volume rendering
体绘制
A 3D display that renders a whole volume directly, without extracting surfaces: each voxel gets a color and an opacity, and rays accumulate them on their way through. Bone, vessels and soft tissue can be shown together in their true spatial relation.
The central component is the transfer function, which maps each CT number to a color and an opacity: bone white and opaque, vessels red and translucent, fat invisible. A ray is cast from every screen pixel, sampled along its path and composited front to back, and , until it is nearly opaque.
Two papers in 1988 laid the foundations: "Volume Rendering" by Robert Drebin, Loren Carpenter and Pat Hanrahan of Pixar at SIGGRAPH, and Marc Levoy's "Display of Surfaces from Volume Data".
Compared with surface rendering, volume rendering keeps translucency and gradual transitions, at a far higher computational cost; interactive use came with the spread of the GPU. Transfer functions are subjective, and a small shift can make a vessel look narrowed or vanish altogether, so diagnosis still goes back to the source slices.
- Drebin RA, Carpenter L, Hanrahan P. Volume rendering. Comput Graph (SIGGRAPH '88). 1988;22(4):65–74. doi.org/10.1145/378456.378484
- Levoy M. Display of surfaces from volume data. IEEE Comput Graph Appl. 1988;8(3):29–37. doi.org/10.1109/38.511
Key works · 8
Landmark1988IEEE Computer Graphics and Applications2,732 citations
Display of surfaces from volume data
Levoy computed voxel shading from local gradients and separately assigned opacity according to a surface classification rule. Combining the shaded samples along each viewing ray produced a surface depiction directly from a three-dimensional array, with examples drawn from medical and molecular data.
SignificanceSeparating shading, classification, and ray compositing gave visualization systems a way to adjust the displayed structures while rendering directly from sampled volumes. Later acceleration work retained voxel classification and compositing while reducing the time required to generate each view.
DOI Full text Marc Levoy volume renderingsurface renderingvoxelisosurface
Landmark1988ACM SIGGRAPH Computer Graphics1,806 citations
Volume rendering
The authors assigned different optical and color properties to materials and their boundaries and computed images by simulating absorption along view rays. The procedures addressed aliasing and quantization artifacts, and the paper illustrated the rendering method on several kinds of volumetric data, including medical images.
SignificanceThis approach made it possible to show several structures and their occlusion relationships from one volume, with optical properties controlling which materials were emphasized. Clinical CT angiography later used related volume-rendering methods to depict vessels alongside relevant surrounding anatomy.
DOI Full text Robert A. DrebinPat Hanrahan volume renderingvoxelaliasing
Landmark1996IEEE Visualization 1996218 citations
The design and implementation of an object-oriented toolkit for 3D graphics and visualization
The authors described the freely available C++ Visualization Toolkit, including its data representations, object model, execution synchronization, and bindings for interpreted languages. They demonstrated how common software components could be assembled into workflows for visualizing scalar, vector, and tensor data.
SignificanceVTK made three-dimensional processing and display algorithms reusable across applications. Medical software such as OsiriX used it for rendering, and IEEE VIS recognized the paper's enduring contribution with a Test of Time Award in 2021.
DOI William J. SchroederKenneth M. MartinWilliam E. Lorensen volume renderingsurface renderingmarching cubes
Key1989IEEE Transactions on Medical Imaging198 citations
Three-dimensional display in nuclear medicine
The investigators compared several surface and volume display techniques for nuclear medicine data, including maximum-activity projection, which keeps the highest activity along each viewing ray. Scintigraphic examples illustrated how the different projections represented focal uptake and spatial relationships in the volume.
SignificanceMaximum-activity projection made prominent foci in a volume visible in a single projection. The same maximum-value operation became a display option for CT angiography, where it highlights structures with high attenuation, including vessels opacified with contrast material.
DOI Jerold W. WallisE. C. Kleerup maximum intensity projectionvolume renderingsingle-photon emission computed tomography
Key1994SIGGRAPH 19941,159 citations
Fast volume rendering using a shear-warp factorization of the viewing transformation
The authors factored the viewing transformation into a three-dimensional shear aligned with the data slices and a two-dimensional warp of an intermediate projection. Traversing the volume and intermediate image in synchrony, with run-length encoding to skip regions, accelerated rendering on contemporary workstations.
SignificanceAligning voxel rows with intermediate image rows reduced the work needed to generate a new view. A subsequent parallel implementation retained the factorization and increased the rate at which medical volumes could be rendered for interactive inspection.
DOI Full text Philippe LacrouteMarc Levoy volume renderingvoxelinterpolation
Key2004Journal of Digital Imaging1,946 citations
OsiriX: An Open-Source Software for Navigating in Multidimensional DICOM Images
The authors developed an open-source desktop application for navigating large DICOM image series, with multiplanar reformatting, volume rendering, and fusion of PET and CT. The system used ITK and VTK libraries for image processing and rendering and demonstrated navigation with multidimensional, multimodality studies.
SignificanceOsiriX combined DICOM communication and interactive volume display in an extensible open-source desktop application. Follow-up reports described its use for interpreting large PET/CT studies and an extension for sending and retrieving DICOM series between computers over a network.
DOI Full text Antoine RossetOsman Ratib DICOMmultiplanar reconstructionmaximum intensity projectionvolume renderingPET/CT
Key2006RadioGraphics396 citations
Volume Rendering versus Maximum Intensity Projection in CT Angiography: What Works Best, When, and Why
The authors compared maximum intensity projection and volume rendering for CT angiography. Clinical images illustrated what each display preserves and how superimposed structures or rendering choices can affect interpretation. They related the strengths and limitations of the displays to specific clinical tasks.
SignificanceThe review connected algorithmic differences to clinical decisions about displaying CT angiograms. It offered a reference for postprocessing multidetector CT volumes, distinguishing tasks that benefit from emphasizing high-attenuation vessels from those that require surrounding anatomy and depth cues.
DOI Elliot K. FishmanPamela T. Johnson maximum intensity projectionvolume renderingangiographymultidetector CT
Key2017American Journal of Roentgenology243 citations
Cinematic Rendering in CT: A Novel, Lifelike 3D Visualization Technique
The article explained how cinematic rendering applies global illumination to CT volumes by modeling light propagation, absorption, and scattering. Side-by-side images of an intracranial aneurysm and an aortic stent illustrated how shading changes the cues to the depth and shape of anatomical structures.
SignificanceThe pictorial review provided an early reference for applying global illumination to clinical CT display. Brookmeyer and colleagues cited the article in their 2024 review of implementation, which described how cinematic rendering fits into postprocessing and preprocedural planning.
DOI Marwen H. EidU. Joseph Schoepf computed tomographyvolume rendering