computed tomographyCT
计算机断层扫描
An X-ray tube and detector rotate around the body, measuring projections from hundreds of angles; a computer then calculates the attenuation at every point of a cross-section. It gave medicine its first overlap-free slices through the living body and remains the principal modality in emergency and cancer imaging.
Each measurement gives the total attenuation along one ray; the views from all angles form a sinogram, which filtered back-projection or iterative reconstruction turns back into a cross-sectional image. Each voxel holds a value in Hounsfield units, mapped to gray levels through a window width & level setting.
On 1 October 1971 a prototype built by Godfrey Hounsfield at EMI scanned its first patient at Atkinson Morley's Hospital in London: an 80 × 80 image, about five minutes to acquire, showing a cystic tumor in the frontal lobe. Hounsfield shared the 1979 Nobel Prize in Physiology or Medicine with Allan Cormack, who had worked out the mathematics independently.
A modern scanner rotates in well under half a second and resolves sub-millimeter slices, covering chest and abdomen in seconds. The cost is ionizing radiation: a chest CT gives about 6 mSv, two years of natural background, which drives work on low-dose CT and smarter reconstruction.
- Hounsfield GN. Computerized transverse axial scanning (tomography): Part 1. Description of system. Br J Radiol. 1973;46(552):1016–1022. doi.org/10.1259/0007-1285-46-552-1016
- Lasker Foundation. Looking deep into the body. laskerfoundation.org/looking-deep-into-the-body/
- RadiologyInfo.org (RSNA/ACR). Radiation dose in X-ray and CT exams. www.radiologyinfo.org/en/info/safety-xray
Key works · 55
Landmark1973British Journal of Radiology5,075 citations
Computerized transverse axial scanning (tomography): Part 1. Description of system
Hounsfield described a head scanner that measured X-ray transmission through the same section at many angles. A computer estimated the attenuation of the individual elements of the section from those readings. The resulting images resolved differences between soft tissues with similar attenuation.
SignificanceThe EMI system put projection acquisition, numerical reconstruction, and section display into a scanner that could be used on patients. Hounsfield and Cormack shared the 1979 Nobel Prize in Physiology or Medicine for the development of computer-assisted tomography.
DOI Godfrey Newbold Hounsfield computed tomographyattenuation coefficientiterative reconstructionHounsfield unit
Landmark1974Science192 citations
Computerized Transaxial X-ray Tomography of the Human Body
The paper described the ACTA scanner for transaxial imaging of multiple body regions. It reported experience in the brain, orbits, and skull base and discussed the potential of the wider scanner geometry for examining the chest, abdomen, spine, and other regions.
SignificanceACTA extended clinical CT beyond dedicated head examinations. Its geometry allowed cross-sectional imaging in multiple body regions, a capability that would become routine in diagnostic CT. The Smithsonian archives identify ACTA as the first whole-body diagnostic CT system.
DOI Robert S. LedleyH. L. Twigg computed tomographytomographyattenuation coefficient
Landmark1981Medical Physics488 citations
A method for describing the doses delivered by transmission x-ray computed tomography
Shope and colleagues proposed deriving a dose descriptor for a series of contiguous CT sections from a single-scan dose profile. They integrated the profile along the scan axis and tested the estimate at different phantom positions and for different numbers of scans using five types of scanner.
SignificanceThe work introduced the CT dose index as a reproducible descriptor of scanner output. The FDA subsequently adopted the quantity, and modern ICRP guidance uses its volumetric form in setting and assessing diagnostic reference levels for CT.
DOI Thomas B. ShopeGordon C. Johnson radiation dosecomputed tomographyCT dose index
Landmark2006European Radiology1,545 citations
First performance evaluation of a dual-source CT (DSCT) system
This evaluation measured the performance of a scanner with two X-ray tubes and two detector systems offset by approximately a right angle. Electrocardiogram-gated single-segment reconstruction achieved an 83 ms temporal resolution. Acquiring data at two tube voltages also let the authors separate bone from iodine-filled vessels.
SignificanceThe geometry reduced the time interval represented by a cardiac section, addressing motion in coronary imaging. Subsequent commercial systems retained dual sources for fast cardiac acquisitions and also used the two tubes to collect data at different spectra for dual-energy CT.
DOI Thomas G. FlohrBernd M. Ohnesorge computed tomographytemporal resolutiondual-energy CTmaterial decomposition
Landmark2011Medical Physics3,570 citations
The Lung Image Database Consortium (LIDC) and Image Database Resource Initiative (IDRI): A Completed Reference Database of Lung Nodules on CT Scans
The collection comprised 1,018 thoracic CT cases. Four radiologists independently marked lesions and then reviewed other readers' anonymized marks before finalizing their own. Of 2,669 findings marked as nodules at least 3 mm by any reader, 928 received that mark from all four.
SignificancePreserving reader-level marks allowed studies to account for disagreement when building nodule references. LUNA16 later used a subset of these scans and annotations to create a standardized detection benchmark with shared definitions for candidates and false positives.
DOI Full text Samuel G. ArmatoLaurence P. Clarke LIDC-IDRIcomputed tomographyinter-observer variabilityannotation
Landmark2014Nature Communications5,890 citations
Decoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach
The authors extracted 440 intensity, shape, and texture features from CT images of 1,019 patients with lung or head and neck cancers. They tested prognostic associations in independent cohorts and examined associations between a prognostic radiomic signature and gene-expression patterns.
SignificanceA four-feature signature developed in a lung cancer cohort showed prognostic associations in separate lung and head and neck cancer cohorts. This established an example of cross-cohort prognostic validation. PyRadiomics later supplied shared implementations for extracting related categories of imaging features.
DOI Full text Hugo J.W.L. AertsPhilippe Lambin radiomicscomputed tomographytexture analysisexternal validation
Key1973British Journal of Radiology997 citations
Computerized transverse axial scanning (tomography): Part 2. Clinical application
Ambrose described how to read the sections produced by the early head scanner. Anatomical structures could be localized and characterized by attenuation, and deviations could be compared with expected pathological changes. Examples included high attenuation from blood clots and calcification in tumors.
SignificanceThe clinical paper documented that CT could localize and characterize intracranial lesions using the reconstructed tissue attenuation. The historical review in Radiology identifies the first patient examination by Ambrose and Hounsfield as the start of clinical CT.
DOI James Ambrose computed tomographyattenuation coefficient
Key1977Journal of Computer Assisted Tomography155 citations
Display of Three-Dimensional Information in Computed Tomography
The authors assembled transverse CT slices into a three-dimensional array and developed software to display a section through that array in an arbitrary orientation. They also demonstrated how to detect an organ boundary and display the isolated structure as a surface.
SignificanceThe study showed that one CT volume could be resampled outside the acquired orientation and also used to depict an organ surface. Both capabilities became functions of subsequent medical workstations for multiplanar reformatting and surface display.
DOI Gábor T. HermanHsun Kao Liu computed tomographyvoxelmultiplanar reconstructionsurface rendering
Key1979Computer Graphics and Image Processing468 citations
Three-dimensional display of human organs from computed tomograms
The authors approximated organ surfaces from CT with small square faces of restricted orientation and adapted a depth buffer to remove hidden surfaces efficiently. They applied low-pass filtering to reduce artifacts from the square approximation and demonstrated the method with actual patient-derived organ volumes.
SignificanceThe work showed that voxel boundaries could be rendered as visible faces for three-dimensional inspection of organs imaged by CT. Drebin and colleagues later described this square-face model when comparing existing surface methods with direct volume rendering.
DOI Gábor T. HermanHsun Kao Liu computed tomographysurface renderingvoxel
Key1984Radiology497 citations
Three dimensional CT reconstruction images for craniofacial surgical planning and evaluation
The authors reconstructed three-dimensional bone and soft tissue surfaces from high-resolution CT contours and adapted computer-aided design methods to complex craniofacial cases. They showed how those surfaces could delineate abnormal anatomy, support surgical planning, and assist quantitative evaluation after surgery.
SignificanceThe work brought CT-derived surface models into preoperative and postoperative craniofacial assessment. Follow-up studies showed how clinicians could view skull reconstructions from different directions and selectively hide structures to inspect anatomical relationships obscured in an external view.
DOI Michael W. VannierJ. O. Warren surface renderingcomputed tomographyvoxelthree-dimensional surgical planning
Key1996IEEE Transactions on Nuclear Science196 citations
Attenuation correction of SPECT using X-ray CT on an emission-transmission CT system: myocardial perfusion assessment
The researchers registered data from juxtaposed CT and SPECT scanners and converted the CT measurements to attenuation maps at 140 keV. Attenuation correction reduced underestimation of myocardial activity in a torso phantom and in pigs. An additional partial-volume correction improved agreement with tissue samples in pigs but overestimated activity in the phantom.
SignificanceThis study quantified the benefit and limitations of using registered CT data for attenuation correction on a combined emission–transmission system. UCSF traces its human-scale SPECT/CT prototype for clinical research to the group's work on registered emission and transmission imaging.
DOI Stephen C. BlankespoorBruce H. Hasegawa single-photon emission computed tomographycomputed tomographyattenuation correction
Key1999The New England Journal of Medicine814 citations
A Comparison of Virtual and Conventional Colonoscopy for the Detection of Colorectal Polyps
In a prospective study of 100 patients at high risk of colorectal neoplasia, the investigators reconstructed endoluminal views from helical CT and compared the findings with conventional colonoscopy in the same patients. The virtual examination detected a greater proportion of larger polyps than of smaller ones.
SignificanceComparing CT endoluminal display with conventional colonoscopy in the same patients moved virtual endoscopy from feasibility testing to clinical assessment by lesion size. Subsequent research extended the evaluation from a high-risk study population to asymptomatic people undergoing screening.
DOI Helen M. FenlonJoseph T. Ferrucci computed tomographyhelical CTendoscopysurface renderingCT colonography
Key2002IEEE Visualization 2002214 citations
CPR - Curved Planar Reformation
The authors resampled CT volumes along a vessel centerline to display the lumen, wall, and surrounding tissue of a curved vessel in one image. They compared three reformations using a scanned tube phantom and presented thick, rotating, and multipath variants.
SignificanceThe study made explicit how curved reformations display long vessel segments within a single view and how the chosen method changes the representation of length, orientation, and branches. A subsequent paper extended multipath reformation to display an entire vascular tree.
DOI Full text Armin KanitsarMeister Eduard Gröller multiplanar reconstructionangiographycomputed tomographyinterpolation
Key2003The New England Journal of Medicine2,123 citations
Computed Tomographic Virtual Colonoscopy to Screen for Colorectal Neoplasia in Asymptomatic Adults
The researchers examined 1,233 asymptomatic adults with virtual and optical colonoscopy on the same day. CT readers initially searched a three-dimensional endoluminal display for polyps. With final optical findings after segmental unblinding as the reference, CT colonography had a per-patient sensitivity of 93.8% for adenomatous polyps at least 10 mm in diameter.
SignificanceThe study provided screening data for CT colonography using a primary three-dimensional reading method in asymptomatic adults. Later multicenter validation also studied performance by lesion size, providing independent evidence for assessing the technique's use in screening.
DOI Perry J. PickhardtWilliam R. Schindler CT colonographycomputed tomographyendoscopysensitivity and specificity
Key2005Gastroenterology296 citations
Computed Tomographic Virtual Colonoscopy Computer-Aided Polyp Detection in a Screening Population
The study evaluated a computerized polyp detector on CT colonography from a screening population, using optical colonoscopy findings as the reference. The detector generated candidates from local geometry and classified them, with performance reported at both the polyp and patient levels.
SignificanceThe screening cohort provided evidence on candidate detection outside a small enriched case set. Follow-up investigations compared distinct detection systems and assessed radiologists with and without computer marks, clarifying the difference between standalone detection performance and reader benefit.
DOI Full text Ronald M. SummersJ. Richard Choi computer-aided detection & diagnosiscomputed tomographyhand-crafted features
Key2009IEEE Transactions on Medical Imaging1,272 citations
Comparison and Evaluation of Methods for Liver Segmentation From CT Datasets
The study compared 16 liver segmentation methods from the MICCAI 2007 challenge using 20 annotated training volumes and 10 common test volumes. Five measures were combined in a score calibrated to expert variability. Interactive methods had higher average scores than fully automatic entries.
SignificanceThe shared test set and observer-calibrated score allowed unlike classical methods to be evaluated on the same cases. LiTS extended this line of work with multicenter CT and lesion masks, enabling separate evaluation of organ and tumor segmentation.
DOI Full text Tobias HeimannIvo Wolf grand challengeimage segmentationcomputed tomographyinter-observer variability
Key2014The New England Journal of Medicine748 citations
Ultrasonography versus Computed Tomography for Suspected Nephrolithiasis
This multicenter trial randomly assigned 2,759 patients with suspected kidney stones to point-of-care ultrasound, radiology ultrasound, or CT as the initial study. The ultrasound groups had lower cumulative radiation exposure over six months, with no significant difference in high-risk diagnoses with complications within 30 days.
SignificanceThe trial compared initial imaging strategies using patient outcomes and cumulative radiation exposure, while allowing additional imaging at the treating physician's discretion. It provided comparative evidence for starting with ultrasound in selected emergency patients with suspected kidney stones.
DOI Rebecca Smith-BindmanSteven R. Cummings point-of-care ultrasoundultrasound imagingcomputed tomographyradiation dose
Key2015MICCAI 2015 (LNCS 9349)995 citations
DeepOrgan: Multi-level Deep Convolutional Networks for Automated Pancreas Segmentation
DeepOrgan uses a multistage convolutional approach to segment the pancreas in abdominal CT. It first generates dense probabilities from local patches, then classifies candidate regions using both these probability maps and CT intensity. It evaluates the system by cross-validation on manually outlined scans.
SignificanceThe study documents an early progression from local patch classification to a multistage deep pipeline for abdominal organ segmentation. The later Dense V-Network study cites DeepOrgan in its account of prior learning-based pancreas and multi-organ segmentation methods.
DOI arXiv Holger R. RothRonald M. Summers computed tomographyimage segmentationconvolutional neural network
Key2016IEEE Transactions on Medical Imaging6,568 citations
Deep Convolutional Neural Networks for Computer-Aided Detection: CNN Architectures, Dataset Characteristics and Transfer Learning
The authors varied network architecture, dataset size, spatial context, and ImageNet initialization for thoracoabdominal lymph node detection and interstitial lung disease classification on CT. Fine-tuning was effective in the tasks studied. The paper also reported fivefold cross-validation for classifying axial CT slices by interstitial lung disease category.
SignificanceBy varying initialization alongside architecture and training data, this widely cited study showed how to judge transfer alongside other design choices in CT detection and classification. Transfusion later used larger classification datasets and lightweight architectures to test when transfer helped and investigate the source of those gains.
DOI arXiv Full text Hoo-Chang ShinRonald M. Summers transfer learningconvolutional neural networkcomputer-aided detection & diagnosiscomputed tomography
Key2017Medical Image Analysis671 citations
3D deeply supervised network for automated segmentation of volumetric medical images
This work adds auxiliary segmentation losses at intermediate layers of a 3D fully convolutional network so that shallow representations receive direct supervision. A conditional random field refines the masks. The authors evaluated the pipeline on challenge tasks for liver CT and cardiac MRI.
SignificanceThe study documented a single deep supervision design across CT and MRI, with experiments on both hepatic and cardiovascular structures. It also received the 2017 Medical Image Analysis–MICCAI Best Paper Award, as recorded in the first author's publication list.
DOI Full text Qi DouJing QinPheng-Ann Heng computed tomographymagnetic resonance imagingfully convolutional networkimage segmentationdeep supervision
Key2017American Journal of Roentgenology243 citations
Cinematic Rendering in CT: A Novel, Lifelike 3D Visualization Technique
The article explained how cinematic rendering applies global illumination to CT volumes by modeling light propagation, absorption, and scattering. Side-by-side images of an intracranial aneurysm and an aortic stent illustrated how shading changes the cues to the depth and shape of anatomical structures.
SignificanceThe pictorial review provided an early reference for applying global illumination to clinical CT display. Brookmeyer and colleagues cited the article in their 2024 review of implementation, which described how cinematic rendering fits into postprocessing and preprocedural planning.
DOI Marwen H. EidU. Joseph Schoepf computed tomographyvolume rendering
Key2017MICCAI 2017 (LNCS 10435)887 citations
Medical Image Synthesis with Context-Aware Generative Adversarial Networks
This study synthesized CT from MRI with a three-dimensional fully convolutional generator and combined adversarial, voxel, and image-gradient losses. The authors compared the estimated and reference CT images for brain and pelvic cases and reported improvements over the synthesis methods tested.
SignificanceThe paper supplied an early volumetric adversarial baseline for MR-to-CT synthesis and evaluated the same general approach in two anatomical regions. The subsequent journal article extended the investigation to additional synthesis directions and included more comparisons of cross-modality estimation.
DOI Full text Dong NieDinggang Shen generative adversarial networkcomputed tomographymagnetic resonance imaging
Key2017Medical Image Analysis1,681 citations
Validation, comparison, and combination of algorithms for automatic detection of pulmonary nodules in computed tomography images: The LUNA16 challenge
LUNA16 evaluated complete nodule detection and false-positive reduction on a common subset of 888 LIDC-IDRI CT scans. It compared submissions using shared folds and false-positive criteria. Combining several systems yielded sensitivity above 95% at fewer than one false positive per scan.
SignificanceThe two tracks separated the effects of generating candidates and classifying them. By publishing the scan splits, nodule references, and scoring procedure, LUNA16 provided a reproducible comparison for complete systems and specific stages of CT nodule detection.
DOI arXiv Full text Arnaud A. A. SetioColin Jacobs LIDC-IDRIgrand challengecomputer-aided detection & diagnosiscomputed tomography
Key2018MIDL 201812,560 citations
Attention U-Net: Learning Where to Look for the Pancreas
Attention U-Net gates encoder features before they are passed across the skip connections, using coarser features to weight the spatial responses. The authors evaluate multi-organ segmentation on two abdominal CT datasets and report improvements over the corresponding U-Net without attention gates.
SignificanceThe method embedded learned region selection directly within a segmentation architecture, providing a reference for gated U-Net variants. A later journal study of attention gates applies the mechanism to both abdominal CT segmentation and fetal ultrasound plane detection.
arXiv Ozan OktayDaniel Rueckert U-Netskip connectioncomputed tomographyimage segmentationattention gatemulti-organ segmentation
Key2018IEEE Transactions on Medical Imaging790 citations
Automatic Multi-Organ Segmentation on Abdominal CT With Dense V-Networks
A densely connected 3D V-shaped network segments eight organs in abdominal CT without interpatient registration. The authors compared it with multi-atlas and earlier deep methods in cross-validation on 90 multicenter examinations. It yielded higher Dice scores for all organs in those comparisons.
SignificanceBy comparing learned volumetric segmentation with multi-atlas methods on the same scans, the study provided evidence for moving abdominal multi-organ segmentation beyond registration-based workflows. Its released implementation made this specific dense V-shaped architecture available to subsequent researchers.
DOI Full text Eli GibsonDean C. Barratt computed tomographyimage segmentationV-NetDice coefficientdense connectivitymulti-organ segmentation
Key2018Neurocomputing2,365 citations
GAN-based synthetic medical image augmentation for increased CNN performance in liver lesion classification
This study trained adversarial generators to synthesize CT image patches for three classes of liver lesions. The authors added generated patches to the training data and compared the classifier against conventional augmentation. In the experiments, adding class-specific synthetic images improved both sensitivity and specificity.
SignificanceThe study evaluated synthetic examples on a downstream diagnostic classification task and included a conventional-augmentation control. Reviews of medical image augmentation subsequently used it as an early example of training with generated lesion data and measuring the resulting classifier's performance.
DOI arXiv Maayan Frid-AdarHayit Greenspan generative adversarial networkdata augmentationcomputed tomographyimage classificationsynthetic data
Key2018IEEE Transactions on Medical Imaging2,849 citations
H-DenseUNet: Hybrid Densely Connected UNet for Liver and Tumor Segmentation From CT Volumes
H-DenseUNet combines a two-dimensional dense network for extracting within-slice CT features with a three-dimensional branch for aggregating volumetric context. A fusion layer allows joint optimization of both streams. Evaluation on LiTS and 3DIRCADb shows competitive liver segmentation and strong tumor segmentation performance with a single model.
SignificanceThe architecture demonstrated how to combine within-slice detail and cross-slice context for segmenting the liver and lesions in the same CT volume. The LiTS benchmark paper documents the challenge submission, and DefED-Net uses it as a comparator for segmentation on LiTS.
DOI arXiv Xiaomeng LiPheng-Ann Heng computed tomographyU-Netimage segmentationdense connectivity
Key2018IJCAI 2018381 citations
Unsupervised Cross-Modality Domain Adaptation of ConvNets for Biomedical Image Segmentations with Adversarial Loss
A segmentation network learned to delineate four cardiac structures on labeled MR images. A plug-in module then used an adversarial objective to align features from unpaired CT with those from MRI without using CT annotations. On the held-out CT cases, overlap improved for all four structures compared with applying the original MR model directly.
SignificanceThe study made a modality change explicit by comparing direct transfer, adaptation without CT annotations, and training with target labels. The group's PnP-AdaNet extension expanded the evaluation, and later work such as ARL-GAN used that model family as a comparator on the unpaired cardiac MRI-to-CT task.
DOI arXiv Qi DouPheng-Ann Heng domain adaptationimage segmentationmagnetic resonance imagingcomputed tomography
Key2019Scientific Reports803 citations
Data augmentation using generative adversarial networks (CycleGAN) to improve generalizability in CT segmentation tasks
A CycleGAN produced synthetic noncontrast scans from annotated contrast-enhanced CT, which the authors used to augment organ segmentation training. They evaluated performance on real noncontrast cases from a different hospital. Kidney Dice increased from 0.09 to 0.66, while the liver and spleen gains were smaller.
SignificanceThe study connected image synthesis to an external validation task on actual noncontrast scans. Its organ-specific results showed how synthetic augmentation could be evaluated against real target-domain data and why benefits should be measured for each intended segmentation task.
DOI Full text Veit SandfortRonald M. Summers generative adversarial networkdata augmentationexternal validationcomputed tomographycycle consistencysynthetic data
Key2019CVPR 2019353 citations
DuDoNet: Dual Domain Network for CT Metal Artifact Reduction
DuDoNet corrected metal-corrupted sinograms and refined the resulting CT images within one trainable network. A differentiable Radon inversion layer connected the two stages. In the reported experiments, joint processing improved detail recovery and reduced residual and secondary artifacts relative to single-domain approaches.
SignificanceDuDoNet provided a concrete dual-domain baseline for learned metal artifact reduction. Later work on deep sinogram completion with an image prior compared against it when studying how projection continuity at the metal trace boundary affects artifacts after reconstruction.
DOI arXiv Full text Wei-An LinShaohua Kevin Zhou sinogramartifactcomputed tomographymetal artifact reduction
Key2019MICCAI 2019 (LNCS 11765)349 citations
PHiSeg: Capturing Uncertainty in Medical Image Segmentation
PHiSeg places conditional latent variables at several spatial resolutions to sample alternative masks for a given image. The authors evaluate those distributions on lung nodule CT with contours from multiple readers and compare the hierarchical design with earlier probabilistic segmentation approaches.
SignificanceThe hierarchy offers an explicit way to represent annotation differences at several scales, from coarse boundaries to local details. PHiSeg supplies a reproducible comparison to the single-latent design of Probabilistic U-Net and makes the implementation available.
DOI arXiv Christian F. BaumgartnerEnder Konukoglu uncertainty estimationimage segmentationinter-observer variabilitycomputed tomography
Key2020New England Journal of Medicine4,125 citations
Reduced Lung-Cancer Mortality with Volume CT Screening in a Randomized Trial
NELSON randomly assigned 13,195 men in the primary analysis to low-dose CT screening or no screening. Another 2,594 women were included in subgroup analyses. The trial used nodule volumes and growth to guide follow-up. At 10 years the male lung-cancer mortality rate ratio was 0.76, with a 95% confidence interval of 0.61 to 0.94.
SignificanceNELSON supplied randomized mortality evidence for a screening program that used volumetric nodule management and a no-screening control. The US Preventive Services Task Force evidence review identified NELSON and the US National Lung Screening Trial as the two adequately powered trials for lung-cancer mortality.
DOI Harry J. de KoningMatthijs Oudkerk low-dose CTcomputed tomography
Key2021Medical Image Analysis481 citations
Models Genesis
Models Genesis pretrained on unlabeled chest CT by recovering 3D patches after intensity remapping, local voxel shuffling, or masking. The journal study broadened the comparisons across five volumetric classification and segmentation tasks. It reported better performance than training from scratch and the tested 3D pretrained models and 2D and 2.5D transfer approaches.
SignificanceThe 2019 conference paper introduced this restoration approach and released volumetric weights that could initialize models across organs and modalities. The journal paper broadened the baseline comparisons. Parts2Whole subsequently tested Models Genesis alongside other pretrained 3D models.
DOI arXiv Full text Zongwei ZhouJianming Liang self-supervised learningtransfer learningcomputed tomography
Key2021Medical Image Analysis783 citations
The state of the art in kidney and kidney tumor segmentation in contrast-enhanced CT imaging: Results of the KiTS19 challenge
KiTS19 assembled contrast-enhanced CT from 300 patients with renal tumors, using 210 labeled cases for training and 90 for testing. The benchmark evaluated kidney and tumor segmentation separately. Its analysis compared submissions and examined the relation between case characteristics and segmentation performance.
SignificanceThe separate kidney and lesion scores made it possible to assess how organ segmentation performance translated to the tumor task. The challenge also provided the basis for subsequent KiTS rounds with broader case collections and additional label categories.
DOI arXiv Full text Nicholas E. HellerChristopher Weight grand challengeimage segmentationcomputed tomographyDice coefficient
Key2022The Lancet Digital Health878 citations
AI recognition of patient race in medical imaging: a modelling study
The authors train models to predict self-reported race from medical images and test them across institutions and several modalities. They assess proposed proxy variables and perturb the images to investigate the source of the signal. The tested individual proxies did not account for the model's discrimination.
SignificanceThe finding shows why withholding demographic input fields does not prevent a model from accessing population-associated signals in the image itself. Cross-modality and external testing made the paper a reference for auditing fairness in medical image models.
DOI arXiv Full text Judy Wawira GichoyaHaoran Zhang radiographycomputed tomographymammographybias and fairness
Key2022CVPR 20221,363 citations
Self-Supervised Pre-Training of Swin Transformers for 3D Medical Image Analysis
The study pretrains a volumetric Swin model on 5,050 public CT studies using rotation prediction, image inpainting, and a contrastive objective. It evaluates the effect of pretraining by fine-tuning on BTCV abdominal multi-organ segmentation and tasks from the Medical Segmentation Decathlon.
SignificanceThe paper supplied a reproducible self-supervised reference for volumetric encoders. MONAI makes the implementation and pretrained weights available, allowing segmentation studies that use transformers for three-dimensional scans to compare initialization choices without repeating the full pretraining process.
DOI arXiv Full text Yucheng TangAli Hatamizadeh Swin Transformerself-supervised learningcomputed tomographyimage segmentationmulti-organ segmentation
Key2022ICLR 2022865 citations
Solving Inverse Problems in Medical Imaging with Score-Based Generative Models
The researchers learned a generative score prior from medical images and introduced the measurements and their forward operator during sampling at test time. Tests included CT and MRI inverse problems. The study reported comparable or improved reconstruction in several tasks and stronger generalization to changed measurement processes.
SignificanceThe study used a common framework to test score priors across tomographic and MR measurement models. By varying the operator used at inference, it provided a direct evaluation of whether a learned prior could support multiple reconstruction tasks without acquisition-specific paired training.
arXiv Yang SongStefano Ermon inverse problemdiffusion modelcomputed tomographymagnetic resonance imagingdata consistency
Key2023JAMA Neurology130 citations
Automated Large Vessel Occlusion Detection Software and Thrombectomy Treatment Times: A Cluster Randomized Clinical Trial
Four stroke centers introduced large-vessel occlusion detection on CT angiograms and secure group messaging in stages. The order was randomized for three centers, with the academic center assigned to go last in advance. The intervention shortened the time from hospital arrival to arterial puncture for thrombectomy. The trial also assessed 90-day disability in an exploratory analysis.
SignificanceThe trial moved beyond specialist notification, an endpoint in the FDA's early ContaCT decision, to an observed treatment workflow measure. It provides a randomized evaluation of imaging triage in hospitals, with the intervention combining detection software and team communication.
DOI Juan Carlos Martínez-GutiérrezLuca GiancardoSunil A. Sheth angiographycomputed tomographytriageFDA De Novo classification
Key2023Scientific Reports536 citations
Denoising diffusion probabilistic models for 3D medical image generation
The authors trained denoising diffusion models to synthesize three-dimensional CT and MR images. Two radiologists assessed image appearance, anatomy, and consistency across slices. An additional experiment used synthetic images for self-supervised pretraining and reported improved Dice on breast segmentation with scarce training data.
SignificanceThe study gave a cross-modality reference for combining radiologist assessment of synthetic volumes with a downstream experiment. Later MedSyn work included this medical diffusion approach in comparisons of chest CT synthesis, examining anatomy and image quality under the new task.
DOI arXiv Full text Firas KhaderDaniel Truhn diffusion modelmagnetic resonance imagingcomputed tomographyself-supervised learningsynthetic data
Key2023Annals of the ICRP59 citations
Optimisation of Radiological Protection in Digital Radiology Techniques for Medical Imaging
The Commission describes how to optimize protection in digital radiography, fluoroscopy, and CT while preserving image quality adequate for the clinical task. It proposes four levels for facilities to assess their practices, covering equipment selection and monitoring, protocol review, staff training, and collaboration across professions.
SignificancePublication 154 gives digital imaging departments a way to assess their implementation of the Commission's optimization principle in stages. The task group's companion strategy describes how departments can use professional roles, technical capability, and management processes to identify their next steps.
DOI Full text Colin J. MartinJenia Vassileva radiation doseALARAdigital radiographyfluoroscopycomputed tomographydiagnostic reference level
Key2023Nature Medicine412 citations
Risk of hematological malignancies from CT radiation exposure in children, adolescents and young adults
EPI-CT followed 948,174 people in nine European countries who underwent CT before age 22. The researchers reconstructed active bone marrow dose from examination and scanner information. Cumulative dose was associated with hematologic malignancies, with an excess relative risk of 1.96 per 100 mGy and a 95% confidence interval of 1.10 to 3.12.
SignificanceThe study provided a multinational reference estimate for hematologic malignancy following CT in young people by applying a common organ-dose method. The subsequent North American RIC cohort study explicitly compared the two cohorts' risk estimates at 100 mGy.
DOI Full text Magda Bosch de BaseaElisabeth Cardis computed tomographyradiation doseionizing radiation
Key2023Medical Image Analysis2,034 citations
The Liver Tumor Segmentation Benchmark (LiTS)
LiTS compared liver and tumor segmentation methods on contrast-enhanced CT from seven sites, with 131 training and 70 unseen test volumes. The study analyzed 75 algorithm submissions and observed that high segmentation overlap was insufficient to guarantee good tumor detection.
SignificanceThe benchmark let researchers compare organ extent, tumor contours, and lesion detection using the same cases. Its data also supplied the liver task in the Medical Segmentation Decathlon, so the resource supported evaluation both within liver imaging and across anatomical tasks.
DOI arXiv Full text Patrick BilicHongwei Bran LiBjoern H. Menze grand challengeimage segmentationcomputed tomographyDice coefficient
Key2023Radiology: Artificial Intelligence2,781 citations
TotalSegmentator: Robust Segmentation of 104 Anatomic Structures in CT Images
TotalSegmentator partitions 1,204 routine CT examinations labeled for 104 anatomical structures into training, validation, and test sets. It trains nnU-Net on 1,082 examinations and reports a Dice score of 0.943 on the 65-examination internal test set. The authors study age-related changes in tissue volume and attenuation in a separate cohort of 4,004 whole-body scans.
SignificanceThe public model and annotations make it possible to compare many structures from the same CT using a common labeling scheme. The paper illustrates that use with a separate, large cohort in which the masks support quantitative measurements of organ volume and attenuation.
DOI arXiv Full text Jakob WasserthalMartin Segeroth computed tomographynnU-Netimage segmentationDice coefficientmulti-organ segmentation
Key2023IEEE Transactions on Medical Imaging724 citations
Unsupervised Medical Image Translation With Adversarial Diffusion Models
SynDiff combined cycle-based translation with adversarial diffusion to learn from unpaired medical images. The source image conditioned the synthesis and an adversarial diffusion component allowed fewer reverse steps. The authors reported improvements over tested baselines for MRI contrast translation and for translation between MRI and CT.
SignificanceSynDiff supplied a reproducible example of combining diffusion sampling with adversarial learning when aligned source and target scans are unavailable. Its public implementation and comparisons across modalities support follow-up evaluations of image fidelity and sampling cost under the same translation settings.
DOI arXiv Muzaffer ÖzbeyTolga Çukur diffusion modelgenerative adversarial networkmagnetic resonance imagingcomputed tomographycycle consistency
Key2024IEEE Transactions on Medical Imaging106 citations
MedSyn: Text-Guided Anatomy-Aware Synthesis of High-Fidelity 3-D CT Images
MedSyn trained a hierarchical diffusion model with radiology reports and anatomy channels for lung lobes, airways, and vessels. It generated coarse chest CT volumes and then increased their resolution. In a blinded assessment by ten radiologists, the generated fissures and lobe structures were rated as more anatomically plausible than those of the two generative baselines.
SignificanceThe paper gave text-conditioned chest CT synthesis a reference that tests whether generated anatomy and prompted findings are recognizable to readers. Better Tokens for Better 3D subsequently used MedSyn as a comparator when assessing text alignment and image synthesis in volumetric chest CT.
DOI arXiv Yanwu XuKayhan Batmanghelich diffusion modelsynthetic datacomputed tomographyreader study
Key2025IEEE/CVF WACV 2025169 citations
MAISI: Medical AI for Synthetic Imaging
MAISI used latent diffusion in a compressed volumetric representation to synthesize CT at specified volume dimensions and voxel spacings. An optional conditioning network generated images from anatomical or lesion masks. Adding synthetic image–mask pairs to real training data improved test Dice scores in the reported tumor segmentation experiments.
SignificanceThe study linked controllable three-dimensional synthesis to a measurable use for its paired images and labels. The implementation was released through MONAI, and the later Text2CT study used MAISI as a reference in a comparison of CT generation on data withheld from training.
DOI arXiv Full text Pengfei GuoDaguang Xu diffusion modelsynthetic datacomputed tomographyimage segmentation
Key2025Nature Communications679 citations
Towards generalist foundation model for radiology by leveraging web-scale 2D&3D medical data
RadFM represented two-dimensional images and three-dimensional studies as visual tokens that could be processed with text by the same model. The authors evaluated it on nine existing datasets and on RadBench, which covers visual question answering, report generation, and generation of diagnostic rationales.
SignificanceThe released model provided a common input interface for planar images and volumetric studies, with benchmark data for several radiology tasks. This gave later work a reproducible reference for studying how much diagnostic information a unified representation retains when it handles different image formats.
DOI arXiv Full text Chaoyi WuYanfeng WangWeidi Xie vision–language modelfoundation modelmultimodal learningcomputed tomographyradiology report generationunified representation
Key2026Nature Medicine21 citations
AI-based chest X-ray prioritization in the lung cancer diagnostic pathway: the LungIMPACT randomized controlled trial
LungIMPACT randomized by day whether to prioritize chest radiographs on the reading worklist using software results, which were available in both arms. In 93,326 analyzed primary-care radiographs, median time to CT was 53 days in each arm and median time to lung cancer diagnosis was 44 versus 46 days. Neither difference was statistically significant.
SignificanceProviding software results in both arms let the trial isolate the effect of changing the reading order. By following patients from radiography to CT and cancer diagnosis, the study supplied randomized evidence on whether worklist prioritization speeds a defined UK referral pathway.
DOI Full text Nick WoznitzaDavid R. Baldwin radiographycomputed tomographytriageprospective validation
Key2026Nature Biomedical Engineering424 citations
Generalist foundation models from a multimodal dataset for 3D computed tomography
CT-RATE paired 25,692 noncontrast chest CT volumes from 21,304 patients with their radiology reports. The authors used it to train the CT-CLIP contrastive model and evaluated abnormality classification and case retrieval. They then connected the vision encoder to a language model for scan-based question answering.
SignificanceThe work made paired volumes and reports available for studying representation learning at whole-scan scale. It also provided separate experiments for classification, retrieval, and question answering, allowing subsequent work to test how much a shared CT encoder contributes to each task.
DOI arXiv Ibrahim Ethem HamamciBjoern H. Menze computed tomographyCLIPcontrastive learningvision–language modelfoundation modelshared embedding space
Key2026Nature273 citations
Merlin: a computed tomography vision–language foundation model and dataset
Merlin learned a volumetric representation from 15,331 abdominal CT examinations, their radiology reports, and diagnosis codes. Tasks included retrieving the findings or impression section of a report from a CT volume, classifying imaging findings, and segmentation after adaptation. The external evaluation covered 44,098 exams in total from three sites and two public datasets, with different sample sizes by task.
SignificanceThe study combined routinely recorded clinical information with full 3D scans for pretraining and evaluated transfer across several independent sources. The reported task-level results give later abdominal CT models a reference for assessing how three-dimensional representations transfer.
DOI arXiv Full text Louis BlankemeierAshwin KumarAkshay S. Chaudhari computed tomographycontrastive learningmultimodal learningexternal validationunified representationshared embedding spacefoundation model
Notable2008IEEE Transactions on Medical Imaging599 citations
Four-Chamber Heart Modeling and Automatic Segmentation for 3-D Cardiac CT Volumes Using Marginal Space Learning and Steerable Features
The system first used marginal space learning to estimate the position, orientation, and scale of heart chambers, then refined their boundaries using learned image features. Its shape model included anatomical landmarks such as valves. Development and evaluation used 323 CT volumes from 137 patients.
SignificanceThe paper demonstrated a tractable way to combine pose estimation and boundary delineation in three-dimensional medical images. Its cardiac CT evaluation provides a reference example of automated localization and segmentation using learned classifiers over designed features.
DOI Yefeng Zheng image segmentationhand-crafted featuresmachine learningcomputed tomography
Notable2013Medical Image Analysis277 citations
Regression forests for efficient anatomy detection and localization in computed tomography scans
The authors cast anatomy localization in CT as continuous multivariate regression. Their forest mapped voxels to predictions of organ position and extent in a single pass and aggregated evidence across the volume. Quantitative evaluation used 400 CT scans with substantial variation.
SignificanceThe study showed how a tree ensemble could predict the anatomical region of interest in three dimensions efficiently. Its comparisons with atlas-based localization give a concrete reference for evaluating learning-based organ detection built from engineered image measurements.
DOI Antonio Criminisi random forestobject detectioncomputed tomography
Notable2019FDA 510(k) Premarket Notification K183202
Deep Learning Image Reconstruction
The 510(k) record covers the CT reconstruction option that produces TrueFidelity images. The manufacturer integrated a neural network into the scanner's raw-data reconstruction chain and evaluated image properties including noise texture. In April 2019 the FDA determined that the option was substantially equivalent to legally marketed devices.
SignificanceThe record provides primary documentation of a commercial scanner implementation and its intended use. Subsequent phantom testing measured how TrueFidelity affected noise power spectra, spatial resolution, and task-based detectability over different conditions, supplying an independent comparison with iterative reconstruction.
Full text deep-learning reconstructionFDA 510(k) clearancefiltered back-projectioncomputed tomography
Notable2025ICCV 202528 citations
Medical World Model
MeWM generates CT images of a liver tumor after transarterial chemoembolization using pretreatment imaging and treatment records. It was evaluated retrospectively on paired scans and on a held-out subset after fine-tuning on a public dataset. Three radiologists judged whether post-treatment images were real or synthetic.
SignificanceThe study makes a recorded intervention an input to CT simulation and evaluates the appearance of synthesized tumors against observed scans and radiologist judgments. Estimating how an individual would respond to an unchosen regimen requires separate evidence.
DOI arXiv Full text Jieneng Chen computed tomographydiffusion modelsynthetic dataworld model
Notable2026FDA 510(k) K252970
BriefCase-Triage: CARE Multi-triage CT Body
This software uses a locked algorithm fine-tuned from a foundation model. It processes contrast and noncontrast chest, abdominal, or pelvic CT for people aged 18 and older. It flags 11 specified suspected findings for trained readers to prioritize review of the original exam. The FDA cleared the device in January 2026.
SignificanceThe case shows how a pretrained foundation model can supply several specified triage functions in one device. The public clearance record specifies the scans, the listed findings, and the notification role, defining the scope of the application.
Full text computed tomographyUS Food and Drug Administrationfoundation modelFDA 510(k) clearance