postmarket monitoring
上市后监测
Postmarket monitoring tracks the safety and performance of a medical device in routine use. For imaging AI, it can reveal changes associated with equipment, patient populations, or workflow.
Once imaging AI enters routine use, hospitals can replace scanners, change acquisition parameters, or reorganize patient routing. Any of these changes can alter the distribution of images the model receives and can lead to domain shift. Monitoring can track input characteristics by hospital, equipment, and software version, collect reports of failures or adverse events, and estimate performance when reference outcomes are available.
A change in inputs can prompt a review of labeled cases, with accuracy estimated by equipment or hospital. Because outcomes may become known well after the original examination, performance data often lag behind the input records. Records of release dates, versions, and workflow changes help investigators assess which conditions accompanied an observed problem.
- Kelly CJ, Karthikesalingam A, Suleyman M, Corrado G, King D. Key Challenges for Delivering Clinical Impact with Artificial Intelligence. BMC Med, 2019. link.springer.com/article/10.1186/s12916-019-1426-2
- FDA. Methods and Tools for Effective Postmarket Monitoring of Artificial Intelligence (AI)-Enabled Medical Devices. www.fda.gov/medical-devices/medical-device-regulatory-science-re
Key works · 4
Key2024Canadian Association of Radiologists Journal70 citations
Developing, Purchasing, Implementing and Monitoring AI Tools in Radiology: Practical Considerations. A Multi-Society Statement From the ACR, CAR, ESR, RANZCR & RSNA
Five radiology societies issued joint recommendations on developing, purchasing, implementing, and monitoring clinical software. The statement discusses local assessment, oversight, and the risk of performance drift. It proposes that registries collect model performance, examination parameters, and patient demographics where continuous monitoring is feasible.
SignificanceThe statement makes monitoring operational by connecting changes in performance with information a radiology department can track, such as a scanner or protocol change. The five societies published the same recommendations across their journals, giving clinical teams a shared point of reference for local governance.
DOI Full text Adrian P. BradyJohn Slavotinek postmarket monitoringexternal validation
Notable2017Official Journal of the European Union, L 117
Regulation (EU) 2017/745 of the European Parliament and of the Council of 5 April 2017 on medical devices, amending Directive 2001/83/EC, Regulation (EC) No 178/2002 and Regulation (EC) No 1223/2009 and repealing Council Directives 90/385/EEC and 93/42/EEC (Text with EEA relevance.)
The Medical Device Regulation establishes rules for classification, clinical evaluation, conformity assessment, and post-market surveillance of devices. Article 83 calls for manufacturers to maintain a surveillance system proportionate to device type and risk, and related articles specify planning and reporting obligations.
SignificanceThe regulation supplies the device-law basis for conformity assessment and post-market surveillance of qualifying imaging software in the European Union. The 2024 regulation lists it in Annex I, linking the high-risk system classification to product legislation and relevant conformity assessment requirements.
Notable2024Official Journal of the European Union, L 2024/1689
Regulation (EU) 2024/1689 of the European Parliament and of the Council of 13 June 2024 laying down harmonised rules on artificial intelligence and amending Regulations (EC) No 300/2008, (EU) No 167/2013, (EU) No 168/2013, (EU) 2018/858, (EU) 2018/1139 and (EU) 2019/2144 and Directives 2014/90/EU, (EU) 2016/797 and (EU) 2020/1828 (Artificial Intelligence Act) (Text with EEA relevance)
This European Union regulation establishes obligations by system risk. Article 6 addresses systems that are products or product safety components falling under listed legislation and subject to the specified conformity assessment conditions. Requirements for high-risk systems address data governance, technical documentation, human oversight, and post-market monitoring.
SignificanceThe regulation connects certain imaging device software to a cross-sector risk framework in addition to medical device law. The 2026 amending regulation revised application dates and changed provisions affecting some product safety components. The consolidated text records both changes.
Notable2025FDA draft guidance, January 2025
Artificial Intelligence-Enabled Device Software Functions: Lifecycle Management and Marketing Submission Recommendations
In January 2025 the FDA issued draft recommendations on the total product lifecycle of device software with learned functions. The draft discusses data and development documentation, validation, user-facing information, and risk management. It proposes ways for submissions to describe post-market performance monitoring.
SignificanceThe draft documents the agency's proposed approach to maintaining evidence about real-world performance after authorization. It complements the final guidance on planned changes by describing how ongoing monitoring and other lifecycle information might be considered in a marketing submission.
US Food and Drug Administrationbias and fairnessexternal validationpostmarket monitoring