Evaluation & clinic

inter-observer variability

观察者间差异

How much experts disagree when they read the same image or outline the same structure. It shows how hard the task really is, and sets a realistic bar for what human-level performance means for an algorithm.

Radiology confronted the problem early. In 1947 the statistician Jacob Yerushalmy, comparing methods of chest X-ray screening for tuberculosis, found that readers often disagreed with one another, and even with themselves on a second reading. Agreement is now usually summarized with Cohen's kappa (1960), , which discounts the agreement expected by chance.

The numbers can be striking. In the LIDC-IDRI lung CT database, four thoracic radiologists independently annotated 1,018 cases. Of 2,669 lesions that at least one of them called a nodule of 3 mm or more, only 928 (34.7%) were marked by all four. Outlines of tumor boundaries vary just as much from reader to reader.

For AI evaluation this has two consequences. A reference standard drawn by one annotator carries that person's preferences, and once a model's Dice score against an expert approaches the Dice between experts, chasing a higher number means little.

Sources
  1. Yerushalmy J. Statistical problems in assessing methods of medical diagnosis, with special reference to X-ray techniques. Public Health Rep. 1947;62(40):1432–1449. doi.org/10.2307/4586294
  2. Armato SG 3rd, McLennan G, Bidaut L, et al. The Lung Image Database Consortium (LIDC) and Image Database Resource Initiative (IDRI): a completed reference database of lung nodules on CT scans. Med Phys. 2011;38(2):915–931. doi.org/10.1118/1.3528204
  3. Cohen J. A coefficient of agreement for nominal scales. Educ Psychol Meas. 1960;20(1):37–46.

Key works · 10

Landmark2011Medical Physics3,570 citations

The Lung Image Database Consortium (LIDC) and Image Database Resource Initiative (IDRI): A Completed Reference Database of Lung Nodules on CT Scans

Samuel G. Armato, Geoffrey McLennan … Anthony P. Reeves

The collection comprised 1,018 thoracic CT cases. Four radiologists independently marked lesions and then reviewed other readers' anonymized marks before finalizing their own. Of 2,669 findings marked as nodules at least 3 mm by any reader, 928 received that mark from all four.

SignificancePreserving reader-level marks allowed studies to account for disagreement when building nodule references. LUNA16 later used a subset of these scans and annotations to create a standardized detection benchmark with shared definitions for candidates and false positives.

Landmark2015IEEE Transactions on Medical Imaging8,349 citations

The Multimodal Brain Tumor Image Segmentation Benchmark (BRATS)

Bjoern H. Menze, Andras Jakab … Justin Kirby

The paper reported the 2012 and 2013 brain tumor segmentation challenges, comparing 20 algorithms on 65 clinical multicontrast scans and 65 simulated scans. Human rater agreement for tumor subregions ranged from 74% to 85% Dice, and methods ranked differently across subregions.

SignificanceBraTS established shared multimodal inputs, tumor subregion labels, and evaluation for glioma segmentation. Subsequent rounds extended the data and benchmark while retaining common tasks, allowing successive methods to be compared within a sustained challenge series.

Landmark2018NeurIPS 2018840 citations

A Probabilistic U-Net for Segmentation of Ambiguous Images

Simon Kohl, Bernardino Romera-Paredes … Klaus Maier-Hein

Probabilistic U-Net combines a U-Net with a conditional variational autoencoder to sample several coherent masks for one image. The authors compare the diversity and frequency of sampled masks with available annotations in lung abnormality segmentation and in a modified street-scene segmentation task.

SignificanceThe paper represents disagreement between annotators as a distribution over complete masks, allowing coherent outlines to be sampled and compared. PHiSeg extends this perspective with a hierarchy of latent variables that can account for differences at multiple spatial resolutions.

Landmark2018Nature Communications506 citations

Why rankings of biomedical image analysis competitions should be interpreted with care

Lena Maier-Hein, Matthias Eisenmann … Patrick Scholz

The authors examined published biomedical imaging challenges and recomputed rankings under alternative conditions. Rankings often changed when the test cases, reference observer, or aggregation scheme changed. The survey also found that reports frequently omitted methodological information required to reproduce the comparisons.

SignificanceThe analysis showed how challenge design choices can materially change the resulting leaderboard. It informed structured challenge proposals at MICCAI and provided the empirical basis for the BIAS guidance on documenting data, reference standards, assessment measures, and rankings.

Key2004IEEE Transactions on Medical Imaging2,365 citations

Simultaneous Truth and Performance Level Estimation (STAPLE): An Algorithm for the Validation of Image Segmentation

Simon K. Warfield, Kelly H. Zou, William M. Wells III

STAPLE starts with several human or algorithm-generated segmentations. It uses expectation maximization to estimate the probability of a reference label at each voxel while estimating sensitivity and specificity for each input segmentation. The authors demonstrated the approach on synthetic and clinical images.

SignificanceThe approach made it possible to estimate rater reliability and a consensus reference within the same model. ITK provides an implementation that produces a probability map from multiple segmentations, allowing the procedure to be reused in validation and label-fusion workflows.

Key2009IEEE Transactions on Medical Imaging1,272 citations

Comparison and Evaluation of Methods for Liver Segmentation From CT Datasets

T. Heimann, B. van Ginneken … C. Bauer

The study compared 16 liver segmentation methods from the MICCAI 2007 challenge using 20 annotated training volumes and 10 common test volumes. Five measures were combined in a score calibrated to expert variability. Interactive methods had higher average scores than fully automatic entries.

SignificanceThe shared test set and observer-calibrated score allowed unlike classical methods to be evaluated on the same cases. LiTS extended this line of work with multicenter CT and lesion masks, enabling separate evaluation of organ and tumor segmentation.

Key2018Ophthalmology667 citations

Grader Variability and the Importance of Reference Standards for Evaluating Machine Learning Models for Diabetic Retinopathy

Jonathan Krause, Varun Gulshan … Dale R. Webster

The study compares diabetic retinopathy grades assigned independently by ophthalmologists with a reference established by adjudicating disagreements among retina specialists. The authors then measure how the choice between majority grading and adjudication changes reported performance for both machine learning and individual readers.

SignificanceThe comparison made the construction of the reference standard an explicit part of diagnostic evaluation. The subsequent prospective screening cohort in Thailand also assessed retinal-image classification and referral recommendations against an adjudicated reference supplied by fellowship-trained retina specialists.

Key2019MICCAI 2019 (LNCS 11765)349 citations

PHiSeg: Capturing Uncertainty in Medical Image Segmentation

Christian F. Baumgartner, Kerem C. Tezcan … Khoschy Schawkat

PHiSeg places conditional latent variables at several spatial resolutions to sample alternative masks for a given image. The authors evaluate those distributions on lung nodule CT with contours from multiple readers and compare the hierarchical design with earlier probabilistic segmentation approaches.

SignificanceThe hierarchy offers an explicit way to represent annotation differences at several scales, from coarse boundaries to local details. PHiSeg supplies a reproducible comparison to the single-latent design of Probabilistic U-Net and makes the implementation available.

Key2020Medical Image Analysis921 citations

Deep learning with noisy labels: Exploring techniques and remedies in medical image analysis

Davood Karimi, Haoran Dou … Ali Gholipour

The authors reviewed sources of label noise in medical imaging and methods for handling them. They compared remedies in three case studies, including fetal brain segmentation. In one experiment, many mildly noisy masks supported better performance than a much smaller set of manual masks, illustrating dependence on the form of the noise.

SignificanceThe review coupled a taxonomy of noisy labels with experiments that compared remedies under different annotation processes. It became a reference for the medical imaging label-noise literature, where both the mechanism producing errors and the clinical task affect whether a mitigation helps.

Key2022Scientific Data662 citations

VinDr-CXR: An open dataset of chest X-rays with radiologist’s annotations

Ha Q. Nguyen, Khanh Lam … Dung B. Nguyen

VinDr-CXR released 18,000 chest radiographs from two Vietnamese hospitals with manual annotations. Labels included boxes for 22 local findings and six image-level categories. Three radiologists annotated each training image independently, while boxes and labels for the test set used a five-reader consensus.

SignificanceReleased localization labels provide a reference for evaluating where a detector marks findings on the image. The documented institutions, annotation process, and training and test partitions also make VinDr-CXR useful for assessment alongside collections originating elsewhere.