noise
噪声
Random fluctuation added to the true signal, which makes uniform tissue look grainy. In X-ray and nuclear imaging it comes mainly from counting a finite number of photons, so lower dose means coarser grain.
Photons reach the detector at random and obey Poisson statistics: if are counted on average, the standard deviation is and the relative noise . Halving the noise takes four times the photons, and so four times the dose; halving the dose raises the noise by only about 41%. That square root sits at the center of every low-dose CT and ALARA discussion.
MRI noise comes mostly from the thermal motion of charges in the patient's body and the receiver coils. The grain in an ultrasound image is mostly not noise at all but speckle, an interference pattern of scattered echoes that stays put while the probe is still.
Noise has texture as well as size. Iterative and deep-learning reconstruction remove much of it, but pushed too far they give the image a waxy look and can smooth away small structures along with the grain.
Key works · 4
Landmark1949Proceedings of the IRE9,337 citations
Communication in the Presence of Noise
Shannon represented messages and transmitted signals as points in function spaces and expressed a band-limited waveform in terms of uniformly spaced samples. The paper gave a construction for recovering the waveform from sufficiently close samples and analyzed achievable transmission rates in the presence of noise.
SignificanceThe sampling relationship provides a theoretical basis for the spatial spacing of digital image samples. Applying the same reasoning to spatial frequencies explains why detail beyond the range represented by the sampling grid can appear as spurious lower-frequency structure.
DOI Claude E. Shannon samplingNyquist–Shannon sampling theoremaliasingnoise
Key1948Journal of the Optical Society of America1,056 citations
The Sensitivity Performance of the Human Eye on an Absolute Scale
Rose used a detector limited by random photon fluctuations as a benchmark for human visual sensitivity. A television pickup experiment related target visibility to luminance, contrast, and angular size. Under the experimental model he estimated a threshold signal-to-noise ratio of about five.
SignificanceThe result became the Rose criterion used in image quality analysis. Medical physics texts use it as an approximate detectability benchmark for targets in noisy images, where visibility also depends on target size, background, and the viewing task.
DOI Albert Rose noisesignal-to-noise ratiocontrast-to-noise ratiocontrast
Key2007Medical Physics1,028 citations
A three-dimensional statistical approach to improved image quality for multislice helical CT
The method used a three-dimensional forward model of multislice helical acquisition, statistical weighting of measurements, and a prior on the image. Phantom tests demonstrated improved resolution and lower noise alongside reduced helical cone-beam artifacts. Reconstructions of patient scans illustrated clinical image appearance.
SignificanceThe work demonstrated model-based iterative reconstruction on real multislice helical CT data. Later evaluations of commercial model-based reconstruction cite this study when examining how spatial resolution and image noise vary with exposure and reconstruction settings.
DOI Full text Jean-Baptiste ThibaultJiang Hsieh iterative reconstructionhelical CTmultidetector CTnoise
Key2016Radiology223 citations
Abdominal Imaging with Contrast-enhanced Photon-counting CT: First Human Experience
Fifteen asymptomatic volunteers underwent paired, dose-matched contrast-enhanced abdominal CT scans with a photon-counting prototype and an energy-integrating detector. Readers gave the two methods similar scores for image quality, noise, and artifacts. Iodine maps generated from the photon-counting data improved the contrast-to-noise ratio for enhanced kidney tissue in the reported comparison.
SignificanceThis paired study established the feasibility of conventional contrast-enhanced abdominal imaging with a photon-counting prototype while demonstrating spectral iodine mapping from the same acquisition. The group subsequently extended abdominal material decomposition to distinguish two contrast agents in an in vivo animal study.
DOI Full text Amir PourmortezaDavid A. Bluemke photon-counting CTcontrast agentnoisematerial decomposition