prospective validation
前瞻性验证
Prospective validation specifies the model version, eligibility criteria, and evaluation measures in advance, then assesses the model on cases and outcomes collected according to that protocol.
A prospective evaluation can run a model as new cases arrive, save predictions based on the information then available, and obtain reference outcomes according to the protocol. In a silent design, the outputs are withheld from clinicians, allowing investigators to measure model performance and operational failures. A study of changes in interpretation, referral, or treatment requires a workflow in which users can see the output and an appropriate comparison.
A prospective study sets the evaluation protocol before gathering validation data. External validation uses data independent of model development. A study can combine both designs. For example, a second hospital can follow a prespecified enrollment and follow-up protocol to assess performance on later cases at an independent institution.
- Vasey B, Nagendran M, Campbell B, et al. Reporting Guideline for the Early Stage Clinical Evaluation of Decision Support Systems Driven by Artificial Intelligence: DECIDE-AI. BMJ, 2022. eprints.whiterose.ac.uk/id/eprint/214334/1/bmj-2022-070904.full.
- Tikhomirov L, Semmler C, Prizant N, et al. A Scoping Review of Silent Trials for Medical Artificial Intelligence. Nature Health, 2026. doi.org/10.1038/s44360-025-00048-z
- Riley RD, Archer L, Snell KIE, et al. Evaluation of Clinical Prediction Models (Part 2): How to Undertake an External Validation Study. BMJ, 2024. doi.org/10.1136/bmj-2023-074820
Key works · 18
Landmark2018npj Digital Medicine2,097 citations
Pivotal trial of an autonomous AI-based diagnostic system for detection of diabetic retinopathy in primary care offices
The pivotal trial enrolled 900 participants with diabetes at ten primary-care sites and compared the device with reading-center grading of widefield stereoscopic photography and OCT. For detection of more-than-mild diabetic retinopathy, the study reported a sensitivity of 87.2% and a specificity of 90.7%.
SignificanceThe trial supported the FDA's 2018 De Novo authorization of IDx-DR for an autonomous screening decision in primary care. The FDA summary reports its own performance analysis and imageability assessment, providing an example of the evidence used for this intended use.
DOI Full text Michael D. AbràmoffJames C. Folk fundus photographysensitivity and specificityFDA De Novo classificationground truthprospective validation
Landmark2026The Lancet134 citations
Interval cancer, sensitivity, and specificity comparing AI-supported mammography screening with standard double reading without AI in the MASAI study: a randomised, controlled, non-inferiority, single-blinded, population-based, screening-accuracy trial
In the MASAI follow-up, interval cancer rates were 1.55 and 1.76 per 1,000 participants with software-assisted and standard double reading, respectively. The rate ratio was 0.88 (95% confidence interval 0.65–1.18), with the upper bound below the prespecified noninferiority margin of 1.20. Sensitivity was higher in the assisted group, and specificity was 98.5% in both groups.
SignificanceThe prespecified endpoint extended the trial's assessment beyond cancer detection on the screening day. Random assignment and follow-up make the interval-cancer findings interpretable together with the same trial's earlier evidence on screen-detected cases and reader workload.
DOI Jessie GommersKristina Lång mammographysensitivity and specificitytriageinterval cancernoninferiority trialprospective validation
Key2001Radiology839 citations
Screening Mammography with Computer-aided Detection: Prospective Study of 12,860 Patients in a Community Breast Center
The community breast center prospectively recorded 12,860 screening examinations. Radiologists first interpreted each examination unaided and then reviewed marked locations. The study reported more cancers detected and a higher recall rate after the second step, with the positive predictive value of biopsy unchanged.
SignificanceThis study supplied prospective evidence on adding marks to a community screening workflow and quantified the associated increase in recall. Subsequent large registry studies used different designs to assess whether such changes generalized across facilities and readers.
DOI Timothy W. FreerMichael J. Ulissey computer-aided detection & diagnosismammographysensitivity and specificityprospective validation
Key2019Gut1,021 citations
Real-time automatic detection system increases colonoscopic polyp and adenoma detection rates: a prospective randomised controlled study
This prospective randomized trial compared standard colonoscopy with a workflow that issued real-time prompts for suspected polyps. Among 1,058 participants, adenoma detection was 29.1% in the assisted arm and 20.3% in the control arm, with the increase concentrated in diminutive adenomas.
SignificanceThe trial evaluated how live detection prompts affected a procedural endpoint during colonoscopy. Reporting the contribution of small and larger adenomas also clarified which lesions accounted for the overall change, an important distinction when interpreting the clinical value of extra detections.
DOI Pu WangXiaogang Liu endoscopyobject detectioncomputer-aided detection & diagnosisprospective validation
Key2022The Lancet Digital Health301 citations
Real-time diabetic retinopathy screening by deep learning in a multisite national screening programme: a prospective interventional cohort study
A prospective cohort at nine Thai primary-care sites used a system to interpret fundus photographs and generate referrals in real time, with retina specialists reviewing every image for safety. Against adjudicated grades, sensitivity for vision-threatening diabetic retinopathy was 91.4% and specificity was 95.4%.
SignificanceThe cohort added evidence from a national screening program and routine image acquisition to earlier retrospective work. Recording performance alongside ungradable examinations and referral recommendations made it possible to assess the screening program's operational feasibility as well as its diagnostic accuracy.
DOI Paisan RuamviboonsukRory SayresDale R. Webster fundus photographyexternal validationsensitivity and specificityreference standard adjudicationprospective validation
Key2023The Lancet Digital Health487 citations
Artificial intelligence for breast cancer detection in screening mammography in Sweden: a prospective, population-based, paired-reader, non-inferiority study
ScreenTrustCAD enrolled 55,581 women in a Swedish screening program and compared two reading strategies on the same mammograms. One radiologist and software reading independently detected 261 cancers within three months, compared with 250 detected by two radiologists, meeting the prespecified noninferiority criterion.
SignificanceThe paired design tested software as a replacement for one independent reader within a routine screening program. The trial hospital subsequently put this reading arrangement into clinical use, and a follow-up implementation study documented the risks and mitigation measures identified by staff.
DOI Full text Karin DembrowerFredrik Strand mammographyreader studynoninferiority trialprospective validation
Key2023The Lancet Oncology807 citations
Artificial intelligence-supported screen reading versus standard double reading in the Mammography Screening with Artificial Intelligence trial (MASAI): a clinical safety analysis of a randomised, controlled, non-inferiority, single-blinded, screening accuracy study
MASAI randomly assigned screening participants to software-supported mammography reading or standard double reading. The early clinical safety analysis involved about 80,000 participants. Detection rates were 6.1 and 5.1 per 1,000 screened, respectively, and the supported workflow reduced screen-reading workload by 44.3%.
SignificanceThis interim safety analysis counted screen readings alongside cancer detections in an organized screening program. Later reports from the same randomized trial examined screen-detected cancers in the full cohort and evaluated the primary interval-cancer endpoint after follow-up.
DOI Kristina LångAldana Rosso mammographytriagereader studyprospective validation
Key2023JAMA Dermatology114 citations
Assessment of Diagnostic Performance of Dermatologists Cooperating With a Convolutional Neural Network in a Prospective Clinical Study: Human With Machine
Dermatologists at two centers prospectively assessed 228 suspicious melanocytic lesions and reconsidered their decisions after seeing a convolutional network score. Reference diagnoses came from histopathology or, for nonexcised lesions, follow-up and expert consensus. Sensitivity rose from 84.2% to 100%, and specificity from 72.1% to 83.7%.
SignificanceRecording clinical assessments and management plans before and after score disclosure linked dermoscopy model performance to decisions made during the visit. Proposed excisions of benign nevi fell from 104 to 84, giving prospective evidence on how assistance could change the management of suspicious lesions.
DOI Full text Julia K. WinklerHolger A. Haenssle dermoscopysensitivity and specificityreference standard adjudicationprospective validation
Key2025NEJM AI93 citations
A Pragmatic Randomized Controlled Trial of Ambient Artificial Intelligence to Improve Health Practitioner Well-Being
A stepped-wedge randomized trial assigned 66 ambulatory practitioners to staggered access to a system that drafted notes from visit conversations. Work exhaustion and interpersonal disengagement scores fell, and practitioners spent less time on notes. The change in professional fulfillment fell short of the study’s significance threshold.
SignificanceThe trial evaluated generated documentation in routine outpatient encounters and measured practitioner experience, documentation time, and note quality. Its randomized rollout supplied evidence on how an ambient scribe changes clinical work alongside the usual assessments of the text it produces.
DOI Full text Majid AfsharJoel Gordon large language modelprospective validation
Key2025Nature Medicine364 citations
Nationwide real-world implementation of AI for cancer detection in population-based mammography screening
The PRAIM implementation study compared supported and standard double reading in an organized mammography screening program. It included 463,094 women at twelve German sites. Cancer detection was 6.7 versus 5.7 per 1,000 screened, and recall in the supported group met the study's noninferiority criterion.
SignificanceThe study documents large-scale use inside an established double-reading program. Radiologists chose whether to use the system, so the observational comparison complements randomized evidence by describing implementation in a different screening organization and reporting outcomes from routine practice.
DOI Full text Nora EisemannStefan BunkAlexander Katalinic mammographyexternal validationsensitivity and specificityprospective validation
Key2025JCO Clinical Cancer Informatics27 citations
Prospective Clinical Implementation of Paige Prostate Detect Artificial Intelligence Assistance in the Detection of Prostate Cancer in Prostate Biopsies: CONFIDENT P Trial Implementation of Artificial Intelligence Assistance in Prostate Cancer Detection
This prospective study compared routine assessment of prostate biopsy whole slides with assessment aided by Paige Prostate Detect in 82 patients. All morphologically negative slides in the assisted arm received immunohistochemistry. The patient-level relative risk of using immunohistochemistry per detected cancer was 0.55.
SignificanceCONFIDENT P measured an implementation outcome that matters to pathology laboratories, the use of additional staining during diagnosis. Reporting the endpoint at both patient and slide levels gives a basis for assessing resource use under the study’s biopsy workflow and staining protocol.
DOI Full text Rachel N. FlachPaul J. van Diest digital pathologywhole-slide imagehistopathologyprospective validation
Key2025The Lancet Digital Health263 citations
Screening performance and characteristics of breast cancer detected in the Mammography Screening with Artificial Intelligence trial (MASAI): a randomised, controlled, parallel-group, non-inferiority, single-blinded, screening accuracy study
The full screening cohort of MASAI was analyzed for cancers detected at the screening visit. Detection was 6.4 versus 5.0 per 1,000 participants for supported versus standard reading. The paper describes features of detected invasive cancers and in-situ disease and reports recall and false positives.
SignificanceThis analysis complements the early safety report by characterizing the additional cancers found at screening and reporting reading workload with the full cohort. The interval-cancer publication addresses a separate prespecified question requiring follow-up after the screening visit.
DOI Veronica HernströmKristina Lång mammographysensitivity and specificitytriageprospective validation
Key2026Nature Medicine21 citations
AI-based chest X-ray prioritization in the lung cancer diagnostic pathway: the LungIMPACT randomized controlled trial
LungIMPACT randomized by day whether to prioritize chest radiographs on the reading worklist using software results, which were available in both arms. In 93,326 analyzed primary-care radiographs, median time to CT was 53 days in each arm and median time to lung cancer diagnosis was 44 versus 46 days. Neither difference was statistically significant.
SignificanceProviding software results in both arms let the trial isolate the effect of changing the reading order. By following patients from radiography to CT and cancer diagnosis, the study supplied randomized evidence on whether worklist prioritization speeds a defined UK referral pathway.
DOI Full text Nick WoznitzaDavid R. Baldwin radiographycomputed tomographytriageprospective validation
Key2026Nature Medicine16 citations
AI-based triage and decision support in mammography and digital tomosynthesis for breast cancer screening: a paired, noninferiority trial
The prospective paired trial enrolled 31,301 women and compared standard double reading with a workflow that marked low-risk exams normal and sent the rest to software-assisted double reading. Radiologist workload fell by 63.6%, cancer detection rose from 6.3 to 7.3 per 1,000, and recall increased, failing its noninferiority criterion.
SignificanceThe trial quantified how removing low-risk exams from the reading queue affected workload, detection, and recall within one program. Reading reductions were similar for digital mammography and digital breast tomosynthesis, while detection and recall increased in the digital mammography subgroup. This gives readers modality-specific evidence for workflow design.
DOI Full text Esperanza Elías-CabotMarina Álvarez-Benito mammographytomosynthesistriagereader studynoninferiority trialprospective validation
Key2026The Lancet24 citations
Conversational diagnostic artificial intelligence in ambulatory primary care: a prospective feasibility study
In a single-center, single-arm prospective study, patients conversed with AMIE before urgent primary care appointments. Physicians monitored the conversations, and the treating clinicians received the transcripts and summaries. Of 114 enrolled patients, 98 completed both steps. Supervisors recorded no prespecified safety stops and added clinical information in five interactions.
SignificanceThe study moved AMIE from simulated consultations to intake before real appointments and documented how supervision and clinician review worked in that setting. The single-arm design supplied feasibility evidence for supervised use and helped define outcomes that a controlled clinical evaluation could test.
DOI arXiv Peter G. BrodeurAdam M. Rodman large language modelAI agentprospective validation
Notable2025Nature Medicine97 citations
An eyecare foundation model for clinical assistance: a randomized controlled trial
EyeFM was pretrained on 14.5 million ocular images from five modalities paired with clinical text. A double-masked randomized trial at one center in China involved 668 high-risk participants and 16 ophthalmologists. Before consultant review, correct diagnosis and referral rates were both 92.2% with assistance, versus 75.4% and 80.5% with standard care.
SignificanceThe randomized study measured screening and referral decisions made by ophthalmologists. It also found higher short-term adherence to self-management and referral advice in the assisted group. The results establish endpoints for this workflow, with longer-term vision outcomes still open.
DOI foundation modelvision–language modelfundus photographyoptical coherence tomographyprospective validation
Notable2025JAMA Network Open72 citations
Efficiency and Quality of Generative AI–Assisted Radiograph Reporting
Northwestern Medicine phased in generated radiograph report drafts in its live workflow. In the prospective cohort, use was associated with 15.5% shorter documentation time compared with a pre-use baseline matched by exam type. Peer review of final radiologist-edited reports from 800 studies found no significant clinical accuracy difference.
SignificanceThe prospective cohort documents generated drafts in routine imaging within one health system. Documentation time and final report quality were assessed in separate groups of exams from the same workflow. The timing comparison estimates an association.
DOI Full text radiographyradiology report generationprospective validation
Notable2026Nature Communications6 citations
A DeepSeek-powered AI system for automated chest radiograph interpretation in clinical practice
A prospective study across three Chinese hospitals randomized 20 radiologists to Janus-Pro-CXR assistance or standard care and enrolled 296 patients. Each exam received two independent junior reads and senior review before delivery. The assisted group had higher report quality scores and 18.3% shorter reading and reporting time.
SignificanceThe study compared reports on the same exams within a live workflow, measuring the quality and time of junior readers’ work. The shared senior review step helps define which part of the clinical workflow the reported outcomes assess.
DOI arXiv Full text radiographyvision–language modelradiology report generationprospective validation