Modalities · 1942

ultrasound imagingUS

超声成像

Imaging with sound pitched far above human hearing: a probe sends short pulses and times the returning echoes to find depth. Cheap, free of ionizing radiation and real-time, it is one of the most widely used imaging tests in the world, though highly operator-dependent.

Diagnostic ultrasound runs at about 2–15 MHz. The transducer fires a short pulse and then receives the echoes; by the pulse–echo principle principle, with sound traveling at about 1540 m/s in soft tissue, every 13 μs of echo delay means another centimeter of depth. The larger the acoustic impedance mismatch at a boundary, the stronger the reflection. Bone and gas send back nearly everything, which is why ultrasound cannot image through lung or bone. Higher frequencies resolve finer detail but are absorbed faster, so they penetrate less deeply.

In 1942 the Austrian neurologist Karl Dussik tried to image the brain's ventricles with transmitted ultrasound; his pictures later proved to be mostly skull artifacts. In 1958 Ian Donald, John MacVicar and Tom Brown described pulse–echo scans of abdominal masses in The Lancet, and obstetric ultrasound grew from that work.

With no ionizing radiation, a live view of moving organs and machines now small enough for a pocket, ultrasound's main limitation is the person holding the probe: image quality depends heavily on skill and experience.

Sources
  1. Donald I, MacVicar J, Brown TG. Investigation of abdominal masses by pulsed ultrasound. Lancet. 1958;271(7032):1188–1195. doi.org/10.1016/s0140-6736(58)91905-6
  2. Radiopaedia. Karl Dussik. radiopaedia.org/articles/karl-dussik

Key works · 19

Landmark1952Science216 citations

Application of Echo-Ranging Techniques to the Determination of Structure of Biological Tissues

John J. Wild, John M. Reid

The investigators used pulsed ultrasound to record echoes from biological tissues and moved the probe to assemble two-dimensional records from successive positions. They compared echo patterns from normal tissue and masses, showing that the reflections could reveal differences in soft tissue structure.

SignificanceThe paper was an early demonstration of using pulse-echo ranging to display soft tissue in two dimensions. The same investigators subsequently extended the approach to imaging lesions in the intact human breast, an early application of diagnostic ultrasound to a specific organ.

Landmark1952Journal of Laboratory and Clinical Medicine229 citations

Ultrasonic visualization of soft tissue structures of the body

Douglass H. Howry, W. Roderic Bliss

The investigators recorded echoes from soft tissue interfaces and assembled the returns according to the probe position and direction to form cross-sectional pictures. They presented ultrasonic sections alongside the corresponding objects to show which boundaries and internal structures the method could depict.

SignificanceThe work established an early approach for assembling echoes from different directions into an anatomical cross section. Howry's group subsequently developed compound scanning arrangements that reduced the need to immerse the subject, making cross-sectional imaging more practical in patients.

Landmark1958The Lancet708 citations

Investigation of abdominal masses by pulsed ultrasound

Ian Donald, J. MacVicar, T. G. Brown

The Glasgow team investigated abdominal masses using pulsed ultrasound and combined echoes obtained from different directions into sectional displays. Clinical cases illustrated differences between the return patterns of fluid-filled cysts and masses containing solid tissue, and the report also included pregnancy-related observations.

SignificanceThe report provided early clinical evidence for pulse-echo ultrasound in obstetrics and gynecology. The contact compound scanner and the diagnostic cases helped establish a program of abdominal, pelvic, and pregnancy imaging that the Glasgow team documented in subsequent clinical publications.

Landmark1968Investigative Radiology1,093 citations

Echocardiography of the Aortic Root

Raymond Gramiak, Pravin M. Shah

To identify the source of two moving echoes on an echocardiogram, the authors injected saline above the aortic valve while recording continuously. A transient cloud of echoes appeared between the two traces of the aortic root. Blood entering from the left ventricle during systole interrupted the cloud as the valve opened.

SignificanceThe enhanced echoes let the team use flowing blood to verify the anatomical origin of the traces. The group published further contrast experiments in 1969. A University of Rochester retrospective documents the subsequent research that identified bubbles as the source of enhanced echoes.

Landmark1991Ultrasonic Imaging4,232 citations

Elastography: A Quantitative Method for Imaging the Elasticity of Biological Tissues

J. Ophir, I. Céspedes … X. Li

The authors recorded ultrasound echoes before and after a small compression and used shifts between the signals to estimate displacement at successive depths. Spatial changes in the displacements gave local strain estimates, producing an image that showed regions deforming differently from their surroundings.

SignificanceThe paper established a workflow for estimating local tissue strain from displacement recorded by ultrasound echoes. Later strain elastography used the same principle to display relative tissue deformation alongside grayscale anatomy, adding information on the mechanical response to compression.

Landmark1998Ultrasound in Medicine & Biology1,957 citations

Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics

Armen P. Sarvazyan, Oleg V. Rudenko … Stanislav Y. Emelianov

The authors proposed using the radiation force of focused ultrasound to generate a localized shear wave inside tissue and using propagation to estimate shear elasticity. They combined theoretical and experimental work to examine the induced displacement and the properties of the resulting waves.

SignificanceThe proposal placed the excitation within tissue and made wave propagation the basis of the elasticity measurement. Later ultrasound shear wave methods retained acoustic radiation force as the excitation mechanism and used faster echo imaging to track the resulting waves.

Landmark2004IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control2,779 citations

Supersonic shear imaging: a new technique for soft tissue elasticity mapping

Jérémy Bercoff, Mickaël Tanter, Mathias Fink

The researchers moved the location of focused acoustic excitation so that the resulting shear waves added coherently. An ultrafast scanner tracked propagation and the team reconstructed elasticity maps from the recorded motion, demonstrating the method in heterogeneous phantoms and healthy volunteers.

SignificanceCombining acoustic excitation with ultrafast imaging made it possible to form two-dimensional maps of mechanical properties from propagating shear waves. Later clinical work in the breast evaluated the additional information such maps could provide alongside conventional grayscale findings.

Landmark2004Clinical Physiology and Functional Imaging321 citations

The Use of Ultrasonic Reflectoscope for the Continuous Recording of the Movements of Heart Walls.

I. Edler, C. H. Hertz

Edler and Hertz first published the experiment in the Royal Physiographic Society of Lund’s proceedings in 1954. In the report, reprinted in 2004, they used a reflectoscope to measure echo depths along one beam through the chest wall and recorded the movement of cardiac structures over the cardiac cycle.

SignificanceContinuous pulse-echo recording of cardiac motion developed into motion-mode echocardiography. The work at Lund showed how valve motion could be examined through the chest and led to applications in the evaluation of mitral valve disease.

Key1968Ultrasonics196 citations

Electronic sector scanning for ultrasonic diagnosis

J. C. Somer

Somer developed an electronically controlled ultrasound sector scanner to overcome the slow refresh of mechanical B-scanning. An array of 21 elements steered pulses across a 90-degree sector and could repeat the scan across that sector about 30 times per second.

SignificanceThe work showed that an array could sweep a beam across a sector repeatedly without moving the probe. A follow-up report applied this electronic scanner to neurological cases, and phased arrays became a means of acquiring real-time cardiac sections.

Key1990Journal of Digital Imaging271 citations

Real time volumetric ultrasound imaging system

Olaf T. von Ramm, Stephen W. Smith

The authors used a 289-element two-dimensional phased array to scan a pyramidal volume with pulse echoes. Parallel processing on reception produced approximately eight volume acquisitions per second and also let the system display sections selected from the acquired three-dimensional data.

SignificanceThe prototype combined a two-dimensional array, parallel reception, and section display from acquired volumes to show how rapidly changing anatomy could be scanned in three dimensions. Later real-time three-dimensional echocardiography developed this approach using matrix-array transducers.

Key1995The Journal of Trauma453 citations

A Prospective Study of Surgeon-Performed Ultrasound as the Primary Adjuvant Modality for Injured Patient Assessment

Grace S. Rozycki, M. Gage Ochsner … Howard R. Champion

In a prospective series of 371 injured patients, trained surgeons used ultrasound to look for intraperitoneal blood or pericardial fluid. Ultrasound detected 53 of 65 patients with significant injuries, and the investigators reported a sensitivity of 81.5% and specificity of 99.7%.

SignificanceThe series provided prospective evidence for surgeon-performed ultrasound in the initial assessment of trauma. Subsequent clinical practice reports documented the focused assessment with sonography for trauma as a rapid way to look for fluid that required further assessment.

Key2003Ultrasound in Medicine & Biology3,058 citations

Transient elastography: a new noninvasive method for assessment of hepatic fibrosis

Laurent Sandrin, Bertrand Fourquet … Frédéric Mal

The team used ultrasound to follow a transient shear wave generated by external vibration and estimated liver stiffness from the propagation speed. In 106 patients with chronic hepatitis C, the measurements were reproducible and correlated with the fibrosis stage determined by biopsy.

SignificanceThe study provided biopsy-referenced human evidence for transient elastography as a noninvasive way to assess liver fibrosis. A subsequent prospective comparison evaluated liver stiffness measurements alongside serum fibrosis markers and examined how they could be used together.

Key2008Chest2,690 citations

Relevance of Lung Ultrasound in the Diagnosis of Acute Respiratory Failure: The BLUE Protocol

Daniel A. Lichtenstein, Gilbert A. Mezière

The investigators performed bedside ultrasound in patients admitted with acute respiratory failure and combined findings such as lung sliding, lung artifacts, and venous ultrasound into diagnostic profiles. They compared the resulting profiles with final diagnoses to assess discrimination among common causes of respiratory failure.

SignificanceThe report provided a structured, reproducible bedside ultrasound examination for investigating acute respiratory failure. Its combination of lung artifacts, pleural motion, and venous findings gave subsequent emergency and intensive care ultrasound studies a protocol they could evaluate.

Key2009IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control2,057 citations

Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography

Gabriel Montaldo, Mickaël Tanter … Mathias Fink

The authors improved single plane-wave images by coherently summing echoes from transmissions at different angles. Their model predicted image quality comparable to conventional B-mode imaging with roughly one-tenth as many transmissions. Tissue-mimicking phantom experiments supported the prediction, and the paper also demonstrated its application to transient elastography.

SignificanceCoherent compounding provided a way to improve image quality with a limited number of additional transmissions while preserving high frame rates for tasks such as shear wave tracking. Urs and colleagues explicitly credited the method and adapted it to image anatomy and blood flow in the human eye.

Key2011The New England Journal of Medicine2,092 citations

Point-of-Care Ultrasonography

Christopher L. Moore, Joshua A. Copel

This review defined point-of-care ultrasonography as imaging performed and interpreted by the treating clinician at the bedside. It surveyed trauma assessment, thoracic imaging, aneurysm screening, and procedural guidance, pairing the discussion of training and implementation with videos demonstrating specific examinations.

SignificanceThe review gave clinicians across specialties a shared description of focused bedside examinations and the training needed to implement them. Subsequent professional practice parameters gave more specific guidance on indications, examination content, documentation, and quality processes.

Key2014IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control1,356 citations

Ultrafast imaging in biomedical ultrasound

Mickaël Tanter, Mathias Fink

This review explained how plane or diverging wave transmission illuminates a broad region and allows many image locations to be reconstructed from the received array signals. It discussed frame rates above a thousand per second and applications to elasticity imaging and blood flow measurements.

SignificanceThe review linked plane- and diverging-wave acquisition to shear wave tracking and blood flow measurement through a shared beamforming framework. Urs and colleagues cited it when introducing the acquisition principles in their subsequent ocular study, which used compounded plane waves to depict anatomy and flow.

Key2014The New England Journal of Medicine748 citations

Ultrasonography versus Computed Tomography for Suspected Nephrolithiasis

Rebecca Smith-Bindman, Chandra Aubin … Jill Corbo

This multicenter trial randomly assigned 2,759 patients with suspected kidney stones to point-of-care ultrasound, radiology ultrasound, or CT as the initial study. The ultrasound groups had lower cumulative radiation exposure over six months, with no significant difference in high-risk diagnoses with complications within 30 days.

SignificanceThe trial compared initial imaging strategies using patient outcomes and cumulative radiation exposure, while allowing additional imaging at the treating physician's discretion. It provided comparative evidence for starting with ultrasound in selected emergency patients with suspected kidney stones.

Notable1942Zeitschrift für die gesamte Neurologie und Psychiatrie370 citations

Über die Möglichkeit, hochfrequente mechanische Schwingungen als diagnostisches Hilfsmittel zu verwerten

Karl Theo Dussik

Dussik measured transmitted ultrasound across a grid on a formalin-fixed specimen from the right cerebral hemisphere. Figure 3 displays the variation in transmitted intensity through the specimen, which contained part of a ventricle. In a separate experiment, he detected a signal after sending ultrasound from one temple to the other through a human head.

SignificanceThe study was an early investigation of intracranial ultrasound transmission. Dussik published images from later work in 1947, interpreting the patterns as ventricular anatomy. In 1952, Güttner and colleagues showed experimentally that attenuation by the skull could account for those patterns.

Notable2025CVPR 202528 citations

EchoWorld: Learning Motion-Aware World Models for Echocardiography Probe Guidance

Yang Yue, Yulin Wang … Gao Huang

EchoWorld pretrains on echocardiography sequences and probe motion by predicting masked regions and image features following probe adjustments. The adapted model estimates probe moves toward standard views from the history of images and motion. The evaluation compared these estimates with acquisitions recorded from healthy adult men.

SignificanceConnecting probe movements to the next observation makes predictive pretraining directly relevant to image acquisition. The guidance experiments assess this approach by testing predictions of how the probe needs to move to reach a standard echocardiographic view.