mammography

乳腺X线摄影

Low-energy X-ray imaging of the compressed breast, designed to show small masses and specks of calcium a fraction of a millimeter across. It is the principal method of breast-cancer screening and one of the first places computer-aided reading reached the clinic.

The breast is almost all soft tissue, and fat, glandular tissue and tumor differ only slightly in attenuation. Mammography units therefore run at low tube voltages, usually below 35 kV, often with a molybdenum anode whose characteristic X-rays at 17.5 and 19.6 keV fall where soft-tissue contrast is best. A paddle compresses the breast to cut scatter and dose and to spread overlapping tissue apart.

In 1913 the German surgeon Albert Salomon radiographed some 3,000 mastectomy specimens and saw microcalcifications beside tumors. Around 1960 Robert Egan in Houston made the technique reproducible in patients, and in the mid-1960s the French company CGR introduced the Senographe, the first dedicated mammography unit.

A digital screening exam delivers about 0.28 mSv. Dense breasts can hide cancers, which motivated tomosynthesis. R2's ImageChecker, approved by the FDA in 1998, was the first commercial mammography computer-aided detection & diagnosis system, a role deep-learning models are now taking over.

Sources
  1. Quality assurance in mammography: an overview. Eur J Radiol / PMC review, 2023. pmc.ncbi.nlm.nih.gov/articles/PMC10528604/
  2. Egan RL. Experience with mammography in a tumor institution: evaluation of 1,000 studies. Radiology. 1960;75(6):894–900. doi.org/10.1148/75.6.894
  3. RadiologyInfo.org (RSNA/ACR). Radiation dose in X-ray and CT exams. www.radiologyinfo.org/en/info/safety-xray

Key works · 27

Landmark1951American Journal of Roentgenology and Radium Therapy189 citations

Diagnosis of Tumors of the Breast by Simple Roentgenography: Calcifications in Carcinomas

Raúl Leborgne

Leborgne described the appearance and distribution of fine calcifications in breast carcinomas, comparing radiographs with pathological findings. His technique paired an overview radiograph with a small-field exposure over a suspected lesion. The reduced field limited scatter and let the reader inspect finer detail.

SignificanceThe paper helped establish a radiographic feature that could be interpreted against breast pathology. The morphology and distribution of microcalcifications became part of routine mammographic interpretation and can draw attention to lesions that have yet to produce a palpable mass.

Landmark1985The Lancet1,956 citations

Reduction in mortality from breast cancer after mass screening with mammography: Randomised Trial from the Breast Cancer Screening Working Group of the Swedish National Board of Health and Welfare

L. Tabár, A. Gad … C. J. G. Fagerberg

The Swedish Two-County Trial randomized communities to receive or forgo invitations to periodic single-view mammography. Among 134,867 women aged 40 to 74 at entry, the group invited for screening had 31% lower breast cancer mortality and a 25% lower rate of stage II or more advanced breast cancers through 1984.

SignificanceThe two-county trial provided randomized evidence based on breast cancer mortality as well as tumor detection. The International Agency for Research on Cancer used this trial in its assessment of whether population mammography screening could reduce deaths from breast cancer.

Landmark1987Medical Physics391 citations

Image feature analysis and computer-aided diagnosis in digital radiography. I. Automated detection of microcalcifications in mammography

Heang-Ping Chan, Kunio Doi … Peter M. Jokich

The detector subtracted a signal-suppressed image from a signal-enhanced image to reduce structured mammographic background, then selected candidates using physical characteristics of microcalcifications. With simulated clusters placed on normal backgrounds, it detected roughly 80% of clusters at about one false-positive cluster per image.

SignificanceThe study established a candidate-generation and feature-screening procedure with a measurable sensitivity and false-positive tradeoff. The same research program then used controlled reader studies to determine whether providing such candidate marks improved radiologists' recognition of microcalcification clusters.

Landmark1997Radiology846 citations

Digital Tomosynthesis in Breast Imaging

L. T. Niklason, B. T. Christian … B. H. Opsahl-Ong

The investigators acquired multiple low-dose projections on a full-field digital mammography system as the X-ray source moved through an arc. They reconstructed sections from a single arc and tested them on phantoms and mastectomy specimens. Readers generally preferred the sections for lesion visualization at a dose comparable to single-view mammography.

SignificanceThe work demonstrated that a digital breast system could acquire the limited-angle data needed to reduce tissue superposition. The same acquisition principle became the basis of clinical breast tomosynthesis and was subsequently evaluated against conventional digital mammography in screening studies.

Landmark1998U.S. Food and Drug Administration

M1000 IMAGECHECKER

R2 Technology, Inc.

The FDA granted premarket approval to the M1000 ImageChecker in June 1998. The device marked suspicious areas on routine screening mammograms for a radiologist to review after completing an initial interpretation, defining a specific order for the aided reading workflow.

SignificanceThe approval established a regulatory precedent for using computer-generated marks during mammographic screening. Subsequent investigations in community screening centers, registry studies, and equivalence trials evaluated how assisted reading affected detection and recall under different workflows.

Landmark2020Nature4,409 citations

International evaluation of an AI system for breast cancer screening

Scott Mayer McKinney, Marcin Sieniek … Hutan Ashrafian

The authors evaluated a mammography screening model retrospectively in UK and US cohorts and ran a separate reader study with six radiologists. They reported false-positive and false-negative performance by cohort and simulated how the model might interact with the UK double-reading workflow.

SignificanceThe use of separate national cohorts and a reader study provided evidence for evaluating mammography models under different screening conditions. The later methodological addendum made more of the optimization and augmentation setup available for assessing reproducibility of the retrospective results.

Landmark2026The Lancet134 citations

Interval cancer, sensitivity, and specificity comparing AI-supported mammography screening with standard double reading without AI in the MASAI study: a randomised, controlled, non-inferiority, single-blinded, population-based, screening-accuracy trial

Jessie Gommers, Veronica Hernström … Annie Hjelmgren

In the MASAI follow-up, interval cancer rates were 1.55 and 1.76 per 1,000 participants with software-assisted and standard double reading, respectively. The rate ratio was 0.88 (95% confidence interval 0.65–1.18), with the upper bound below the prespecified noninferiority margin of 1.20. Sensitivity was higher in the assisted group, and specificity was 98.5% in both groups.

SignificanceThe prespecified endpoint extended the trial's assessment beyond cancer detection on the screening day. Random assignment and follow-up make the interval-cancer findings interpretable together with the same trial's earlier evidence on screen-detected cases and reader workload.

Key1990Investigative Radiology409 citations

Improvement in Radiologists' Detection of Clustered Microcalcifications on Mammograms: The Potential of Computer-Aided Diagnosis

Heang-Ping Chan, Kunio Doi … Kwok Leung Lam

The authors tested whether displaying computer-generated marks improved radiologists' detection of clustered microcalcifications. They compared aided and unaided readings in a controlled setting intended to resemble rapid screening interpretation, finding significantly better detection accuracy with the computerized aid by ROC analysis.

SignificanceThe study evaluated the performance of radiologists using the detector outputs. The history published by Medical Physics identifies it as an early controlled comparison of aided and unaided readings, an approach that preceded evaluations of recall and cancer detection in practice.

Key2001Radiology839 citations

Screening Mammography with Computer-aided Detection: Prospective Study of 12,860 Patients in a Community Breast Center

Timothy W. Freer, Michael J. Ulissey

The community breast center prospectively recorded 12,860 screening examinations. Radiologists first interpreted each examination unaided and then reviewed marked locations. The study reported more cancers detected and a higher recall rate after the second step, with the positive predictive value of biopsy unchanged.

SignificanceThis study supplied prospective evidence on adding marks to a community screening workflow and quantified the associated increase in recall. Subsequent large registry studies used different designs to assess whether such changes generalized across facilities and readers.

Key2005New England Journal of Medicine2,187 citations

Diagnostic Performance of Digital versus Film Mammography for Breast-Cancer Screening

Etta D. Pisano, Constantine Gatsonis … Suddhasatta Acharyya

In DMIST, 49,528 asymptomatic women underwent both digital and film screening mammography. Readers interpreted the images independently, and complete data were available for 42,760 women. Receiver operating characteristic analysis showed similar overall accuracy, with higher accuracy for digital mammography among women under 50, women with dense breasts, and premenopausal or perimenopausal women.

SignificanceThe paired design established a direct comparison during the transition from film to digital screening. The National Cancer Institute uses DMIST when summarizing the evidence on digital mammography, including the observed differences by age and breast density.

Key2007Computerized Medical Imaging and Graphics2,221 citations

Computer-aided diagnosis in medical imaging: Historical review, current status and future potential

Kunio Doi

The review traced computer-aided diagnosis from early radiographic classification to prototype systems for mammography, chest radiography, and CT. It examined candidate detection, characterization, and reader studies, emphasizing the use of computer output as a second opinion within radiologists' interpretation workflow.

SignificanceThe review established a historical reference for the distinct roles of algorithm performance, reader assistance, and clinical evaluation. The later Medical Physics history similarly organizes research around how machine outputs are developed and tested in breast and chest imaging.

Key2007New England Journal of Medicine699 citations

Influence of Computer-Aided Detection on Performance of Screening Mammography

Joshua J. Fenton, Stephen H. Taplin … Carl D'Orsi

The registry study assessed 429,345 screening mammograms from 43 facilities. At the seven facilities that implemented computer-aided detection during the study, specificity fell from 90.2% to 87.2% and the biopsy rate increased by 19.7%. The rise in sensitivity was statistically nonsignificant.

SignificanceThe study measured how assisted reading was associated with specificity and downstream biopsies after adoption in routine care. The subsequent analysis of digital screening revisited performance under a different imaging workflow, extending work beyond controlled reader experiments.

Key2008New England Journal of Medicine351 citations

Single Reading with Computer-Aided Detection for Screening Mammography

Fiona J. Gilbert, Susan M. Astley … Jonathan James

A multicenter equivalence trial in England compared double reading of screening film mammograms with single reading aided by computer detection. In paired comparisons, the workflows detected 87.7% and 87.2% of cancers, respectively. The assisted single-reading workflow had a slightly higher recall rate.

SignificanceThe trial tested a concrete workflow question about replacing a second human read in a film-screening program. It measured recall alongside cancer detection, providing comparative evidence on staffing and screening outcomes under specified reading conditions.

Key2014JAMA927 citations

Breast Cancer Screening Using Tomosynthesis in Combination With Digital Mammography

Sarah M. Friedewald, Elizabeth A. Rafferty … Julianne S. Greenberg

The investigators retrospectively compared 454,850 examinations across 13 centers before and after adding tomosynthesis to digital mammography. In adjusted estimates per 1,000 screens, recall declined from 107 to 91 and cancer detection increased from 4.2 to 5.4 after the addition.

SignificanceThe study estimated changes in recall and detection across a range of screening practices after clinical adoption. It was included in the Agency for Healthcare Research and Quality evidence review and supplied multicenter data on outcomes later evaluated in prospective trials.

Key2015JAMA Internal Medicine815 citations

Diagnostic Accuracy of Digital Screening Mammography With and Without Computer-Aided Detection

Constance D. Lehman, Robert D. Wellman … for the Breast Cancer Surveillance Consortium

The study compared digital mammograms read with and without detection assistance across 66 community facilities. Registry linkage supplied cancer outcomes over the following year. In roughly 626,000 examinations, the study found no overall accuracy improvement with computer assistance across its performance measures.

SignificanceThis large registry analysis extended clinical evaluation of conventional detection assistance to digital screening. The study included hundreds of readers and accounted for clustering by radiologist, providing evidence on how detector marks performed in routine community practice.

Key2017Scientific Data1,113 citations

A curated mammography data set for use in computer-aided detection and diagnosis research

Rebecca Sawyer Lee, Francisco Gimenez … Daniel L. Rubin

CBIS-DDSM curated a subset of a digitized screen-film mammography collection. The release provided decompressed images, updated mass segmentations and bounding boxes, and pathology information. It included 753 calcification cases and 891 mass cases with documented training and test partitions for evaluation.

SignificanceDocumenting case selection, lesion annotations, and evaluation splits makes it possible to compare mammographic detection and classification methods on a common collection. TCIA maintains the release and provides images and metadata tables that identify the training and test subsets.

Key2022The Lancet Digital Health878 citations

AI recognition of patient race in medical imaging: a modelling study

Judy Wawira Gichoya, Imon Banerjee … Li-Ching Chen

The authors train models to predict self-reported race from medical images and test them across institutions and several modalities. They assess proposed proxy variables and perturb the images to investigate the source of the signal. The tested individual proxies did not account for the model's discrimination.

SignificanceThe finding shows why withholding demographic input fields does not prevent a model from accessing population-associated signals in the image itself. Cross-modality and external testing made the paper a reference for auditing fairness in medical image models.

Key2022The Lancet Oncology139 citations

Digital breast tomosynthesis plus synthesised mammography versus digital screening mammography for the detection of invasive breast cancer (TOSYMA): a multicentre, open-label, randomised, controlled, superiority trial

Walter Heindel, Stefanie Weigel … TOSYMA Screening Trial Study Group

Across 17 German screening units, TOSYMA randomly assigned women to either digital breast tomosynthesis with synthesized two-dimensional mammography or standard digital mammography. Invasive cancers were detected at rates of 7.1 and 4.8 per 1,000 screened, respectively, in the evaluable groups.

SignificanceTOSYMA provided randomized evidence for higher invasive cancer detection with a configuration that obtains the two-dimensional image from the same acquisition. It therefore evaluated a screening protocol that can be implemented without a separate conventional two-dimensional exposure.

Key2023The Lancet Digital Health487 citations

Artificial intelligence for breast cancer detection in screening mammography in Sweden: a prospective, population-based, paired-reader, non-inferiority study

Karin Dembrower, Alessio Crippa … and the ScreenTrustCAD Trial Consortium

ScreenTrustCAD enrolled 55,581 women in a Swedish screening program and compared two reading strategies on the same mammograms. One radiologist and software reading independently detected 261 cancers within three months, compared with 250 detected by two radiologists, meeting the prespecified noninferiority criterion.

SignificanceThe paired design tested software as a replacement for one independent reader within a routine screening program. The trial hospital subsequently put this reading arrangement into clinical use, and a follow-up implementation study documented the risks and mitigation measures identified by staff.

Key2023The Lancet Oncology807 citations

Artificial intelligence-supported screen reading versus standard double reading in the Mammography Screening with Artificial Intelligence trial (MASAI): a clinical safety analysis of a randomised, controlled, non-inferiority, single-blinded, screening accuracy study

Kristina Lång, Viktoria Josefsson … Hanna Sartor

MASAI randomly assigned screening participants to software-supported mammography reading or standard double reading. The early clinical safety analysis involved about 80,000 participants. Detection rates were 6.1 and 5.1 per 1,000 screened, respectively, and the supported workflow reduced screen-reading workload by 44.3%.

SignificanceThis interim safety analysis counted screen readings alongside cancer detections in an organized screening program. Later reports from the same randomized trial examined screen-detected cancers in the full cohort and evaluated the primary interval-cancer endpoint after follow-up.

Key2023Radiology527 citations

Automation Bias in Mammography: The Impact of Artificial Intelligence BI-RADS Suggestions on Reader Performance

Thomas Dratsch, Xue Chen … Michael Püsken

Twenty-seven radiologists graded fifty mammograms with BI-RADS suggestions attributed to an automated system. Some suggestions were deliberately incorrect. Correct grading declined across all experience groups when the suggestions were wrong, and less experienced readers followed certain incorrect upward suggestions more often.

SignificanceBy controlling whether the suggested category was correct, the study could directly measure how readers responded when assistance misled them. It provided a reader-study design for evaluating automation bias across experience levels in mammography interpretation.

Key2025Nature Medicine364 citations

Nationwide real-world implementation of AI for cancer detection in population-based mammography screening

Nora Eisemann, Stefan Bunk … Timo Gomille

The PRAIM implementation study compared supported and standard double reading in an organized mammography screening program. It included 463,094 women at twelve German sites. Cancer detection was 6.7 versus 5.7 per 1,000 screened, and recall in the supported group met the study's noninferiority criterion.

SignificanceThe study documents large-scale use inside an established double-reading program. Radiologists chose whether to use the system, so the observational comparison complements randomized evidence by describing implementation in a different screening organization and reporting outcomes from routine practice.

Key2025The Lancet Digital Health263 citations

Screening performance and characteristics of breast cancer detected in the Mammography Screening with Artificial Intelligence trial (MASAI): a randomised, controlled, parallel-group, non-inferiority, single-blinded, screening accuracy study

Veronica Hernström, Viktoria Josefsson … Solveig Hofvind

The full screening cohort of MASAI was analyzed for cancers detected at the screening visit. Detection was 6.4 versus 5.0 per 1,000 participants for supported versus standard reading. The paper describes features of detected invasive cancers and in-situ disease and reports recall and false positives.

SignificanceThis analysis complements the early safety report by characterizing the additional cancers found at screening and reporting reading workload with the full cohort. The interval-cancer publication addresses a separate prespecified question requiring follow-up after the screening visit.

Key2026Nature Medicine16 citations

AI-based triage and decision support in mammography and digital tomosynthesis for breast cancer screening: a paired, noninferiority trial

Esperanza Elías-Cabot, Sara Romero-Martín … Marina Álvarez-Benito

The prospective paired trial enrolled 31,301 women and compared standard double reading with a workflow that marked low-risk exams normal and sent the rest to software-assisted double reading. Radiologist workload fell by 63.6%, cancer detection rose from 6.3 to 7.3 per 1,000, and recall increased, failing its noninferiority criterion.

SignificanceThe trial quantified how removing low-risk exams from the reading queue affected workload, detection, and recall within one program. Reading reductions were similar for digital mammography and digital breast tomosynthesis, while detection and recall increased in the digital mammography subgroup. This gives readers modality-specific evidence for workflow design.

Key2026The Lancet Oncology1 citations

Invasive interval breast cancer rates after digital breast tomosynthesis plus synthesised mammography versus digital mammography screening (TOSYMA): 24-month follow-up of the multicentre, open-label, randomised, controlled, superiority trial

Stefanie Weigel, Hans-Werner Hense … Hiltraud Kajüter

This TOSYMA follow-up linked women with a negative screening result to cancer registries. At 24 months, the tomosynthesis plus synthesized mammography arm had 14.2 invasive interval cancers per 10,000 women, compared with 18.6 with digital mammography. The adjusted odds ratio was 0.76, with a 95% confidence interval of 0.55 to 1.06.

SignificanceThe follow-up reports the second prespecified primary endpoint of the same randomized trial that found higher invasive cancer detection at screening in 2022. The confidence interval leaves uncertainty about whether higher detection at screening translates into fewer invasive interval cancers over the next two years.

Notable1994Medical Physics190 citations

Computerized detection of clustered microcalcifications in digital mammograms using a shift‐invariant artificial neural network

Wei Zhang, Kunio Doi … Robert A. Schmidt

The authors trained a locally connected network with shared weights to reclassify microcalcification candidates. In holdout experiments on 168 candidate regions from 34 mammograms, the method removed approximately 55% of the false-positive regions without eliminating any true-positive regions in that sample.

SignificanceThe study is an early medical imaging example of local shared weights trained by backpropagation. Its placement after a candidate generator illustrates how a learned classifier could address a specific source of false-positive detections within an existing screening pipeline.

Notable1996IEEE Transactions on Medical Imaging471 citations

Classification of mass and normal breast tissue: a convolution neural network classifier with spatial domain and texture images

B. Sahiner, Heang-Ping Chan … M.M. Goodsitt

The authors used a convolutional network to classify manually selected mammogram regions as masses or normal tissue. They compared how downsampled intensities and images of local texture features worked as inputs. In a study of 168 confirmed mass regions and 504 normal regions, the best test AUC was 0.87.

SignificanceThe study documented early convolutional classification of mammographic masses and tested how engineered texture measurements could be used as network inputs. Later work on large-scale mammographic lesion detection cited the study as an early application of convolutional networks to mammography.