Modalities

contrast agent

造影剂

A substance introduced into the body to make otherwise invisible structures show: iodine or barium raise X-ray attenuation, gadolinium-based contrast agent shortens MRI relaxation times, and microbubbles brighten ultrasound echoes. A contrast-enhanced scan is one done with an injected agent.

X-ray agents rely on high atomic number. Iodine (Z = 53) has its K-absorption edge at 33.2 keV and barium (Z = 56) at 37.4 keV, both inside the diagnostic X-ray range, so their photoelectric absorption far exceeds that of soft tissue. Barium is swallowed or given as an enema to outline the gut; iodine is injected to show vessels and well-perfused lesions. MRI's gadolinium-based contrast agent works differently: it shortens the T1 of nearby water protons, making them brighter.

Egas Moniz's first cerebral angiograms in 1927 depended on injected contrast. Thorotrast, introduced in 1929, was later found to cause cancer and abandoned. From the late 1970s non-ionic iodinated agents with lower osmolality and fewer side effects took over.

Timing matters: arterial, portal-venous and delayed phases reveal how a lesion is supplied with blood. Agents carry risks too, from allergy-like reactions to concerns in patients with poor kidney function.

Sources
  1. Artico M, et al. Egas Moniz: 90 years (1927–2017) from cerebral angiography. Front Neuroanat. 2017;11:81. www.ncbi.nlm.nih.gov/pmc/articles/PMC5610728/
  2. Wikipedia. Radiocontrast agent. en.wikipedia.org/wiki/Radiocontrast_agent

Key works · 7

Landmark1953Acta Radiologica3,839 citations

Catheter Replacement of the Needle in Percutaneous Arteriography: A New Technique

Sven Ivar Seldinger

Seldinger described a method of placing a flexible catheter through the arterial entry site made by a puncture needle. A guidewire maintained access during the exchange. The report illustrated how the catheter could then be positioned to deliver contrast at a selected point in the circulation.

SignificanceMaintaining access with a guidewire made selective arteriography possible through a percutaneous puncture. The named Seldinger technique became a standard method of vascular access for diagnostic angiography and for a wide range of interventions performed through a catheter.

Landmark1968Investigative Radiology1,093 citations

Echocardiography of the Aortic Root

Raymond Gramiak, Pravin M. Shah

To identify the source of two moving echoes on an echocardiogram, the authors injected saline above the aortic valve while recording continuously. A transient cloud of echoes appeared between the two traces of the aortic root. Blood entering from the left ventricle during systole interrupted the cloud as the valve opened.

SignificanceThe enhanced echoes let the team use flowing blood to verify the anatomical origin of the traces. The group published further contrast experiments in 1969. A University of Rochester retrospective documents the subsequent research that identified bubbles as the source of enhanced echoes.

Key1966Circulation582 citations

Selective Cine Coronary Arteriography: Correlation with Clinical Findings in 1,000 Patients

William L. Proudfit, Earl K. Shirey … Jr.

The authors reviewed 1,000 patients with adequate selective cine coronary arteriograms. A physician assessed the clinical records without seeing the angiograms. Significant obstruction appeared in 95% of those diagnosed with angina without rest pain. Agreement with the angiographic findings was lower for less characteristic syndromes.

SignificanceThis series showed what selective cine arteriography could add to clinical assessment by documenting coronary obstruction where symptoms gave an uncertain indication. The same group used the clinical and angiographic comparison in subsequent work to study how presenting features related to the extent of obstructive lesions.

Key1980AJR American Journal of Roentgenology156 citations

Computerized Fluoroscopy: Digital Subtraction for Intravenous Angiocardiography and Arteriography

Andrew B. Crummy, Charles M. Strother … Robert A. Kruger

The system used digital time and energy subtraction to enhance the iodine signal from image-intensified fluoroscopy. The authors presented clinical examples of time subtraction after intravenous contrast injection, showing the heart and carotid, abdominal, and peripheral arteries. The examples included stenoses, occlusions, and aneurysms.

SignificanceThe images extended the group's earlier work on cardiac motion to clinical examples of vascular disease in several arterial territories. The team subsequently reported arterial imaging with the same intravenous subtraction approach, documenting where computerized fluoroscopy could be used for vascular assessment.

Key1984The Lancet259 citations

Intravenous chelated gadolinium as a contrast agent in NMR imaging of cerebral tumours

D. H. Carr, J. Brown … I. R. Young

The authors imaged 12 patients with brain tumors before and after intravenous administration of the gadolinium chelate Gd-DTPA. All tumors enhanced after injection. Ring enhancement was the most frequent pattern, and enhancement was visible with both inversion-recovery and spin-echo sequences.

SignificanceThis patient study provided early evidence that a gadolinium chelate could improve visualization of brain tumors. Contrast based on relaxation changes after administration of paramagnetic agents subsequently became an established option for delineating lesions of the central nervous system.

Key1990Radiology1,612 citations

Adverse reactions to ionic and nonionic contrast media. A report from the Japanese Committee on the Safety of Contrast Media.

H. Katayama, K. Yamaguchi … K. Matsuura

This prospective nationwide comparison in Japan recorded adverse reactions in 337,647 contrast examinations. Reactions were less frequent with low-osmolar nonionic agents than with high-osmolar ionic agents. Severe reactions occurred in 0.04% of examinations using nonionic agents and in 0.22% of those using ionic agents.

SignificanceThe size of the study allowed a comparison of uncommon severe reactions across contrast formulations and supported the move toward low-osmolar agents. The American College of Radiology cites the study in its contrast media manual when discussing acute reactions.

Key2016Radiology223 citations

Abdominal Imaging with Contrast-enhanced Photon-counting CT: First Human Experience

Amir Pourmorteza, Rolf Symons … Gregory Henderson

Fifteen asymptomatic volunteers underwent paired, dose-matched contrast-enhanced abdominal CT scans with a photon-counting prototype and an energy-integrating detector. Readers gave the two methods similar scores for image quality, noise, and artifacts. Iodine maps generated from the photon-counting data improved the contrast-to-noise ratio for enhanced kidney tissue in the reported comparison.

SignificanceThis paired study established the feasibility of conventional contrast-enhanced abdominal imaging with a photon-counting prototype while demonstrating spectral iodine mapping from the same acquisition. The group subsequently extended abdominal material decomposition to distinguish two contrast agents in an in vivo animal study.