Modalities

digital pathology

数字病理

Scanning glass pathology slides into high-resolution whole-slide images so they can be read on screen, archived and shared. It turned pathology into a digital discipline and made it accessible to computational analysis and AI.

Traditionally a pathologist reads a glass slide under a microscope; there is one copy, and a second opinion means posting it. Digital pathology starts with a whole-slide scanner that photographs the slide tile by tile and stitches the tiles into a single image that can be panned and zoomed on screen, backed by image management, viewing software and links to hospital systems, much as picture archiving and communication system serves radiology.

Virtual microscopy emerged in the 1990s, but scanning speed, storage and networks held it back for years. On 12 April 2017 the FDA granted De Novo authorization to the Philips IntelliSite Pathology Solution, the first whole-slide imaging system allowed for primary diagnosis in surgical pathology, after a study of about 2,000 cases found digital reads comparable to glass.

Once digitized, slides can be used to count cells, quantify immunostains and train AI, from the lymph-node metastasis detection of CAMELYON to today's pathology foundation models. The price is storage: a single slide often takes a gigabyte or so.

Sources
  1. FDA. FDA allows marketing of first whole slide imaging system for digital pathology. Press release, 12 Apr 2017. www.fda.gov/news-events/press-announcements/fda-allows-marketing

Key works · 10

Landmark2009IEEE International Symposium on Biomedical Imaging (ISBI)1,879 citations

A method for normalizing histology slides for quantitative analysis

Marc Macenko, Marc Niethammer … Nancy E. Thomas

Variation in slide preparation and storage complicates quantitative comparisons of stained tissue. The paper estimated the principal stain directions in optical-density space and adjusted their intensity scales relative to a reference. The resulting normalization made the appearance of slides processed under different conditions more comparable.

SignificanceMacenko normalization became a reference for preprocessing H&E images and is implemented in Slideflow. A later comparison using material from nine pathology laboratories found that the tested normalization methods alone did not reliably overcome the effect of stain variation on classification across sites.

Landmark2013Journal of Pathology Informatics660 citations

OpenSlide: A vendor-neutral software foundation for digital pathology

Adam Goode, Benjamin Gilbert … Mahadev Satyanarayanan

Digital scanners stored whole slides in incompatible vendor formats. OpenSlide implemented a common, read-only C interface for retrieving regions at multiple resolutions and reading slide metadata. The paper showed how this interface could support slide management and content-based search across files from different scanners.

SignificanceBy exposing a common region-reading interface, OpenSlide let downstream software support new slide formats without rewriting its analysis code. The paper documents adoption by the VIPS image-processing system and slide databases. QuPath subsequently used it as a backend for opening proprietary whole-slide files.

Landmark2013Archives of Pathology & Laboratory Medicine680 citations

Validating Whole Slide Imaging for Diagnostic Purposes in Pathology: Guideline from the College of American Pathologists Pathology and Laboratory Quality Center

Liron Pantanowitz, John H. Sinard … Lydia Contis

The College of American Pathologists combined a systematic review with expert assessment to formulate recommendations for local validation of whole-slide imaging. Laboratories were advised to select cases representative of intended use and compare the same pathologist’s diagnoses on digital and glass slides, with a washout period between readings.

SignificanceThe guideline gave pathology laboratories a common framework for showing that a digital workflow was suitable for their own case mix and intended use. The subsequent CAP update reaffirmed the 60-case minimum, within-reader diagnostic concordance, and a two-week washout.

Landmark2017Scientific Reports10,125 citations

QuPath: Open source software for digital pathology image analysis

Peter Bankhead, Maurice B. Loughrey … Philip D. Dunne

QuPath provided a desktop environment for visualizing whole slides, finding objects, quantifying biomarkers, and running analysis scripts in batches. The authors illustrated its use on colorectal cancer material and provided extension points for adding analysis methods to the same viewing and annotation interface.

SignificanceQuPath made it possible to share image analysis scripts alongside a viewer capable of inspecting their output on the original slides. A later protocol for quantifying fluorescently labeled cell populations used QuPath and published the scripts needed to reproduce the analysis.

Landmark2018The American Journal of Surgical Pathology457 citations

Whole Slide Imaging Versus Microscopy for Primary Diagnosis in Surgical Pathology: A Multicenter Blinded Randomized Noninferiority Study of 1992 Cases (Pivotal Study)

Sanjay Mukhopadhyay, Michael D. Feldman … Nicolas G. Cacciabeve

In this blinded randomized study, 16 pathologists at four institutions reviewed slides by digital whole-slide imaging and light microscopy, using the original diagnosis as the reference. In 1,992 cases, the major discordance rates were 4.9% and 4.6%, respectively, meeting the prespecified noninferiority criterion.

SignificanceThe FDA cited this pivotal study when it granted Philips IntelliSite the first US marketing authorization for a whole-slide imaging system for primary surgical pathology diagnosis. The study linked authorization to a prespecified diagnostic endpoint across a broad surgical case mix.

Landmark2019Nature Medicine3,479 citations

Clinical-grade computational pathology using weakly supervised deep learning on whole slide images

Gabriele Campanella, Matthew G. Hanna … Klaus J. Busam

Using diagnoses from reports as supervision, the authors trained slide classifiers without manually tracing lesions. They evaluated the system on 44,732 routine whole-slide images from 15,187 patients. Areas under the ROC curve exceeded 0.98 for prostate cancer, basal cell carcinoma, and breast cancer nodal metastases.

SignificanceThe study established routine pathology archives as a practical source of large-scale supervision for whole-slide classification. It was a reference point for CLAM, which examined how to retain the slide-label training setup while reducing the quantity of labeled material required.

Key2022Archives of Pathology & Laboratory Medicine272 citations

Validating Whole Slide Imaging Systems for Diagnostic Purposes in Pathology: Guideline Update From the College of American Pathologists in Collaboration With the American Society for Clinical Pathology and the Association for Pathology Informatics

Andrew J. Evans, Richard W. Brown … Danny A. Milner Jr

The expert panel reviewed studies published after the original 2013 guideline and updated the validation recommendations for diagnostic whole-slide imaging. It reaffirmed testing at least 60 cases, assessing within-observer concordance between digital and glass slides, and using a washout of at least two weeks.

SignificanceThe active CAP guideline makes local concordance testing operational and specifies how to handle disagreements between reading modalities. Graded recommendations and practice statements give laboratories a common validation procedure while clarifying which elements are supported by stronger evidence.

Key2025JCO Clinical Cancer Informatics27 citations

Prospective Clinical Implementation of Paige Prostate Detect Artificial Intelligence Assistance in the Detection of Prostate Cancer in Prostate Biopsies: CONFIDENT P Trial Implementation of Artificial Intelligence Assistance in Prostate Cancer Detection

Rachel N. Flach, Carmen van Dooijeweert … Richard P. Meijer

This prospective study compared routine assessment of prostate biopsy whole slides with assessment aided by Paige Prostate Detect in 82 patients. All morphologically negative slides in the assisted arm received immunohistochemistry. The patient-level relative risk of using immunohistochemistry per detected cancer was 0.55.

SignificanceCONFIDENT P measured an implementation outcome that matters to pathology laboratories, the use of additional staining during diagnosis. Reporting the endpoint at both patient and slide levels gives a basis for assessing resource use under the study’s biopsy workflow and staining protocol.

Notable2025Nature Communications235 citations

A clinical benchmark of public self-supervised pathology foundation models

Gabriele Campanella, Shengjia Chen … Jennifer Zeng

Using routine-care slides from three medical centers, the study held public self-supervised tile encoders fixed and trained slide aggregators under a common protocol. It compared their features on tasks including cancer diagnosis and biomarker prediction, and made the automated benchmarking pipeline available for external use.

SignificanceApplying one evaluation protocol across models made comparisons possible on consistent clinical tasks, using material from several institutions and scanner vendors. The benchmark provides evidence for selecting a feature extractor by task and gives other researchers a way to compare subsequent models.

Notable2026Nature Medicine34 citations

End-to-end multimodal pathology foundation model with clinical dialogue

Eugene Vorontsov, George Shaikovski … Neil Tenenholtz

PRISM2 used specimen-level reports and derived question–answer pairs associated with around 2.3 million slides to learn slide-level features. Its authors compared prompted invasive cancer detection with existing products on their respective test sets and evaluated transfer to selected tasks on external public data.

SignificanceClinical dialogue supplied supervision at slide level. Comparisons on the test datasets of existing products provide task-specific benchmarks for prompted cancer detection, alongside evidence from separate evaluations about transfer of slide representations to externally sourced data.