sensitivity and specificity
敏感度与特异度
Two basic measures of any diagnostic test: sensitivity is the share of sick people it catches, specificity the share of healthy people it correctly clears. When the decision threshold is moved, one rises as the other falls.
Arrange results in a 2×2 table of true positives (TP), false negatives (FN), true negatives (TN), and false positives (FP). Sensitivity ; specificity . The biostatistician Jacob Yerushalmy introduced the pair to medical diagnosis in 1947, while evaluating chest X-ray methods for tuberculosis screening.
Neither depends on how common the disease is, which is both a strength and a source of misinterpretation. In breast screening, where roughly 5 in 1,000 women have cancer, a specificity of 95% still recalls about 50 healthy women per 1,000, so most positive results are false alarms.
An AI paper that reports one sensitivity and one specificity has chosen one threshold; another threshold gives another pair, and the full trade-off is the ROC curve. The pivotal trial of IDx-DR pre-specified both endpoints (sensitivity above 85%, specificity above 82.5%) and reached 87.2% and 90.7%, the evidence behind the first authorization of autonomous AI.
- Yerushalmy J. Statistical problems in assessing methods of medical diagnosis, with special reference to X-ray techniques. Public Health Rep. 1947;62(40):1432–1449. doi.org/10.2307/4586294
- Abràmoff MD, Lavin PT, Birch M, Shah N, Folk JC. Pivotal trial of an autonomous AI-based diagnostic system for detection of diabetic retinopathy in primary care offices. npj Digit Med. 2018;1:39. doi.org/10.1038/s41746-018-0040-6
Key works · 21
Landmark1982Radiology24,806 citations
The meaning and use of the area under a receiver operating characteristic (ROC) curve.
The paper interpreted the area under an ROC curve from graded readings or continuous scores as the probability that a randomly selected affected case ranks above an unaffected case. Relating the probability to the Wilcoxon statistic yielded practical approximations for standard errors and study sample sizes.
SignificanceThe interpretation gave reader studies a common meaning for a summary across rating thresholds and a way to plan precision. Later clinical evaluation guidance places that summary alongside threshold-specific performance, which is needed when a scoring system will be used at a defined operating point.
DOI James A. HanleyBarbara J. McNeil ROC curve and AUCsensitivity and specificityreader study
Landmark2011New England Journal of Medicine12,304 citations
Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening
At 33 centers, the National Lung Screening Trial randomly assigned high-risk participants to three annual rounds of low-dose CT or single-view chest radiography. Lung cancer mortality was 20% lower in the CT group. That group also had more positive screening results, most of which were false positives.
SignificanceThe trial showed that the evaluation of low-dose CT screening could measure lung cancer deaths along with detection and false-positive results. The US Preventive Services Task Force included NLST in its evidence for lung cancer screening recommendations.
DOI Full text Denise R. AberleChristine D. Berg low-dose CTradiographysensitivity and specificity
Landmark2015BMJ4,584 citations
STARD 2015: an updated list of essential items for reporting diagnostic accuracy studies
STARD 2015 updated a reporting checklist for diagnostic accuracy studies using evidence about sources of bias and variation. The thirty items cover participant selection, the index test, the reference standard, and how data were analyzed and reported, so readers can appraise the study's estimated accuracy.
SignificanceSTARD established a common reporting framework for diagnostic accuracy studies and is indexed by EQUATOR for that study design. The 2025 extension for algorithm-based tests used the 2015 checklist as its starting point and added considerations for model-based evaluations.
DOI Full text Patrick M. BossuytJérémie F. Cohen sensitivity and specificityground truthexternal validation
Landmark2016JAMA9,321 citations
Development and Validation of a Deep Learning Algorithm for Detection of Diabetic Retinopathy in Retinal Fundus Photographs
The authors trained a convolutional network on 128,175 graded fundus photographs and tested it for referable diabetic retinopathy on EyePACS-1 and Messidor-2. The reference was the majority judgment of ophthalmologists. The model achieved AUCs of 0.991 and 0.990 on the two retrospective validation datasets.
SignificanceThis study provided a large retrospective benchmark for automated screening from fundus photographs. A follow-up study examined the implications of its reference-standard choice, comparing majority grading with adjudication by retina specialists and quantifying the resulting differences in evaluation.
DOI Varun GulshanLily PengDale R. Webster fundus photographyROC curve and AUCsensitivity and specificity
Landmark2018npj Digital Medicine2,097 citations
Pivotal trial of an autonomous AI-based diagnostic system for detection of diabetic retinopathy in primary care offices
The pivotal trial enrolled 900 participants with diabetes at ten primary-care sites and compared the device with reading-center grading of widefield stereoscopic photography and OCT. For detection of more-than-mild diabetic retinopathy, the study reported a sensitivity of 87.2% and a specificity of 90.7%.
SignificanceThe trial supported the FDA's 2018 De Novo authorization of IDx-DR for an autonomous screening decision in primary care. The FDA summary reports its own performance analysis and imageability assessment, providing an example of the evidence used for this intended use.
DOI Full text Michael D. AbràmoffJames C. Folk fundus photographysensitivity and specificityFDA De Novo classificationground truthprospective validation
Landmark2026The Lancet134 citations
Interval cancer, sensitivity, and specificity comparing AI-supported mammography screening with standard double reading without AI in the MASAI study: a randomised, controlled, non-inferiority, single-blinded, population-based, screening-accuracy trial
In the MASAI follow-up, interval cancer rates were 1.55 and 1.76 per 1,000 participants with software-assisted and standard double reading, respectively. The rate ratio was 0.88 (95% confidence interval 0.65–1.18), with the upper bound below the prespecified noninferiority margin of 1.20. Sensitivity was higher in the assisted group, and specificity was 98.5% in both groups.
SignificanceThe prespecified endpoint extended the trial's assessment beyond cancer detection on the screening day. Random assignment and follow-up make the interval-cancer findings interpretable together with the same trial's earlier evidence on screen-detected cases and reader workload.
DOI Jessie GommersKristina Lång mammographysensitivity and specificitytriageinterval cancernoninferiority trialprospective validation
Key1995The Journal of Trauma453 citations
A Prospective Study of Surgeon-Performed Ultrasound as the Primary Adjuvant Modality for Injured Patient Assessment
In a prospective series of 371 injured patients, trained surgeons used ultrasound to look for intraperitoneal blood or pericardial fluid. Ultrasound detected 53 of 65 patients with significant injuries, and the investigators reported a sensitivity of 81.5% and specificity of 99.7%.
SignificanceThe series provided prospective evidence for surgeon-performed ultrasound in the initial assessment of trauma. Subsequent clinical practice reports documented the focused assessment with sonography for trauma as a rapid way to look for fluid that required further assessment.
DOI Grace S. RozyckiHoward R. Champion point-of-care ultrasoundultrasound imagingsensitivity and specificity
Key2001Radiology839 citations
Screening Mammography with Computer-aided Detection: Prospective Study of 12,860 Patients in a Community Breast Center
The community breast center prospectively recorded 12,860 screening examinations. Radiologists first interpreted each examination unaided and then reviewed marked locations. The study reported more cancers detected and a higher recall rate after the second step, with the positive predictive value of biopsy unchanged.
SignificanceThis study supplied prospective evidence on adding marks to a community screening workflow and quantified the associated increase in recall. Subsequent large registry studies used different designs to assess whether such changes generalized across facilities and readers.
DOI Timothy W. FreerMichael J. Ulissey computer-aided detection & diagnosismammographysensitivity and specificityprospective validation
Key2003The New England Journal of Medicine2,123 citations
Computed Tomographic Virtual Colonoscopy to Screen for Colorectal Neoplasia in Asymptomatic Adults
The researchers examined 1,233 asymptomatic adults with virtual and optical colonoscopy on the same day. CT readers initially searched a three-dimensional endoluminal display for polyps. With final optical findings after segmental unblinding as the reference, CT colonography had a per-patient sensitivity of 93.8% for adenomatous polyps at least 10 mm in diameter.
SignificanceThe study provided screening data for CT colonography using a primary three-dimensional reading method in asymptomatic adults. Later multicenter validation also studied performance by lesion size, providing independent evidence for assessing the technique's use in screening.
DOI Perry J. PickhardtWilliam R. Schindler CT colonographycomputed tomographyendoscopysensitivity and specificity
Key2004IEEE Transactions on Medical Imaging2,365 citations
Simultaneous Truth and Performance Level Estimation (STAPLE): An Algorithm for the Validation of Image Segmentation
STAPLE starts with several human or algorithm-generated segmentations. It uses expectation maximization to estimate the probability of a reference label at each voxel while estimating sensitivity and specificity for each input segmentation. The authors demonstrated the approach on synthetic and clinical images.
SignificanceThe approach made it possible to estimate rater reliability and a consensus reference within the same model. ITK provides an implementation that produces a probability map from multiple segmentations, allowing the procedure to be reused in validation and label-fusion workflows.
DOI Full text Simon K. WarfieldWilliam M. Wells III image segmentationground truthinter-observer variabilitysensitivity and specificity
Key2007New England Journal of Medicine699 citations
Influence of Computer-Aided Detection on Performance of Screening Mammography
The registry study assessed 429,345 screening mammograms from 43 facilities. At the seven facilities that implemented computer-aided detection during the study, specificity fell from 90.2% to 87.2% and the biopsy rate increased by 19.7%. The rise in sensitivity was statistically nonsignificant.
SignificanceThe study measured how assisted reading was associated with specificity and downstream biopsies after adoption in routine care. The subsequent analysis of digital screening revisited performance under a different imaging workflow, extending work beyond controlled reader experiments.
DOI Full text Joshua J. FentonJoann G. Elmore computer-aided detection & diagnosismammographysensitivity and specificity
Key2008New England Journal of Medicine351 citations
Single Reading with Computer-Aided Detection for Screening Mammography
A multicenter equivalence trial in England compared double reading of screening film mammograms with single reading aided by computer detection. In paired comparisons, the workflows detected 87.7% and 87.2% of cancers, respectively. The assisted single-reading workflow had a slightly higher recall rate.
SignificanceThe trial tested a concrete workflow question about replacing a second human read in a film-screening program. It measured recall alongside cancer detection, providing comparative evidence on staffing and screening outcomes under specified reading conditions.
DOI Fiona J. GilbertS.W. Duffy computer-aided detection & diagnosismammographysensitivity and specificityreader study
Key2015JAMA Internal Medicine815 citations
Diagnostic Accuracy of Digital Screening Mammography With and Without Computer-Aided Detection
The study compared digital mammograms read with and without detection assistance across 66 community facilities. Registry linkage supplied cancer outcomes over the following year. In roughly 626,000 examinations, the study found no overall accuracy improvement with computer assistance across its performance measures.
SignificanceThis large registry analysis extended clinical evaluation of conventional detection assistance to digital screening. The study included hundreds of readers and accounted for clustering by radiologist, providing evidence on how detector marks performed in routine community practice.
DOI Full text Constance Dobbins LehmanDiana L. Miglioretti computer-aided detection & diagnosismammographysensitivity and specificity
Key2017JAMA2,835 citations
Development and Validation of a Deep Learning System for Diabetic Retinopathy and Related Eye Diseases Using Retinal Images From Multiethnic Populations With Diabetes
The authors trained a retinal image system for diabetic retinopathy, possible glaucoma, and age-related macular degeneration. The primary validation set came from Singapore's screening program. Ten additional cohorts with diverse ethnic composition were used to evaluate discrimination for referable diabetic retinopathy.
SignificanceThe study established a multi-cohort reference for testing whether retinal classifiers travel between screening populations. Reporting the main validation dataset separately from external cohorts made it possible to inspect variability across programs instead of relying on a pooled performance estimate.
DOI Daniel Shu Wei TingTien Yin Wong fundus photographyexternal validationsensitivity and specificity
Key2019JAMA Dermatology456 citations
Association Between Surgical Skin Markings in Dermoscopic Images and Diagnostic Performance of a Deep Learning Convolutional Neural Network for Melanoma Recognition
The authors tested a melanoma classifier on unmarked, marked, and cropped dermoscopic images of 130 lesions. They photographed benign nevi with marks on the skin and digitally added marks to archived melanoma images. Specificity fell from 84.1% to 45.8% with marks and was 97.2% in the cropped images.
SignificanceChanging the mark while retaining the same lesion isolated an acquisition-related cue from the appearance of the lesion. The paired design gives direct evidence that a preprocessing or photography decision can shift the predictions of a dermatology classifier authorized for the European market.
DOI Julia K. WinklerHolger A. Haenssle dermoscopyshortcut learningsensitivity and specificity
Key2022The Lancet Digital Health301 citations
Real-time diabetic retinopathy screening by deep learning in a multisite national screening programme: a prospective interventional cohort study
A prospective cohort at nine Thai primary-care sites used a system to interpret fundus photographs and generate referrals in real time, with retina specialists reviewing every image for safety. Against adjudicated grades, sensitivity for vision-threatening diabetic retinopathy was 91.4% and specificity was 95.4%.
SignificanceThe cohort added evidence from a national screening program and routine image acquisition to earlier retrospective work. Recording performance alongside ungradable examinations and referral recommendations made it possible to assess the screening program's operational feasibility as well as its diagnostic accuracy.
DOI Paisan RuamviboonsukRory SayresDale R. Webster fundus photographyexternal validationsensitivity and specificityreference standard adjudicationprospective validation
Key2023JAMA Dermatology114 citations
Assessment of Diagnostic Performance of Dermatologists Cooperating With a Convolutional Neural Network in a Prospective Clinical Study: Human With Machine
Dermatologists at two centers prospectively assessed 228 suspicious melanocytic lesions and reconsidered their decisions after seeing a convolutional network score. Reference diagnoses came from histopathology or, for nonexcised lesions, follow-up and expert consensus. Sensitivity rose from 84.2% to 100%, and specificity from 72.1% to 83.7%.
SignificanceRecording clinical assessments and management plans before and after score disclosure linked dermoscopy model performance to decisions made during the visit. Proposed excisions of benign nevi fell from 104 to 84, giving prospective evidence on how assistance could change the management of suspicious lesions.
DOI Full text Julia K. WinklerHolger A. Haenssle dermoscopysensitivity and specificityreference standard adjudicationprospective validation
Key2023Nature Communications162 citations
Validation of MSIntuit as an AI-based pre-screening tool for MSI detection from colorectal cancer histology slides
The authors trained MSIntuit on The Cancer Genome Atlas and performed blinded validation in an independent cohort of 600 consecutive patients with colorectal cancer. They digitized slides on two scanners to measure the sensitivity, specificity, and cross-scanner agreement of histology-based microsatellite instability prescreening.
SignificanceThe blinded study quantified how a histology-based prediction model performed as a prescreen on independent clinical material. Sensitivity of 0.96 to 0.98 and specificity of 0.46 to 0.47 across the two scanners define the tradeoff for triaging samples to confirmatory testing.
DOI Full text Charlie SaillardMagali Svrcek histopathologywhole-slide imageexternal validationsensitivity and specificity
Key2025Nature Medicine364 citations
Nationwide real-world implementation of AI for cancer detection in population-based mammography screening
The PRAIM implementation study compared supported and standard double reading in an organized mammography screening program. It included 463,094 women at twelve German sites. Cancer detection was 6.7 versus 5.7 per 1,000 screened, and recall in the supported group met the study's noninferiority criterion.
SignificanceThe study documents large-scale use inside an established double-reading program. Radiologists chose whether to use the system, so the observational comparison complements randomized evidence by describing implementation in a different screening organization and reporting outcomes from routine practice.
DOI Full text Nora EisemannStefan BunkAlexander Katalinic mammographyexternal validationsensitivity and specificityprospective validation
Key2025The Lancet Digital Health263 citations
Screening performance and characteristics of breast cancer detected in the Mammography Screening with Artificial Intelligence trial (MASAI): a randomised, controlled, parallel-group, non-inferiority, single-blinded, screening accuracy study
The full screening cohort of MASAI was analyzed for cancers detected at the screening visit. Detection was 6.4 versus 5.0 per 1,000 participants for supported versus standard reading. The paper describes features of detected invasive cancers and in-situ disease and reports recall and false positives.
SignificanceThis analysis complements the early safety report by characterizing the additional cancers found at screening and reporting reading workload with the full cohort. The interval-cancer publication addresses a separate prespecified question requiring follow-up after the screening visit.
DOI Veronica HernströmKristina Lång mammographysensitivity and specificitytriageprospective validation
Key2025Nature Medicine630 citations
The STARD-AI reporting guideline for diagnostic accuracy studies using artificial intelligence
The STARD extension was developed by international consensus for diagnostic accuracy studies using algorithmic tests. It expands reporting on the evaluated system and the data used to assess it, with attention to provenance, reference standards, performance evaluation, and the potential for bias in intended use.
SignificanceThe extension embeds information about algorithmic tests and their evaluation data within an established diagnostic accuracy framework. It gives imaging accuracy studies a common reporting structure for examining the tested system, case selection, and the meaning of reported performance.
DOI Full text Viknesh SounderajahHutan Ashrafian sensitivity and specificityground truthbias and fairness