Landmark2016JAMA9,321 citations
Development and Validation of a Deep Learning Algorithm for Detection of Diabetic Retinopathy in Retinal Fundus Photographs
The authors trained a convolutional network on 128,175 graded fundus photographs and tested it for referable diabetic retinopathy on EyePACS-1 and Messidor-2. The reference was the majority judgment of ophthalmologists. The model achieved AUCs of 0.991 and 0.990 on the two retrospective validation datasets.
SignificanceThis study provided a large retrospective benchmark for automated screening from fundus photographs. A follow-up study examined the implications of its reference-standard choice, comparing majority grading with adjudication by retina specialists and quantifying the resulting differences in evaluation.
DOI Varun GulshanLily PengDale R. Webster fundus photographyROC curve and AUCsensitivity and specificity