Physics

phase encodingPE

相位编码

In MRI, phase encoding uses a temporary magnetic field gradient to create position-dependent phase shifts. Varying the time integral of the gradient allows the scanner to collect distinct spatial measurements.

A brief pulse from a gradient coil changes the magnetic field along one axis. Spins at different positions precess at different rates during that pulse. When the pulse ends, the frequency differences it induced disappear, but the accumulated phase differences remain. The area under the gradient waveform determines the coordinate on that axis of k-space.

A conventional two-dimensional acquisition sets one phase-encoding value before recording a line of data along the frequency-encoding axis. Several lines together specify the structure along the phase-encoding direction. Their spacing sets the field of view along that axis. If the lines are too far apart, anatomy outside the reconstructed field may wrap into it through aliasing.

Sources
  1. Larson PEZ. Principles of MRI. Spatial Encoding. larsonlab.github.io/MRI-education-resources/Spatial%20Encoding.h
  2. Plewes DB, Kucharczyk W. Physics of MRI: A Primer. J Magn Reson Imaging, 2012. doi.org/10.1002/jmri.23642

Key works · 5

Landmark1975Journal of Magnetic Resonance881 citations

NMR Fourier zeugmatography

Anil Kumar, Dieter Welti, Richard R. Ernst

The authors applied sequences of pulsed magnetic field gradients during a series of free induction decays to encode the spatial frequency components of spin density. A multidimensional Fourier transform reconstructed the image. The paper set out how the gradient pulses and measurement timing determined which components were acquired.

SignificanceDirect Fourier sampling offered a framework for combining frequency encoding with repeated phase encoding. The subsequent spin-warp method adapted Fourier encoding for routine image acquisition, establishing an approach that remains central to conventional clinical magnetic resonance imaging.

Landmark1980Physics in Medicine and Biology952 citations

Spin warp NMR imaging and applications to human whole-body imaging

W A Edelstein, J M S Hutchison … T Redpath

The Aberdeen group described spin-warp imaging, in which a gradient encodes phase with a different amplitude on successive excitations and a readout gradient encodes frequency. They presented examples of human imaging with the sequence using a 0.04 tesla magnet large enough to accommodate the body.

SignificanceSpin-warp imaging made slice selection and Fourier encoding practical in a sequence for human scanning. Aberdeen subsequently used its system to scan a patient, and the method's line-by-line acquisition of spatial frequency data became a standard approach in clinical MRI.

Landmark1986Magnetic Resonance in Medicine2,345 citations

RARE imaging: A fast imaging method for clinical MR

Jürgen Hennig, Arno Nauerth, Hartmut Friedburg

The team assigned a different phase-encoding step to each of several spin echoes following excitation, collecting enough data for a 256 by 256 image in 2 to 40 seconds. They examined artifacts caused by changing T2 weighting across the echo train and how phase-encoding order could reduce them.

SignificanceAcquiring multiple k-space lines from a train of refocused echoes became the basis of clinical fast or turbo spin-echo imaging. Later implementations retained this approach to accelerating T2-weighted acquisitions while addressing the blurring and radio-frequency demands of long echo trains.

Landmark2007Magnetic Resonance in Medicine7,800 citations

Sparse MRI: The application of compressed sensing for rapid MR imaging

Michael Lustig, David Donoho, John M. Pauly

The authors undersampled phase-encoding lines with a variable-density pseudorandom pattern and reconstructed images by penalizing transform coefficients subject to consistency with the measured data. Examples in multislice fast spin-echo brain images and three-dimensional contrast-enhanced angiography demonstrated how the method could accelerate acquisition.

SignificanceThe paper converted compressed sensing into an acquisition and reconstruction procedure that could be implemented on an MR scanner. Later studies combined sparse recovery and parallel imaging and evaluated the resulting shorter acquisitions in settings such as contrast-enhanced pediatric abdominal MRI.

Key1997Magnetic Resonance in Medicine2,458 citations

Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays

Daniel K. Sodickson, Warren J. Manning

SMASH formed spatial harmonics by linearly combining the sensitivities of array elements. This enabled the reconstruction of skipped phase-encoding lines in k-space before Fourier transformation. Using commercial phased arrays on two MRI systems, the authors demonstrated a twofold reduction in acquisition time.

SignificanceSMASH established a way to recover phase encoding in k-space from the spatial responses of a coil array. The later VD-AUTO-SMASH method used extra acquired data to calibrate the synthesis. The GRAPPA paper identifies that self-calibrating variant as one of its direct predecessors.