bias and fairness
偏倚与公平性
When a model performs worse for some groups of patients, by sex, race, age, or insurance, so that they are missed more often. In imaging AI the bias usually comes from the training data, not from anyone's intent.
Bias enters in several ways: some groups are scarce in the training set, the labels carry inequities from past care, and hospitals differ in equipment and patient mix. A model with an excellent overall AUC can be clearly worse for one subgroup, and only subgroup reporting will show it.
In 2020 Agostina Larrazabal and colleagues found that chest X-ray classifiers trained on data with too few women performed worse on female patients. In 2021 Laleh Seyyed-Kalantari and colleagues, working across three large chest X-ray datasets, found that models more often labeled ill Black, Hispanic, young female, and Medicaid-insured patients as having no finding. In 2022 Judy Gichoya and colleagues showed that deep networks can recognize patients' self-reported race from radiographs, CT, and mammograms (AUC up to 0.99), which radiologists cannot do, and the authors could not pin down the image features responsible.
There is no single definition of fairness. Common practice is to report sensitivity and specificity by subgroup and to include diverse populations in external validation.
- Larrazabal AJ, Nieto N, Peterson V, Milone DH, Ferrante E. Gender imbalance in medical imaging datasets produces biased classifiers for computer-aided diagnosis. Proc Natl Acad Sci USA. 2020;117(23):12592–12594. doi.org/10.1073/pnas.1919012117
- Seyyed-Kalantari L, Zhang H, McDermott MBA, Chen IY, Ghassemi M. Underdiagnosis bias of artificial intelligence algorithms applied to chest radiographs in under-served patient populations. Nat Med. 2021;27(12):2176–2182. doi.org/10.1038/s41591-021-01595-0
- Gichoya JW, Banerjee I, Bhimireddy AR, et al. AI recognition of patient race in medical imaging: a modelling study. Lancet Digit Health. 2022;4(6):e406–e414. doi.org/10.1016/S2589-7500(22)00063-2
Key works · 18
Landmark2023Nature7,472 citations
Large language models encode clinical knowledge
The authors assembled MultiMedQA and used instruction prompt tuning to adapt Flan-PaLM to medicine. Alongside multiple-choice accuracy, human reviewers scored free-text responses for factuality, reasoning, potential harm, and bias. The medically adapted model narrowed some of the gaps with clinician responses.
SignificanceMultiMedQA brought professional examinations, research questions, and consumer questions into one evaluation suite. The Med-PaLM 2 study used those comparisons and extended the human evaluation, making it possible to measure changes in both exam performance and the quality of open-ended answers.
DOI arXiv Full text Karan SinghalShekoofeh AziziAlan KarthikesalingamVivek Natarajan large language modelfoundation modelbias and fairnesshallucination
Landmark2024BMJ7,542 citations
TRIPOD+AI statement: updated guidance for reporting clinical prediction models that use regression or machine learning methods
The update to TRIPOD set out twenty-seven reporting items for studies that develop or evaluate clinical prediction models, using either regression or machine learning. It explained the individual items and included a checklist for abstracts, covering details of data, modeling, evaluation, and open materials.
SignificanceThe update superseded the 2015 TRIPOD checklist and aligned reporting across modeling families. EQUATOR lists it for prediction model studies, where the common structure makes it easier to find evidence about development, performance evaluation, and potential transfer to another setting.
DOI Full text Gary S. CollinsPatrícia Logullo external validationbias and fairness
Key2020BMJ1,464 citations
Artificial intelligence versus clinicians: systematic review of design, reporting standards, and claims of deep learning studies
The systematic review examined study design, reporting, and risk of bias for comparisons of diagnostic deep learning with expert clinicians. Of 81 nonrandomized studies, nine were prospective and six tested systems in clinical settings. The authors also searched for registered randomized trials.
SignificanceThe review quantified the gap between retrospective expert comparisons and tests of clinical use, and examined whether published claims were supported by study design. Its separation of study designs provides a reference for assessing how subsequent imaging evaluation has changed.
DOI Full text Myura NagendranMahiben Maruthappu reader studyexternal validationbias and fairness
Key2020BMJ3,711 citations
Prediction models for diagnosis and prognosis of covid-19: systematic review and critical appraisal
This living systematic review collected models for COVID-19 diagnosis and prognosis and evaluated their populations, outcomes, validation, and risk of bias. It covered clinical predictors alongside imaging models and updated the model inventory and methodological assessments as more studies became available.
SignificanceThe successive updates document how evidence about pandemic prediction models changed over time. Applying the same risk-of-bias review to different kinds of models distinguished strong reported development scores from cases with independent validation and more reliable study methods.
DOI Full text Laure WynantsMaarten van Smeden external validationbias and fairnessground truth
Key2021Nature Medicine1,387 citations
Underdiagnosis bias of artificial intelligence algorithms applied to chest radiographs in under-served patient populations
The authors trained chest radiograph classifiers on three large datasets and a multisource combination, then measured how often models assigned a normal label to patients with findings. Their analysis compared demographic groups and found that disparities could be greater for intersecting underserved groups.
SignificanceBy measuring underdiagnosis as a distinct outcome, the study showed how aggregate performance can conceal the distribution of missed findings. Its cross-dataset and intersectional comparisons provide a concrete reference for testing how these errors are distributed across populations.
DOI Full text Laleh Seyyed-KalantariMarzyeh Ghassemi radiographybias and fairnessexternal validation
Key2022The Lancet Digital Health878 citations
AI recognition of patient race in medical imaging: a modelling study
The authors train models to predict self-reported race from medical images and test them across institutions and several modalities. They assess proposed proxy variables and perturb the images to investigate the source of the signal. The tested individual proxies did not account for the model's discrimination.
SignificanceThe finding shows why withholding demographic input fields does not prevent a model from accessing population-associated signals in the image itself. Cross-modality and external testing made the paper a reference for auditing fairness in medical image models.
DOI arXiv Full text Judy Wawira GichoyaHaoran Zhang radiographycomputed tomographymammographybias and fairness
Key2022Science Advances837 citations
Disparities in dermatology AI performance on a diverse, curated clinical image set
The authors assembled the biopsy-confirmed Diverse Dermatology Images collection and used it to assess classifiers and dermatologist visual labels across skin tones. Models performed worse on darker skin and uncommon diseases. Fine-tuning on the more diverse collection reduced the measured disparity between skin tones.
SignificanceThe public image collection and pathology reference enabled subgroup evaluation without relying on the visual labels used to train many existing models. Testing both classifiers and human visual labels gave subsequent work a way to examine label quality alongside performance disparities.
DOI arXiv Full text Roxana DaneshjouKailas VodrahalliJames ZouAlbert Chiou bias and fairnessexternal validationimage classification
Key2023npj Digital Medicine649 citations
Large language models propagate race-based medicine
The authors repeatedly queried four commercially available language models with questions developed to expose outdated race-based assumptions in medicine. Outputs from every tested model contained examples of potentially harmful race-based claims, and some answers changed when the same question was asked again.
SignificanceThe study gave safety evaluations a concrete way to test the recurrence of harmful medical assumptions through repeated prompts. Its observations show why average question-answering accuracy leaves out both content that can harm particular groups and variability across identical requests.
DOI Full text Jesutofunmi A. OmiyeRoxana Daneshjou large language modelbias and fairnesshallucination
Key2024Nature Medicine207 citations
Deep learning-aided decision support for diagnosis of skin disease across skin tones
A simulated teledermatology study enrolled 848 specialist and primary-care physicians to propose differential diagnoses from photographs across skin tones. Model support improved overall diagnostic accuracy for both groups, while increasing the difference in accuracy between lighter- and darker-skin images among generalists.
SignificanceThe experiment evaluates the combined physician and model workflow across reader groups and skin tones. It shows why evaluation of the model alone or of the team's aggregate accuracy cannot substitute for subgroup analysis of the actual decisions made with assistance.
DOI Full text Matthew GrohRosalind Picard bias and fairnessreader studyimage classification
Key2024Nature Medicine447 citations
The limits of fair medical imaging AI in real-world generalization
The authors studied demographic encodings and subgroup disparities in disease classifiers for radiology, ophthalmology, and dermatology. Mitigation could narrow measured gaps in the original data distribution, while its benefit varied on external datasets. Models with weaker demographic encodings often achieved more consistent fairness across the tested settings.
SignificanceThe study made transfer of a fairness intervention an empirical question by evaluating separate populations and institutions. Its design supports looking at overall discrimination, subgroup performance, and external gaps together when testing mitigation in a new deployment setting.
DOI arXiv Full text Yuzhe YangMarzyeh Ghassemi bias and fairnessshortcut learningexternal validation
Key2025BMJ1,422 citations
FUTURE-AI: international consensus guideline for trustworthy and deployable artificial intelligence in healthcare
The international consortium agreed on thirty recommendations spanning fairness, universality, traceability, usability, robustness, and explainability. They cover design, development, validation, deployment, and monitoring. Examples illustrate how different healthcare applications can translate the common set of recommendations into concrete evaluation and oversight practices.
SignificanceThe guidance brought testing across populations, user needs, and post-deployment monitoring into a common lifecycle framework. A subsequent medical imaging methods review used its principles to organize techniques available for operationalizing the recommendations in imaging research and deployment.
DOI arXiv Full text Karim LekadirMartijn P. A. Starmans bias and fairnessexplainabilityexternal validation
Key2025Nature Medicine630 citations
The STARD-AI reporting guideline for diagnostic accuracy studies using artificial intelligence
The STARD extension was developed by international consensus for diagnostic accuracy studies using algorithmic tests. It expands reporting on the evaluated system and the data used to assess it, with attention to provenance, reference standards, performance evaluation, and the potential for bias in intended use.
SignificanceThe extension embeds information about algorithmic tests and their evaluation data within an established diagnostic accuracy framework. It gives imaging accuracy studies a common reporting structure for examining the tested system, case selection, and the meaning of reported performance.
DOI Full text Viknesh SounderajahHutan Ashrafian sensitivity and specificityground truthbias and fairness
Notable2024The Lancet Digital Health487 citations
Randomised controlled trials evaluating artificial intelligence in clinical practice: a scoping review
This scoping review identified eighty-six randomized trials of machine learning interventions in clinical practice. Seventy reported favorable primary endpoints, which were most often diagnostic yield or diagnostic performance measures. Many studies were single center, and demographic and operational information was reported inconsistently.
SignificanceThe review documented the kinds of outcomes that clinical trials had measured and the information they omitted. This evidence map helps quantify how much of the reported randomized evidence concerns diagnostic performance and how often trials measured outcomes closer to patient benefit.
Notable2025FDA draft guidance, January 2025
Artificial Intelligence-Enabled Device Software Functions: Lifecycle Management and Marketing Submission Recommendations
In January 2025 the FDA issued draft recommendations on the total product lifecycle of device software with learned functions. The draft discusses data and development documentation, validation, user-facing information, and risk management. It proposes ways for submissions to describe post-market performance monitoring.
SignificanceThe draft documents the agency's proposed approach to maintaining evidence about real-world performance after authorization. It complements the final guidance on planned changes by describing how ongoing monitoring and other lifecycle information might be considered in a marketing submission.
US Food and Drug Administrationbias and fairnessexternal validationpostmarket monitoring
Notable2025IMDRF technical document N88
Good machine learning practice for medical device development: Guiding principles
The IMDRF document sets out ten good machine learning practice principles for developing medical devices. They address representative data, independent training and test sets, performance in clinically relevant conditions, information for users, monitoring deployed models, and evaluating the performance of the human-system team.
SignificanceThe document provides shared technical language for regulators and developers, continuing principles previously issued by national regulators. Its lifecycle framing ties deployed model monitoring to the evidence used in design and validation, including how the device is expected to be used.
Notable2025Nature Communications35 citations
Knowledge-guided adaptation of pathology foundation models effectively improves cross-domain generalization and demographic fairness
FLEX used visual and textual prior knowledge to guide a task-specific bottleneck for adapting pathology foundation models. Across three cohorts, 16 tasks, and more than 9,900 slides, the study reported improved transfer to unseen cohorts and reductions in performance differences between demographic groups.
SignificanceThe study treated cross-site transfer and demographic subgroup performance as separately measurable outcomes of pathology model adaptation. Using three cohorts gave the authors a way to test both shifts in data origin and subgroup gaps across multiple downstream tasks.
DOI Full text Yanyan HuangLi LiangShujun WangLequan Yu foundation modelwhole-slide imageexternal validationbias and fairnessdomain shift
Notable2026npj Digital Medicine26 citations
ClinicRealm: Re-evaluating large language models with conventional machine learning for non-generative clinical prediction tasks
ClinicRealm compared 15 generative language models, five BERT-style models, and 11 conventional approaches on clinical prediction using notes and structured records. Model rankings varied by input and the amount of training data available, and zero-shot models were competitive in some data-scarce settings.
SignificanceThe benchmark made clinical prediction measurable independently of medical question answering, using conventional models and zero-shot methods as direct comparisons. Its separation of notes from structured records provided a reference for evaluating models under different input and training-data conditions.
DOI arXiv Full text Yinghao ZhuChengwei PanEwen M. HarrisonLiantao MaLequan Yu large language modeltransformerbias and fairnesselectronic health record