MG·LB · Key works

CT imaging and reconstruction

In the exhibits2.1 The mathematical basis of tomographic reconstruction2.2 The first CT scanner2.3 Sinograms and back-projection2.4 Filtered back-projection2.5 Hounsfield units and windowing2.6 Scanner generations and radiation dose7.2 Digital radiographs and spiral CT8.5 Scanner advances: multidetector CT, PET/CT and 3 T MRI9.4 Dual-source CT, tomosynthesis and PET/MR11.3 New imaging systems

Landmark1913Physical Review164 citations

A Powerful Röntgen Ray Tube with a Pure Electron Discharge

W. D. Coolidge

Coolidge described an X-ray tube in which a heated tungsten filament supplies electrons in a high vacuum. A separate high voltage accelerates the electrons toward the target. The design let the operator regulate tube current through filament heating and control the energy of the electrons through the accelerating voltage.

SignificanceThe hot cathode and high vacuum made X-ray generation more reproducible and gave operators separate control over tube current and voltage. The IAEA diagnostic radiology physics handbook describes thermionic emission as the operating principle of modern diagnostic X-ray tubes.

Landmark1923Physical Review1,936 citations

A Quantum Theory of the Scattering of X-rays by Light Elements

Arthur H. Compton

Compton modeled the scattering of X-rays by light elements as an exchange of energy and momentum between one radiation quantum and one electron. The model predicted a wavelength shift that depended on the scattering angle, in agreement with observations including the shifted line from graphite.

SignificanceCompton received the 1927 Nobel Prize in Physics for this effect. Compton scattering accounts for much of the photon attenuation in soft tissue at diagnostic energies and also sends off-axis photons toward the detector, where they reduce radiographic contrast.

Key1956Australian Journal of Physics819 citations

Strip Integration in Radio Astronomy

R. N. Bracewell

Bracewell analyzed how scanning a radio source with a long, narrow telescope beam integrates the true distribution along strips. He related recoverable resolution to the beam profile and gave a method for reconstructing the source distribution from scans made at different orientations.

SignificanceThe paper gives an early application of the relationship between projections and spatial frequencies. The same relationship later explained how angular measurements provide the frequency information needed to recover a cross-sectional image in medical tomography.

Landmark1963Journal of Applied Physics1,737 citations

Representation of a Function by Its Line Integrals, with Some Radiological Applications

A. M. Cormack

Cormack derived a way to recover a function on a finite region from the integrals along the lines that intersect it. He formulated applications to X-ray attenuation, positron annihilation distributions, and density estimation using the energy loss of charged particles.

SignificanceCormack formulated projection inversion as a problem in radiological physics. The 1979 Nobel Prize in Physiology or Medicine jointly recognized Cormack's theoretical contributions to reconstruction and Hounsfield's independent development of a practical computerized X-ray scanner.

Followed byCormack 1964

Key1964Journal of Applied Physics758 citations

Representation of a Function by Its Line Integrals, with Some Radiological Applications. II

A. M. Cormack

Cormack applied his reconstruction method to gamma-ray transmission measurements taken outside a test object. The experiment compared the reconstructed attenuation distribution with the known sample structure. It demonstrated that the mathematical procedure could recover information about the interior from external measurements.

SignificanceThe experiment made the inversion a physical measurement procedure as well as a mathematical result. Cormack's Nobel lecture describes this experimental test alongside the derivation as part of the development of transmission tomography in radiology.

Builds onCormack 1963

Landmark1970Journal of Theoretical Biology3,225 citations

Algebraic Reconstruction Techniques (ART) for three-dimensional electron microscopy and X-ray photography

Richard Gordon, Robert Bender, Gabor T. Herman

The authors treated projection measurements as linear constraints on the image. Their reconstruction repeatedly compared one predicted ray sum with the measured value and updated the pixels along that ray. They applied the method to recover asymmetric objects from a limited set of views.

SignificanceART established a computational approach to image reconstruction using successive corrections from measured projections. Later work retained that principle while changing how the updates are grouped. Simultaneous ART, for example, combines corrections from all rays at a projection angle.

Landmark1971Proceedings of the National Academy of Sciences1,192 citations

Three-dimensional Reconstruction from Radiographs and Electron Micrographs: Application of Convolutions instead of Fourier Transforms

G. N. Ramachandran, A. V. Lakshminarayanan

The paper replaced direct two-dimensional Fourier computation in projection reconstruction with a one-dimensional convolution on each projection. The authors assembled the filtered data from different angles into sections and reported faster computation and greater accuracy in their tests using simulated projections.

SignificanceThe formulation made the filtering stage of CT reconstruction practical with a spatial-domain kernel. The IAEA handbook describes convolution followed by back-projection as a classical CT method and identifies the ramp filter by the authors' names, Ram–Lak.

Landmark1973British Journal of Radiology5,075 citations

Computerized transverse axial scanning (tomography): Part 1. Description of system

G. N. Hounsfield

Hounsfield described a head scanner that measured X-ray transmission through the same section at many angles. A computer estimated the attenuation of the individual elements of the section from those readings. The resulting images resolved differences between soft tissues with similar attenuation.

SignificanceThe EMI system put projection acquisition, numerical reconstruction, and section display into a scanner that could be used on patients. Hounsfield and Cormack shared the 1979 Nobel Prize in Physiology or Medicine for the development of computer-assisted tomography.

Key1973British Journal of Radiology997 citations

Computerized transverse axial scanning (tomography): Part 2. Clinical application

James Ambrose

Ambrose described how to read the sections produced by the early head scanner. Anatomical structures could be localized and characterized by attenuation, and deviations could be compared with expected pathological changes. Examples included high attenuation from blood clots and calcification in tumors.

SignificanceThe clinical paper documented that CT could localize and characterize intracranial lesions using the reconstructed tissue attenuation. The historical review in Radiology identifies the first patient examination by Ambrose and Hounsfield as the start of clinical CT.

Landmark1974Science192 citations

Computerized Transaxial X-ray Tomography of the Human Body

R. S. Ledley, G. Di Chiro, A. J. Luessenhop, H. L. Twigg

The paper described the ACTA scanner for transaxial imaging of multiple body regions. It reported experience in the brain, orbits, and skull base and discussed the potential of the wider scanner geometry for examining the chest, abdomen, spine, and other regions.

SignificanceACTA extended clinical CT beyond dedicated head examinations. Its geometry allowed cross-sectional imaging in multiple body regions, a capability that would become routine in diagnostic CT. The Smithsonian archives identify ACTA as the first whole-body diagnostic CT system.

Landmark1974IEEE Transactions on Nuclear Science2,514 citations

The Fourier reconstruction of a head section

L. A. Shepp, B. F. Logan

Shepp and Logan used a mathematical head phantom built from ellipses to test a Fourier reconstruction against a search algorithm. They proposed a modified weighting function and compared the methods for computational effort, spatial resolution, and sensitivity to noise in the simulated data.

SignificanceThe phantom gave researchers a reproducible object with a known structure and calculable projections. The Shepp–Logan phantom remains available in numerical imaging software and continues to serve as a common test object for tomographic reconstruction.

Landmark1976Physics in Medicine & Biology2,291 citations

Energy-selective reconstructions in X-ray computerised tomography

R. E. Alvarez, A. Macovski

Alvarez and Macovski represented the energy dependence of X-ray attenuation with a small number of coefficients. They showed that coarse spectral measurements, combined with conventional tomography, could recover maps of those coefficients and separate contributions that are mixed in an energy-integrated measurement.

SignificanceThe work established the basis representation used for material decomposition in dual- and multienergy CT. Later spectral imaging research uses this representation to distinguish materials whose attenuation can appear similar on a conventional energy-integrating image.

Key1977Journal of Computer Assisted Tomography155 citations

Display of Three-Dimensional Information in Computed Tomography

G. T. Herman, H. K. Liu

The authors assembled transverse CT slices into a three-dimensional array and developed software to display a section through that array in an arbitrary orientation. They also demonstrated how to detect an organ boundary and display the isolated structure as a surface.

SignificanceThe study showed that one CT volume could be resampled outside the acquired orientation and also used to depict an organ surface. Both capabilities became functions of subsequent medical workstations for multiplanar reformatting and surface display.

Key1979Computer Graphics and Image Processing468 citations

Three-dimensional display of human organs from computed tomograms

Gabor T. Herman, Hsun Kao Liu

The authors approximated organ surfaces from CT with small square faces of restricted orientation and adapted a depth buffer to remove hidden surfaces efficiently. They applied low-pass filtering to reduce artifacts from the square approximation and demonstrated the method with actual patient-derived organ volumes.

SignificanceThe work showed that voxel boundaries could be rendered as visible faces for three-dimensional inspection of organs imaged by CT. Drebin and colleagues later described this square-face model when comparing existing surface methods with direct volume rendering.

Landmark1981Medical Physics488 citations

A method for describing the doses delivered by transmission x-ray computed tomography

Thomas B. Shope, Robert M. Gagne, Gordon C. Johnson

Shope and colleagues proposed deriving a dose descriptor for a series of contiguous CT sections from a single-scan dose profile. They integrated the profile along the scan axis and tested the estimate at different phantom positions and for different numbers of scans using five types of scanner.

SignificanceThe work introduced the CT dose index as a reproducible descriptor of scanner output. The FDA subsequently adopted the quantity, and modern ICRP guidance uses its volumetric form in setting and assessing diagnostic reference levels for CT.

Landmark1984Journal of the Optical Society of America A7,216 citations

Practical cone-beam algorithm

L. A. Feldkamp, L. C. Davis, J. W. Kress

Feldkamp, Davis, and Kress derived an approximate three-dimensional reconstruction from two-dimensional cone-beam projections along a circular trajectory. Their method uses convolution and back-projection, reduces to fan-beam reconstruction in the central plane, and was demonstrated using projections calculated from a mathematical phantom.

SignificanceThe FDK algorithm extended filtered back-projection to practical cone-beam volumes. Its computational form became a standard analytical baseline for circular cone-beam CT, including comparisons that test artifact suppression and image recovery with limited angular sampling.

Key1984Radiology497 citations

Three dimensional CT reconstruction images for craniofacial surgical planning and evaluation

M. W. Vannier, J. L. Marsh, J. O. Warren

The authors reconstructed three-dimensional bone and soft tissue surfaces from high-resolution CT contours and adapted computer-aided design methods to complex craniofacial cases. They showed how those surfaces could delineate abnormal anatomy, support surgical planning, and assist quantitative evaluation after surgery.

SignificanceThe work brought CT-derived surface models into preoperative and postoperative craniofacial assessment. Follow-up studies showed how clinicians could view skull reconstructions from different directions and selectively hide structures to inspect anatomical relationships obscured in an external view.

Landmark1986IEEE Transactions on Medical Imaging1,003 citations

On the Determination of Functions from Their Integral Values along Certain Manifolds

Johann Radon

In the work first published in 1917, Radon integrated a function of two variables along straight lines in the plane. He proved that the resulting line integrals determine the original function under suitable regularity conditions and derived a formula to recover it. This record is for the published English translation.

SignificanceRadon inversion gives the mathematical basis for recovering a distribution from projections. In an ideal monoenergetic, parallel-beam CT system, the negative logarithm of the transmission fraction gives the line integrals of attenuation. This relation connects the scanner's measurements to the map it reconstructs.

Key1990Radiology1,612 citations

Adverse reactions to ionic and nonionic contrast media. A report from the Japanese Committee on the Safety of Contrast Media.

H. Katayama, K. Yamaguchi, T. Kozuka, T. Takashima, P. Seez, K. Matsuura

This prospective nationwide comparison in Japan recorded adverse reactions in 337,647 contrast examinations. Reactions were less frequent with low-osmolar nonionic agents than with high-osmolar ionic agents. Severe reactions occurred in 0.04% of examinations using nonionic agents and in 0.22% of those using ionic agents.

SignificanceThe size of the study allowed a comparison of uncommon severe reactions across contrast formulations and supported the move toward low-osmolar agents. The American College of Radiology cites the study in its contrast media manual when discussing acute reactions.

Landmark1990Radiology1,159 citations

Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation

W. A. Kalender, W. Seissler, E. Klotz, P. Vock

The investigators combined continuous gantry rotation with controlled continuous table motion, producing a helical acquisition. They interpolated the measurements to reconstruct sections at positions chosen after scanning. Clinical examples included lung nodules and contrast-enhanced studies acquired with single-breath-hold volume coverage.

SignificanceHelical acquisition made it possible to cover an organ continuously in one breath hold and choose reconstruction levels afterward. Subsequent multidetector systems retained helical sampling while increasing the volume covered per gantry rotation and the speed of each examination.

Followed byHu 2000

Key1995NIST2,156 citations

Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients 1 keV to 20 MeV for Elements Z = 1 to 92 and 48 Additional Substances of Dosimetric Interest

J. H. Hubbell, S. M. Seltzer

The NIST report compiled photon mass attenuation and mass energy-absorption coefficients over energies from 1 keV to 20 MeV. The tables and graphs cover elements with atomic numbers 1 through 92 and 48 additional substances and mixtures relevant to dosimetry.

SignificanceThe compilation extended Hubbell's earlier reference tables and was subsequently made available as NIST Standard Reference Database 126. It provides consistent material data for comparing tissue attenuation, calculating photon penetration in shielding, and estimating energy deposition in dosimetry.

Key1996IEEE Transactions on Nuclear Science196 citations

Attenuation correction of SPECT using X-ray CT on an emission-transmission CT system: myocardial perfusion assessment

S. C. Blankespoor, X. Xu, K. Kalki, J. K. Brown, H. R. Tang … B. H. Hasegawa

The researchers registered data from juxtaposed CT and SPECT scanners and converted the CT measurements to attenuation maps at 140 keV. Attenuation correction reduced underestimation of myocardial activity in a torso phantom and in pigs. An additional partial-volume correction improved agreement with tissue samples in pigs but overestimated activity in the phantom.

SignificanceThis study quantified the benefit and limitations of using registered CT data for attenuation correction on a combined emission–transmission system. UCSF traces its human-scale SPECT/CT prototype for clinical research to the group's work on registered emission and transmission imaging.

Key1998Medical Physics1,081 citations

Attenuation correction for a combined 3D PET/CT scanner

P. E. Kinahan, D. W. Townsend, T. Beyer, D. Sashin

The authors tested whether a registered CT image could supply an attenuation map for 511 keV PET photons. Using bone and soft-tissue phantoms and human scans, they compared conversion methods and demonstrated a hybrid mapping from CT attenuation to PET attenuation.

SignificanceThe proof of principle gave CT a quantitative function in hybrid imaging alongside anatomical localization. The first reported clinical PET/CT prototype incorporated CT-derived correction, allowing combined scans to use the CT data in place of a separate PET transmission acquisition.

Followed byBeyer 2000

Key1999The New England Journal of Medicine814 citations

A Comparison of Virtual and Conventional Colonoscopy for the Detection of Colorectal Polyps

Helen M. Fenlon, David P. Nunes, Paul C. Schroy III, Matthew A. Barish, Peter D. Clarke, Joseph T. Ferrucci

In a prospective study of 100 patients at high risk of colorectal neoplasia, the investigators reconstructed endoluminal views from helical CT and compared the findings with conventional colonoscopy in the same patients. The virtual examination detected a greater proportion of larger polyps than of smaller ones.

SignificanceComparing CT endoluminal display with conventional colonoscopy in the same patients moved virtual endoscopy from feasibility testing to clinical assessment by lesion size. Subsequent research extended the evaluation from a high-risk study population to asymptomatic people undergoing screening.

Landmark2000Journal of Nuclear Medicine1,977 citations

A Combined PET/CT Scanner for Clinical Oncology

Thomas Beyer, David W. Townsend, Tony Brun, Paul E. Kinahan, Martin Charron, Raymond Roddy

The prototype mounted a spiral CT scanner and a rotating PET scanner on a common gantry and acquired both studies using the same patient support. The CT data supplied localization and correction information for PET. The report described scanner performance and experience imaging more than 110 patients with cancer.

SignificanceThe prototype made it possible to localize metabolic findings against anatomy acquired during the same examination. Clinical evaluation began in 1998. The first commercial PET/CT system entered clinical use in 2001 and the combined modality subsequently became common in oncology.

Builds onKinahan 1998, Hudson 1994

Key2000Radiology561 citations

Four Multidetector-Row Helical CT: Image Quality and Volume Coverage Speed

Hui Hu, H. David He, W. Dennis Foley, Stanley H. Fox

This study compared four- and single-detector-row helical CT using phantom measurements, models, and ratings of clinical images. The investigators measured section profiles, noise, and artifacts. The four-row system achieved two to three times the volume coverage speed at comparable diagnostic image quality.

SignificanceThe comparison provided an early quantitative baseline for the advantages of acquiring several detector rows together. Subsequent multidetector systems extended the same approach to faster coverage of organs while preserving thin sections for multiplanar reformats.

Builds onKalender 1990

Key2002IEEE Visualization 2002214 citations

CPR - Curved Planar Reformation

Armin Kanitsar, Dominik Fleischmann, Rainer Wegenkittl, Petr Felkel, Meister Eduard Gröller

The authors resampled CT volumes along a vessel centerline to display the lumen, wall, and surrounding tissue of a curved vessel in one image. They compared three reformations using a scanned tube phantom and presented thick, rotating, and multipath variants.

SignificanceThe study made explicit how curved reformations display long vessel segments within a single view and how the chosen method changes the representation of length, orientation, and branches. A subsequent paper extended multipath reformation to display an entire vascular tree.

Key2002IEEE Transactions on Medical Imaging757 citations

Statistical image reconstruction for polyenergetic X-ray computed tomography

I. A. Elbakri, J. A. Fessler

The authors incorporated the source spectrum and energy-dependent attenuation into a statistical CT model. They estimated voxel densities using penalized likelihood and an ordered-subsets algorithm. In simulated measurements of objects containing bone and soft tissue, the reconstruction reduced beam-hardening artifacts.

SignificanceThe work demonstrated how statistical reconstruction can account for beam-hardening physics within the forward model. It is a reference for later model-based CT approaches that incorporate the physics of the transmission measurements into the image estimate itself.

Key2003The New England Journal of Medicine2,123 citations

Computed Tomographic Virtual Colonoscopy to Screen for Colorectal Neoplasia in Asymptomatic Adults

Perry J. Pickhardt, J. Richard Choi, Inku Hwang, James A. Butler, Michael L. Puckett, Hans A. Hildebrandt

The researchers examined 1,233 asymptomatic adults with virtual and optical colonoscopy on the same day. CT readers initially searched a three-dimensional endoluminal display for polyps. With final optical findings after segmental unblinding as the reference, CT colonography had a per-patient sensitivity of 93.8% for adenomatous polyps at least 10 mm in diameter.

SignificanceThe study provided screening data for CT colonography using a primary three-dimensional reading method in asymptomatic adults. Later multicenter validation also studied performance by lesion size, providing independent evidence for assessing the technique's use in screening.

Key2005Medical Physics300 citations

Image reconstruction and image quality evaluation for a 64-slice CT scanner with z-flying focal spot

T. G. Flohr, K. Stierstorfer, S. Ulzheimer, H. Bruder, A. N. Primak, C. H. McCollough

A CT scanner alternated its focal spot between two longitudinal positions, interleaving the samples from 32 detector rows to acquire 64 overlapping sections per rotation. The study measured longitudinal resolution, section profiles, and noise and evaluated helical image quality using phantom and patient scans.

SignificanceThe scanner demonstrated that geometry could increase longitudinal sampling density beyond the physical detector row count. The technique was implemented in a commercial 64-section system, supporting thin-section volume acquisitions and reformats through the resulting data in multiple planes.

Landmark2006European Radiology1,545 citations

First performance evaluation of a dual-source CT (DSCT) system

Thomas G. Flohr, Cynthia H. McCollough, Herbert Bruder, Martin Petersilka, Klaus Gruber, Christoph Süß

This evaluation measured the performance of a scanner with two X-ray tubes and two detector systems offset by approximately a right angle. Electrocardiogram-gated single-segment reconstruction achieved an 83 ms temporal resolution. Acquiring data at two tube voltages also let the authors separate bone from iodine-filled vessels.

SignificanceThe geometry reduced the time interval represented by a cardiac section, addressing motion in coronary imaging. Subsequent commercial systems retained dual sources for fast cardiac acquisitions and also used the two tubes to collect data at different spectra for dual-energy CT.

Key2006RadioGraphics396 citations

Volume Rendering versus Maximum Intensity Projection in CT Angiography: What Works Best, When, and Why

Elliot K. Fishman, Derek R. Ney, David G. Heath, Frank M. Corl, Karen M. Horton, Pamela T. Johnson

The authors compared maximum intensity projection and volume rendering for CT angiography. Clinical images illustrated what each display preserves and how superimposed structures or rendering choices can affect interpretation. They related the strengths and limitations of the displays to specific clinical tasks.

SignificanceThe review connected algorithmic differences to clinical decisions about displaying CT angiograms. It offered a reference for postprocessing multidetector CT volumes, distinguishing tasks that benefit from emphasizing high-attenuation vessels from those that require surrounding anatomy and depth cues.

Key2007Medical Physics1,028 citations

A three-dimensional statistical approach to improved image quality for multislice helical CT

Jean-Baptiste Thibault, Ken D. Sauer, Charles A. Bouman, Jiang Hsieh

The method used a three-dimensional forward model of multislice helical acquisition, statistical weighting of measurements, and a prior on the image. Phantom tests demonstrated improved resolution and lower noise alongside reduced helical cone-beam artifacts. Reconstructions of patient scans illustrated clinical image appearance.

SignificanceThe work demonstrated model-based iterative reconstruction on real multislice helical CT data. Later evaluations of commercial model-based reconstruction cite this study when examining how spatial resolution and image noise vary with exposure and reconstruction settings.

Landmark2007Annals of the ICRP

The 2007 Recommendations of the International Commission on Radiological Protection

International Commission on Radiological Protection

The Commission revised the radiation and tissue weights used for equivalent and effective dose and defined planned, emergency, and existing exposure situations. It applied justification and optimization across all three situations and specified individual dose limits for occupational and public exposure in planned situations.

SignificanceThe recommendations supplied the framework used in the IAEA International Basic Safety Standards. Those standards apply the principles of justification and optimization to medical exposures and assign responsibilities for implementing them in diagnostic and interventional imaging.

Followed byProtection 2023

Key2008Physics in Medicine & Biology2,229 citations

Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization

Emil Y. Sidky, Xiaochuan Pan

The algorithm minimized image total variation while enforcing nonnegativity and requiring the calculated projections to agree with the data within a tolerance. It combined adaptive steepest descent with projection onto convex sets and was tested on simulated cone-beam data from disk and jaw phantoms.

SignificanceThe paper became a widely cited baseline for sparse-view CT, separating the allowed projection error from the total variation penalty. The same group subsequently extended the framework to measured low-intensity X-ray projections and tested it under reduced-exposure conditions.

Landmark2011New England Journal of Medicine12,304 citations

Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening

National Lung Screening Trial Research Team

At 33 centers, the National Lung Screening Trial randomly assigned high-risk participants to three annual rounds of low-dose CT or single-view chest radiography. Lung cancer mortality was 20% lower in the CT group. That group also had more positive screening results, most of which were false positives.

SignificanceThe trial showed that the evaluation of low-dose CT screening could measure lung cancer deaths along with detection and false-positive results. The US Preventive Services Task Force included NLST in its evidence for lung cancer screening recommendations.

Key2012The Lancet4,240 citations

Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study

Mark S. Pearce, Jane A. Salotti, Mark P. Little, Kieran McHugh, Choonsik Lee, Kwang Pyo Kim

The authors followed a retrospective cohort of children and young adults examined by CT in Great Britain. They estimated cumulative absorbed doses to red bone marrow and the brain and used cancer registry data to assess subsequent disease. Estimated doses were positively associated with leukemia and brain tumor incidence.

SignificanceThe study supplied direct epidemiologic evidence linking reconstructed organ doses from childhood CT with later cancer incidence. The National Cancer Institute cites the results in its discussion of pediatric CT radiation, including the need to optimize exposure.

Key2014The New England Journal of Medicine748 citations

Ultrasonography versus Computed Tomography for Suspected Nephrolithiasis

Rebecca Smith-Bindman, Chandra Aubin, John Bailitz, Rimon N. Bengiamin, Carlos A. Camargo Jr., Jill Corbo

This multicenter trial randomly assigned 2,759 patients with suspected kidney stones to point-of-care ultrasound, radiology ultrasound, or CT as the initial study. The ultrasound groups had lower cumulative radiation exposure over six months, with no significant difference in high-risk diagnoses with complications within 30 days.

SignificanceThe trial compared initial imaging strategies using patient outcomes and cumulative radiation exposure, while allowing additional imaging at the treating physician's discretion. It provided comparative evidence for starting with ultrasound in selected emergency patients with suspected kidney stones.

Key2016Radiology223 citations

Abdominal Imaging with Contrast-enhanced Photon-counting CT: First Human Experience

Amir Pourmorteza, Rolf Symons, Veit Sandfort, Marissa Mallek, Matthew K. Fuld, Gregory Henderson

Fifteen asymptomatic volunteers underwent paired, dose-matched contrast-enhanced abdominal CT scans with a photon-counting prototype and an energy-integrating detector. Readers gave the two methods similar scores for image quality, noise, and artifacts. Iodine maps generated from the photon-counting data improved the contrast-to-noise ratio for enhanced kidney tissue in the reported comparison.

SignificanceThis paired study established the feasibility of conventional contrast-enhanced abdominal imaging with a photon-counting prototype while demonstrating spectral iodine mapping from the same acquisition. The group subsequently extended abdominal material decomposition to distinguish two contrast agents in an in vivo animal study.

Key2017American Journal of Roentgenology243 citations

Cinematic Rendering in CT: A Novel, Lifelike 3D Visualization Technique

Marwen Eid, Carlo N. De Cecco, John W. Nance Jr., Damiano Caruso, Moritz H. Albrecht, Adam J. Spandorfer

The article explained how cinematic rendering applies global illumination to CT volumes by modeling light propagation, absorption, and scattering. Side-by-side images of an intracranial aneurysm and an aortic stent illustrated how shading changes the cues to the depth and shape of anatomical structures.

SignificanceThe pictorial review provided an early reference for applying global illumination to clinical CT display. Brookmeyer and colleagues cited the article in their 2024 review of implementation, which described how cinematic rendering fits into postprocessing and preprocedural planning.

Landmark2017IEEE Transactions on Image Processing2,968 citations

Deep Convolutional Neural Network for Inverse Problems in Imaging

Kyong Hwan Jin, Michael T. McCann, Emmanuel Froustey, Michael Unser

FBPConvNet first applied filtered back-projection to sparse-view CT data, then used a multiresolution residual convolutional network to remove artifacts in the initial image. The authors tested synthetic phantoms and real experimental sinograms. On their more realistic phantoms, it outperformed a total-variation reconstruction baseline.

SignificanceThe paper provided a prominent baseline for combining a conventional inverse with learned artifact correction. The Learned Primal-Dual study later used learned post-processing of filtered back-projection as a comparator for a network that instead placed the measurement operator inside the reconstruction.

Key2017Annals of the ICRP1,338 citations

ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging

E. Vañó, D. L. Miller, C. J. Martin, M. M. Rehani, K. Kang, M. Rosenstein

The Commission clarified which quantities to use for diagnostic reference levels, how to survey practices, and when to update benchmark values. It extended practical guidance to interventional procedures, pediatric imaging, and newer technologies and discussed how automated dose reporting could support periodic comparisons.

SignificanceThe report turns optimization into a process that can be audited across facilities using comparable examinations. The IAEA uses the diagnostic reference level approach in its implementation guidance to identify protocols whose higher typical doses warrant investigation.

Key2017Medical Physics425 citations

Low-dose CT for the detection and classification of metastatic liver lesions: Results of the 2016 Low Dose CT Grand Challenge

Cynthia H. McCollough, Adam C. Bartley, Rickey E. Carter, Baiyu Chen, Tammy A. Drees, Phillip Edwards

The Low Dose CT Grand Challenge supplied common contrast-enhanced CT cases to groups testing image-space denoising or iterative reconstruction. Participants reconstructed twenty quarter-dose test examinations. Eleven blinded readers marked liver metastases, with substantial differences in reader scores across the submitted reconstruction and denoising methods.

SignificanceThe competition tied reconstruction evaluation to the clinical task of detecting liver metastases. The Cancer Imaging Archive's larger collection includes 13 of the challenge test cases. A separate release provides all 30 training and test cases in the same standardized projection format for further comparisons.

Landmark2018IEEE Transactions on Medical Imaging1,136 citations

Learned Primal-Dual Reconstruction

Jonas Adler, Ozan Öktem

The method unrolled a primal-dual optimization algorithm and replaced the proximal operations with convolutional networks while retaining the forward imaging operator. It started from measured projection data. Low-dose CT phantom experiments reported gains over filtered back-projection, total variation, and learned post-processing of a conventional reconstruction.

SignificanceThe method supplied a reference implementation of an end-to-end tomographic reconstructor with explicit forward and adjoint operations. It remains a reference for studying how learned updates interact with measured projections and for comparing unrolled reconstruction with image-domain correction.

Key2018Radiology1,499 citations

Photon-counting CT: Technical Principles and Clinical Prospects

Martin J. Willemink, Mats Persson, Amir Pourmorteza, Norbert J. Pelc, Dominik Fleischmann

The review explains how photon-counting detectors register individual incoming X-rays and assign events using energy thresholds. It relates those detector properties to CT performance, including spatial resolution, image contrast, electronic noise, energy-resolved measurements, and potential clinical uses such as material separation.

SignificanceThis review connected detector design with measurable CT performance before commercial deployment. Rajendran and colleagues cited it in their technical evaluation of the first commercial photon-counting system and assessed spatial resolution, noise, and spectral quantitation on that scanner.

Landmark2019Journal of Nuclear Medicine778 citations

First Human Imaging Studies with the EXPLORER Total-Body PET Scanner

Ramsey D. Badawi, Hongcheng Shi, Pengcheng Hu, Shuguang Chen, Tianyi Xu, Patricia M. Price

This report presented initial human imaging with the EXPLORER PET/CT scanner. Its 194 cm axial field of view allowed activity to be recorded across the body at one bed position. Examples illustrated several ways of using the added sensitivity, including rapid, low-activity, delayed, and dynamic whole-body studies.

SignificanceSimultaneous coverage made it possible to observe tracer kinetics in multiple organs in the same time frame. Subsequent characterization of the instrument measured sensitivity, count-rate performance, and image quality, creating benchmarks for later long-axial-field systems.

Builds onCherry 2018

Key2020New England Journal of Medicine4,125 citations

Reduced Lung-Cancer Mortality with Volume CT Screening in a Randomized Trial

Harry J. de Koning, Carlijn M. van der Aalst, Pim A. de Jong, Ernst T. Scholten, Kristiaan Nackaerts, Marjolein A. Heuvelmans

NELSON randomly assigned 13,195 men in the primary analysis to low-dose CT screening or no screening. Another 2,594 women were included in subgroup analyses. The trial used nodule volumes and growth to guide follow-up. At 10 years the male lung-cancer mortality rate ratio was 0.76, with a 95% confidence interval of 0.61 to 0.94.

SignificanceNELSON supplied randomized mortality evidence for a screening program that used volumetric nodule management and a no-screening control. The US Preventive Services Task Force evidence review identified NELSON and the US National Lung Screening Trial as the two adequately powered trials for lung-cancer mortality.

Notable2021IEEE Transactions on Medical Imaging184 citations

Deep Sinogram Completion With Image Prior for Metal Artifact Reduction in CT Images

Lequan Yu, Zhicheng Zhang, Xiaomeng Li, Lei Xing

The method produced an image prior and projected it forward differentiably to guide a second network that repaired metal-corrupted sinogram values. Filtered back-projection yielded the final image. Experiments with simulated and real artifacts examined projection continuity around metal traces and reported reduced artifacts relative to the comparison methods.

SignificanceThe paper showed how an estimated image could guide a projection-space correction and how that correction could be tested on both simulated and real artifacts. The differentiable forward operator allowed the prior-image and sinogram networks to be optimized jointly.

Key2021Journal of Nuclear Medicine449 citations

Performance Evaluation of the uEXPLORER Total-Body PET/CT Scanner Based on NEMA NU 2-2018 with Additional Tests to Characterize PET Scanners with a Long Axial Field of View

Benjamin A. Spencer, Eric Berg, Jeffrey P. Schmall, Negar Omidvari, Edwin K. Leung, Yasser G. Abdelhafez

The authors evaluated the 194 cm uEXPLORER using standard NEMA tests and extended phantoms for sensitivity and count-rate measurements. They also assessed image quality at several axial positions. Centered-source sensitivity was 174 thousand counts per second per megabecquerel with the standard line source and 147 thousand with a 170 cm line source.

SignificanceThe tests supplied reproducible performance benchmarks for the long-axial-field scanner behind the initial human images. They also documented how standard and human-length phantoms differed in key measurements. Subsequent Monte Carlo work used these data to validate simulated scanner sensitivity and count-rate performance.

Landmark2022Radiology652 citations

First Clinical Photon-counting Detector CT System: Technical Evaluation

Kishore Rajendran, Martin Petersilka, André Henning, Elisabeth R. Shanblatt, Bernhard Schmidt, Thomas G. Flohr

The authors characterized a clinical dual-source photon-counting CT scanner with phantom measurements and example examinations from four participants. They measured spatial resolution, noise, section response, and iodine quantitation. The high-resolution configuration achieved a maximum measured in-plane resolution of 125 micrometers.

SignificanceThe evaluation documented performance at the clinical introduction of a commercial photon-counting CT system. A contemporaneous technical baseline for high-resolution imaging and spectral quantitation allowed later assessments, including the Radiology milestones review, to compare these capabilities with earlier CT technology.

Key2023Radiology528 citations

Deep Learning Image Reconstruction for CT: Technical Principles and Clinical Prospects

Lennart R. Koetzier, Domenico Mastrodicasa, Timothy P. Szczykutowicz, Niels R. van der Werf, Adam S. Wang, Veit Sandfort

The review traced clinical CT reconstruction from filtered back-projection through iterative and learned methods. It described commercial training targets and summarized evidence for noise texture, spatial resolution, and dose reduction across applications. It also examined metal artifact reduction and prospective uses in photon-counting CT.

SignificanceThe review assembled early clinical evidence for scanner-integrated deep learning reconstruction and explained why different training targets can yield different image properties. It provides a reference for tracing commercial implementations to their underlying studies and for comparing results across protocols and clinical tasks.

Key2023Annals of the ICRP59 citations

Optimisation of Radiological Protection in Digital Radiology Techniques for Medical Imaging

International Commission on Radiological Protection

The Commission describes how to optimize protection in digital radiography, fluoroscopy, and CT while preserving image quality adequate for the clinical task. It proposes four levels for facilities to assess their practices, covering equipment selection and monitoring, protocol review, staff training, and collaboration across professions.

SignificancePublication 154 gives digital imaging departments a way to assess their implementation of the Commission's optimization principle in stages. The task group's companion strategy describes how departments can use professional roles, technical capability, and management processes to identify their next steps.

Builds onProtection 2007

Key2023Nature Medicine412 citations

Risk of hematological malignancies from CT radiation exposure in children, adolescents and young adults

Magda Bosch de Basea, Isabelle Thierry-Chef, Richard Harbron, Michael Hauptmann, Graham Byrnes, Maria-Odile Bernier

EPI-CT followed 948,174 people in nine European countries who underwent CT before age 22. The researchers reconstructed active bone marrow dose from examination and scanner information. Cumulative dose was associated with hematologic malignancies, with an excess relative risk of 1.96 per 100 mGy and a 95% confidence interval of 1.10 to 3.12.

SignificanceThe study provided a multinational reference estimate for hematologic malignancy following CT in young people by applying a common organ-dose method. The subsequent North American RIC cohort study explicitly compared the two cohorts' risk estimates at 100 mGy.

Notable2025ICCV 202528 citations

Medical World Model

Yijun Yang, Zhao-Yang Wang, Qiuping Liu, Shuwen Sun, Kang Wang, Rama Chellappa

MeWM generates CT images of a liver tumor after transarterial chemoembolization using pretreatment imaging and treatment records. It was evaluated retrospectively on paired scans and on a held-out subset after fine-tuning on a public dataset. Three radiologists judged whether post-treatment images were real or synthetic.

SignificanceThe study makes a recorded intervention an input to CT simulation and evaluates the appearance of synthesized tumors against observed scans and radiologist judgments. Estimating how an individual would respond to an unchosen regimen requires separate evidence.

Notable2026FDA 510(k) K252970

BriefCase-Triage: CARE Multi-triage CT Body

Aidoc Medical, Ltd.

This software uses a locked algorithm fine-tuned from a foundation model. It processes contrast and noncontrast chest, abdominal, or pelvic CT for people aged 18 and older. It flags 11 specified suspected findings for trained readers to prioritize review of the original exam. The FDA cleared the device in January 2026.

SignificanceThe case shows how a pretrained foundation model can supply several specified triage functions in one device. The public clearance record specifies the scans, the listed findings, and the notification role, defining the scope of the application.

Key2026Nature273 citations

Merlin: a computed tomography vision–language foundation model and dataset

Louis Blankemeier, Ashwin Kumar, Joseph Paul Cohen, Jiaming Liu, Longchao Liu, Dave Van Veen

Merlin learned a volumetric representation from 15,331 abdominal CT examinations, their radiology reports, and diagnosis codes. Tasks included retrieving the findings or impression section of a report from a CT volume, classifying imaging findings, and segmentation after adaptation. The external evaluation covered 44,098 exams in total from three sites and two public datasets, with different sample sizes by task.

SignificanceThe study combined routinely recorded clinical information with full 3D scans for pretraining and evaluated transfer across several independent sources. The reported task-level results give later abdominal CT models a reference for assessing how three-dimensional representations transfer.