attenuation
衰减
The weakening of a beam, X-ray or ultrasound, as tissue absorbs and scatters it. Radiographs and CT images record attenuation directly; ultrasound and PET must compensate for it to image deep structures.
For X-rays, attenuation comes mainly from two interactions. At low energies the photoelectric effect dominates and depends steeply on atomic number; at higher energies Compton scattering takes over and depends mostly on electron density. Calcium in bone attenuates strongly and shows white; air in the lungs barely attenuates and shows black. The loss is exponential with thickness, as the Beer–Lambert law describes.
Ultrasound attenuates too, about 0.5 dB per centimeter per megahertz in soft tissue. A 5 MHz pulse traveling to 10 cm and back loses around 50 dB, so scanners boost late echoes with time-gain compensation, and higher-frequency probes cannot image as deep.
In PET, both 511 keV photons of a pair must escape the body. Across a 30 cm torso only about one pair in twenty makes it out intact. Without attenuation correction, now usually computed from the CT of a PET/CT scan, deep tissue would look falsely cold.
- Hubbell JH, Seltzer SM. Tables of X-ray mass attenuation coefficients: water, liquid. NIST Standard Reference Database 126. physics.nist.gov/PhysRefData/XrayMassCoef/ComTab/water.html
- Medical ultrasound. Wikipedia. en.wikipedia.org/wiki/Medical_ultrasound
Key works · 5
Landmark1896Science821 citations
On a New Kind of Rays
This English translation presents the experiments Röntgen reported in 1895. A fluorescent screen lit up near a discharge tube even when black paper blocked the tube's visible light. Objects interposed between the tube and the screen showed different degrees of transmission, and the bones in a hand cast distinct shadows.
SignificanceThe observations established the physical basis of radiography. Radiation could pass through opaque objects, and differences in transmission through their internal structures could be recorded on a screen or photographic plate. The discovery earned Röntgen the inaugural Nobel Prize in Physics in 1901.
Landmark1923Physical Review1,936 citations
A Quantum Theory of the Scattering of X-rays by Light Elements
Compton modeled the scattering of X-rays by light elements as an exchange of energy and momentum between one radiation quantum and one electron. The model predicted a wavelength shift that depended on the scattering angle, in agreement with observations including the shifted line from graphite.
SignificanceCompton received the 1927 Nobel Prize in Physics for this effect. Compton scattering accounts for much of the photon attenuation in soft tissue at diagnostic energies and also sends off-axis photons toward the detector, where they reduce radiographic contrast.
Landmark2000Journal of Nuclear Medicine1,977 citations
A Combined PET/CT Scanner for Clinical Oncology
The prototype mounted a spiral CT scanner and a rotating PET scanner on a common gantry and acquired both studies using the same patient support. The CT data supplied localization and correction information for PET. The report described scanner performance and experience imaging more than 110 patients with cancer.
SignificanceThe prototype made it possible to localize metabolic findings against anatomy acquired during the same examination. Clinical evaluation began in 1998. The first commercial PET/CT system entered clinical use in 2001 and the combined modality subsequently became common in oncology.
Full text Thomas BeyerDavid W. TownsendRonald Nutt PET/CTimage registrationattenuationordered-subsets expectation maximizationattenuation correction
Key1995NIST2,156 citations
Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients 1 keV to 20 MeV for Elements Z = 1 to 92 and 48 Additional Substances of Dosimetric Interest
The NIST report compiled photon mass attenuation and mass energy-absorption coefficients over energies from 1 keV to 20 MeV. The tables and graphs cover elements with atomic numbers 1 through 92 and 48 additional substances and mixtures relevant to dosimetry.
SignificanceThe compilation extended Hubbell's earlier reference tables and was subsequently made available as NIST Standard Reference Database 126. It provides consistent material data for comparing tissue attenuation, calculating photon penetration in shielding, and estimating energy deposition in dosimetry.
DOI Full text John H. HubbellStephen M. Seltzer attenuation coefficientattenuationradiation dose
Notable1942Zeitschrift für die gesamte Neurologie und Psychiatrie370 citations
Über die Möglichkeit, hochfrequente mechanische Schwingungen als diagnostisches Hilfsmittel zu verwerten
Dussik measured transmitted ultrasound across a grid on a formalin-fixed specimen from the right cerebral hemisphere. Figure 3 displays the variation in transmitted intensity through the specimen, which contained part of a ventricle. In a separate experiment, he detected a signal after sending ultrasound from one temple to the other through a human head.
SignificanceThe study was an early investigation of intracranial ultrasound transmission. Dussik published images from later work in 1947, interpreting the patterns as ventricular anatomy. In 1952, Güttner and colleagues showed experimentally that attenuation by the skull could account for those patterns.
DOI Full text Karl Theo Dussik ultrasound imagingacoustic impedanceattenuation