signal-to-noise ratioSNR
信噪比
The ratio of signal strength to noise, a measure of how clean an image is. Low SNR buries detail in grain; raising it costs more photons, a stronger magnet or more scan time.
The simplest definition is the mean signal in a uniform region divided by its standard deviation, . In photon-counting imaging , so doubling the dose improves SNR by only about 41%.
In 1948 the American physicist Albert Rose, studying the limits of vision in dim light, concluded that an object needs an SNR of about 5 before an observer can reliably detect it. The Rose criterion is still the rule of thumb for estimating what an imaging system can show.
In MRI, SNR scales roughly with field strength and with voxel volume, and with the square root of acquisition time. Going from 1.5 T to 3 T roughly doubles it, a gain that can be spent on thinner slices or faster scans. Because SNR has to be paid for in dose or time, denoising and deep-learning reconstruction have real clinical value.
- Rose A. The sensitivity performance of the human eye on an absolute scale. J Opt Soc Am. 1948;38(2):196–208. doi.org/10.1364/JOSA.38.000196
Key works · 6
Landmark1990Magnetic Resonance in Medicine2,653 citations
The NMR phased array
The authors reduced coupling among receiving coils by overlapping neighboring coils and using low-input-impedance preamplifiers. They derived a rule for combining coil data to maximize signal-to-noise ratio. Two four-element arrays yielded twofold and threefold gains at the depth of the spine compared with one large coil under matched imaging conditions.
SignificanceThe receive array provided broad coverage while preserving separate measurements from local coils. Both SMASH and SENSE cited the array work and used differences among coil sensitivities as spatial encoding, turning those separate measurements into a means of accelerating acquisition.
DOI Peter B. RoemerWilliam A. EdelsteinO. M. Mueller magnetic resonance imagingsignal-to-noise ratioparallel imaging
Key1948Journal of the Optical Society of America1,056 citations
The Sensitivity Performance of the Human Eye on an Absolute Scale
Rose used a detector limited by random photon fluctuations as a benchmark for human visual sensitivity. A television pickup experiment related target visibility to luminance, contrast, and angular size. Under the experimental model he estimated a threshold signal-to-noise ratio of about five.
SignificanceThe result became the Rose criterion used in image quality analysis. Medical physics texts use it as an approximate detectability benchmark for targets in noisy images, where visibility also depends on target size, background, and the viewing task.
DOI Albert Rose noisesignal-to-noise ratiocontrast-to-noise ratiocontrast
Key1997Magnetic Resonance in Medicine2,458 citations
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
SMASH formed spatial harmonics by linearly combining the sensitivities of array elements. This enabled the reconstruction of skipped phase-encoding lines in k-space before Fourier transformation. Using commercial phased arrays on two MRI systems, the authors demonstrated a twofold reduction in acquisition time.
SignificanceSMASH established a way to recover phase encoding in k-space from the spatial responses of a coil array. The later VD-AUTO-SMASH method used extra acquired data to calibrate the synthesis. The GRAPPA paper identifies that self-calibrating variant as one of its direct predecessors.
DOI Daniel K. SodicksonWarren J. Manning parallel imagingk-spacesignal-to-noise ratiophase encoding
Key2001Magnetic Resonance in Medicine980 citations
7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images
The authors compared human head imaging at 7 and 4 tesla using measurements and electromagnetic modeling. At 7 tesla, average brain signal-to-noise was at least 1.6 times the value at 4 tesla, while the radio-frequency field was less uniform and excitation at the center of the head required more power.
SignificanceThe controlled comparison quantified both the signal gain and the radio-frequency engineering demands of ultrahigh field, providing a reference for subsequent coil and imaging work. The US Food and Drug Administration cleared the first clinical 7 tesla device in 2017.
DOI J. Thomas VaughanKâmil Uğurbil ultra-high-field MRIteslasignal-to-noise ratioRF pulse
Key2018Journal of Nuclear Medicine827 citations
Total-Body PET: Maximizing Sensitivity to Create New Opportunities for Clinical Research and Patient Care
The authors reviewed geometric and timing improvements that could increase PET sensitivity. They estimated that extending axial coverage to the whole body could increase effective sensitivity about 40-fold for whole-body imaging and discussed the implications for scan duration, administered activity, and dynamic studies.
SignificanceThe article provided a quantitative rationale for a scanner with an extended axial field and distinguished the gains for whole-body imaging from those for a single organ. The EXPLORER system subsequently tested several of those opportunities in human imaging.
DOI Full text Simon R. CherryRamsey D. Badawi total-body PETsignal-to-noise ratiotime-of-flight PET
Notable2003Investigative Radiology247 citations
Magnetic Resonance Imaging at 3.0 Tesla: Challenges and Advantages in Clinical Neurological Imaging
The Calgary group summarized 40 months of clinical neuroradiology at 3 tesla and presented patient images to illustrate potential benefits relative to 1.5 tesla. They described higher signal-to-noise and changes in contrast alongside practical issues involving radio-frequency power, coil design, and implant compatibility.
SignificanceThis report documented early clinical operation at 3 tesla and made the practical demands of higher-field imaging explicit alongside its benefits. Later guidance from the American College of Radiology continues to address risks by field strength and device conditions.
DOI Richard Frayne magnetic resonance imagingteslasignal-to-noise ratioartifact