Cynthia H. McCollough

Evaluated multidetector, dual-source, and clinical photon-counting CT.

CT imaging and reconstruction ORCID OpenAlex

Mayo Clinic (2023)

Key works · 3

Landmark2022Radiology652 citations

First Clinical Photon-counting Detector CT System: Technical Evaluation

Kishore Rajendran, Martin Petersilka … Thomas G. Flohr

The authors characterized a clinical dual-source photon-counting CT scanner with phantom measurements and example examinations from four participants. They measured spatial resolution, noise, section response, and iodine quantitation. The high-resolution configuration achieved a maximum measured in-plane resolution of 125 micrometers.

SignificanceThe evaluation documented performance at the clinical introduction of a commercial photon-counting CT system. A contemporaneous technical baseline for high-resolution imaging and spectral quantitation allowed later assessments, including the Radiology milestones review, to compare these capabilities with earlier CT technology.

Key2005Medical Physics300 citations

Image reconstruction and image quality evaluation for a 64-slice CT scanner with z-flying focal spot

T. G. Flohr, K. Stierstorfer … C. H. McCollough

A CT scanner alternated its focal spot between two longitudinal positions, interleaving the samples from 32 detector rows to acquire 64 overlapping sections per rotation. The study measured longitudinal resolution, section profiles, and noise and evaluated helical image quality using phantom and patient scans.

SignificanceThe scanner demonstrated that geometry could increase longitudinal sampling density beyond the physical detector row count. The technique was implemented in a commercial 64-section system, supporting thin-section volume acquisitions and reformats through the resulting data in multiple planes.

Key2017Medical Physics425 citations

Low-dose CT for the detection and classification of metastatic liver lesions: Results of the 2016 Low Dose CT Grand Challenge

Cynthia H. McCollough, Adam C. Bartley … Phillip Edwards

The Low Dose CT Grand Challenge supplied common contrast-enhanced CT cases to groups testing image-space denoising or iterative reconstruction. Participants reconstructed twenty quarter-dose test examinations. Eleven blinded readers marked liver metastases, with substantial differences in reader scores across the submitted reconstruction and denoising methods.

SignificanceThe competition tied reconstruction evaluation to the clinical task of detecting liver metastases. The Cancer Imaging Archive's larger collection includes 13 of the challenge test cases. A separate release provides all 30 training and test cases in the same standardized projection format for further comparisons.