denoising
去噪
Removing random noise from an image while keeping its real structure. In medical imaging it decides how far dose or scan time can be cut, since both trade directly against noise.
Quantum noise in CT scales with one over the square root of dose: halve the dose and noise rises by about 41%. The difficulty is that noise and fine detail both live at high spatial frequencies. A Gaussian blur treats them alike and softens edges along with grain. Later methods smooth selectively. Pietro Perona and Jitendra Malik's anisotropic diffusion (1990) smooths along edges but not across them; non-local means (Buades, Coll and Morel, 2005) averages similar patches from anywhere in the image; BM3D (2007) stacks similar patches into 3D groups and filters them jointly, and was the benchmark for years.
Deep learning turns denoising into learning a mapping from paired low-dose and routine-dose images, as RED-CNN did for low-dose CT in 2017. Noise2Noise (2018) showed that a network can be trained on pairs of independent noisy images, with no clean target at all.
Peak signal-to-noise ratio alone is an inadequate measure. Over-smoothed images look plastic, and small low-contrast lesions can be removed along with the noise; what counts is whether a reader still finds the lesion.
- Perona P, Malik J. Scale-space and edge detection using anisotropic diffusion. IEEE Trans Pattern Anal Mach Intell. 1990;12(7):629–639. doi.org/10.1109/34.56205
- Buades A, Coll B, Morel JM. A non-local algorithm for image denoising. CVPR 2005. doi.org/10.1109/CVPR.2005.38
- Dabov K, Foi A, Katkovnik V, Egiazarian K. Image denoising by sparse 3-D transform-domain collaborative filtering. IEEE Trans Image Process. 2007;16(8):2080–2095. doi.org/10.1109/TIP.2007.901238
- Chen H, et al. Low-dose CT with a residual encoder-decoder convolutional neural network. IEEE Trans Med Imaging. 2017;36(12):2524–2535. doi.org/10.1109/TMI.2017.2715284
- Lehtinen J, et al. Noise2Noise: learning image restoration without clean data. ICML 2018. arxiv.org/abs/1803.04189
Key works · 5
Landmark2017IEEE Transactions on Medical Imaging2,163 citations
Low-Dose CT With a Residual Encoder-Decoder Convolutional Neural Network
RED-CNN trained a residual convolutional encoder-decoder on image patches to denoise reconstructed low-dose CT. Its shortcuts linked encoder and decoder layers. Tests using simulated and clinical images compared noise suppression, preservation of anatomical structure, and lesion visibility with those of other image-domain methods.
SignificanceRED-CNN became a reference for denoising low-dose CT images after reconstruction, which makes the method testable without access to vendor-specific projections. Zeng and colleagues used it to study how differences in dose, reconstruction kernel, and slice thickness between training and testing affect denoising.
DOI arXiv Full text Hu ChenYi ZhangGe Wang low-dose CTdenoisingencoder–decoderskip connection
Landmark2020NeurIPS 202021,081 citations
Denoising Diffusion Probabilistic Models
DDPM gradually corrupted training images with a fixed noise process and trained a network to predict the added noise at different time steps. Sampling reversed this process from random noise. The paper related its training objective to denoising score matching and assessed unconditional generation on image benchmarks.
SignificanceDDPM provided the training and sampling formulation adopted in many later diffusion generators. The medical diffusion study by Khader and the point-cloud model by Luo and Hu applied variants of the same denoising approach to volumes and unordered coordinate sets.
Key2017Medical Physics924 citations
A deep convolutional neural network using directional wavelets for low‐dose X‐ray CT reconstruction
The researchers applied a residual convolutional network to directional wavelet coefficients of reconstructed low-dose CT. The transform exposed oriented noise patterns and dependencies across bands. The method placed second in the 2016 Low Dose CT Grand Challenge, whose evaluation included readers marking liver metastases.
SignificanceThe challenge gave this early denoising method a common test set and a reader-based endpoint. The approach also established a practical example of performing learned denoising in a transform basis, a distinction retained in later reviews of low-dose CT methods.
DOI arXiv Eunhee KangJong Chul Ye low-dose CTdenoisingartifact
Key2017IEEE Transactions on Medical Imaging1,150 citations
Generative Adversarial Networks for Noise Reduction in Low-Dose CT
The authors trained a denoiser using cardiac CT images acquired at 20% of the routine dose. Voxel loss alone yielded the highest peak signal-to-noise ratio, while adversarial training better reproduced routine-dose image statistics. Denoising improved low-density calcium measurements in phantoms and enabled calcium scoring on noisy patient scans.
SignificanceThe experiment distinguished agreement with reference pixels, similarity of noise appearance, and usability for calcium scoring on the same set of scans. Reviews of low-dose CT restoration include it among the early uses of adversarial objectives in image-domain denoising.
DOI Jelmer M. WolterinkIvana Išgum generative adversarial networklow-dose CTdenoising
Key2023Medical Image Analysis1,207 citations
Diffusion models in medical imaging: A comprehensive survey
This survey introduced diffusion training and sampling, then organized early medical imaging studies by task. It covered two- and three-dimensional generation, translation, reconstruction, segmentation, and anomaly detection. Its task tables documented datasets, conditioning inputs, and evaluation methods, alongside practical issues such as computational cost.
SignificanceThe review became a widely cited entry point to early medical diffusion research. Its cross-task organization makes it possible to trace which assumptions and evaluation designs were used in the underlying studies, helping distinguish image synthesis questions from reconstruction with measured data.
DOI arXiv Amirhossein KazerouniDorit Merhof diffusion modelinverse problemdenoising