Key2022The Lancet Digital Health301 citations
Real-time diabetic retinopathy screening by deep learning in a multisite national screening programme: a prospective interventional cohort study
A prospective cohort at nine Thai primary-care sites used a system to interpret fundus photographs and generate referrals in real time, with retina specialists reviewing every image for safety. Against adjudicated grades, sensitivity for vision-threatening diabetic retinopathy was 91.4% and specificity was 95.4%.
SignificanceThe cohort added evidence from a national screening program and routine image acquisition to earlier retrospective work. Recording performance alongside ungradable examinations and referral recommendations made it possible to assess the screening program's operational feasibility as well as its diagnostic accuracy.