmentation of multiple abdominal structures.
DOI arXiv Fausto MilletariSeyed-Ahmad Ahmadi V-NetDice coefficientmagnetic resonance imagingvoxel
Landmark2018IEEE Transactions on Medical Imaging1,499 citations
A Deep Cascade of Convolutional Neural Networks for Dynamic MR Image Reconstruction
A cascade alternated convolutional corrections with enforcement of consistency with acquired k-space samples. For dynamic cardiac MRI, neighboring frames also provided information for joint reconstruction. In the authors' undersampling experiments the method better preserved anatomy than the reported comparators and reconstructed complete sequences in under ten seconds.
SignificanceThe cascade was an influential example of pairing learned corrections with repeated data consistency steps. It also demonstrated how temporal information could supplement undersampled measurements. Later experimental reviews of MRI reconstruction retained cascaded networks as a distinct comparison class.
DOI arXiv Jo SchlemperDaniel Rueckert magnetic resonance imagingk-spacedeep-learning reconstructiondeep unrollingdata consistency
Landmark2020Radiology: Artificial Intelligence606 citations
fastMRI: A Publicly Available Raw k-Space and DICOM Dataset of Knee Images for Accelerated MR Image Reconstruction Using Machine Learning
The fastMRI knee release provided multicoil raw k-space measurements from 1,594 examinations and a separate collection of clinical DICOM image series. Its vendor-neutral measurement format made retrospective undersampling and comparison against fully sampled reconstructions possible using common data instead of locally acquired raw scans.
SignificanceFastMRI supported reproducible comparisons by making measurements available alongside reference images. The 2019 knee challenge used this release, and the later brain challenge broadened the benchmark to include pathology-centered reader evaluations and a track for scanners outside the training data.
DOI Full text Florian KnollJure ZbontarYvonne W. Lui fastMRIk-spacemagnetic resonance imaginggrand challenge
Key1974Journal of Physics C: Solid State Physics370 citations
Image formation in NMR by a selective irradiative process
The authors combined switched magnetic field gradients with frequency-selective radio-frequency irradiation to excite or saturate spins in chosen parts of a sample. They reported preliminary experiments illustrating the components of the method and produced a two-dimensional image of a simple object.
SignificanceApplying a selective pulse in a gradient made it possible to prescribe the slice to be imaged. Spin-warp imaging combined this form of slice selection with frequency and phase encoding, a combination that became standard in clinical two-dimensional MRI.
DOI Allen N. GarrowayPeter Mansfield RF pulsegradient coilmagnetic resonance imaging
Key1992Neurology962 citations
Fast magnetic resonance diffusion-weighted imaging of acute human stroke
The authors used rapid diffusion-weighted MRI in patients with cerebral infarction and compared the findings with conventional T2-weighted spin-echo images. Diffusion weighting revealed some infarcts earlier than the conventional sequence, and acute lesions showed lower apparent diffusion coefficients than unaffected regions.
SignificanceThe patient study connected early changes in water diffusion during cerebral ischemia with lesion detection in human stroke. In 1995, the group extended the clinical work to whole-brain echo-planar imaging in 40 patients and confirmed that early diffusion abnormalities could precede changes visible on conventional MRI.
DOI Steven WarachRobert R. Edelman magnetic resonance imagingdiffusion MRIT2 relaxation
Key1992Magnetic Resonance in Medicine1,842 citations
Perfusion imaging
The authors used radio-frequency pulses at 4.7 tesla to saturate water protons in arterial blood flowing toward the rat brain. They compared the resulting images with a distal saturation control to estimate regional cerebral blood flow, and detected changes associated with raised arterial carbon dioxide.
SignificanceThe rat experiment demonstrated quantitative perfusion imaging using arterial water as an endogenous tracer. This measurement principle is central to arterial spin labeling. A 2015 consensus from the ISMRM perfusion group and the European consortium for ASL in dementia gave implementation guidance for clinical MRI.
DOI John A. DetreAlan P. Koretsky magnetic resonance imagingT1 relaxationRF pulse
Key1993IEEE Nuclear Science Symposium and Medical Imaging Conference 19931,660 citations
3D statistical neuroanatomical models from 305 MRI volumes
The authors constructed a stereotaxic reference from 305 brain MRI volumes aligned to a Talairach-like coordinate system and averaged into a common image. They described an automated image-matching procedure and illustrated how a common frame could support analysis of anatomical and functional brain images across people.
SignificanceMNI305 made an average three-dimensional MRI available as a registration target. McGill distributes it as a stereotaxic registration model, and later ICBM template work documented its relationship to MNI305 space, enabling comparisons among studies that used different generations of the reference.
DOI Full text Alan C. EvansTerry M. Peters image registrationmagnetic resonance imaging
Key2007Journal of Cognitive Neuroscience2,568 citations
Open Access Series of Imaging Studies (OASIS): Cross-sectional MRI Data in Young, Middle Aged, Nondemented, and Demented Older Adults
The first OASIS release contained cross-sectional T1-weighted brain MRI from 416 adults, with repeated scans within sessions and a separate test–retest subset. The authors demonstrated the data by estimating brain and intracranial volumes and examining how measurements varied with aging and dementia.
SignificanceThe cross-sectional release made shared structural MRI available for studying anatomical variation with aging and dementia, and the repeat scans supported reliability analyses. OASIS subsequently added longitudinal and multimodal releases while maintaining access to the initial collection.
DOI Daniel S. MarcusRandy L. Buckner magnetic resonance imaging
Key2008Journal of Magnetic Resonance Imaging5,008 citations
The Alzheimer's disease neuroimaging initiative (ADNI): MRI methods
The ADNI MRI core optimized and compared candidate three-dimensional T1-weighted sequences across scanner platforms. The published protocol included duplicate magnetization-prepared acquisitions, field calibration where appropriate, and a dual-contrast sequence for detection of other pathology, balancing longitudinal measurement needs and the burden of scanning.
SignificanceThe protocol documented how a large multicenter cohort harmonized acquisitions across MRI platforms. ADNI continues to publish scanner-specific protocols, giving longitudinal morphometry studies a reference for acquisition and calibration choices behind the images they analyze.
DOI Full text Clifford R. JackMichael Walter Weiner ADNImagnetic resonance imaging
Key2009NeuroImage2,487 citations
Evaluation of 14 nonlinear deformation algorithms applied to human brain MRI registration
The authors compared 14 nonlinear algorithms using 80 manually labeled brain scans and more than 45,000 registrations with common linear initialization. They compared alignment using overlap and distance measures. ART and SyN were in the top statistical rank across all four label sets and ranking analyses.
SignificanceThe shared scans, preprocessing, and anatomical labels enabled direct comparison across registration software. A subsequent evaluation of volume and surface registration used the results to select ART and SyN for the volume-based comparisons, carrying the benchmark into a different experimental design.
DOI Full text Arno KleinRamin V. Parsey image registrationmagnetic resonance imagingground truth
Key2011NeuroImage2,658 citations
Unbiased average age-appropriate atlases for pediatric studies
The authors constructed age-specific templates from pediatric and adult MR images, using iterative nonlinear registration to estimate average anatomy and normalized intensity. The resulting resources included symmetric and asymmetric templates and were made compatible with a new ICBM152 stereotaxic space.
SignificanceAge-appropriate templates provided registration targets that reflect the anatomy of developing brains. Making the templates available in a documented stereotaxic framework let separate studies use the same reference resources when processing and comparing pediatric MRI.
DOI Full text Vladimir FonovD. Louis Collins image registrationmagnetic resonance imaging
Key2014Medical Image Analysis1,055 citations
Evaluation of prostate segmentation algorithms for MRI: The PROMISE12 challenge
The PROMISE12 challenge compared 11 prostate segmentation methods on T2-weighted MRI acquired across centers, scanners, and protocols. It used expert outlines as a reference and applied common overlap and boundary measures, examining the results across different parts of the prostate and data sources.
SignificanceThe benchmark made scanner and protocol variation part of the prostate segmentation evaluation. Its public challenge site retains the evaluation protocol and results, providing a reference for comparing algorithms on shared data from multiple acquisition settings.
DOI Full text Geert LitjensAnant Madabhushi grand challengeimage segmentationmagnetic resonance imaging
Key2017Medical Image Analysis671 citations
3D deeply supervised network for automated segmentation of volumetric medical images
This work adds auxiliary segmentation losses at intermediate layers of a 3D fully convolutional network so that shallow representations receive direct supervision. A conditional random field refines the masks. The authors evaluated the pipeline on challenge tasks for liver CT and cardiac MRI.
SignificanceThe study documented a single deep supervision design across CT and MRI, with experiments on both hepatic and cardiovascular structures. It also received the 2017 Medical Image Analysis–MICCAI Best Paper Award, as recorded in the first author's publication list.
DOI Full text Qi DouJing QinPheng-Ann Heng computed tomographymagnetic resonance imagingfully convolutional networkimage segmentationdeep supervision
Key2017Medical Image Analysis3,757 citations
Brain tumor segmentation with Deep Neural Networks
The paper segments glioma regions from multimodal MRI using parallel convolutional paths for local detail and wider context. A cascade can feed an earlier model's predictions into a later one. The authors compare architectures, training strategies, and processing time using the BraTS 2013 benchmark.
SignificanceThe study provided an early reference for combining local and wider context in learned brain tumor delineation. The DeepMedic paper discusses this line of dual-pathway models and uses multiscale inputs and dense training to build a volumetric lesion segmentation pipeline.
DOI arXiv Mohammad HavaeiHugo Larochelle BraTSconvolutional neural networkmagnetic resonance imagingimage segmentation
Key2017Medical Image Analysis3,993 citations
Efficient multi-scale 3D CNN with fully connected CRF for accurate brain lesion segmentation
DeepMedic uses parallel 3D convolutional pathways that see the input at different scales, providing both local detail and wider context. It predicts neighboring voxels together and refines masks with a fully connected conditional random field. The authors evaluated traumatic brain injury, tumor, and ischemic stroke segmentation.
SignificanceThe public implementation offered a common recipe for volumetric lesion segmentation across diseases. The paper documented leading performance on the BraTS 2015 and ISLES 2015 benchmarks, making it a reference for evaluating multipath CNNs on different kinds of brain lesions.
DOI arXiv Konstantinos KamnitsasBen Glocker BraTSmagnetic resonance imagingconvolutional neural networkimage segmentation
Key2017MICCAI 2017 (LNCS 10435)887 citations
Medical Image Synthesis with Context-Aware Generative Adversarial Networks
This study synthesized CT from MRI with a three-dimensional fully convolutional generator and combined adversarial, voxel, and image-gradient losses. The authors compared the estimated and reference CT images for brain and pelvic cases and reported improvements over the synthesis methods tested.
SignificanceThe paper supplied an early volumetric adversarial baseline for MR-to-CT synthesis and evaluated the same general approach in two anatomical regions. The subsequent journal article extended the investigation to additional synthesis directions and included more comparisons of cross-modality estimation.
DOI Full text Dong NieDinggang Shen generative adversarial networkcomputed tomographymagnetic resonance imaging
Key2017MICCAI 2017 (LNCS 10434)583 citations
Semi-supervised Learning for Network-Based Cardiac MR Image Segmentation
The authors trained a fully convolutional network on annotated images, then used it to segment unlabeled cardiac MR images. They alternated between refining those predictions with a conditional random field and retraining on both label sets. On short-axis images the method outperformed the supervised baseline for segmenting the left and right ventricular cavities and the myocardium.
SignificanceThe study made iterative self-training a concrete option for cardiac MR segmentation when manual contours were scarce. The later semiQCSeg study identified this early cardiac method and evaluated conditional random field refinement as a comparator for its own approach to screening predictions with a separate quality-control model.
DOI Full text Wenjia BaiDaniel Rueckert semi-supervised learningimage segmentationmagnetic resonance imagingDice coefficient
Key2018IEEE Transactions on Medical Imaging3,040 citations
Deep Learning Techniques for Automatic MRI Cardiac Multi-Structures Segmentation and Diagnosis: Is the Problem Solved?
ACDC used 150 cardiac cine MRI examinations to evaluate segmentation of both ventricular cavities and the left ventricular myocardium, as well as classification of cases into five groups. The article reported the 2017 challenge results, with the best classifier reaching 96% accuracy on 50 test cases.
SignificanceThe challenge brought cardiac contours, derived functional measurements, and diagnostic categories into one public benchmark. Subsequent research released expert scribbles on the same scans, extending the collection's use to comparisons of methods trained with sparse annotations or with full contours.
DOI Full text Olivier BernardPierre-Marc Jodoin grand challengeimage segmentationimage classificationmagnetic resonance imagingDice coefficient
Key2018arXiv1,345 citations
fastMRI: An Open Dataset and Benchmarks for Accelerated MRI
The initial fastMRI report specified single-coil and multicoil knee reconstruction tasks, with fourfold and eightfold retrospective undersampling and common scoring metrics. It compared total variation reconstruction and U-Net baselines on the same splits. The U-Net baselines obtained higher test-set structural similarity in both tasks.
SignificanceReference implementations and results made the data release usable as a shared reconstruction benchmark. The 2019 fastMRI competition used the resource to organize single-coil and multicoil tracks and added radiologist review to numerical screening, extending the initial experimental protocol.
DOI arXiv Jure ZbontarYvonne W. Lui fastMRIk-spacemagnetic resonance imagingdeep-learning reconstructionstructural similarity index
Key2018IJCAI 2018381 citations
Unsupervised Cross-Modality Domain Adaptation of ConvNets for Biomedical Image Segmentations with Adversarial Loss
A segmentation network learned to delineate four cardiac structures on labeled MR images. A plug-in module then used an adversarial objective to align features from unpaired CT with those from MRI without using CT annotations. On the held-out CT cases, overlap improved for all four structures compared with applying the original MR model directly.
SignificanceThe study made a modality change explicit by comparing direct transfer, adaptation without CT annotations, and training with target labels. The group's PnP-AdaNet extension expanded the evaluation, and later work such as ARL-GAN used that model family as a comparator on the unpaired cardiac MRI-to-CT task.
DOI arXiv Qi DouPheng-Ann Heng domain adaptationimage segmentationmagnetic resonance imagingcomputed tomography
Key2019MICCAI 2019 (LNCS 11765)1,688 citations
Uncertainty-Aware Self-ensembling Model for Semi-supervised 3D Left Atrium Segmentation
UA-MT trained a 3D left atrium segmenter with a small set of traced MR scans and a larger unlabeled set. Multiple stochastic teacher predictions supplied voxelwise uncertainty estimates, and the student was trained to match reliable targets. With 16 labeled and 64 unlabeled volumes, the method improved on the semi-supervised comparators reported in the paper.
SignificanceThe paper made the reliability of individual teacher predictions an explicit part of consistency training for volumetric segmentation and released an implementation. Subsequent co-training work using high-confidence pseudo-labels adopted the left atrium setting and reported UA-MT as a quantitative comparator at two label budgets.
DOI arXiv Lequan YuChi-Wing FuPheng-Ann Heng mean teachersemi-supervised learninguncertainty estimationmagnetic resonance imaging
Key2020Frontiers in Neuroscience166 citations
Analyzing the Quality and Challenges of Uncertainty Estimations for Brain Tumor Segmentation
Using a common brain tumor segmentation setting, the authors compare uncertainty estimation methods for calibration, error localization, and case-level quality assessment. Their BraTS experiments show that aggregate measures over the dataset can obscure how useful the uncertainty predictions are for individual images.
SignificanceThe work clarifies that a good uncertainty map may be evaluated for several different purposes, including locating mistakes and rating a whole case. A shared imaging benchmark makes the methods comparable for each intended use rather than only by their overall segmentation scores.
DOI Full text Alain JungoMauricio Reyes uncertainty estimationBraTSimage segmentationmagnetic resonance imagingprobability calibration
Key2020Medical Image Analysis570 citations
Exploring uncertainty measures in deep networks for Multiple sclerosis lesion detection and segmentation
The authors use Monte Carlo dropout to estimate uncertainty for multiple sclerosis lesions in MRI and compare scores at the voxel and lesion scales. Filtering uncertain predictions improved detection performance among retained predictions. The smallest lesions and lesion boundaries showed the most uncertainty.
SignificanceThe study treats uncertainty at the lesion level as an output that can help prioritize review. It compares several ways to derive that output, and a later medical image uncertainty survey describes it as an example of Monte Carlo dropout for lesion segmentation.
DOI arXiv Tanya NairTal Arbel uncertainty estimationmagnetic resonance imagingimage segmentationvoxeldropout
Key2020Scientific Reports2,337 citations
Federated learning in medicine: facilitating multi-institutional collaborations without sharing patient data
Using brain tumor MRI segmentation, the authors compared federated training with pooling the source data and with other collaborative training schemes. With data from ten institutions, the federated model reached 99% of centralized model quality. The study also tested performance at institutions outside the federation and examined the effect of data distribution.
SignificanceThe study supplied an early multi-institution comparison against a centralized reference model for a medical image segmentation task. The later glioblastoma federation led by Pati cited it as a predecessor when extending the approach to a substantially larger and more geographically dispersed collaboration.
DOI Full text Micah J. ShellerSpyridon Bakas federated learningBraTSimage segmentationmagnetic resonance imaging
Key2020American Journal of Roentgenology188 citations
Using Deep Learning to Accelerate Knee MRI at 3 T: Results of an Interchangeability Study
Six readers compared standard 3 T knee MRI with images reconstructed from retrospectively undersampled data. Undersampling simulated a 3.49-fold speedup over fully sampled acquisition and a 1.88-fold speedup over standard parallel acquisition. The images met the study's interchangeability criterion for internal derangement of the knee, and readers favored the accelerated images for image quality.
SignificanceThe study evaluated whether reconstructed scans could substitute for standard scans on a specified diagnostic task. Its reader-based interchangeability design supplied clinical evidence that complemented fastMRI's image similarity metrics and defined the setting in which the replacement was tested.
DOI Full text Michael P. RechtC. Lawrence Zitnick reader studymagnetic resonance imagingdeep-learning reconstruction
Key2021JAMA Neurology311 citations
Assessment of Brain Injury Using Portable, Low-Field Magnetic Resonance Imaging at the Bedside of Critically Ill Patients
In this single-center prospective study, the team performed bedside brain MRI for 50 intensive care patients using a portable 0.064 tesla scanner. They obtained several image contrasts, documented abnormalities and the numbers of diagnostic-grade examinations by sequence, and reported no adverse events during deployment or scanning.
SignificanceThe study established feasibility for acquiring brain MRI at the bedside in intensive care. Follow-up work evaluated measurements such as intracranial midline shift, and the American College of Radiology subsequently addressed the use of portable ultralow-field systems in its safety guidance.
DOI Full text Kevin N. ShethW. Taylor Kimberly low-field MRImagnetic resonance imagingtesla
Key2022DGM4MICCAI 2022 (LNCS 13609)677 citations
Brain Imaging Generation with Latent Diffusion Models
The authors trained a three-dimensional latent diffusion model on 31,740 T1-weighted brain scans from UK Biobank, conditioning generation on age, sex, and brain structure volumes. They assessed whether generated scans reflected the conditioning variables and released a collection of 100,000 synthetic images.
SignificanceThe study showed how demographic and morphological covariates could be represented in whole-volume brain MRI synthesis and made generated volumes available for reuse. The corresponding model is distributed through the MONAI model zoo, giving researchers a reference implementation for controlled volumetric generation.
DOI arXiv Walter H. L. PinayaM. Jorge Cardoso diffusion modelmagnetic resonance imagingUK Biobankautoencodersynthetic data
Key2022Nature Communications538 citations
Federated learning enables big data for rare cancer boundary detection
The glioblastoma MRI study included 6,314 cases from 71 sites on six continents. Sites shared model updates during federated training, with local cases reserved for validation and 590 cases from six sites reserved for external testing. The resulting model improved delineation of the surgically targetable region and the full tumor extent relative to a model trained on public data.
SignificanceThe study extended earlier federated brain tumor segmentation to a multi-continent collaboration and made the consensus model available for further analyses. Its scale and documented distribution of participating sites supplied an empirical reference for work on rare imaging conditions where single institutions have few cases.
DOI Full text Sarthak PatiSpyridon Bakas federated learningmagnetic resonance imagingimage segmentation
Key2022ICLR 2022865 citations
Solving Inverse Problems in Medical Imaging with Score-Based Generative Models
The researchers learned a generative score prior from medical images and introduced the measurements and their forward operator during sampling at test time. Tests included CT and MRI inverse problems. The study reported comparable or improved reconstruction in several tasks and stronger generalization to changed measurement processes.
SignificanceThe study used a common framework to test score priors across tomographic and MR measurement models. By varying the operator used at inference, it provided a direct evaluation of whether a learned prior could support multiple reconstruction tasks without acquisition-specific paired training.
arXiv Yang SongStefano Ermon inverse problemdiffusion modelcomputed tomographymagnetic resonance imagingdata consistency
Key2022BrainLes at MICCAI 2021 (LNCS 12962)3,708 citations
Swin UNETR: Swin Transformers for Semantic Segmentation of Brain Tumors in MRI Images
Swin UNETR applies hierarchical shifted-window attention to patches from multimodal brain MRI, then passes the multiresolution representations to a convolutional decoder through skip connections. The authors evaluate segmentation of glioma subregions using the BraTS 2021 benchmark under the challenge's testing setup.
SignificanceThe architecture made hierarchical Swin encoding usable for three-dimensional tumor segmentation. A related study used this design in self-supervised pretraining on unlabeled CT, and MONAI provides a reusable implementation for training and evaluating volumetric segmentation models.
DOI arXiv Ali HatamizadehDaguang Xu Swin TransformerU-NetBraTSmagnetic resonance imaging
Key2023Scientific Reports536 citations
Denoising diffusion probabilistic models for 3D medical image generation
The authors trained denoising diffusion models to synthesize three-dimensional CT and MR images. Two radiologists assessed image appearance, anatomy, and consistency across slices. An additional experiment used synthetic images for self-supervised pretraining and reported improved Dice on breast segmentation with scarce training data.
SignificanceThe study gave a cross-modality reference for combining radiologist assessment of synthetic volumes with a downstream experiment. Later MedSyn work included this medical diffusion approach in comparisons of chest CT synthesis, examining anatomy and image quality under the new task.
DOI arXiv Full text Firas KhaderDaniel Truhn diffusion modelmagnetic resonance imagingcomputed tomographyself-supervised learningsynthetic data
Key2023IEEE Transactions on Medical Imaging724 citations
Unsupervised Medical Image Translation With Adversarial Diffusion Models
SynDiff combined cycle-based translation with adversarial diffusion to learn from unpaired medical images. The source image conditioned the synthesis and an adversarial diffusion component allowed fewer reverse steps. The authors reported improvements over tested baselines for MRI contrast translation and for translation between MRI and CT.
SignificanceSynDiff supplied a reproducible example of combining diffusion sampling with adversarial learning when aligned source and target scans are unavailable. Its public implementation and comparisons across modalities support follow-up evaluations of image fidelity and sampling cost under the same translation settings.
DOI arXiv Muzaffer ÖzbeyTolga Çukur diffusion modelgenerative adversarial networkmagnetic resonance imagingcomputed tomographycycle consistency
Key2024ECCV 2024 (LNCS 15118)12 citations
Task-Driven Uncertainty Quantification in Inverse Problems via Conformal Prediction
The authors use conformal calibration to quantify uncertainty that undersampling and reconstruction contribute to a downstream task. In accelerated MRI experiments they construct intervals for the task score that would be obtained from the fully sampled image and simulate stopping acquisition according to interval width.
SignificanceThis study connects reconstruction uncertainty directly to a downstream scalar output, giving investigators a target different from pixel-level error. The accelerated MRI experiments show how the usefulness of additional measurements can be evaluated in terms of an intended imaging task.
DOI arXiv Full text Jeffrey WenPhilip Schniter uncertainty estimationmagnetic resonance imaginginverse problemdeep-learning reconstructionconformal prediction
Key2025Radiology65 citations
American College of Radiology Manual on MR Safety: 2024 Update and Revisions
Members of the American College of Radiology committee described the structure and rationale of the 2024 safety manual. They reviewed facility zones, staff roles, patient and equipment screening, and emergency procedures, as well as evidence gaps for remote operation and scanners outside conventional field strengths.
SignificanceThe article documents the technical and clinical reasoning behind the American College of Radiology's consolidated MR safety recommendations. The manual covers institutional controls for risks from static fields, switched gradients, and radio-frequency exposure and addresses portable and ultrahigh-field systems.
DOI Ivan PedrosaRobert E. Watson magnetic resonance imagingultra-high-field MRIlow-field MRItesla
Notable2003Investigative Radiology247 citations
Magnetic Resonance Imaging at 3.0 Tesla: Challenges and Advantages in Clinical Neurological Imaging
The Calgary group summarized 40 months of clinical neuroradiology at 3 tesla and presented patient images to illustrate potential benefits relative to 1.5 tesla. They described higher signal-to-noise and changes in contrast alongside practical issues involving radio-frequency power, coil design, and implant compatibility.
SignificanceThis report documented early clinical operation at 3 tesla and made the practical demands of higher-field imaging explicit alongside its benefits. Later guidance from the American College of Radiology continues to address risks by field strength and device conditions.
DOI Richard Frayne magnetic resonance imagingteslasignal-to-noise ratioartifact
Notable2017MICCAI 2017 (LNCS 10434)287 citations
Automatic 3D Cardiovascular MR Segmentation with Densely-Connected Volumetric ConvNets
DenseVoxNet uses densely connected volumetric convolutional blocks so later layers can reuse earlier voxel features. The authors apply the resulting compact network to cardiovascular MRI and compare the segmentation of the myocardium and blood pool with prior methods using the HVSMR 2016 benchmark.
SignificanceThis work illustrates the transfer of DenseNet-style feature reuse from recognition to three-dimensional cardiac delineation. Its comparisons put model size alongside blood-pool and myocardium segmentation performance on the same dataset, a practical issue when labeled volumes are scarce.
DOI arXiv Lequan YuPheng-Ann Heng fully convolutional networkmagnetic resonance imagingvoxelimage segmentationdense connectivity
Notable2017AAAI 2017380 citations
Volumetric ConvNets with Mixed Residual Connections for Automated Prostate Segmentation from 3D MR Images
A 3D convolutional network predicts a prostate mask directly from a volume of MR images. It combines short residual paths within blocks with longer ones between levels, improving the propagation of location information and gradients. The authors report first place on the PROMISE12 benchmark at the time.
SignificanceThe work documents early use of residual architecture on an open prostate segmentation benchmark. Its comparisons within that task illustrate how short and long connections can be combined in a volumetric model trained with limited annotated scans.
DOI Full text Lequan YuPheng-Ann Heng magnetic resonance imagingimage segmentationskip connection
Notable2020FDA 510(k) Premarket Notification K193282
SIGNA Premier
On April 10, 2020, the FDA found the SIGNA Premier MRI scanner substantially equivalent with the addition of its AIR Recon DL software feature. The submission described phantom tests and blinded radiologist readings that assessed signal-to-noise ratio, sharpness, lesion conspicuity, and image quality at shorter acquisition times.
SignificanceThe clearance documents scanner integration of learned reconstruction in commercial MRI. A subsequent outpatient implementation study included AIR Recon DL among the reconstruction products deployed and measured examination and turnaround times before and after implementation in routine practice.
Full text deep-learning reconstructionFDA 510(k) clearancemagnetic resonance imaging
Notable2025Computerized Medical Imaging and Graphics10 citations
3D cardiac shape analysis with variational point cloud autoencoders for myocardial infarction prediction and virtual heart synthesis
A variational point-cloud autoencoder learned three-dimensional cardiac shape variation using data from more than 10,000 subjects. In the study cohort, regression on the latent variables achieved higher AUROC than clinical biomarker baselines, including ejection fraction, for detecting prevalent and predicting incident myocardial infarction. The authors also used generated hearts in electrophysiology simulations.
SignificanceThe study demonstrated a concrete use of medical shape generation in building populations of virtual hearts for computational experiments. By running electrophysiology simulations on generated geometries, it evaluated a downstream use beyond geometric similarity to the training point clouds.
DOI Full text point cloudautoencodermagnetic resonance imaging
Notable2025Medical Image Analysis39 citations
Brain Latent Progression: Individual-based spatiotemporal disease progression on 3D Brain MRIs via latent diffusion
BrLP combines latent diffusion with estimates of changes in structure volumes to forecast an individual’s future 3D brain MRI from available observations. Its external test used 2,257 T1-weighted scans from 962 NACC participants, comparing generated images with actual follow-up scans.
SignificanceObserved scans provided a reference for image and structure-volume prediction errors. The authors separately estimated uncertainty at the scan and voxel levels, and found that the forecasts tended toward changes typical of healthy aging in this study of aging and Alzheimer’s disease.
DOI arXiv Full text magnetic resonance imagingdiffusion modelexternal validationworld model
Notable2026ECCV 2026 (LNCS 17076)17 citations
CLARITY: Medical World Model for Guiding Treatment Decisions by Simulating Context-Aware Disease Trajectories
CLARITY predicts changes in imaging-derived features using elapsed time, clinical information, and treatments, then scores simulated trajectories with a survival model. Retrospective endpoints included survival prediction, agreement of proposed and recorded regimens, and a blinded expert comparison of recommendations for 40 held-out cases.
SignificanceThe work makes treatment an input to imaging state transitions. Regimen matching and expert ratings measure agreement and plausibility, respectively. The effect of an alternative treatment on an individual would require evidence beyond these retrospective comparisons.
DOI arXiv magnetic resonance imagingexternal validationworld modelrolloutcounterfactual prediction