Nuclear medicine and molecular imaging

In the exhibits5.1 The tracer principle5.2 Radioactive decay and half-life5.3 The gamma camera and SPECT5.4 Positron emission tomography (PET)5.5 FDG and imaging of glucose metabolism8.5 Scanner advances: multidetector CT, PET/CT and 3 T MRI9.4 Dual-source CT, tomosynthesis and PET/MR

Landmark1923Biochemical Journal297 citations

The Absorption and Translocation of Lead by Plants: A Contribution to the Application of the Method of Radioactive Indicators in the Investigation of the Change of Substance in Plants

George Hevesy

Hevesy exposed plants to a solution containing a radioactive isotope of lead and measured radioactivity in the ash from different parts of the plants. These measurements let him estimate how much lead the plants took up and how it was distributed.

SignificanceThis experiment demonstrated that an isotope could track the distribution of a substance in a living system. Hevesy received the 1943 Nobel Prize in Chemistry for the use of isotopes as tracers, the principle underlying nuclear medicine imaging.

Landmark1933Physical Review1,351 citations

The Positive Electron

Carl D. Anderson

Anderson studied cosmic-ray tracks in a magnetic cloud chamber. From curvature, ionization, and energy loss across a lead plate, he identified tracks consistent with a positive unit charge and a mass far smaller than a proton's. He called the particles positrons.

SignificanceAnderson received the 1936 Nobel Prize in Physics for discovering the positron. Later PET scanners used the paired photons produced by positron annihilation to assign coincident events to lines of response without a mechanical collimator.

Key1955JAMA94 citations

Localization of Intracranial Lesions by Scanning with Positron-Emitting Arsenic

William H. Sweet, Gordon L. Brownell

Sweet and Brownell examined intracranial lesions using a positron-emitting arsenic tracer and opposed detectors operating in coincidence. They used the spatial pattern of counts to localize abnormal uptake and illustrated how external measurements could inform the localization of lesions inside the head.

SignificanceThe clinical series showed that positron coincidence measurements could be made in patients and used for lesion localization. Tomographic PET later used coincidences collected from many more angles to reconstruct the internal activity distribution in cross-section.

Landmark1958Review of Scientific Instruments1,109 citations

Scintillation Camera

Hal O. Anger

Anger combined a pinhole shield with a scintillation crystal viewed by seven photomultiplier tubes. The detector used their signals to estimate where each flash occurred and selected events by pulse height. Accumulating the displayed positions formed an image of the radioactive source.

SignificancePosition-sensitive readout of one large scintillation crystal made practical planar gamma cameras possible. Rotating versions of the camera later acquired projections at multiple angles for SPECT, carrying the design into clinical emission tomography in nuclear medicine.

Landmark1963Radiology540 citations

Image Separation Radioisotope Scanning

David E. Kuhl, Roy Q. Edwards

Kuhl and Edwards sought to separate radioactive sources at different depths that appeared superimposed on a conventional scan. They adapted ideas from section radiography, recording counts from multiple directions and superimposing the resulting signals on film. The experiment separated radioactive sources located in different sections of a test phantom.

SignificanceThe experiments established that measured emissions could form a transverse section. Later histories identify them as early demonstrations of SPECT. Rotating gamma cameras subsequently used the same multiview principle to reconstruct clinical sections with computers.

Landmark1963Journal of Applied Physics1,737 citations

Representation of a Function by Its Line Integrals, with Some Radiological Applications

A. M. Cormack

Cormack derived a way to recover a function on a finite region from the integrals along the lines that intersect it. He formulated applications to X-ray attenuation, positron annihilation distributions, and density estimation using the energy loss of charged particles.

SignificanceCormack formulated projection inversion as a problem in radiological physics. The 1979 Nobel Prize in Physiology or Medicine jointly recognized Cormack's theoretical contributions to reconstruction and Hounsfield's independent development of a practical computerized X-ray scanner.

Followed byCormack 1964

Key1964Nucleonics108 citations

Optimization of a Scanning Method Using Tc-99m

P. V. Harper, R. Beck, D. Charleston, K. A. Lathrop

Harper and colleagues examined how to use technetium-99m for radioisotope scanning. They considered biological uptake and localization together with radiation dose, photon energy, and collimation. The report illustrated scans including thyroid and liver studies as examples of the tracer's diagnostic use.

SignificanceThe paper demonstrated early clinical applications of technetium-99m scanning. Its favorable photon energy for gamma cameras and access to short-lived activity through hospital generators helped make technetium-99m a widely used label for tracers in routine single-photon imaging.

Landmark1975Radiology1,158 citations

A Positron-Emission Transaxial Tomograph for Nuclear Imaging (PETT)

Michel M. Ter-Pogossian, Michael E. Phelps, Edward J. Hoffman, Nizar A. Mullani

The PETT combined a hexagonal array of 24 sodium iodide detectors with coincidence electronics and computerized cross-sectional reconstruction. Simulations, phantoms, and animal studies were used to evaluate its ability to recover tracer activity and compare its contrast and resolution with scintillation cameras.

SignificancePETT put multiangle coincidence measurement and computerized emission tomography into a single instrument. Later PET histories identify it as a precursor to clinical scanners that use detector rings and quantitative reconstruction to map tracer distributions.

Landmark1977Journal of Neurochemistry6,456 citations

The [14C]Deoxyglucose Method for the Measurement of Local Cerebral Glucose Utilization: Theory, Procedure, and Normal Values in the Conscious and Anesthetized Albino Rat

L. Sokoloff, M. Reivich, C. Kennedy, M. H. Des Rosiers, C. S. Patlak … M. Shinohara

The study combined arterial sampling, quantitative autoradiography of brain sections, and a kinetic equation to estimate local glucose utilization from carbon-14 deoxyglucose in rats. The estimates were higher in gray matter than in white matter in awake animals. Thiopental anesthesia reduced rates throughout the brain, especially in gray matter.

SignificanceThe method made quantitative maps of regional glucose utilization possible from tracer uptake and arterial measurements. Reivich and colleagues explicitly based their 1979 human fluorodeoxyglucose method on this model, substituting fluorine-18 FDG and emission tomography for the carbon-14 autoradiography measurement.

Followed byReivich 1979

Landmark1978Journal of Labelled Compounds and Radiopharmaceuticals579 citations

Labeled 2-deoxy-D-glucose analogs. ¹⁸F-labeled 2-deoxy-2-fluoro-D-glucose, 2-deoxy-2-fluoro-D-mannose and ¹⁴C-2-deoxy-2-fluoro-D-glucose

T. Ido, C.-N. Wan, V. Casella, J. S. Fowler, A. P. Wolf … D. E. Kuhl

The study described preparation of several radiolabeled deoxyglucose analogues, including fluorine-18 FDG and the corresponding mannose analogue. The investigators prepared these compounds to support measurement of local cerebral glucose metabolism with labeled substrates, including a glucose analogue detectable through positron emission.

SignificanceThe radiochemical work supplied FDG for the Brookhaven and University of Pennsylvania collaboration on human brain metabolism. Subsequent human studies used the tracer for quantitative imaging, and FDG later became a standard tracer in oncologic PET.

Followed byReivich 1979

Landmark1979Circulation Research1,368 citations

The [18F]fluorodeoxyglucose method for the measurement of local cerebral glucose utilization in man

M. Reivich, D. Kuhl, A. Wolf, J. Greenberg, M. Phelps, T. Ido

Reivich and colleagues combined arterial activity measurements with brain emission tomography after injection of fluorine-18 FDG. Their kinetic model used FDG as a tracer for glucose exchange between plasma and brain and for phosphorylation in tissue. They used the method to estimate regional glucose utilization in two healthy volunteers.

SignificanceThe study brought fluorine-18 FDG into quantitative human imaging and made regional brain metabolism accessible in vivo. Later work tested and refined the kinetic model, while FDG imaging also became widely used for assessing tumor metabolism.

Builds onSokoloff 1977, Ido 1978

Key1979Physics in Medicine & Biology133 citations

Whole-body single-photon emission computed tomography using dual, large-field-of-view scintillation cameras

R. J. Jaszczak, Lee-Tzuu Chang, N. A. Stein, F. E. Moore

This system mounted two large-area scintillation cameras on a rotating gantry. It reconstructed multiple contiguous transverse sections from the projections collected in one continuous revolution. The implementation used weighted filtered back-projection, offered different collimators, and included a correction for photon attenuation.

SignificanceThe system showed that dual heads, continuous rotation, and simultaneous coverage of several sections could be combined in one instrument. Rotating gamma cameras subsequently became a standard implementation of SPECT and provided the emission component of hybrid SPECT/CT.

Landmark1982IEEE Transactions on Medical Imaging5,027 citations

Maximum Likelihood Reconstruction for Emission Tomography

L. A. Shepp, Y. Vardi

Shepp and Vardi modeled unobserved emissions as Poisson variables and specified the probabilities that emissions from each voxel would be registered by each detector. Their expectation-maximization algorithm iteratively estimated the underlying emission distribution by maximizing the likelihood of the measured counts.

SignificanceThe model brought counting statistics and detection probabilities directly into emission reconstruction. Maximum-likelihood expectation-maximization became a basis for iterative PET and SPECT, including subsequent ordered-subsets methods that sought to reduce the cost of reaching a useful image.

Followed byHudson 1994

Landmark1986IEEE Transactions on Nuclear Science553 citations

A Multicrystal Two Dimensional BGO Detector System for Positron Emission Tomography

M. E. Casey, R. Nutt

The authors coupled an array of bismuth germanate scintillation crystals to four photomultiplier tubes through a light guide. The electronics decoded the position of each event from the shared optical signals. This allowed a PET detector to identify individual crystals in two dimensions with a small number of readout channels.

SignificanceThe block detector let PET scanners use many small crystals without dedicating a photomultiplier to each crystal, making finer spatial sampling practical. The first commercial scanner based on detector blocks was installed at Hammersmith and could read out multiple transaxial planes.

Landmark1986IEEE Transactions on Medical Imaging1,003 citations

On the Determination of Functions from Their Integral Values along Certain Manifolds

Johann Radon

In the work first published in 1917, Radon integrated a function of two variables along straight lines in the plane. He proved that the resulting line integrals determine the original function under suitable regularity conditions and derived a formula to recover it. This record is for the published English translation.

SignificanceRadon inversion gives the mathematical basis for recovering a distribution from projections. In an ideal monoenergetic, parallel-beam CT system, the negative logarithm of the transmission fraction gives the line integrals of attenuation. This relation connects the scanner's measurements to the map it reconstructs.

Key1989IEEE Transactions on Medical Imaging198 citations

Three-dimensional display in nuclear medicine

J. W. Wallis, T. R. Miller, C. A. Lerner, E. C. Kleerup

The investigators compared several surface and volume display techniques for nuclear medicine data, including maximum-activity projection, which keeps the highest activity along each viewing ray. Scintigraphic examples illustrated how the different projections represented focal uptake and spatial relationships in the volume.

SignificanceMaximum-activity projection made prominent foci in a volume visible in a single projection. The same maximum-value operation became a display option for CT angiography, where it highlights structures with high attenuation, including vessels opacified with contrast material.

Landmark1994IEEE Transactions on Medical Imaging4,178 citations

Accelerated image reconstruction using ordered subsets of projection data

H. M. Hudson, R. S. Larkin

Hudson and Larkin split projection data into ordered subsets and used each subset to perform an expectation-maximization update before moving to the next. A full iteration visits every subset. This accelerated the early progress of image reconstruction in the experiments they reported.

SignificanceOrdered-subsets expectation-maximization reduced the time required to reach useful image quality, making statistical reconstruction more practical in clinical nuclear medicine. IAEA guidance identifies it as a commonly used reconstruction approach for quantitative PET examinations in clinical practice.

Builds onShepp 1982 Followed byBeyer 2000

Key1995NIST2,156 citations

Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients 1 keV to 20 MeV for Elements Z = 1 to 92 and 48 Additional Substances of Dosimetric Interest

J. H. Hubbell, S. M. Seltzer

The NIST report compiled photon mass attenuation and mass energy-absorption coefficients over energies from 1 keV to 20 MeV. The tables and graphs cover elements with atomic numbers 1 through 92 and 48 additional substances and mixtures relevant to dosimetry.

SignificanceThe compilation extended Hubbell's earlier reference tables and was subsequently made available as NIST Standard Reference Database 126. It provides consistent material data for comparing tissue attenuation, calculating photon penetration in shielding, and estimating energy deposition in dosimetry.

Key1996IEEE Transactions on Nuclear Science196 citations

Attenuation correction of SPECT using X-ray CT on an emission-transmission CT system: myocardial perfusion assessment

S. C. Blankespoor, X. Xu, K. Kalki, J. K. Brown, H. R. Tang … B. H. Hasegawa

The researchers registered data from juxtaposed CT and SPECT scanners and converted the CT measurements to attenuation maps at 140 keV. Attenuation correction reduced underestimation of myocardial activity in a torso phantom and in pigs. An additional partial-volume correction improved agreement with tissue samples in pigs but overestimated activity in the phantom.

SignificanceThis study quantified the benefit and limitations of using registered CT data for attenuation correction on a combined emission–transmission system. UCSF traces its human-scale SPECT/CT prototype for clinical research to the group's work on registered emission and transmission imaging.

Key1998Medical Physics1,081 citations

Attenuation correction for a combined 3D PET/CT scanner

P. E. Kinahan, D. W. Townsend, T. Beyer, D. Sashin

The authors tested whether a registered CT image could supply an attenuation map for 511 keV PET photons. Using bone and soft-tissue phantoms and human scans, they compared conversion methods and demonstrated a hybrid mapping from CT attenuation to PET attenuation.

SignificanceThe proof of principle gave CT a quantitative function in hybrid imaging alongside anatomical localization. The first reported clinical PET/CT prototype incorporated CT-derived correction, allowing combined scans to use the CT data in place of a separate PET transmission acquisition.

Followed byBeyer 2000

Key1999Physics in Medicine & Biology716 citations

Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution

C. S. Levin, E. J. Hoffman

The authors simulated positron trajectories for several radionuclides and estimated how displacement before annihilation contributes to image blur. They combined that contribution with detector element size and photon noncollinearity to assess achievable resolution for PET systems with different detector dimensions.

SignificanceThe analysis quantified the contributions of isotope physics and scanner geometry to PET resolution. It gives designers and evaluators a reference for judging how much finer detectors can improve resolution before other physical effects dominate.

Landmark2000Journal of Nuclear Medicine1,977 citations

A Combined PET/CT Scanner for Clinical Oncology

Thomas Beyer, David W. Townsend, Tony Brun, Paul E. Kinahan, Martin Charron, Raymond Roddy

The prototype mounted a spiral CT scanner and a rotating PET scanner on a common gantry and acquired both studies using the same patient support. The CT data supplied localization and correction information for PET. The report described scanner performance and experience imaging more than 110 patients with cancer.

SignificanceThe prototype made it possible to localize metabolic findings against anatomy acquired during the same examination. Clinical evaluation began in 1998. The first commercial PET/CT system entered clinical use in 2001 and the combined modality subsequently became common in oncology.

Builds onKinahan 1998, Hudson 1994

Key2004Physics in Medicine & Biology2,510 citations

GATE: a simulation toolkit for PET and SPECT

S. Jan, G. Santin, D. Strul, S. Staelens, K. Assié, D. Autret

GATE wrapped Geant4 in a scripted toolkit for simulating PET and SPECT measurements. It let users describe detector or source motion and tracer decay over time. The paper provided benchmark examples for installation and validation and discussed comparison with real scanners.

SignificanceA shared simulation toolkit made it possible for groups to compare detectors, acquisition protocols, and correction algorithms under specified conditions. The OpenGATE collaboration continued to maintain the toolkit and subsequently extended it to additional imaging and dosimetry applications.

Key2007Journal of Nuclear Medicine739 citations

Performance of Philips Gemini TF PET/CT Scanner with Special Consideration for Its Time-of-Flight Imaging Capabilities

Suleman Surti, Austin Kuhn, Matthew E. Werner, Amy E. Perkins, Jeffrey Kolthammer, Joel S. Karp

The study benchmarked the Gemini TF PET/CT scanner using standard and larger phantoms. Measurements covered count rates, spatial resolution, and coincidence timing. It also compared image reconstruction with and without timing information to assess contrast and noise for lesion-like objects.

SignificanceThe evaluation documented the first commercially available fully three-dimensional PET system with time-of-flight capability. The scanner provided a platform for subsequent phantom and patient studies that quantified how timing information changes lesion contrast and image noise.

Followed byZaidi 2011

Landmark2007Annals of the ICRP

The 2007 Recommendations of the International Commission on Radiological Protection

International Commission on Radiological Protection

The Commission revised the radiation and tissue weights used for equivalent and effective dose and defined planned, emergency, and existing exposure situations. It applied justification and optimization across all three situations and specified individual dose limits for occupational and public exposure in planned situations.

SignificanceThe recommendations supplied the framework used in the IAEA International Basic Safety Standards. Those standards apply the principles of justification and optimization to medical exposures and assign responsibilities for implementing them in diagnostic and interventional imaging.

Followed byProtection 2023

Key2009Journal of Nuclear Medicine4,103 citations

From RECIST to PERCIST: Evolving Considerations for PET Response Criteria in Solid Tumors

Richard L. Wahl, Heather Jacene, Yvette Kasamon, Martin A. Lodge

The paper reviewed anatomical and metabolic response assessment and proposed PERCIST 1.0 for solid tumors. It specified consistent imaging conditions and a reference tissue for comparing scans before and after systemic therapy. Peak lesion FDG uptake was normalized to lean body mass and measured in a small region of fixed volume.

SignificanceThe proposal supplied reproducible rules for evaluating metabolic response across treatment studies. EANM procedure guidelines cite PERCIST when discussing quantitative FDG assessment, and clinical studies have compared its response classifications with other established treatment response criteria.

Key2010European Journal of Nuclear Medicine and Molecular Imaging197 citations

Ultrafast nuclear myocardial perfusion imaging on a new gamma camera with semiconductor detector technique: first clinical validation

Ronny R. Buechel, Bernhard A. Herzog, Lars Husmann, Irene A. Burger, Aju P. Pazhenkottil, Valerie Treyer

Seventy-five consecutive patients underwent myocardial perfusion imaging with conventional dual-head SPECT and a dedicated cadmium–zinc–telluride camera. The new system acquired stress and rest scans in three and two minutes, respectively, compared with about 15 minutes each for conventional imaging. The patient-level agreement in clinical classification was 96.0%.

SignificanceThe paired clinical study quantified how much a dedicated semiconductor camera could shorten acquisitions while preserving agreement with conventional myocardial perfusion imaging. The EANM subsequently cited it as evidence in its procedure guideline for cardiac-centered gamma cameras.

Key2011Physics in Medicine & Biology439 citations

Design and performance evaluation of a whole-body Ingenuity TF PET–MRI system

H. Zaidi, N. Ojha, M. Morich, J. Griesmer, Z. Hu, P. Maniawski

This study evaluated a sequential whole-body system combining a time-of-flight PET scanner with 3 T MRI. The PET photomultipliers received magnetic shielding and the electronics were relocated to reduce mutual interference. Measurements characterized PET performance and the use of MR-derived attenuation maps.

SignificanceThe Philips sequential design retained photomultiplier-based PET detectors through shielding and physical separation. In their evaluation of the simultaneous Siemens scanner, Delso and colleagues discussed the Philips design as a contemporaneous clinical alternative. Their standardized phantom measurements characterized the Siemens scanner.

Builds onSurti 2007

Key2011Journal of Nuclear Medicine960 citations

Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR Scanner

Gaspar Delso, Sebastian Fürst, Björn Jakoby, Ralf Ladebeck, Carl Ganter … Sibylle I. Ziegler

Delso and colleagues measured an integrated whole-body PET/MR scanner while each subsystem operated independently and while both acquired data together. PET measurements included resolution, sensitivity, scatter, and count losses. MRI quality-control tests covered geometric accuracy and signal quality. The authors reported no perceptible effect on overall performance from integration under the conditions they tested.

SignificanceThe evaluation documented the first commercial integrated whole-body PET/MR scanner with simultaneous acquisition. Collecting emissions and MR data over the same period made it possible to investigate tracer behavior alongside MR measures of anatomy and function.

Key2015European Journal of Nuclear Medicine and Molecular Imaging3,675 citations

FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0

Ronald Boellaard, Roberto Delgado-Bolton, Wim J. G. Oyen, Francesco Giammarile, Klaus Tatsch, Wolfgang Eschner

The EANM updated its guidance for adult oncologic FDG PET/CT, covering preparation, acquisition, reconstruction, quality control, quantitation, and reporting. It specified procedures for repeatability on one scanner and for comparability across instruments and sites, including harmonization of quantitative performance across imaging centers.

SignificanceThe guideline specifies procedures and equipment checks for quantitative comparability. The EANM's EARL accreditation report documented implementation across about 200 scanners at 150 sites. Phantom measurements identified calibration errors, and corrective feedback brought participating scanners into compliance with the calibration specifications.

Key2017Annals of the ICRP1,338 citations

ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging

E. Vañó, D. L. Miller, C. J. Martin, M. M. Rehani, K. Kang, M. Rosenstein

The Commission clarified which quantities to use for diagnostic reference levels, how to survey practices, and when to update benchmark values. It extended practical guidance to interventional procedures, pediatric imaging, and newer technologies and discussed how automated dose reporting could support periodic comparisons.

SignificanceThe report turns optimization into a process that can be audited across facilities using comparable examinations. The IAEA uses the diagnostic reference level approach in its implementation guidance to identify protocols whose higher typical doses warrant investigation.

Key2018Journal of Nuclear Medicine827 citations

Total-Body PET: Maximizing Sensitivity to Create New Opportunities for Clinical Research and Patient Care

Simon R. Cherry, Terry Jones, Joel S. Karp, Jinyi Qi, William W. Moses, Ramsey D. Badawi

The authors reviewed geometric and timing improvements that could increase PET sensitivity. They estimated that extending axial coverage to the whole body could increase effective sensitivity about 40-fold for whole-body imaging and discussed the implications for scan duration, administered activity, and dynamic studies.

SignificanceThe article provided a quantitative rationale for a scanner with an extended axial field and distinguished the gains for whole-body imaging from those for a single organ. The EXPLORER system subsequently tested several of those opportunities in human imaging.

Followed byBadawi 2019

Landmark2019Journal of Nuclear Medicine778 citations

First Human Imaging Studies with the EXPLORER Total-Body PET Scanner

Ramsey D. Badawi, Hongcheng Shi, Pengcheng Hu, Shuguang Chen, Tianyi Xu, Patricia M. Price

This report presented initial human imaging with the EXPLORER PET/CT scanner. Its 194 cm axial field of view allowed activity to be recorded across the body at one bed position. Examples illustrated several ways of using the added sensitivity, including rapid, low-activity, delayed, and dynamic whole-body studies.

SignificanceSimultaneous coverage made it possible to observe tracer kinetics in multiple organs in the same time frame. Subsequent characterization of the instrument measured sensitivity, count-rate performance, and image quality, creating benchmarks for later long-axial-field systems.

Builds onCherry 2018

Key2020The Lancet2,306 citations

Prostate-specific membrane antigen PET-CT in patients with high-risk prostate cancer before curative-intent surgery or radiotherapy (proPSMA): a prospective, randomised, multicentre study

Michael S. Hofman, Nathan Lawrentschuk, Roslyn J. Francis, Colin Tang, Ian Vela, Paul Thomas

The Australian multicenter trial randomly assigned men with high-risk prostate cancer to initial staging using PSMA-targeted PET/CT or conventional CT and bone scanning. Against a prespecified reference standard, the targeted examination more accurately identified pelvic nodal or distant metastatic disease.

SignificanceThe trial supplied comparative evidence for a target-specific PET tracer in initial cancer staging. The joint EANM and SNMMI PSMA imaging procedure guideline cites the study in assessing evidence for staging patients with higher-risk disease.

Key2021Journal of Nuclear Medicine449 citations

Performance Evaluation of the uEXPLORER Total-Body PET/CT Scanner Based on NEMA NU 2-2018 with Additional Tests to Characterize PET Scanners with a Long Axial Field of View

Benjamin A. Spencer, Eric Berg, Jeffrey P. Schmall, Negar Omidvari, Edwin K. Leung, Yasser G. Abdelhafez

The authors evaluated the 194 cm uEXPLORER using standard NEMA tests and extended phantoms for sensitivity and count-rate measurements. They also assessed image quality at several axial positions. Centered-source sensitivity was 174 thousand counts per second per megabecquerel with the standard line source and 147 thousand with a 170 cm line source.

SignificanceThe tests supplied reproducible performance benchmarks for the long-axial-field scanner behind the initial human images. They also documented how standard and human-length phantoms differed in key measurements. Subsequent Monte Carlo work used these data to validate simulated scanner sensitivity and count-rate performance.