tomography
断层成像
Imaging a single thin slice of the body without the structures in front and behind piling on top of it; from the Greek tomos, a slice. CT, MRI, PET and SPECT are all tomographic, and all escape the superposition that limits a plain radiograph.
A plain radiograph is a projection: everything along each ray is stacked together. The first remedy was mechanical. Tube and film moved in opposite directions about a pivot, so structures in the pivot's plane stayed fixed on the film and sharp while everything else smeared into blur. The French physician André Bocage patented the principle in 1921; in the 1930s Alessandro Vallebona in Italy, Bernard Ziedses des Plantes in the Netherlands and others built working machines independently.
This classical tomography only blurred the other layers; it did not remove them. CT in 1971 computed a slice from projections taken at many angles and produced the first clean cross-sections. MRI, PET and SPECT all inherited the name.
The old idea returned as tomosynthesis, which reconstructs a stack of planes from digital projections over a limited arc, chiefly for breast imaging.
- Agency for Health Technology Assessment and Tariff System (AOTMiT). The history of tomography. www.aotm.gov.pl/en/scientific-achievements-and-medical-technolog
Key works · 8
Landmark1952Journal of Laboratory and Clinical Medicine229 citations
Ultrasonic visualization of soft tissue structures of the body
The investigators recorded echoes from soft tissue interfaces and assembled the returns according to the probe position and direction to form cross-sectional pictures. They presented ultrasonic sections alongside the corresponding objects to show which boundaries and internal structures the method could depict.
SignificanceThe work established an early approach for assembling echoes from different directions into an anatomical cross section. Howry's group subsequently developed compound scanning arrangements that reduced the need to immerse the subject, making cross-sectional imaging more practical in patients.
Douglass H. HowryW. Roderic Bliss ultrasound imagingpulse–echo principleacoustic impedanceB-modetomography
Landmark1963Radiology540 citations
Image Separation Radioisotope Scanning
Kuhl and Edwards sought to separate radioactive sources at different depths that appeared superimposed on a conventional scan. They adapted ideas from section radiography, recording counts from multiple directions and superimposing the resulting signals on film. The experiment separated radioactive sources located in different sections of a test phantom.
SignificanceThe experiments established that measured emissions could form a transverse section. Later histories identify them as early demonstrations of SPECT. Rotating gamma cameras subsequently used the same multiview principle to reconstruct clinical sections with computers.
DOI David E. KuhlRoy Q. Edwards single-photon emission computed tomographytomographyprojection
Landmark1963Journal of Applied Physics1,737 citations
Representation of a Function by Its Line Integrals, with Some Radiological Applications
Cormack derived a way to recover a function on a finite region from the integrals along the lines that intersect it. He formulated applications to X-ray attenuation, positron annihilation distributions, and density estimation using the energy loss of charged particles.
SignificanceCormack formulated projection inversion as a problem in radiological physics. The 1979 Nobel Prize in Physiology or Medicine jointly recognized Cormack's theoretical contributions to reconstruction and Hounsfield's independent development of a practical computerized X-ray scanner.
DOI Allan MacLeod Cormack Radon transformattenuation coefficienttomography
Landmark1974Science192 citations
Computerized Transaxial X-ray Tomography of the Human Body
The paper described the ACTA scanner for transaxial imaging of multiple body regions. It reported experience in the brain, orbits, and skull base and discussed the potential of the wider scanner geometry for examining the chest, abdomen, spine, and other regions.
SignificanceACTA extended clinical CT beyond dedicated head examinations. Its geometry allowed cross-sectional imaging in multiple body regions, a capability that would become routine in diagnostic CT. The Smithsonian archives identify ACTA as the first whole-body diagnostic CT system.
DOI Robert S. LedleyH. L. Twigg computed tomographytomographyattenuation coefficient
Landmark1984Journal of the Optical Society of America A7,216 citations
Practical cone-beam algorithm
Feldkamp, Davis, and Kress derived an approximate three-dimensional reconstruction from two-dimensional cone-beam projections along a circular trajectory. Their method uses convolution and back-projection, reduces to fan-beam reconstruction in the central plane, and was demonstrated using projections calculated from a mathematical phantom.
SignificanceThe FDK algorithm extended filtered back-projection to practical cone-beam volumes. Its computational form became a standard analytical baseline for circular cone-beam CT, including comparisons that test artifact suppression and image recovery with limited angular sampling.
DOI L. A. FeldkampJ. W. Kress cone-beam CTfiltered back-projectiontomography
Landmark1986IEEE Transactions on Medical Imaging1,003 citations
On the Determination of Functions from Their Integral Values along Certain Manifolds
In the work first published in 1917, Radon integrated a function of two variables along straight lines in the plane. He proved that the resulting line integrals determine the original function under suitable regularity conditions and derived a formula to recover it. This record is for the published English translation.
SignificanceRadon inversion gives the mathematical basis for recovering a distribution from projections. In an ideal monoenergetic, parallel-beam CT system, the negative logarithm of the transmission fraction gives the line integrals of attenuation. This relation connects the scanner's measurements to the map it reconstructs.
Key1956Australian Journal of Physics819 citations
Strip Integration in Radio Astronomy
Bracewell analyzed how scanning a radio source with a long, narrow telescope beam integrates the true distribution along strips. He related recoverable resolution to the beam profile and gave a method for reconstructing the source distribution from scans made at different orientations.
SignificanceThe paper gives an early application of the relationship between projections and spatial frequencies. The same relationship later explained how angular measurements provide the frequency information needed to recover a cross-sectional image in medical tomography.
DOI Full text Ronald N. Bracewell Fourier transformspatial frequencyprojectiontomography
Key1964Journal of Applied Physics758 citations
Representation of a Function by Its Line Integrals, with Some Radiological Applications. II
Cormack applied his reconstruction method to gamma-ray transmission measurements taken outside a test object. The experiment compared the reconstructed attenuation distribution with the known sample structure. It demonstrated that the mathematical procedure could recover information about the interior from external measurements.
SignificanceThe experiment made the inversion a physical measurement procedure as well as a mathematical result. Cormack's Nobel lecture describes this experimental test alongside the derivation as part of the development of transmission tomography in radiology.