free-response ROCFROC

自由响应ROC

Free-response ROC evaluates detection tasks that allow multiple location marks on each image. It relates the fraction of lesions found to the average number of false marks per image.

A nodule detector can assign confidence scores to several candidate locations in one CT examination. An evaluation specifies a matching rule in advance, such as requiring a mark to land within a defined distance of a reference lesion. For each score threshold, it computes the fraction of reference lesions localized and the mean number of false marks per image or examination.

Lowering the threshold usually retains more correct locations and more unrelated marks. The free-response curve shows that trade-off across thresholds. The horizontal axis is the mean number of false marks per image or examination, and the vertical axis is the lesion detection fraction. The matching distance and treatment of repeated marks affect the coordinates at each threshold.

Sources
  1. Chakraborty DP. A Status Report on Free-response Analysis. Radiat Prot Dosimetry, 2010. pmc.ncbi.nlm.nih.gov/articles/PMC2868098/

Key works · 3

Landmark1987Medical Physics391 citations

Image feature analysis and computer-aided diagnosis in digital radiography. I. Automated detection of microcalcifications in mammography

Heang-Ping Chan, Kunio Doi … Peter M. Jokich

The detector subtracted a signal-suppressed image from a signal-enhanced image to reduce structured mammographic background, then selected candidates using physical characteristics of microcalcifications. With simulated clusters placed on normal backgrounds, it detected roughly 80% of clusters at about one false-positive cluster per image.

SignificanceThe study established a candidate-generation and feature-screening procedure with a measurable sensitivity and false-positive tradeoff. The same research program then used controlled reader studies to determine whether providing such candidate marks improved radiologists' recognition of microcalcification clusters.

Key1989Medical Physics221 citations

Maximum likelihood analysis of free-response receiver operating characteristic (FROC) data

Dev P. Chakraborty

For reader studies that require localization, the paper modeled the scores of signal marks and the production of false-positive marks in free-response ROC data. FROCFIT estimated model parameters and their uncertainties with maximum likelihood. The author reported fits to several experimental data sets.

SignificanceThe paper supplied a statistical model for experiments in which readers can mark several locations per image. Free-response analysis later informed reader-based imaging benchmarks, including the low-dose CT challenge that used a jackknife alternative for evaluating marks of liver metastases.

Key2017Medical Physics425 citations

Low-dose CT for the detection and classification of metastatic liver lesions: Results of the 2016 Low Dose CT Grand Challenge

Cynthia H. McCollough, Adam C. Bartley … Phillip Edwards

The Low Dose CT Grand Challenge supplied common contrast-enhanced CT cases to groups testing image-space denoising or iterative reconstruction. Participants reconstructed twenty quarter-dose test examinations. Eleven blinded readers marked liver metastases, with substantial differences in reader scores across the submitted reconstruction and denoising methods.

SignificanceThe competition tied reconstruction evaluation to the clinical task of detecting liver metastases. The Cancer Imaging Archive's larger collection includes 13 of the challenge test cases. A separate release provides all 30 training and test cases in the same standardized projection format for further comparisons.