CE marking
CE认证
The mark showing that a product meets EU safety and performance law; a medical device needs it to be sold in the European Economic Area. Many AI imaging products were CE-marked before they reached the US market.
CE stands for Conformité Européenne. Unlike the US, where the FDA reviews devices itself, the EU has manufacturers demonstrate conformity with the law, for most medical devices through an independent notified body, and then affix the mark. Medical devices were long governed by the 1993 Medical Device Directive (93/42/EEC); since 26 May 2021 the stricter Medical Device Regulation (MDR, 2017/745) applies.
The MDR's Rule 11 deals with software. Software that informs diagnostic or therapeutic decisions is at least Class IIa; Class IIb if a wrong decision could seriously harm health; Class III if it could cause death or irreversible harm. As a result most imaging AI now needs a notified body, whereas under the old directive much software was self-certified as Class I.
The CE route was long seen as quicker than the FDA's, and many companies launched in Europe first. In 2022 Oxipit's ChestLink received Class IIb CE marking as the first AI to sign off normal chest X-rays autonomously. Under the EU AI Act, such products must also meet high-risk AI requirements.
- Regulation (EU) 2017/745 on medical devices (MDR), Annex VIII Rule 11. eur-lex.europa.eu/eli/reg/2017/745/oj
- Oxipit. ChestLink, CE Class IIb autonomous AI for normal chest X-ray reporting (launched April 2022). oxipit.ai/
Key works · 3
Notable2017Official Journal of the European Union, L 117
Regulation (EU) 2017/745 of the European Parliament and of the Council of 5 April 2017 on medical devices, amending Directive 2001/83/EC, Regulation (EC) No 178/2002 and Regulation (EC) No 1223/2009 and repealing Council Directives 90/385/EEC and 93/42/EEC (Text with EEA relevance.)
The Medical Device Regulation establishes rules for classification, clinical evaluation, conformity assessment, and post-market surveillance of devices. Article 83 calls for manufacturers to maintain a surveillance system proportionate to device type and risk, and related articles specify planning and reporting obligations.
SignificanceThe regulation supplies the device-law basis for conformity assessment and post-market surveillance of qualifying imaging software in the European Union. The 2024 regulation lists it in Annex I, linking the high-risk system classification to product legislation and relevant conformity assessment requirements.
Notable2024Official Journal of the European Union, L 2024/1689
Regulation (EU) 2024/1689 of the European Parliament and of the Council of 13 June 2024 laying down harmonised rules on artificial intelligence and amending Regulations (EC) No 300/2008, (EU) No 167/2013, (EU) No 168/2013, (EU) 2018/858, (EU) 2018/1139 and (EU) 2019/2144 and Directives 2014/90/EU, (EU) 2016/797 and (EU) 2020/1828 (Artificial Intelligence Act) (Text with EEA relevance)
This European Union regulation establishes obligations by system risk. Article 6 addresses systems that are products or product safety components falling under listed legislation and subject to the specified conformity assessment conditions. Requirements for high-risk systems address data governance, technical documentation, human oversight, and post-market monitoring.
SignificanceThe regulation connects certain imaging device software to a cross-sector risk framework in addition to medical device law. The 2026 amending regulation revised application dates and changed provisions affecting some product safety components. The consolidated text records both changes.
Notable2026Official Journal of the European Union, L 2026/1744
Regulation (EU) 2026/1744 of the European Parliament and of the Council of 8 July 2026 amending Regulations (EU) 2024/1689, (EU) 2018/1139 and (EU) 2023/1230 as regards the simplification of the implementation of harmonised rules on artificial intelligence (Digital Omnibus on AI) (Text with EEA relevance)
The Digital Omnibus amended provisions governing high-risk systems and the schedule for applying them. Under revised Article 113, the relevant rules for systems classified as high-risk under Article 6(1) and Annex I apply from August 2, 2028. The amending regulation entered into force on July 27, 2026.
SignificanceThe date is relevant to imaging software that falls under the medical device legislation in Annex I and satisfies the product-related high-risk conditions. The official amendment and consolidated text document the timing and the conditions to which it applies.