diagnostic reference levelDRL
诊断参考水平
A diagnostic reference level is a benchmark for a measurable dose indicator in a defined procedure and patient group. It helps identify protocols whose typical values warrant review.
A diagnostic reference level specifies the procedure, the group of patients, and the quantity being compared. For CT, that quantity can be the volume CT dose index or the dose-length product. A common way to establish a regional benchmark is to take the 75th percentile of the median values reported by participating facilities.
If a facility's typical value consistently exceeds the reference for comparable examinations, the finding prompts a review of scan length, equipment settings, and the image quality needed for diagnosis. Unusually low typical values can also warrant an image quality review. Individual exposures can be adjusted for the needs of the examination. The benchmark supports radiation protection optimization across comparable cases.
- Vañó E, Miller DL, Martin CJ, et al. Diagnostic Reference Levels in Medical Imaging. ICRP Publication 135, 2017. www.icrp.org/publication.asp?id=icrp+publication+135
Key works · 2
Key2017Annals of the ICRP1,338 citations
ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging
The Commission clarified which quantities to use for diagnostic reference levels, how to survey practices, and when to update benchmark values. It extended practical guidance to interventional procedures, pediatric imaging, and newer technologies and discussed how automated dose reporting could support periodic comparisons.
SignificanceThe report turns optimization into a process that can be audited across facilities using comparable examinations. The IAEA uses the diagnostic reference level approach in its implementation guidance to identify protocols whose higher typical doses warrant investigation.
DOI Eliseo VañóA. Rogers radiation doseALARAdiagnostic reference levelCT dose index
Key2023Annals of the ICRP59 citations
Optimisation of Radiological Protection in Digital Radiology Techniques for Medical Imaging
The Commission describes how to optimize protection in digital radiography, fluoroscopy, and CT while preserving image quality adequate for the clinical task. It proposes four levels for facilities to assess their practices, covering equipment selection and monitoring, protocol review, staff training, and collaboration across professions.
SignificancePublication 154 gives digital imaging departments a way to assess their implementation of the Commission's optimization principle in stages. The task group's companion strategy describes how departments can use professional roles, technical capability, and management processes to identify their next steps.
DOI Full text Colin J. MartinJenia Vassileva radiation doseALARAdigital radiographyfluoroscopycomputed tomographydiagnostic reference level