MG·LB · Key works

Diagnostic deep-learning studies and clinical validation

In the exhibits10.4 Four landmark studies, 2016–201711.1 The first authorized AI diagnosis and triage software11.6 COVID-19 models and external validation

Landmark2016JAMA9,321 citations

Development and Validation of a Deep Learning Algorithm for Detection of Diabetic Retinopathy in Retinal Fundus Photographs

Varun Gulshan, Lily Peng, Marc Coram, Martin C. Stumpe, Derek Wu, Arunachalam Narayanaswamy

The authors trained a convolutional network on 128,175 graded fundus photographs and tested it for referable diabetic retinopathy on EyePACS-1 and Messidor-2. The reference was the majority judgment of ophthalmologists. The model achieved AUCs of 0.991 and 0.990 on the two retrospective validation datasets.

SignificanceThis study provided a large retrospective benchmark for automated screening from fundus photographs. A follow-up study examined the implications of its reference-standard choice, comparing majority grading with adjudication by retina specialists and quantifying the resulting differences in evaluation.

Followed byVoets 2019

Landmark2017CVPR 20176,028 citations

ChestX-Ray8: Hospital-Scale Chest X-Ray Database and Benchmarks on Weakly-Supervised Classification and Localization of Common Thorax Diseases

Xiaosong Wang, Yifan Peng, Le Lu, Zhiyong Lu, Mohammadhadi Bagheri, Ronald M. Summers

The paper introduced ChestX-ray8, containing 108,948 frontal radiographs from 32,717 patients with eight report-derived disease labels. The authors demonstrated weakly supervised classification and localization on the collection. The later ChestX-ray14 release extended the set of labels available for these images.

SignificanceThe hospital-scale release made report-derived supervision widely available for chest radiograph research. Later cross-institutional studies used the NIH collection to test transportability and documented that performance estimates varied with the source of training data and the hospital used for evaluation.

Key2017arXiv5,269 citations

CheXNet: Radiologist-Level Pneumonia Detection on Chest X-Rays with Deep Learning

Pranav Rajpurkar, Jeremy Irvin, Kaylie Zhu, Brandon Yang, Hershel Mehta, Tony Duan

CheXNet uses a 121-layer convolutional network trained on ChestX-ray14 to detect pneumonia in frontal chest radiographs. On a set of 420 images annotated by four radiologists, the authors report a higher pneumonia F1 score than the average reader obtained under the study conditions.

SignificanceThe preprint supplied an early reader comparison for a chest radiograph classifier trained with large-scale report-derived labels. The later CheXNeXt study changed the reader and reference-standard setup and reported separate comparisons for a wider set of chest findings.

Builds onHuang 2017

Key2017Radiology2,098 citations

Deep Learning at Chest Radiography: Automated Classification of Pulmonary Tuberculosis by Using Convolutional Neural Networks

Paras Lakhani, Baskaran Sundaram

The authors applied AlexNet and GoogLeNet to pulmonary tuberculosis classification on chest radiographs, comparing pretraining, augmentation, and ensembling. An ensemble of the two architectures achieved an AUC of 0.99 on the held-out test split, and the study examined expert review of discordant cases.

SignificanceThe study supplied an early radiology benchmark for transferring general-purpose convolutional networks to chest radiograph tuberculosis detection. Its experiments also compared stand-alone predictions with an expert arbitration workflow, anticipating the distinction between algorithm evaluation and assisted interpretation.

Builds onKrizhevsky 2012, Szegedy 2015

Landmark2017Nature18,648 citations

Dermatologist-level classification of skin cancer with deep neural networks

Andre Esteva, Brett Kuprel, Roberto A. Novoa, Justin Ko, Susan M. Swetter … Sebastian Thrun

A network initialized on ImageNet was fine-tuned on 129,450 clinical images. The team compared its predictions with those of 21 dermatologists on biopsy-confirmed images in two tasks, including melanoma versus benign nevi, and reported comparable discrimination under the specified image-reading conditions.

SignificanceThe reader comparison became a widely cited reference for image-based skin lesion classification. The later DDI study carried the biopsy-confirmed evaluation approach into a more diverse setting and showed how performance of dermatology classifiers can vary by skin tone and disease frequency.

Key2017JAMA2,835 citations

Development and Validation of a Deep Learning System for Diabetic Retinopathy and Related Eye Diseases Using Retinal Images From Multiethnic Populations With Diabetes

Daniel Shu Wei Ting, Carol Yim-Lui Cheung, Gilbert Lim, Gavin Siew Wei Tan, Nguyen D. Quang, Alfred Gan

The authors trained a retinal image system for diabetic retinopathy, possible glaucoma, and age-related macular degeneration. The primary validation set came from Singapore's screening program. Ten additional cohorts with diverse ethnic composition were used to evaluate discrimination for referable diabetic retinopathy.

SignificanceThe study established a multi-cohort reference for testing whether retinal classifiers travel between screening populations. Reporting the main validation dataset separately from external cohorts made it possible to inspect variability across programs instead of relying on a pooled performance estimate.

Landmark2017JAMA4,056 citations

Diagnostic Assessment of Deep Learning Algorithms for Detection of Lymph Node Metastases in Women With Breast Cancer

Babak Ehteshami Bejnordi, Mitko Veta, Paul Johannes van Diest, Bram van Ginneken, Nico Karssemeijer … CAMELYON16 Consortium

CAMELYON16 compared algorithms for finding breast cancer metastases in lymph-node whole-slide images. On 129 held-out slides, the best algorithm achieved a slide-level AUC of 0.994. The comparison included eleven time-constrained pathologists and a separate pathologist who read without a time limit.

SignificanceThe evaluation provided a shared task for whole-slide metastasis detection and showed how the reader comparison depended on the conditions of interpretation. CAMELYON17 extended the benchmark from finding metastases on individual slides to estimating nodal status at the patient level.

Landmark2018GigaScience537 citations

1399 H&E-stained sentinel lymph node sections of breast cancer patients: the CAMELYON dataset

Geert Litjens, Peter Bandi, Babak Ehteshami Bejnordi, Oscar Geessink, Maschenka Balkenhol, Peter Bult

The release assembled 1,399 whole-slide images of sentinel lymph node sections from five centers. The images had slide-level labels spanning negative cases and several categories of metastasis. A subset also had detailed lesion outlines, allowing patch- or region-level evaluation in addition to slide classification.

SignificanceThe release made annotated digital pathology from multiple hospitals available for metastasis research. The CAMELYON challenges used the collection to support evaluation of lesion detection and patient-level staging, linking performance at several levels of the pathology workflow.

Landmark2018Nature Medicine3,120 citations

Clinically applicable deep learning for diagnosis and referral in retinal disease

Jeffrey De Fauw, Joseph R. Ledsam, Bernardino Romera-Paredes, Stanislav Nikolov, Nenad Tomasev, Sam Blackwell

The system segments tissues in three-dimensional retinal OCT and uses the tissue maps to predict diagnoses and referral urgency. The retrospective evaluation compares referral decisions with expert judgments. For a second scanner type in the same hospital setting, the authors retrained the segmentation network and tested referral performance with the classifier unchanged.

SignificanceThe intermediate tissue maps made it possible to examine what retinal structures the system detected before assigning a referral decision. By testing a change of scanner at this interface, the study also gave a concrete example of examining transfer across OCT devices.

Key2018PLOS Medicine1,844 citations

Deep learning for chest radiograph diagnosis: A retrospective comparison of the CheXNeXt algorithm to practicing radiologists

Pranav Rajpurkar, Jeremy Irvin, Robyn L. Ball, Kaylie Zhu, Brandon Yang, Hershel Mehta

CheXNeXt was evaluated on 420 frontal chest radiographs for 14 findings, using majority judgments from three cardiothoracic radiologists as the reference. In the retrospective comparison with nine additional readers, the authors classified performance as comparable for ten findings, higher for one, and lower for three.

SignificanceThe journal study expanded the earlier pneumonia comparison into a per-finding reader evaluation with a separately defined reference panel. Its breakdown makes clear which findings drove the overall agreement and provides a bounded reference for later work on external clinical populations.

Key2018Ophthalmology667 citations

Grader Variability and the Importance of Reference Standards for Evaluating Machine Learning Models for Diabetic Retinopathy

Jonathan Krause, Varun Gulshan, Ehsan Rahimy, Peter Karth, Kasumi Widner … Dale R. Webster

The study compares diabetic retinopathy grades assigned independently by ophthalmologists with a reference established by adjudicating disagreements among retina specialists. The authors then measure how the choice between majority grading and adjudication changes reported performance for both machine learning and individual readers.

SignificanceThe comparison made the construction of the reference standard an explicit part of diagnostic evaluation. The subsequent prospective screening cohort in Thailand also assessed retinal-image classification and referral recommendations against an adjudicated reference supplied by fellowship-trained retina specialists.

Landmark2018npj Digital Medicine2,097 citations

Pivotal trial of an autonomous AI-based diagnostic system for detection of diabetic retinopathy in primary care offices

Michael D. Abràmoff, Philip T. Lavin, Michele Birch, Nilay Shah, James C. Folk

The pivotal trial enrolled 900 participants with diabetes at ten primary-care sites and compared the device with reading-center grading of widefield stereoscopic photography and OCT. For detection of more-than-mild diabetic retinopathy, the study reported a sensitivity of 87.2% and a specificity of 90.7%.

SignificanceThe trial supported the FDA's 2018 De Novo authorization of IDx-DR for an autonomous screening decision in primary care. The FDA summary reports its own performance analysis and imageability assessment, providing an example of the evidence used for this intended use.

Landmark2018Scientific Data5,286 citations

The HAM10000 dataset, a large collection of multi-source dermatoscopic images of common pigmented skin lesions

Philipp Tschandl, Cliff Rosendahl, Harald Kittler

The authors harmonized dermatoscopic images from several sources and released 10,015 images of common pigmented lesions. They documented the diagnostic references used for the categories. More than half of lesions had pathology confirmation, with others supported by follow-up, expert consensus, or confocal microscopy.

SignificanceHAM10000 made multisource training data with a shared diagnostic taxonomy accessible through ISIC. The subsequent lesion classification benchmark used these images as training material, allowing different methods to be developed with a common set of categories and examples.

Landmark2018PLOS Medicine2,399 citations

Variable generalization performance of a deep learning model to detect pneumonia in chest radiographs: A cross-sectional study

John R. Zech, Marcus A. Badgeley, Manway Liu, Anthony B. Costa, Joseph J. Titano, Eric Karl Oermann

The authors assessed pneumonia classifiers across three healthcare systems. Ranking by hospital alone reached an AUC of 0.861 in a pooled two-hospital dataset. The model trained on that pool achieved 0.931 on its internal test set and 0.815 at a third institution.

SignificanceThe study quantified a source of distribution shift by combining hospital identification experiments with testing at another institution. Subsequent work on COVID-19 radiographs cites it as evidence that a model can obtain high scores from acquisition-related correlates of disease prevalence.

Key2019JAMA Dermatology456 citations

Association Between Surgical Skin Markings in Dermoscopic Images and Diagnostic Performance of a Deep Learning Convolutional Neural Network for Melanoma Recognition

Julia K. Winkler, Christine Fink, Ferdinand Toberer, Alexander Enk, Teresa Deinlein, Rainer Hofmann-Wellenhof

The authors tested a melanoma classifier on unmarked, marked, and cropped dermoscopic images of 130 lesions. They photographed benign nevi with marks on the skin and digitally added marks to archived melanoma images. Specificity fell from 84.1% to 45.8% with marks and was 97.2% in the cropped images.

SignificanceChanging the mark while retaining the same lesion isolated an acquisition-related cue from the appearance of the lesion. The paired design gives direct evidence that a preprocessing or photography decision can shift the predictions of a dermatology classifier authorized for the European market.

Landmark2019AAAI 20192,359 citations

CheXpert: A Large Chest Radiograph Dataset with Uncertainty Labels and Expert Comparison

Jeremy Irvin, Pranav Rajpurkar, Michael Ko, Yifan Yu, Silviana Ciurea-Ilcus, Chris Chute

CheXpert contained 224,316 radiographs from 65,240 patients, with 14 observations derived from reports and explicit uncertainty labels. The authors compared several different ways of using uncertain observations during training and evaluated the resulting models on studies independently annotated by radiologists.

SignificanceExplicit uncertainty labels gave researchers a shared way to evaluate strategies for handling equivocal report findings during training. The expert-labeled evaluation made it possible to compare interpretations through a benchmark with a reference distinct from the automatically assigned training labels.

Landmark2019Nature Medicine3,479 citations

Clinical-grade computational pathology using weakly supervised deep learning on whole slide images

Gabriele Campanella, Matthew G. Hanna, Luke Geneslaw, Allen Miraflor, Vitor Werneck Krauss Silva, Klaus J. Busam

Using diagnoses from reports as supervision, the authors trained slide classifiers without manually tracing lesions. They evaluated the system on 44,732 routine whole-slide images from 15,187 patients. Areas under the ROC curve exceeded 0.98 for prostate cancer, basal cell carcinoma, and breast cancer nodal metastases.

SignificanceThe study established routine pathology archives as a practical source of large-scale supervision for whole-slide classification. It was a reference point for CLAM, which examined how to retain the slide-label training setup while reducing the quantity of labeled material required.

Landmark2019Nature Medicine2,876 citations

End-to-end lung cancer screening with three-dimensional deep learning on low-dose chest computed tomography

Diego Ardila, Atilla P. Kiraly, Sujeeth Bharadwaj, Bokyung Choi, Joshua J. Reicher, Lily Peng

A volumetric model estimates lung cancer risk from low-dose chest CT, incorporating a prior scan when available. It achieved an AUC of 0.944 on held-out National Lung Screening Trial cases. The study also evaluated 1,139 independent clinical cases and compared readers with and without prior imaging.

SignificanceThe study provided an early end-to-end benchmark for lung screening from volumetric CT and made the availability of prior imaging explicit in the reader comparison. Sybil cites this work and extends the question to multiyear risk estimation from a single scan.

Landmark2019Scientific Data3,108 citations

MIMIC-CXR, a de-identified publicly available database of chest radiographs with free-text reports

Alistair E. W. Johnson, Tom J. Pollard, Seth J. Berkowitz, Nathaniel R. Greenbaum, Matthew P. Lungren … Steven Horng

The paper documented the de-identification and organization of MIMIC-CXR. It linked 377,110 chest radiographs from 227,835 studies to contemporaneous free-text reports. A study could include multiple radiographic views, allowing analysis to use the images together with the corresponding clinical interpretation.

SignificancePaired images and reports made a common clinical source available for work on report-derived labeling, report generation, and image–text modeling. Credentialed access through PhysioNet enables reuse under a common data-use agreement and preserves the documented study-to-image relationships.

Key2019Gut1,021 citations

Real-time automatic detection system increases colonoscopic polyp and adenoma detection rates: a prospective randomised controlled study

Pu Wang, Tyler M. Berzin, Jeremy Romek Glissen Brown, Shishira Bharadwaj, Aymeric Becq, Xun Xiao

This prospective randomized trial compared standard colonoscopy with a workflow that issued real-time prompts for suspected polyps. Among 1,058 participants, adenoma detection was 29.1% in the assisted arm and 20.3% in the control arm, with the increase concentrated in diminutive adenomas.

SignificanceThe trial evaluated how live detection prompts affected a procedural endpoint during colonoscopy. Reporting the contribution of small and larger adenomas also clarified which lesions accounted for the overall change, an important distinction when interpreting the clinical value of extra detections.

Notable2019PLOS ONE374 citations

Reproduction study using public data of: Development and validation of a deep learning algorithm for detection of diabetic retinopathy in retinal fundus photographs

Mike Voets, Kajsa Møllersen, Lars Ailo Bongo

The authors reimplemented the published diabetic retinopathy method using public EyePACS images and a different distribution of Messidor-2. They obtained AUCs of 0.951 and 0.853. The original performance was not reproduced under changes in training images, grading, and test-set distribution.

SignificanceThe reproduction makes dataset versions and grading procedures part of the comparison. It quantifies how much the result can change in a public-data reimplementation and shows why an architecture description alone cannot reproduce a diagnostic evaluation.

Builds onGulshan 2016

Key2020CHI 2020866 citations

A Human-Centered Evaluation of a Deep Learning System Deployed in Clinics for the Detection of Diabetic Retinopathy

Emma Beede, Elizabeth Baylor, Fred Hersch, Anna Iurchenko, Lauren Wilcox … Laura M. Vardoulakis

The authors observed retinal screening at eleven Thai clinics and interviewed people involved in the workflow. They documented how imaging conditions, the system's image-quality requirements, and local scheduling affected what nurses could do and how patients received results or referrals in practice.

SignificanceThe observations documented practical effects missing from retrospective accuracy estimates, such as extra steps following an image-quality rejection. The subsequent prospective Thai cohort complements this qualitative work with quantitative data on actual screening performance and referrals.

Key2020BMJ1,464 citations

Artificial intelligence versus clinicians: systematic review of design, reporting standards, and claims of deep learning studies

Myura Nagendran, Yang Chen, Christopher A. Lovejoy, Anthony C. Gordon, Matthieu Komorowski, Hugh Harvey

The systematic review examined study design, reporting, and risk of bias for comparisons of diagnostic deep learning with expert clinicians. Of 81 nonrandomized studies, nine were prospective and six tested systems in clinical settings. The authors also searched for registered randomized trials.

SignificanceThe review quantified the gap between retrospective expert comparisons and tests of clinical use, and examined whether published claims were supported by study design. Its separation of study designs provides a reference for assessing how subsequent imaging evaluation has changed.

Key2020Academic Radiology303 citations

Exploring Large-scale Public Medical Image Datasets

Luke Oakden-Rayner

The author inspected images in ChestX-ray14 and MURA to assess how their labels corresponded to visible findings. Labels for several chest findings had lower positive predictive value than documentation suggested. In MURA, some positive labels tracked features such as the presence of hardware.

SignificanceThe study moved dataset label quality from a documented assumption to something that could be checked by sampling imagery. Its findings about report-derived chest labels and musculoskeletal abnormality labels show why each benchmark needs a task-specific interpretation.

Landmark2020Nature Medicine1,138 citations

Guidelines for clinical trial protocols for interventions involving artificial intelligence: the SPIRIT-AI extension

Samantha Cruz Rivera, Xiaoxuan Liu, An-Wen Chan, Alastair K. Denniston, Melanie J. Calvert, on behalf of the SPIRIT-AI and CONSORT-AI Working Group

The SPIRIT extension used literature review, Delphi consultation, and consensus to specify how trial protocols should describe an algorithmic intervention. The additional items cover system version, input and output handling, the setting and skills required for use, and the planned approach to analyzing errors.

SignificanceThe guideline brought the operating conditions and planned analysis of algorithm errors into prospectively reported protocols. EQUATOR lists it under trial protocols alongside a companion CONSORT extension for reporting completed studies, providing aligned checks at two stages of a trial.

Key2020ACM CHIL 2020723 citations

Hidden Stratification Causes Clinically Meaningful Failures in Machine Learning for Medical Imaging

Luke Oakden-Rayner, Jared Dunnmon, Gustavo Carneiro, Christopher Ré

The authors examined clinically important subsets that had been combined under broad dataset labels. They compared several ways of finding performance differences, including expert-defined subclasses and error review. Experiments on simulated and medical imaging data identified gaps associated with low prevalence, noisy labels, subtle findings, and spurious correlates.

SignificanceThe paper made variation within a nominal diagnostic class an explicit evaluation problem. A later study of a commercial chest radiograph model assessed pneumothorax performance by clinical strata such as the presence of a drain, extending the investigation to a different system.

Landmark2020Nature4,409 citations

International evaluation of an AI system for breast cancer screening

Scott Mayer McKinney, Marcin Sieniek, Varun Godbole, Jonathan Godwin, Natasha Antropova, Hutan Ashrafian

The authors evaluated a mammography screening model retrospectively in UK and US cohorts and ran a separate reader study with six radiologists. They reported false-positive and false-negative performance by cohort and simulated how the model might interact with the UK double-reading workflow.

SignificanceThe use of separate national cohorts and a reader study provided evidence for evaluating mammography models under different screening conditions. The later methodological addendum made more of the optimization and augmentation setup available for assessing reproducibility of the retrospective results.

Key2020Medical Image Analysis1,021 citations

PadChest: A large chest x-ray image dataset with multi-label annotated reports

Aurelia Bustos, Antonio Pertusa, Jose-Maria Salinas, Maria de la Iglesia-Vayá

PadChest assembled chest radiographs and corresponding Spanish-language reports from a hospital archive. The project used labels for radiographic findings, anatomical locations, and possible diagnoses. Trained annotators labeled a subset of reports, and a model assigned labels to the remaining reports.

SignificanceThe collection broadened the reporting language, geographic source, and label vocabulary represented in public chest radiography data. Later studies have used it alongside other datasets to test whether models retain performance when evaluated on an external institution's examinations.

Key2020BMJ3,711 citations

Prediction models for diagnosis and prognosis of covid-19: systematic review and critical appraisal

Laure Wynants, Ben Van Calster, Gary S. Collins, Richard D. Riley, Georg Heinze, Ewoud Schuit

This living systematic review collected models for COVID-19 diagnosis and prognosis and evaluated their populations, outcomes, validation, and risk of bias. It covered clinical predictors alongside imaging models and updated the model inventory and methodological assessments as more studies became available.

SignificanceThe successive updates document how evidence about pandemic prediction models changed over time. Applying the same risk-of-bias review to different kinds of models distinguished strong reported development scores from cases with independent validation and more reliable study methods.

Landmark2020Nature Medicine1,949 citations

Reporting guidelines for clinical trial reports for interventions involving artificial intelligence: the CONSORT-AI extension

Xiaoxuan Liu, Samantha Cruz Rivera, David Moher, Melanie J. Calvert, Alastair K. Denniston, on behalf of the SPIRIT-AI and CONSORT-AI Working Group

The CONSORT extension added fourteen reporting items to the core randomized trial checklist for studies involving an algorithmic intervention. The items describe the system version, suitability and handling of inputs, how users interacted with outputs in the clinical workflow, and analysis of errors.

SignificanceThe checklist standardizes how reports describe the algorithmic component of a trial, enabling comparison of the tested versions and workflows. Clinical evaluation guidance for medical diagnosis lists the extension among the relevant reporting frameworks for large trials of these interventions.

Key2020American Journal of Roentgenology188 citations

Using Deep Learning to Accelerate Knee MRI at 3 T: Results of an Interchangeability Study

Michael P. Recht, Jure Zbontar, Daniel K. Sodickson, Florian Knoll, Nafissa Yakubova, Anuroop Sriram

Six readers compared standard 3 T knee MRI with images reconstructed from retrospectively undersampled data. Undersampling simulated a 3.49-fold speedup over fully sampled acquisition and a 1.88-fold speedup over standard parallel acquisition. The images met the study's interchangeability criterion for internal derangement of the knee, and readers favored the accelerated images for image quality.

SignificanceThe study evaluated whether reconstructed scans could substitute for standard scans on a specified diagnostic task. Its reader-based interchangeability design supplied clinical evidence that complemented fastMRI's image similarity metrics and defined the setting in which the replacement was tested.

Key2021Nature Machine Intelligence986 citations

AI for radiographic COVID-19 detection selects shortcuts over signal

Alex J. DeGrave, Joseph D. Janizek, Su-In Lee

The authors trained and audited COVID-19 chest radiograph classifiers using external testing, saliency maps, and image perturbations. Some decisions depended on acquisition-related cues such as laterality markers and image borders. Models that scored well on internal data could lose performance at an external institution.

SignificanceThe study combined several tests of shortcut reliance and showed why internal accuracy or a heat map alone cannot establish that a model recognizes pathology. It provided a case-level audit design that changes a suspected cue and then measures the prediction again.

Landmark2021Nature Machine Intelligence1,458 citations

Common pitfalls and recommendations for using machine learning to detect and prognosticate for COVID-19 using chest radiographs and CT scans

Michael Roberts, Derek Driggs, Matthew Thorpe, Julian Gilbey, Michael Yeung, Stephan Ursprung

The authors screened 2,212 records on COVID-19 models using chest radiographs or CT between January and October 2020 and included 62 studies after quality screening. They examined dataset provenance, leakage, bias, and external validation and found no included model with evidence of potential clinical use.

SignificanceThis highly cited review tied recurring problems in early pandemic imaging research to checkable aspects of study design. It explained how duplicate images, mismatched control groups, and absent external testing can coexist with apparently strong diagnostic scores.

Key2021Nature Medicine1,196 citations

Federated learning for predicting clinical outcomes in patients with COVID-19

Ittai Dayan, Holger R. Roth, Aoxiao Zhong, Ahmed Harouni, Amilcare Gentili, Anas Z. Abidin

EXAM used federated training across 20 institutions to predict future oxygen requirements in symptomatic patients with COVID-19 from chest radiographs, vital signs, and laboratory data. The reported average AUC exceeded 0.92 at 24 and 72 hours, and average AUC across sites improved relative to models trained on individual institutions' data.

SignificanceEXAM demonstrated a federated collaboration using heterogeneous imaging and clinical variables, with testing at an independent institution. A later methodological review of federated learning in healthcare identifies it alongside brain tumor studies as early evidence for evaluating generalization across institutions.

Key2021Nature Medicine1,387 citations

Underdiagnosis bias of artificial intelligence algorithms applied to chest radiographs in under-served patient populations

Laleh Seyyed-Kalantari, Haoran Zhang, Matthew B. A. McDermott, Irene Y. Chen, Marzyeh Ghassemi

The authors trained chest radiograph classifiers on three large datasets and a multisource combination, then measured how often models assigned a normal label to patients with findings. Their analysis compared demographic groups and found that disparities could be greater for intersecting underserved groups.

SignificanceBy measuring underdiagnosis as a distinct outcome, the study showed how aggregate performance can conceal the distribution of missed findings. Its cross-dataset and intersectional comparisons provide a concrete reference for testing how these errors are distributed across populations.

Key2022The Lancet Digital Health878 citations

AI recognition of patient race in medical imaging: a modelling study

Judy Wawira Gichoya, Imon Banerjee, Ananth Reddy Bhimireddy, John L. Burns, Leo Anthony Celi, Li-Ching Chen

The authors train models to predict self-reported race from medical images and test them across institutions and several modalities. They assess proposed proxy variables and perturb the images to investigate the source of the signal. The tested individual proxies did not account for the model's discrimination.

SignificanceThe finding shows why withholding demographic input fields does not prevent a model from accessing population-associated signals in the image itself. Cross-modality and external testing made the paper a reference for auditing fairness in medical image models.

Key2022Science Advances837 citations

Disparities in dermatology AI performance on a diverse, curated clinical image set

Roxana Daneshjou, Kailas Vodrahalli, Roberto A. Novoa, Melissa Jenkins, Weixin Liang, Veronica Rotemberg

The authors assembled the biopsy-confirmed Diverse Dermatology Images collection and used it to assess classifiers and dermatologist visual labels across skin tones. Models performed worse on darker skin and uncommon diseases. Fine-tuning on the more diverse collection reduced the measured disparity between skin tones.

SignificanceThe public image collection and pathology reference enabled subgroup evaluation without relying on the visual labels used to train many existing models. Testing both classifiers and human visual labels gave subsequent work a way to examine label quality alongside performance disparities.

Key2022Nature Communications161 citations

Estimating diagnostic uncertainty in artificial intelligence assisted pathology using conformal prediction

Henrik Olsson, Kimmo Kartasalo, Nita Mulliqi, Marco Capuccini, Pekka Ruusuvuori, Hemamali Samaratunga

The study applies conformal sets to cancer detection and grading from prostate biopsy slides. On test data from the same laboratory and scanner, some predictions are flagged for review. The authors also examine cases from external scanners and cases with atypical prostate tissue.

SignificanceThe study documents how prediction sets could be used to defer prostate pathology cases to human review and reports the relative frequency of errors and deferrals. Testing scanner and laboratory differences makes the dependence on acquisition conditions visible.

Key2022Nature Biomedical Engineering736 citations

Expert-level detection of pathologies from unannotated chest X-ray images via self-supervised learning

Ekin Tiu, Ellie Talius, Pujan Patel, Curtis P. Langlotz, Andrew Y. Ng, Pranav Rajpurkar

CheXzero learned jointly from chest radiographs and their reports and used positive and negative text prompts to classify findings without task-specific labels at training time. In an external dataset, it outperformed one fully supervised comparator on three of eight findings.

SignificanceThe study operationalized CLIP-style classification for multilabel imaging findings using positive and negative prompts and external evaluation. Subsequent experiments on zero-shot chest radiograph recognition have used CheXzero as a comparison when testing more detailed disease descriptions and image-text alignment.

Builds onRadford 2021, Zhang 2022

Key2022The Lancet Digital Health301 citations

Real-time diabetic retinopathy screening by deep learning in a multisite national screening programme: a prospective interventional cohort study

Paisan Ruamviboonsuk, Richa Tiwari, Rory Sayres, Variya Nganthavee, Kornwipa Hemarat, Apinpat Kongprayoon

A prospective cohort at nine Thai primary-care sites used a system to interpret fundus photographs and generate referrals in real time, with retina specialists reviewing every image for safety. Against adjudicated grades, sensitivity for vision-threatening diabetic retinopathy was 91.4% and specificity was 95.4%.

SignificanceThe cohort added evidence from a national screening program and routine image acquisition to earlier retrospective work. Recording performance alongside ungradable examinations and referral recommendations made it possible to assess the screening program's operational feasibility as well as its diagnostic accuracy.

Key2022BMJ953 citations

Reporting guideline for the early stage clinical evaluation of decision support systems driven by artificial intelligence: DECIDE-AI

Baptiste Vasey, Myura Nagendran, Bruce Campbell, David A. Clifton, Gary S. Collins, Spiros Denaxas

The DECIDE group developed reporting guidance for early clinical evaluations of decision support systems through a modified Delphi process and stakeholder consensus. The checklist has seventeen system-specific items and ten generic items. It addresses workflow, errors, safety, and human factors in small-scale use.

SignificanceThe checklist gives investigators a way to document the first clinical use of a system, including changes to its operation and the circumstances in which errors occur. It addresses a stage between offline evaluation and large randomized trials.

Key2022Scientific Data662 citations

VinDr-CXR: An open dataset of chest X-rays with radiologist’s annotations

Ha Q. Nguyen, Khanh Lam, Linh T. Le, Hieu H. Pham, Dat Q. Tran, Dung B. Nguyen

VinDr-CXR released 18,000 chest radiographs from two Vietnamese hospitals with manual annotations. Labels included boxes for 22 local findings and six image-level categories. Three radiologists annotated each training image independently, while boxes and labels for the test set used a five-reader consensus.

SignificanceReleased localization labels provide a reference for evaluating where a detector marks findings on the image. The documented institutions, annotation process, and training and test partitions also make VinDr-CXR useful for assessment alongside collections originating elsewhere.

Notable2023JAMA558 citations

Accuracy of a Generative Artificial Intelligence Model in a Complex Diagnostic Challenge

Zahir Kanjee, Byron Crowe, Adam Rodman

The authors presented published diagnostic challenge cases to GPT-4 before revealing the expert discussion or answer, asking for a ranked differential diagnosis. The model included the correct diagnosis in its list for 64% of cases and ranked it first for 39% of cases.

SignificanceThe study tested open-ended differential diagnosis and distinguished including a diagnosis somewhere in a list from ranking it first. This offered an early comparison point for subsequent case-based experiments that assessed diagnostic reasoning and support for clinicians.

Key2023The Lancet Digital Health487 citations

Artificial intelligence for breast cancer detection in screening mammography in Sweden: a prospective, population-based, paired-reader, non-inferiority study

Karin Dembrower, Alessio Crippa, Eugenia Colón, Martin Eklund, Fredrik Strand, and the ScreenTrustCAD Trial Consortium

ScreenTrustCAD enrolled 55,581 women in a Swedish screening program and compared two reading strategies on the same mammograms. One radiologist and software reading independently detected 261 cancers within three months, compared with 250 detected by two radiologists, meeting the prespecified noninferiority criterion.

SignificanceThe paired design tested software as a replacement for one independent reader within a routine screening program. The trial hospital subsequently put this reading arrangement into clinical use, and a follow-up implementation study documented the risks and mitigation measures identified by staff.

Key2023The Lancet Oncology807 citations

Artificial intelligence-supported screen reading versus standard double reading in the Mammography Screening with Artificial Intelligence trial (MASAI): a clinical safety analysis of a randomised, controlled, non-inferiority, single-blinded, screening accuracy study

Kristina Lång, Viktoria Josefsson, Anna-Maria Larsson, Stefan Larsson, Charlotte Högberg, Hanna Sartor

MASAI randomly assigned screening participants to software-supported mammography reading or standard double reading. The early clinical safety analysis involved about 80,000 participants. Detection rates were 6.1 and 5.1 per 1,000 screened, respectively, and the supported workflow reduced screen-reading workload by 44.3%.

SignificanceThis interim safety analysis counted screen readings alongside cancer detections in an organized screening program. Later reports from the same randomized trial examined screen-detected cancers in the full cohort and evaluated the primary interval-cancer endpoint after follow-up.

Key2023JAMA Dermatology114 citations

Assessment of Diagnostic Performance of Dermatologists Cooperating With a Convolutional Neural Network in a Prospective Clinical Study: Human With Machine

Julia K. Winkler, Andreas Blum, Katharina Kommoss, Alexander Enk, Ferdinand Toberer … Holger A. Haenssle

Dermatologists at two centers prospectively assessed 228 suspicious melanocytic lesions and reconsidered their decisions after seeing a convolutional network score. Reference diagnoses came from histopathology or, for nonexcised lesions, follow-up and expert consensus. Sensitivity rose from 84.2% to 100%, and specificity from 72.1% to 83.7%.

SignificanceRecording clinical assessments and management plans before and after score disclosure linked dermoscopy model performance to decisions made during the visit. Proposed excisions of benign nevi fell from 104 to 84, giving prospective evidence on how assistance could change the management of suspicious lesions.

Key2023JAMA Neurology130 citations

Automated Large Vessel Occlusion Detection Software and Thrombectomy Treatment Times: A Cluster Randomized Clinical Trial

Juan Carlos Martinez-Gutierrez, Youngran Kim, Sergio Salazar-Marioni, Muhammad Bilal Tariq, Rania Abdelkhaleq, Arash Niktabe

Four stroke centers introduced large-vessel occlusion detection on CT angiograms and secure group messaging in stages. The order was randomized for three centers, with the academic center assigned to go last in advance. The intervention shortened the time from hospital arrival to arterial puncture for thrombectomy. The trial also assessed 90-day disability in an exploratory analysis.

SignificanceThe trial moved beyond specialist notification, an endpoint in the FDA's early ContaCT decision, to an observed treatment workflow measure. It provides a randomized evaluation of imaging triage in hospitals, with the intervention combining detection software and team communication.

Key2023Radiology527 citations

Automation Bias in Mammography: The Impact of Artificial Intelligence BI-RADS Suggestions on Reader Performance

Thomas Dratsch, Xue Chen, Mohammad Rezazade Mehrizi, Roman Kloeckner, Aline Mähringer-Kunz, Michael Püsken

Twenty-seven radiologists graded fifty mammograms with BI-RADS suggestions attributed to an automated system. Some suggestions were deliberately incorrect. Correct grading declined across all experience groups when the suggestions were wrong, and less experienced readers followed certain incorrect upward suggestions more often.

SignificanceBy controlling whether the suggested category was correct, the study could directly measure how readers responded when assistance misled them. It provided a reader-study design for evaluating automation bias across experience levels in mammography interpretation.

Key2023Radiology214 citations

Methods for Clinical Evaluation of Artificial Intelligence Algorithms for Medical Diagnosis

Seong Ho Park, Kyunghwa Han, Hye Young Jang, Ji Eun Park, June-Goo Lee … Jaesoon Choi

The review covers external testing, performance measures, and reporting for diagnostic algorithms. It discusses paired designs for comparing interpretations with and without assistance on the same cases and parallel designs for evaluating the effect of an intervention. Radiology examples illustrate reader order, washout, and randomized trial design.

SignificanceThe review gives readers a common reference for linking each clinical question to an appropriate design. Its audit of two radiology journals found paired designs in 22 of 24 studies comparing assisted and unassisted diagnosis, illustrating how the published evidence was produced.

Key2023Journal of Clinical Oncology391 citations

Sybil: A Validated Deep Learning Model to Predict Future Lung Cancer Risk From a Single Low-Dose Chest Computed Tomography

Peter G. Mikhael, Jeremy Wohlwend, Adam Yala, Ludvig Karstens, Justin Xiang, Angelo K. Takigami

Sybil estimates future lung cancer risk from one low-dose chest CT over a period of up to six years without clinical inputs or nodule annotations at inference. The authors report separate validation results in held-out NLST data and hospital cohorts in the United States and Taiwan.

SignificanceThe model extended CT screening research from identifying existing lesions to estimating risk over several years. The released model enabled external evaluations, including a later screening cohort with predominantly Black participants in which investigators separately reported discrimination.

Key2023Nature Communications162 citations

Validation of MSIntuit as an AI-based pre-screening tool for MSI detection from colorectal cancer histology slides

Charlie Saillard, Rémy Dubois, Oussama Tchita, Nicolas Loiseau, Thierry Garcia, Aurélie Adriansen

The authors trained MSIntuit on The Cancer Genome Atlas and performed blinded validation in an independent cohort of 600 consecutive patients with colorectal cancer. They digitized slides on two scanners to measure the sensitivity, specificity, and cross-scanner agreement of histology-based microsatellite instability prescreening.

SignificanceThe blinded study quantified how a histology-based prediction model performed as a prescreen on independent clinical material. Sensitivity of 0.96 to 0.98 and specificity of 0.46 to 0.47 across the two scanners define the tradeoff for triaging samples to confirmatory testing.

Key2024Nature Medicine207 citations

Deep learning-aided decision support for diagnosis of skin disease across skin tones

Matthew Groh, Omar Badri, Roxana Daneshjou, Arash Koochek, Caleb Harris … Rosalind Picard

A simulated teledermatology study enrolled 848 specialist and primary-care physicians to propose differential diagnoses from photographs across skin tones. Model support improved overall diagnostic accuracy for both groups, while increasing the difference in accuracy between lighter- and darker-skin images among generalists.

SignificanceThe experiment evaluates the combined physician and model workflow across reader groups and skin tones. It shows why evaluation of the model alone or of the team's aggregate accuracy cannot substitute for subgroup analysis of the actual decisions made with assistance.

Key2024Nature Medicine295 citations

Heterogeneity and predictors of the effects of AI assistance on radiologists

Feiyang Yu, Alex Moehring, Oishi Banerjee, Tobias Salz, Nikhil Agarwal, Pranav Rajpurkar

The study analyzed algorithm-assisted reading by 140 radiologists across fifteen chest radiograph tasks. Experience, subspecialty, and familiarity with such tools did not reliably predict individual effects. In the aggregate analysis and for several individual findings, erroneous model predictions were associated with poorer reader performance.

SignificanceThe analysis separated aggregate reader performance from the effects for individual readers and findings, and examined model correctness explicitly. That design gives clinical evaluations a way to measure heterogeneity of assistance and to identify errors that affect the combined judgment.

Key2024JAMA Network Open1,129 citations

Large Language Model Influence on Diagnostic Reasoning: A Randomized Clinical Trial

Ethan Goh, Robert Gallo, Jason Hom, Eric Strong, Yingjie Weng, Hannah Kerman

Fifty physicians were randomized to use GPT-4 alongside conventional resources or to use conventional resources alone when working through clinical vignettes. Blinded graders scored diagnosis and reasoning using a standardized rubric. The study found no statistically significant improvement with access to GPT-4.

SignificanceThe trial made the clinician’s performance the main outcome and measured the model by itself separately. This distinction let researchers test whether access to a strong standalone model improves assisted diagnosis and provided a comparison for a later trial on management reasoning.

Notable2024The Lancet Digital Health487 citations

Randomised controlled trials evaluating artificial intelligence in clinical practice: a scoping review

Ryan Han, Julián N. Acosta, Zahra Shakeri, John P. A. Ioannidis, Eric J. Topol, Pranav Rajpurkar

This scoping review identified eighty-six randomized trials of machine learning interventions in clinical practice. Seventy reported favorable primary endpoints, which were most often diagnostic yield or diagnostic performance measures. Many studies were single center, and demographic and operational information was reported inconsistently.

SignificanceThe review documented the kinds of outcomes that clinical trials had measured and the information they omitted. This evidence map helps quantify how much of the reported randomized evidence concerns diagnostic performance and how often trials measured outcomes closer to patient benefit.

Key2025NEJM AI93 citations

A Pragmatic Randomized Controlled Trial of Ambient Artificial Intelligence to Improve Health Practitioner Well-Being

Majid Afshar, Mary Ryan Baumann, Felice Resnik, Josie Hintzke, Anne Gravel Sullivan, Graham Wills

A stepped-wedge randomized trial assigned 66 ambulatory practitioners to staggered access to a system that drafted notes from visit conversations. Work exhaustion and interpersonal disengagement scores fell, and practitioners spent less time on notes. The change in professional fulfillment fell short of the study’s significance threshold.

SignificanceThe trial evaluated generated documentation in routine outpatient encounters and measured practitioner experience, documentation time, and note quality. Its randomized rollout supplied evidence on how an ambient scribe changes clinical work alongside the usual assessments of the text it produces.

Notable2025Nature Medicine97 citations

An eyecare foundation model for clinical assistance: a randomized controlled trial

Yilan Wu, Bo Qian, Tingyao Li, Yiming Qin, Zhouyu Guan, Tingli Chen

EyeFM was pretrained on 14.5 million ocular images from five modalities paired with clinical text. A double-masked randomized trial at one center in China involved 668 high-risk participants and 16 ophthalmologists. Before consultant review, correct diagnosis and referral rates were both 92.2% with assistance, versus 75.4% and 80.5% with standard care.

SignificanceThe randomized study measured screening and referral decisions made by ophthalmologists. It also found higher short-term adherence to self-management and referral advice in the assisted group. The results establish endpoints for this workflow, with longer-term vision outcomes still open.

Key2025Nature Medicine330 citations

Collaboration between clinicians and vision–language models in radiology report generation

Ryutaro Tanno, David G. T. Barrett, Andrew Sellergren, Sumedh Ghaisas, Sumanth Dathathri, Abigail See

The authors trained Flamingo-CXR to generate chest radiograph reports and convened a radiologist panel to review model and clinician reports retrospectively. For inpatient and outpatient radiographs, clinically significant errors occurred in both reports in 24.8% of cases, only the generated report in 22.8%, and only the clinician report in 14.0%.

SignificanceThe error review also supplied edits for a retrospective proof of concept. Radiologists’ corrections were incorporated into model drafts, and raters compared the edited reports with the original clinical reports. Janus-Pro-CXR subsequently examined report quality and time in a prospective workflow study.

Notable2025JAMA Network Open72 citations

Efficiency and Quality of Generative AI–Assisted Radiograph Reporting

Jonathan Huang, Matthew T. Wittbrodt, Caitlin N. Teague, Eric Karl, Galal Galal, Michael Thompson

Northwestern Medicine phased in generated radiograph report drafts in its live workflow. In the prospective cohort, use was associated with 15.5% shorter documentation time compared with a pre-use baseline matched by exam type. Peer review of final radiologist-edited reports from 800 studies found no significant clinical accuracy difference.

SignificanceThe prospective cohort documents generated drafts in routine imaging within one health system. Documentation time and final report quality were assessed in separate groups of exams from the same workflow. The timing comparison estimates an association.

Key2025Nature Medicine286 citations

GPT-4 assistance for improvement of physician performance on patient care tasks: a randomized controlled trial

Ethan Goh, Robert J. Gallo, Eric Strong, Yingjie Weng, Hannah Kerman, Jason A. Freed

The trial randomized 92 practicing physicians to use GPT-4 with conventional resources or conventional resources alone for five simulated patient-management cases. Investigators scored choices about testing, treatment, and follow-up. Access to GPT-4 improved management reasoning scores, while participants spent more time per case.

SignificanceThe study measured the effect of a language model on clinician management decisions alongside time spent on the task. Together with the earlier diagnostic trial, it supplied separate evidence on collaboration for two different types of clinical reasoning.

Key2025Nature Medicine364 citations

Nationwide real-world implementation of AI for cancer detection in population-based mammography screening

Nora Eisemann, Stefan Bunk, Trasias Mukama, Hannah Baltus, Susanne A. Elsner, Timo Gomille

The PRAIM implementation study compared supported and standard double reading in an organized mammography screening program. It included 463,094 women at twelve German sites. Cancer detection was 6.7 versus 5.7 per 1,000 screened, and recall in the supported group met the study's noninferiority criterion.

SignificanceThe study documents large-scale use inside an established double-reading program. Radiologists chose whether to use the system, so the observational comparison complements randomized evidence by describing implementation in a different screening organization and reporting outcomes from routine practice.

Key2025JCO Clinical Cancer Informatics27 citations

Prospective Clinical Implementation of Paige Prostate Detect Artificial Intelligence Assistance in the Detection of Prostate Cancer in Prostate Biopsies: CONFIDENT P Trial Implementation of Artificial Intelligence Assistance in Prostate Cancer Detection

Rachel N. Flach, Carmen van Dooijeweert, Tri Q. Nguyen, Mitchell Lynch, Trudy N. Jonges, Richard P. Meijer

This prospective study compared routine assessment of prostate biopsy whole slides with assessment aided by Paige Prostate Detect in 82 patients. All morphologically negative slides in the assisted arm received immunohistochemistry. The patient-level relative risk of using immunohistochemistry per detected cancer was 0.55.

SignificanceCONFIDENT P measured an implementation outcome that matters to pathology laboratories, the use of additional staining during diagnosis. Reporting the endpoint at both patient and slide levels gives a basis for assessing resource use under the study’s biopsy workflow and staining protocol.

Key2025The Lancet Digital Health263 citations

Screening performance and characteristics of breast cancer detected in the Mammography Screening with Artificial Intelligence trial (MASAI): a randomised, controlled, parallel-group, non-inferiority, single-blinded, screening accuracy study

Veronica Hernström, Viktoria Josefsson, Hanna Sartor, David Schmidt, Anna-Maria Larsson, Solveig Hofvind

The full screening cohort of MASAI was analyzed for cancers detected at the screening visit. Detection was 6.4 versus 5.0 per 1,000 participants for supported versus standard reading. The paper describes features of detected invasive cancers and in-situ disease and reports recall and false positives.

SignificanceThis analysis complements the early safety report by characterizing the additional cancers found at screening and reporting reading workload with the full cohort. The interval-cancer publication addresses a separate prespecified question requiring follow-up after the screening visit.

Key2025Nature1,061 citations

Towards conversational diagnostic artificial intelligence

Tao Tu, Mike Schaekermann, Anil Palepu, Khaled Saab, Jan Freyberg, Ryutaro Tanno

AMIE used self-play and automated feedback to train a model for diagnostic dialogue. In a randomized, double-blind crossover study, standardized patients completed textual consultations with the system and primary care physicians. The study compared history-taking, diagnosis, and communication across 159 scenarios.

SignificanceThe study assessed diagnostic dialogue as an interaction and obtained ratings from both specialists and standardized patients. Its crossover design provided a reference for testing history-taking and communication as well as diagnostic outcomes in text-based simulated consultations.

Followed byBrodeur 2026

Notable2026Nature Communications6 citations

A DeepSeek-powered AI system for automated chest radiograph interpretation in clinical practice

Yaowei Bai, Ruiheng Zhang, Yu Lei, Xuhua Duan, Jingfeng Yao, Shuguang Ju

A prospective study across three Chinese hospitals randomized 20 radiologists to Janus-Pro-CXR assistance or standard care and enrolled 296 patients. Each exam received two independent junior reads and senior review before delivery. The assisted group had higher report quality scores and 18.3% shorter reading and reporting time.

SignificanceThe study compared reports on the same exams within a live workflow, measuring the quality and time of junior readers’ work. The shared senior review step helps define which part of the clinical workflow the reported outcomes assess.

Key2026Nature Medicine21 citations

AI-based chest X-ray prioritization in the lung cancer diagnostic pathway: the LungIMPACT randomized controlled trial

Nick Woznitza, Lesley Smith, Janette Rawlinson, Iain Au-Yong, Bindu George, Madava G. Djearaman

LungIMPACT randomized by day whether to prioritize chest radiographs on the reading worklist using software results, which were available in both arms. In 93,326 analyzed primary-care radiographs, median time to CT was 53 days in each arm and median time to lung cancer diagnosis was 44 versus 46 days. Neither difference was statistically significant.

SignificanceProviding software results in both arms let the trial isolate the effect of changing the reading order. By following patients from radiography to CT and cancer diagnosis, the study supplied randomized evidence on whether worklist prioritization speeds a defined UK referral pathway.

Key2026Nature Medicine16 citations

AI-based triage and decision support in mammography and digital tomosynthesis for breast cancer screening: a paired, noninferiority trial

Esperanza Elías-Cabot, Sara Romero-Martín, José Luis Raya-Povedano, Alejandro Rodríguez-Ruiz, Marina Álvarez-Benito

The prospective paired trial enrolled 31,301 women and compared standard double reading with a workflow that marked low-risk exams normal and sent the rest to software-assisted double reading. Radiologist workload fell by 63.6%, cancer detection rose from 6.3 to 7.3 per 1,000, and recall increased, failing its noninferiority criterion.

SignificanceThe trial quantified how removing low-risk exams from the reading queue affected workload, detection, and recall within one program. Reading reductions were similar for digital mammography and digital breast tomosynthesis, while detection and recall increased in the digital mammography subgroup. This gives readers modality-specific evidence for workflow design.

Notable2026ECCV 2026 (LNCS 17076)17 citations

CLARITY: Medical World Model for Guiding Treatment Decisions by Simulating Context-Aware Disease Trajectories

Tianxingjian Ding, Yuanhao Zou, Chen Chen, Mubarak Shah, Yu Tian

CLARITY predicts changes in imaging-derived features using elapsed time, clinical information, and treatments, then scores simulated trajectories with a survival model. Retrospective endpoints included survival prediction, agreement of proposed and recorded regimens, and a blinded expert comparison of recommendations for 40 held-out cases.

SignificanceThe work makes treatment an input to imaging state transitions. Regimen matching and expert ratings measure agreement and plausibility, respectively. The effect of an alternative treatment on an individual would require evidence beyond these retrospective comparisons.

Key2026The Lancet24 citations

Conversational diagnostic artificial intelligence in ambulatory primary care: a prospective feasibility study

Peter G. Brodeur, Jacob M. Koshy, Anil Palepu, Khaled Saab, Ava Homiar, Roma Ruparel

In a single-center, single-arm prospective study, patients conversed with AMIE before urgent primary care appointments. Physicians monitored the conversations, and the treating clinicians received the transcripts and summaries. Of 114 enrolled patients, 98 completed both steps. Supervisors recorded no prespecified safety stops and added clinical information in five interactions.

SignificanceThe study moved AMIE from simulated consultations to intake before real appointments and documented how supervision and clinician review worked in that setting. The single-arm design supplied feasibility evidence for supervised use and helped define outcomes that a controlled clinical evaluation could test.

Builds onTu 2025

Landmark2026The Lancet134 citations

Interval cancer, sensitivity, and specificity comparing AI-supported mammography screening with standard double reading without AI in the MASAI study: a randomised, controlled, non-inferiority, single-blinded, population-based, screening-accuracy trial

Jessie Gommers, Veronica Hernström, Viktoria Josefsson, Hanna Sartor, David Schmidt, Annie Hjelmgren

In the MASAI follow-up, interval cancer rates were 1.55 and 1.76 per 1,000 participants with software-assisted and standard double reading, respectively. The rate ratio was 0.88 (95% confidence interval 0.65–1.18), with the upper bound below the prespecified noninferiority margin of 1.20. Sensitivity was higher in the assisted group, and specificity was 98.5% in both groups.

SignificanceThe prespecified endpoint extended the trial's assessment beyond cancer detection on the screening day. Random assignment and follow-up make the interval-cancer findings interpretable together with the same trial's earlier evidence on screen-detected cases and reader workload.