maximum intensity projectionMIP
最大密度投影
Keeping only the brightest voxel along each line of sight, which collapses a 3D volume into one 2D image. Contrast-filled vessels or high-uptake lesions stand out from the background, at the cost of all depth information.
The method is simple. Choose a viewing direction, follow each parallel ray, and display the largest voxel value it meets. Repeating this for a series of angles produces a rotating animation. The only difference from an ordinary projection is that the sum is replaced by the maximum.
MIP began in nuclear medicine: in 1989 Jerold Wallis and colleagues at Washington University in St Louis published "maximum activity projection" for 3D display. It is now the standard view in CT and MR angiography and whole-body PET, and a thin-slab MIP a few millimeters thick helps tell small lung nodules from vessels on chest CT.
The drawbacks are just as plain. Front and back are flattened together; dense bone hides adjacent vessels; and since the maximum of noise is biased upward, small low-contrast vessels can drown in the background. The reverse, minimum intensity projection, is used to show the airways.
- Wallis JW, Miller TR, Lerner CA, Kleerup EC. Three-dimensional display in nuclear medicine. IEEE Trans Med Imaging. 1989;8(4):297–303. doi.org/10.1109/42.41482
Key works · 3
Key1989IEEE Transactions on Medical Imaging198 citations
Three-dimensional display in nuclear medicine
The investigators compared several surface and volume display techniques for nuclear medicine data, including maximum-activity projection, which keeps the highest activity along each viewing ray. Scintigraphic examples illustrated how the different projections represented focal uptake and spatial relationships in the volume.
SignificanceMaximum-activity projection made prominent foci in a volume visible in a single projection. The same maximum-value operation became a display option for CT angiography, where it highlights structures with high attenuation, including vessels opacified with contrast material.
DOI Jerold W. WallisE. C. Kleerup maximum intensity projectionvolume renderingsingle-photon emission computed tomography
Key2004Journal of Digital Imaging1,946 citations
OsiriX: An Open-Source Software for Navigating in Multidimensional DICOM Images
The authors developed an open-source desktop application for navigating large DICOM image series, with multiplanar reformatting, volume rendering, and fusion of PET and CT. The system used ITK and VTK libraries for image processing and rendering and demonstrated navigation with multidimensional, multimodality studies.
SignificanceOsiriX combined DICOM communication and interactive volume display in an extensible open-source desktop application. Follow-up reports described its use for interpreting large PET/CT studies and an extension for sending and retrieving DICOM series between computers over a network.
DOI Full text Antoine RossetOsman Ratib DICOMmultiplanar reconstructionmaximum intensity projectionvolume renderingPET/CT
Key2006RadioGraphics396 citations
Volume Rendering versus Maximum Intensity Projection in CT Angiography: What Works Best, When, and Why
The authors compared maximum intensity projection and volume rendering for CT angiography. Clinical images illustrated what each display preserves and how superimposed structures or rendering choices can affect interpretation. They related the strengths and limitations of the displays to specific clinical tasks.
SignificanceThe review connected algorithmic differences to clinical decisions about displaying CT angiograms. It offered a reference for postprocessing multidetector CT volumes, distinguishing tasks that benefit from emphasizing high-attenuation vessels from those that require surrounding anatomy and depth cues.
DOI Elliot K. FishmanPamela T. Johnson maximum intensity projectionvolume renderingangiographymultidetector CT