ROC curve and AUCAUC
ROC曲线与AUC
The ROC curve plots sensitivity against one minus specificity as a test's threshold is swept from strict to lenient. The area under it, the AUC, sums up discriminating power in one number between 0.5 (chance) and 1.
ROC stands for receiver operating characteristic, a name inherited from Second World War radar: operators had to pick enemy aircraft out of noise, and the looser their threshold, the more planes they caught and the more false alarms they raised. The idea grew into signal detection theory in the 1950s, and from around 1960 Lee Lusted and others brought it into radiology to compare readers and imaging methods.
In 1982 James Hanley and Barbara McNeil showed in Radiology that the area under the curve equals the probability that, given one randomly chosen diseased and one non-diseased patient, the test rates the diseased one as more suspicious. An AUC of 0.5 is equivalent to a coin toss; 0.9 means nine such pairs in ten are ordered correctly.
Because it does not depend on a threshold, AUC makes models easy to compare, and nearly every imaging AI paper reports it. But it does not say where a test should operate, and for rare diseases it can look flattering. Deployment still means choosing a threshold and living with the resulting sensitivity and specificity.
- Hanley JA, McNeil BJ. The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology. 1982;143(1):29–36. doi.org/10.1148/radiology.143.1.7063747
- Lusted LB. Logical analysis in roentgen diagnosis. Radiology. 1960;74:178–193.
Key works · 18
Landmark1982Radiology24,806 citations
The meaning and use of the area under a receiver operating characteristic (ROC) curve.
The paper interpreted the area under an ROC curve from graded readings or continuous scores as the probability that a randomly selected affected case ranks above an unaffected case. Relating the probability to the Wilcoxon statistic yielded practical approximations for standard errors and study sample sizes.
SignificanceThe interpretation gave reader studies a common meaning for a summary across rating thresholds and a way to plan precision. Later clinical evaluation guidance places that summary alongside threshold-specific performance, which is needed when a scoring system will be used at a defined operating point.
DOI James A. HanleyBarbara J. McNeil ROC curve and AUCsensitivity and specificityreader study
Landmark1988Biometrics25,065 citations
Comparing the Areas under Two or More Correlated Receiver Operating Characteristic Curves: A Nonparametric Approach
Diagnostic tests evaluated on the same participants yield correlated estimates of ROC area. DeLong and colleagues used generalized U-statistics to estimate the covariance matrix of the empirical areas. The resulting nonparametric method compares two or more areas while accounting for the paired study design.
SignificanceThe method is a widely used statistical baseline for comparing tests or readers on shared cases, with implementations in statistical software. Studies of chest radiograph classifier generalization have used it to assess differences in ROC area across their planned test comparisons.
DOI Elizabeth R. DeLongDaniel L. Clarke-Pearson ROC curve and AUCreader study
Landmark2016JAMA9,321 citations
Development and Validation of a Deep Learning Algorithm for Detection of Diabetic Retinopathy in Retinal Fundus Photographs
The authors trained a convolutional network on 128,175 graded fundus photographs and tested it for referable diabetic retinopathy on EyePACS-1 and Messidor-2. The reference was the majority judgment of ophthalmologists. The model achieved AUCs of 0.991 and 0.990 on the two retrospective validation datasets.
SignificanceThis study provided a large retrospective benchmark for automated screening from fundus photographs. A follow-up study examined the implications of its reference-standard choice, comparing majority grading with adjudication by retina specialists and quantifying the resulting differences in evaluation.
DOI Varun GulshanLily PengDale R. Webster fundus photographyROC curve and AUCsensitivity and specificity
Landmark2017JAMA4,056 citations
Diagnostic Assessment of Deep Learning Algorithms for Detection of Lymph Node Metastases in Women With Breast Cancer
CAMELYON16 compared algorithms for finding breast cancer metastases in lymph-node whole-slide images. On 129 held-out slides, the best algorithm achieved a slide-level AUC of 0.994. The comparison included eleven time-constrained pathologists and a separate pathologist who read without a time limit.
SignificanceThe evaluation provided a shared task for whole-slide metastasis detection and showed how the reader comparison depended on the conditions of interpretation. CAMELYON17 extended the benchmark from finding metastases on individual slides to estimating nodal status at the patient level.
DOI Full text Babak Ehteshami BejnordiJeroen A. W. M. van der Laak CAMELYONwhole-slide imagereader studyROC curve and AUC
Landmark2019Nature Medicine2,876 citations
End-to-end lung cancer screening with three-dimensional deep learning on low-dose chest computed tomography
A volumetric model estimates lung cancer risk from low-dose chest CT, incorporating a prior scan when available. It achieved an AUC of 0.944 on held-out National Lung Screening Trial cases. The study also evaluated 1,139 independent clinical cases and compared readers with and without prior imaging.
SignificanceThe study provided an early end-to-end benchmark for lung screening from volumetric CT and made the availability of prior imaging explicit in the reader comparison. Sybil cites this work and extends the question to multiyear risk estimation from a single scan.
DOI Diego ArdilaDaniel TseShravya Shetty low-dose CTROC curve and AUCreader studyexternal validation
Landmark2020Nature4,409 citations
International evaluation of an AI system for breast cancer screening
The authors evaluated a mammography screening model retrospectively in UK and US cohorts and ran a separate reader study with six radiologists. They reported false-positive and false-negative performance by cohort and simulated how the model might interact with the UK double-reading workflow.
SignificanceThe use of separate national cohorts and a reader study provided evidence for evaluating mammography models under different screening conditions. The later methodological addendum made more of the optimization and augmentation setup available for assessing reproducibility of the retrospective results.
DOI Scott Mayer McKinneyDaniel TseShravya Shetty mammographyreader studyexternal validationROC curve and AUC
Landmark2024Nature Medicine1,154 citations
A foundation model for clinical-grade computational pathology and rare cancers detection
Virchow used self-supervised learning on tiles drawn from roughly 1.5 million slides. A detector built on its features achieved a specimen-level area under the ROC curve of 0.95 across nine common and seven rare cancers. The study also assessed cell identification and biomarker prediction.
SignificanceVirchow included rare cancers in a pan-cancer evaluation and compared the labeling requirements of a shared encoder with those of tissue-specific systems. PRISM reused Virchow tile embeddings to train a slide encoder with pathology reports. An independent study subsequently included Virchow in a comparison spanning multiple pathology tasks.
DOI arXiv Full text Eugene VorontsovSiqi LiuThomas J. Fuchs foundation modelwhole-slide imageself-supervised learningROC curve and AUC
Key1983Radiology7,586 citations
A Method of Comparing the Areas under Receiver Operating Characteristic Curves Derived from the Same Cases
The authors compared ROC areas estimated from the same patients under two reading conditions. Using a binormal assumption, they derived a table that converts correlation between paired ratings into correlation between areas. Accounting for that correlation in the standard error of the area difference can increase statistical power.
SignificanceThis paper provided a parametric method for accounting for shared cases in reader or test comparisons. A later methodological study of sample size and power still used the Hanley–McNeil calculation to estimate the variance of differences between correlated ROC areas for continuous diagnostic scores.
DOI Full text James A. HanleyBarbara J. McNeil ROC curve and AUCreader study
Key1989Medical Physics221 citations
Maximum likelihood analysis of free-response receiver operating characteristic (FROC) data
For reader studies that require localization, the paper modeled the scores of signal marks and the production of false-positive marks in free-response ROC data. FROCFIT estimated model parameters and their uncertainties with maximum likelihood. The author reported fits to several experimental data sets.
SignificanceThe paper supplied a statistical model for experiments in which readers can mark several locations per image. Free-response analysis later informed reader-based imaging benchmarks, including the low-dose CT challenge that used a jackknife alternative for evaluating marks of liver metastases.
DOI Dev P. Chakraborty object detectionreader studyROC curve and AUCfree-response ROC
Key1990Investigative Radiology409 citations
Improvement in Radiologists' Detection of Clustered Microcalcifications on Mammograms: The Potential of Computer-Aided Diagnosis
The authors tested whether displaying computer-generated marks improved radiologists' detection of clustered microcalcifications. They compared aided and unaided readings in a controlled setting intended to resemble rapid screening interpretation, finding significantly better detection accuracy with the computerized aid by ROC analysis.
SignificanceThe study evaluated the performance of radiologists using the detector outputs. The history published by Medical Physics identifies it as an early controlled comparison of aided and unaided readings, an approach that preceded evaluations of recall and cancer detection in practice.
DOI Heang‐Ping ChanHeber MacMahon computer-aided detection & diagnosismammographyreader studyROC curve and AUC
Key2003Ultrasound in Medicine & Biology3,058 citations
Transient elastography: a new noninvasive method for assessment of hepatic fibrosis
The team used ultrasound to follow a transient shear wave generated by external vibration and estimated liver stiffness from the propagation speed. In 106 patients with chronic hepatitis C, the measurements were reproducible and correlated with the fibrosis stage determined by biopsy.
SignificanceThe study provided biopsy-referenced human evidence for transient elastography as a noninvasive way to assess liver fibrosis. A subsequent prospective comparison evaluated liver stiffness measurements alongside serum fibrosis markers and examined how they could be used together.
DOI Laurent SandrinRobert Palau elastographyultrasound imagingROC curve and AUC
Key2005New England Journal of Medicine2,187 citations
Diagnostic Performance of Digital versus Film Mammography for Breast-Cancer Screening
In DMIST, 49,528 asymptomatic women underwent both digital and film screening mammography. Readers interpreted the images independently, and complete data were available for 42,760 women. Receiver operating characteristic analysis showed similar overall accuracy, with higher accuracy for digital mammography among women under 50, women with dense breasts, and premenopausal or perimenopausal women.
SignificanceThe paired design established a direct comparison during the transition from film to digital screening. The National Cancer Institute uses DMIST when summarizing the evidence on digital mammography, including the observed differences by age and breast density.
DOI Etta D. PisanoMurray Rebner mammographydigital radiographyROC curve and AUC
Key2017Radiology2,098 citations
Deep Learning at Chest Radiography: Automated Classification of Pulmonary Tuberculosis by Using Convolutional Neural Networks
The authors applied AlexNet and GoogLeNet to pulmonary tuberculosis classification on chest radiographs, comparing pretraining, augmentation, and ensembling. An ensemble of the two architectures achieved an AUC of 0.99 on the held-out test split, and the study examined expert review of discordant cases.
SignificanceThe study supplied an early radiology benchmark for transferring general-purpose convolutional networks to chest radiograph tuberculosis detection. Its experiments also compared stand-alone predictions with an expert arbitration workflow, anticipating the distinction between algorithm evaluation and assisted interpretation.
DOI Paras LakhaniBaskaran Sundaram radiographyconvolutional neural networkROC curve and AUCtransfer learning
Key2018PLOS Medicine1,844 citations
Deep learning for chest radiograph diagnosis: A retrospective comparison of the CheXNeXt algorithm to practicing radiologists
CheXNeXt was evaluated on 420 frontal chest radiographs for 14 findings, using majority judgments from three cardiothoracic radiologists as the reference. In the retrospective comparison with nine additional readers, the authors classified performance as comparable for ten findings, higher for one, and lower for three.
SignificanceThe journal study expanded the earlier pneumonia comparison into a per-finding reader evaluation with a separately defined reference panel. Its breakdown makes clear which findings drove the overall agreement and provides a bounded reference for later work on external clinical populations.
DOI Full text Pranav RajpurkarMatthew P. Lungren ChestX-ray14reader studyground truthROC curve and AUC
Key2023Radiology214 citations
Methods for Clinical Evaluation of Artificial Intelligence Algorithms for Medical Diagnosis
The review covers external testing, performance measures, and reporting for diagnostic algorithms. It discusses paired designs for comparing interpretations with and without assistance on the same cases and parallel designs for evaluating the effect of an intervention. Radiology examples illustrate reader order, washout, and randomized trial design.
SignificanceThe review gives readers a common reference for linking each clinical question to an appropriate design. Its audit of two radiology journals found paired designs in 22 of 24 studies comparing assisted and unassisted diagnosis, illustrating how the published evidence was produced.
DOI Seong Ho ParkJaesoon Choi external validationreader studyROC curve and AUC
Key2023Journal of Clinical Oncology391 citations
Sybil: A Validated Deep Learning Model to Predict Future Lung Cancer Risk From a Single Low-Dose Chest Computed Tomography
Sybil estimates future lung cancer risk from one low-dose chest CT over a period of up to six years without clinical inputs or nodule annotations at inference. The authors report separate validation results in held-out NLST data and hospital cohorts in the United States and Taiwan.
SignificanceThe model extended CT screening research from identifying existing lesions to estimating risk over several years. The released model enabled external evaluations, including a later screening cohort with predominantly Black participants in which investigators separately reported discrimination.
DOI Full text Peter G. MikhaelLecia V. SequistRegina Barzilay low-dose CTexternal validationROC curve and AUC
Notable1996IEEE Transactions on Medical Imaging471 citations
Classification of mass and normal breast tissue: a convolution neural network classifier with spatial domain and texture images
The authors used a convolutional network to classify manually selected mammogram regions as masses or normal tissue. They compared how downsampled intensities and images of local texture features worked as inputs. In a study of 168 confirmed mass regions and 504 normal regions, the best test AUC was 0.87.
SignificanceThe study documented early convolutional classification of mammographic masses and tested how engineered texture measurements could be used as network inputs. Later work on large-scale mammographic lesion detection cited the study as an early application of convolutional networks to mammography.
DOI Berkman SahinerMitchell M. Goodsitt computer-aided detection & diagnosismammographyconvolutional neural networktexture analysisROC curve and AUC
Notable2026The Lancet Digital Health9 citations
MerMED-FM: Multimodal, Multi-Disease Medical Imaging Foundation Model
MerMED-FM pretrained a shared visual encoder on about 3.3 million unlabeled images across seven imaging modalities, then fine-tuned and evaluated it using 26 public and five private datasets. With 10% of labels available for fine-tuning, mean AUROC by modality ranged from 0.810 to 0.962.
SignificanceBy comparing the shared encoder with generalist and specialist models at specified label fractions, the study provides a benchmark for testing how well one visual backbone adapts to tasks in radiology, pathology, and ophthalmology with limited annotation.
DOI arXiv Daniel Shu Wei Ting foundation modelmultimodal learningself-supervised learningROC curve and AUCunified representation