interpolation
插值
Estimating values between known samples. Resizing, rotating, reformatting (multiplanar reconstruction) and registering images all depend on it. Interpolation makes images smoother but never adds information that was not sampled.
Nearest-neighbor interpolation copies the closest pixel: fast, but edges turn jagged. Linear interpolation (bilinear in 2D, trilinear in 3D) weights neighbors by distance. Cubic interpolation fits a smooth curve through more neighbors; the cubic convolution scheme Robert Keys published in 1981 remains a default in much software. In theory, a signal that obeys the sampling theorem can be rebuilt perfectly with the sinc function, but its reach is infinite, so in practice it is truncated.
Interpolation is an old technique, going back to Babylonian and Greek astronomers filling gaps in tables of planetary positions; digital imaging is one of its most recent applications.
Every interpolation acts as a mild low-pass filter, softening edges, and repeated resampling during registration compounds the blur. Enlarging a low-resolution image by interpolation cannot recover detail that was never captured, which is the problem super-resolution methods take on.
- Keys R. Cubic convolution interpolation for digital image processing. IEEE Trans Acoust Speech Signal Process. 1981;29(6):1153–1160. doi.org/10.1109/TASSP.1981.1163711
- Meijering E. A chronology of interpolation: from ancient astronomy to modern signal and image processing. Proc IEEE. 2002;90(3):319–342. doi.org/10.1109/5.993400
Key works · 4
Landmark1987SIGGRAPH 198712,195 citations
Marching cubes: A high resolution 3D surface construction algorithm
The algorithm visits cells of eight neighboring samples, selects a triangle configuration according to the samples' relationship to an isovalue, and interpolates vertex positions along cell edges. The authors used local gradients for shading and demonstrated the resulting surfaces with CT, MRI, and SPECT data.
SignificanceThe case table and interpolation made isosurface extraction a practical cell-by-cell operation that produced triangular meshes from medical volumes. The Visualization Toolkit later made the method available as a reusable component for extracting surfaces from volume data.
DOI Full text William E. LorensenHarvey E. Cline marching cubessurface renderingvoxelinterpolationisosurface
Landmark1990Radiology1,159 citations
Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation
The investigators combined continuous gantry rotation with controlled continuous table motion, producing a helical acquisition. They interpolated the measurements to reconstruct sections at positions chosen after scanning. Clinical examples included lung nodules and contrast-enhanced studies acquired with single-breath-hold volume coverage.
SignificanceHelical acquisition made it possible to cover an organ continuously in one breath hold and choose reconstruction levels afterward. Subsequent multidetector systems retained helical sampling while increasing the volume covered per gantry rotation and the speed of each examination.
DOI Willi A. KalenderPeter Vock helical CTinterpolationmultiplanar reconstruction
Key1994SIGGRAPH 19941,159 citations
Fast volume rendering using a shear-warp factorization of the viewing transformation
The authors factored the viewing transformation into a three-dimensional shear aligned with the data slices and a two-dimensional warp of an intermediate projection. Traversing the volume and intermediate image in synchrony, with run-length encoding to skip regions, accelerated rendering on contemporary workstations.
SignificanceAligning voxel rows with intermediate image rows reduced the work needed to generate a new view. A subsequent parallel implementation retained the factorization and increased the rate at which medical volumes could be rendered for interactive inspection.
DOI Full text Philippe LacrouteMarc Levoy volume renderingvoxelinterpolation
Key2002IEEE Visualization 2002214 citations
CPR - Curved Planar Reformation
The authors resampled CT volumes along a vessel centerline to display the lumen, wall, and surrounding tissue of a curved vessel in one image. They compared three reformations using a scanned tube phantom and presented thick, rotating, and multipath variants.
SignificanceThe study made explicit how curved reformations display long vessel segments within a single view and how the chosen method changes the representation of length, orientation, and branches. A subsequent paper extended multipath reformation to display an entire vascular tree.
DOI Full text Armin KanitsarMeister Eduard Gröller multiplanar reconstructionangiographycomputed tomographyinterpolation