attenuation coefficient
衰减系数
How strongly a material weakens a beam per unit thickness, written μ and measured per centimeter. It depends on composition and photon energy; CT reconstructs μ for every voxel and reports it in Hounsfield units.
In the Beer–Lambert law, , μ is the number in the exponent. For X-rays around 70 keV, water has μ ≈ 0.19 cm⁻¹: every 3.6 cm or so of water halves the beam, a thickness called the half-value layer (). Cortical bone's μ is more than twice water's; air's is almost zero.
Dividing μ by density gives the mass attenuation coefficient μ/ρ, which depends only on elemental composition and energy and is tabulated by NIST. It generally falls as energy rises but jumps sharply at an element's K-edge, 33 keV for iodine and 37 keV for barium, which is why iodine and barium contrast agents show up so well.
Because μ depends on energy and an X-ray tube emits a broad spectrum, soft photons are absorbed first and the beam hardens with depth. In CT this produces cupping and dark streaks between bones, an artifact that dual-energy CT turns to advantage by using the energy dependence to tell materials apart.
- Hubbell JH, Seltzer SM. Tables of X-ray mass attenuation coefficients: water, liquid. NIST Standard Reference Database 126. physics.nist.gov/PhysRefData/XrayMassCoef/ComTab/water.html
Key works · 9
Landmark1963Journal of Applied Physics1,737 citations
Representation of a Function by Its Line Integrals, with Some Radiological Applications
Cormack derived a way to recover a function on a finite region from the integrals along the lines that intersect it. He formulated applications to X-ray attenuation, positron annihilation distributions, and density estimation using the energy loss of charged particles.
SignificanceCormack formulated projection inversion as a problem in radiological physics. The 1979 Nobel Prize in Physiology or Medicine jointly recognized Cormack's theoretical contributions to reconstruction and Hounsfield's independent development of a practical computerized X-ray scanner.
DOI Allan MacLeod Cormack Radon transformattenuation coefficienttomography
Landmark1973British Journal of Radiology5,075 citations
Computerized transverse axial scanning (tomography): Part 1. Description of system
Hounsfield described a head scanner that measured X-ray transmission through the same section at many angles. A computer estimated the attenuation of the individual elements of the section from those readings. The resulting images resolved differences between soft tissues with similar attenuation.
SignificanceThe EMI system put projection acquisition, numerical reconstruction, and section display into a scanner that could be used on patients. Hounsfield and Cormack shared the 1979 Nobel Prize in Physiology or Medicine for the development of computer-assisted tomography.
DOI Godfrey Newbold Hounsfield computed tomographyattenuation coefficientiterative reconstructionHounsfield unit
Landmark1974Science192 citations
Computerized Transaxial X-ray Tomography of the Human Body
The paper described the ACTA scanner for transaxial imaging of multiple body regions. It reported experience in the brain, orbits, and skull base and discussed the potential of the wider scanner geometry for examining the chest, abdomen, spine, and other regions.
SignificanceACTA extended clinical CT beyond dedicated head examinations. Its geometry allowed cross-sectional imaging in multiple body regions, a capability that would become routine in diagnostic CT. The Smithsonian archives identify ACTA as the first whole-body diagnostic CT system.
DOI Robert S. LedleyH. L. Twigg computed tomographytomographyattenuation coefficient
Landmark1976Physics in Medicine & Biology2,291 citations
Energy-selective reconstructions in X-ray computerised tomography
Alvarez and Macovski represented the energy dependence of X-ray attenuation with a small number of coefficients. They showed that coarse spectral measurements, combined with conventional tomography, could recover maps of those coefficients and separate contributions that are mixed in an energy-integrated measurement.
SignificanceThe work established the basis representation used for material decomposition in dual- and multienergy CT. Later spectral imaging research uses this representation to distinguish materials whose attenuation can appear similar on a conventional energy-integrating image.
DOI Robert E. AlvarezAlbert Macovski dual-energy CTattenuation coefficientphotoelectric effectCompton scatteringmaterial decomposition
Key1964Journal of Applied Physics758 citations
Representation of a Function by Its Line Integrals, with Some Radiological Applications. II
Cormack applied his reconstruction method to gamma-ray transmission measurements taken outside a test object. The experiment compared the reconstructed attenuation distribution with the known sample structure. It demonstrated that the mathematical procedure could recover information about the interior from external measurements.
SignificanceThe experiment made the inversion a physical measurement procedure as well as a mathematical result. Cormack's Nobel lecture describes this experimental test alongside the derivation as part of the development of transmission tomography in radiology.
Key1973British Journal of Radiology997 citations
Computerized transverse axial scanning (tomography): Part 2. Clinical application
Ambrose described how to read the sections produced by the early head scanner. Anatomical structures could be localized and characterized by attenuation, and deviations could be compared with expected pathological changes. Examples included high attenuation from blood clots and calcification in tumors.
SignificanceThe clinical paper documented that CT could localize and characterize intracranial lesions using the reconstructed tissue attenuation. The historical review in Radiology identifies the first patient examination by Ambrose and Hounsfield as the start of clinical CT.
DOI James Ambrose computed tomographyattenuation coefficient
Key1995NIST2,156 citations
Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients 1 keV to 20 MeV for Elements Z = 1 to 92 and 48 Additional Substances of Dosimetric Interest
The NIST report compiled photon mass attenuation and mass energy-absorption coefficients over energies from 1 keV to 20 MeV. The tables and graphs cover elements with atomic numbers 1 through 92 and 48 additional substances and mixtures relevant to dosimetry.
SignificanceThe compilation extended Hubbell's earlier reference tables and was subsequently made available as NIST Standard Reference Database 126. It provides consistent material data for comparing tissue attenuation, calculating photon penetration in shielding, and estimating energy deposition in dosimetry.
DOI Full text John H. HubbellStephen M. Seltzer attenuation coefficientattenuationradiation dose
Key1998Medical Physics1,081 citations
Attenuation correction for a combined 3D PET/CT scanner
The authors tested whether a registered CT image could supply an attenuation map for 511 keV PET photons. Using bone and soft-tissue phantoms and human scans, they compared conversion methods and demonstrated a hybrid mapping from CT attenuation to PET attenuation.
SignificanceThe proof of principle gave CT a quantitative function in hybrid imaging alongside anatomical localization. The first reported clinical PET/CT prototype incorporated CT-derived correction, allowing combined scans to use the CT data in place of a separate PET transmission acquisition.
DOI Paul E. KinahanDavid W. TownsendD. Sashin PET/CTattenuation coefficientgamma rayattenuation correction
Key2002IEEE Transactions on Medical Imaging757 citations
Statistical image reconstruction for polyenergetic X-ray computed tomography
The authors incorporated the source spectrum and energy-dependent attenuation into a statistical CT model. They estimated voxel densities using penalized likelihood and an ordered-subsets algorithm. In simulated measurements of objects containing bone and soft tissue, the reconstruction reduced beam-hardening artifacts.
SignificanceThe work demonstrated how statistical reconstruction can account for beam-hardening physics within the forward model. It is a reference for later model-based CT approaches that incorporate the physics of the transmission measurements into the image estimate itself.
DOI Full text Idris A. ElbakriJeffrey A. Fessler iterative reconstructionattenuation coefficientartifact