Image analysis

edge detection

边缘检测

Locating where intensity changes abruptly, which is usually where an organ or lesion ends. Classic detectors compute gradients with small kernels; Canny's 1986 detector remains the standard reference.

An edge is where the gradient is large. Convolving the image with 3×3 Sobel kernels (convolution) gives the horizontal and vertical derivatives and ; the larger the magnitude , the more likely an edge. In 1980 David Marr and Ellen Hildreth instead smoothed with a Gaussian, took the Laplacian, and looked for zero crossings.

In 1986 John Canny posed edge detection as an optimization with three goals: find every real edge, place it accurately, and respond to each edge only once. His detector runs in four steps: Gaussian smoothing, gradient computation, non-maximum suppression to thin edges to one pixel, and hysteresis with two thresholds to join broken fragments.

Medical images pose particular difficulties for edge detectors. noise creates false edges, ultrasound speckle most of all, and low contrast between neighboring soft tissues leaves outlines in pieces. Edge maps are therefore rarely used as segmentations in their own right; more often they supply the pull that guides an active contour (snake).

Sources
  1. Canny J. A computational approach to edge detection. IEEE Trans Pattern Anal Mach Intell. 1986;8(6):679–698. doi.org/10.1109/TPAMI.1986.4767851
  2. Marr D, Hildreth E. Theory of edge detection. Proc R Soc Lond B. 1980;207(1167):187–217. doi.org/10.1098/rspb.1980.0020

Key works · 3

Landmark1986IEEE Transactions on Pattern Analysis and Machine Intelligence35,054 citations

A Computational Approach to Edge Detection

John Canny

Canny expressed reliable detection, accurate localization, and a single response per edge as operator design criteria. For step edges the analysis exposed a trade-off between detection and localization. The approximate implementation finds gradient-magnitude maxima after Gaussian smoothing and links edge points using hysteresis thresholds.

SignificanceThe paper established an edge-detection pipeline derived from explicit performance criteria. The implementation in scikit-image follows the paper's combination of smoothing, nonmaximum suppression, and hysteresis, making those choices available as a reference in subsequent image-processing workflows.

Landmark1988International Journal of Computer Vision18,979 citations

Snakes: Active contour models

Michael Kass, Andrew Witkin, Demetri Terzopoulos

The paper represented a boundary by a spline whose energy combines internal regularity with image forces and external constraints. The spline can settle along a nearby edge or line. The authors demonstrated interactive use, with user-applied forces guiding the contour toward the feature of interest.

SignificanceThe energy formulation gave later work a starting point for imposing curve regularity and incorporating image evidence in one optimization. Balloon contours altered its external forces, and the 1996 medical image analysis survey documented applications of deformable contours to anatomy.

Key1998IEEE Transactions on Image Processing4,401 citations

Snakes, shapes, and gradient vector flow

Chenyang Xu, Jerry L. Prince

The authors built an external force for snakes by diffusing gradient vectors from an edge map. They evolved the snake using force balance. Two- and three-dimensional examples showed both a larger capture range and improved ability to move into concave parts of a boundary.

SignificanceGradient vector flow treated capture range and boundary concavities as properties of the external force. Generalized gradient vector flow subsequently changed the spatial weighting of diffusion while retaining this force construction, directly extending the original method.