In a US medical device marketing submission, a predetermined change control plan describes planned modifications, how they will be developed, validated, and implemented, and their impact on safety and effectiveness.

The US FDA can review a predetermined change control plan during a marketing submission for an AI-enabled device. For software expected to expand to additional scanners, the plan can describe eligible scanner types, how data will be collected and evaluated, which acceptance criteria apply, and how a qualifying update will be implemented and documented.

The impact assessment considers device safety and effectiveness, including risks that can accumulate across changes. Manufacturers can develop, validate, and implement changes within the authorized scope using the methods in the plan. Updates outside that scope are assessed under the applicable regulatory requirements for device modifications.

Sources
  1. FDA. Marketing Submission Recommendations for a Predetermined Change Control Plan for Artificial Intelligence-Enabled Device Software Functions. Final guidance, August 2025. www.fda.gov/regulatory-information/search-fda-guidance-documents

Key works · 2

Notable2025FDA final guidance, August 2025

Marketing Submission Recommendations for a Predetermined Change Control Plan for Artificial Intelligence-Enabled Device Software Functions

U.S. Food and Drug Administration

The FDA final guidance describes predetermined change control plans for eligible device software submitted through the 510(k), De Novo, and premarket approval pathways. It recommends describing the planned changes, the protocol for developing, validating, and implementing them, and an assessment of their impact.

SignificanceThe guidance explains how the FDA evaluates a change plan within a marketing submission. Once authorized, the plan can cover specified future changes, connecting those software updates to pre-established validation methods and impact assessments while preserving continued regulatory oversight.

Notable2026IMDRF technical document N90

Essential Principles and Content of Predetermined Change Control Plans

International Medical Device Regulators Forum

This final IMDRF technical document describes predetermined change control plans for medical device software. It organizes content around a description of intended changes, a plan for making and controlling those changes, and impact assessment. It connects documentation of software changes with safety and performance evidence.

SignificanceThe document gives regulators a common basis for discussing software changes specified in advance. Its structure allows comparison of proposed change scopes and verification plans across jurisdictions while leaving the handling of particular submissions to the applicable national framework.