Magnetic resonance imaging

In the exhibits3.1 Nuclear spin and Larmor precession3.2 RF excitation and T1/T2 relaxation3.3 1971–1980: the development of MR imaging3.4 Gradients and k-space3.5 TR, TE and image contrast3.6 Safety of MRI7.3 Functional MRI and diffusion imaging9.3 Compressed-sensing MRI8.5 Scanner advances: multidetector CT, PET/CT and 3 T MRI

Landmark1946Physical Review1,657 citations

Nuclear Induction

F. Bloch, W. W. Hansen, Martin Packard

The team applied a radio-frequency field to water in a static magnetic field and measured the induced voltage with a pickup coil oriented perpendicular to the excitation coil. At resonance, the nuclear magnetization of the water produced a detectable signal, demonstrating inductive reception in a liquid sample.

SignificanceInductive pickup became a basic means of receiving nuclear magnetic resonance signals in spectroscopy and imaging. This liquid experiment and the independent solid-state work at Harvard established complementary measurement methods for which Bloch and Purcell shared the 1952 Nobel Prize in Physics.

Landmark1946Physical Review7,634 citations

Resonance Absorption by Nuclear Magnetic Moments in a Solid

E. M. Purcell, H. C. Torrey, R. V. Pound

The authors placed paraffin in a radio-frequency resonant cavity within a static magnetic field and monitored absorption as they varied the field. They detected an absorption signal when the proton precession frequency matched the applied frequency, demonstrating nuclear magnetic resonance in a solid sample.

SignificanceTogether with the independent liquid experiment by Bloch's group, the work established methods for measuring nuclear magnetic resonance in condensed matter. Purcell and Bloch shared the 1952 Nobel Prize in Physics for nuclear magnetic precision measurement methods and associated discoveries.

Landmark1950Physical Review7,007 citations

Spin Echoes

E. L. Hahn

Hahn triggered nuclear magnetic resonance in liquids with sequences of radio-frequency pulses. Magnetization that had dephased produced observable echoes at times set by the pulse intervals. Hahn explained this refocusing, measured relaxation from echo amplitudes, and examined how molecular self-diffusion affected those measurements.

SignificanceSpin echoes supplied a way to refocus dephasing caused by static field inhomogeneity and made tissue-dependent transverse relaxation useful for image contrast. Fast spin-echo imaging subsequently used trains of refocused echoes to collect more image data per excitation.

Followed byStejskal 1965

Landmark1965Mathematics of Computation16,828 citations

An Algorithm for the Machine Calculation of Complex Fourier Series

James W. Cooley, John W. Tukey

Cooley and Tukey factored the calculation of a complex discrete Fourier transform into smaller transforms and reused intermediate results. For sample counts with suitable factors, the work grows approximately as the sample count times its logarithm, compared with quadratic work for direct summation.

SignificanceThis formulation helped popularize the fast Fourier transform, making repeated frequency-domain operations practical for large discrete arrays. Image filtering and MRI reconstruction from measured Fourier data are two applications in which the computational saving matters.

Landmark1965The Journal of Chemical Physics9,555 citations

Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient

E. O. Stejskal, J. E. Tanner

The authors derived how molecular diffusion attenuates spin echoes in a time-dependent field gradient and verified the expression with several gradient waveforms. With pulsed gradients they could define the interval over which diffusion was probed, and they measured the self-diffusion coefficient of dry glycerol.

SignificanceThe work linked a controlled gradient waveform to measurable attenuation caused by random molecular motion. Diffusion MRI later applied this measurement voxel by voxel, and diffusion tensor imaging extended the model to measurements across gradient directions to estimate anisotropic diffusion.

Builds onHahn 1950 Followed byBasser 1994

Key1971Science1,911 citations

Tumor Detection by Nuclear Magnetic Resonance

Raymond Damadian

Damadian used spin-echo measurements to compare longitudinal and transverse relaxation in excised samples of six normal rat tissues and two malignant tumors. The two tumor types had relaxation values outside the range of the normal tissues tested, suggesting that the measurements might help distinguish tissue specimens.

SignificanceDifferences among the excised rat tissues gave an early reason to investigate relaxation as a source of contrast. In his Nobel lecture, Lauterbur recounted how Damadian’s result prompted follow-up experiments and how learning about that research preceded his idea of locating signals with a magnetic field gradient.

Landmark1973Nature5,033 citations

Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance

P. C. Lauterbur

Lauterbur applied a linear magnetic field gradient so that proton resonance frequency depended on position. He recorded projections with the gradient oriented in different directions and combined them to reconstruct a two-dimensional image that resolved two water-filled tubes immersed in heavy water.

SignificanceThe work showed how to recover a two-dimensional image from nuclear magnetic resonance signals by deliberately encoding position. Gradient-based spatial encoding became a fundamental principle of MRI and was recognized in the scientific background for the 2003 Nobel Prize in Physiology or Medicine.

Followed byKumar 1975

Key1974Journal of Physics C: Solid State Physics370 citations

Image formation in NMR by a selective irradiative process

A N Garroway, P K Grannell, P Mansfield

The authors combined switched magnetic field gradients with frequency-selective radio-frequency irradiation to excite or saturate spins in chosen parts of a sample. They reported preliminary experiments illustrating the components of the method and produced a two-dimensional image of a simple object.

SignificanceApplying a selective pulse in a gradient made it possible to prescribe the slice to be imaged. Spin-warp imaging combined this form of slice selection with frequency and phase encoding, a combination that became standard in clinical two-dimensional MRI.

Landmark1975Journal of Magnetic Resonance881 citations

NMR Fourier zeugmatography

Anil Kumar, Dieter Welti, Richard R. Ernst

The authors applied sequences of pulsed magnetic field gradients during a series of free induction decays to encode the spatial frequency components of spin density. A multidimensional Fourier transform reconstructed the image. The paper set out how the gradient pulses and measurement timing determined which components were acquired.

SignificanceDirect Fourier sampling offered a framework for combining frequency encoding with repeated phase encoding. The subsequent spin-warp method adapted Fourier encoding for routine image acquisition, establishing an approach that remains central to conventional clinical magnetic resonance imaging.

Builds onLauterbur 1973

Landmark1977Journal of Physics C: Solid State Physics2,341 citations

Multi-planar image formation using NMR spin echoes

P Mansfield

Mansfield proposed a method for rapidly acquiring two- or three-dimensional spin-density data using nuclear magnetic resonance echoes in time-dependent field gradients. The analysis showed how signals arising from spins across a plane or a set of planes could be distinguished within the readout.

SignificanceThis paper set out the acquisition principle of echo-planar imaging. Once gradient and readout hardware could implement the approach, a single excitation could supply the data for an image, providing the temporal resolution needed to follow functional brain signals on the scale of seconds.

Followed byStehling 1991

Landmark1980Physics in Medicine and Biology952 citations

Spin warp NMR imaging and applications to human whole-body imaging

W A Edelstein, J M S Hutchison, G Johnson, T Redpath

The Aberdeen group described spin-warp imaging, in which a gradient encodes phase with a different amplitude on successive excitations and a readout gradient encodes frequency. They presented examples of human imaging with the sequence using a 0.04 tesla magnet large enough to accommodate the body.

SignificanceSpin-warp imaging made slice selection and Fourier encoding practical in a sequence for human scanning. Aberdeen subsequently used its system to scan a patient, and the method's line-by-line acquisition of spatial frequency data became a standard approach in clinical MRI.

Key1983Medical Physics497 citations

The k-trajectory formulation of the NMR imaging process with applications in analysis and synthesis of imaging methods

Donald B. Twieg

Twieg formulated several nuclear magnetic resonance imaging methods as sampling in the spatial-frequency domain, with the gradient history determining the trajectory of sampled points. He used this common description to compare how projection, spin-warp, Fourier, and echo-planar methods measure different spatial frequencies.

SignificanceA common spatial-frequency description made it possible to compare how apparently different sequences cover the data needed for an image and to design new acquisitions. Gradient-defined trajectories in k-space remain standard in describing MRI acquisition and reconstruction.

Key1984The Lancet259 citations

Intravenous chelated gadolinium as a contrast agent in NMR imaging of cerebral tumours

D. H. Carr, J. Brown, G. M. Bydder, H. J. Weinmann, U. Speck … I. R. Young

The authors imaged 12 patients with brain tumors before and after intravenous administration of the gadolinium chelate Gd-DTPA. All tumors enhanced after injection. Ring enhancement was the most frequent pattern, and enhancement was visible with both inversion-recovery and spin-echo sequences.

SignificanceThis patient study provided early evidence that a gadolinium chelate could improve visualization of brain tumors. Contrast based on relaxation changes after administration of paramagnetic agents subsequently became an established option for delineating lesions of the central nervous system.

Landmark1986Journal of Magnetic Resonance1,492 citations

FLASH imaging. Rapid NMR imaging using low flip-angle pulses

A. Haase, J. Frahm, D. Matthaei, W. Hänicke, K.-D. Merboldt

FLASH used small flip-angle radio-frequency pulses to retain longitudinal magnetization for the next excitation, allowing successive measurements at short intervals. The sequence reversed the readout gradient to generate an echo. Demonstrated acquisition times were about one second for 64 by 128 pixels and six seconds for 256 by 256.

SignificanceCombining small excitations with gradient echoes established a way to speed MRI by shortening the repetition interval. Kose’s technical history traces the development of fast T1-weighted imaging from FLASH to later sequences that used radio-frequency spoiling to control residual transverse magnetization.

Landmark1986Radiology4,375 citations

MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders

D. Le Bihan, E. Breton, D. Lallemand, P. Grenier, E. Cabanis, M. Laval-Jeantet

The authors used gradient pulses to measure spin-echo attenuation associated with diffusion and microcirculation within individual voxels. Measurements in water and acetone phantoms reproduced known diffusion values, and estimates of apparent diffusion in neurologic images differed between several normal and pathologic tissues.

SignificanceThe work established a way to map apparent diffusion in human tissue and introduced intravoxel incoherent motion as an imaging measurement. Subsequent tensor imaging used diffusion encoding in multiple directions to characterize anisotropy as well as overall diffusion magnitude.

Landmark1986Magnetic Resonance in Medicine2,345 citations

RARE imaging: A fast imaging method for clinical MR

Jürgen Hennig, Arno Nauerth, Hartmut Friedburg

The team assigned a different phase-encoding step to each of several spin echoes following excitation, collecting enough data for a 256 by 256 image in 2 to 40 seconds. They examined artifacts caused by changing T2 weighting across the echo train and how phase-encoding order could reduce them.

SignificanceAcquiring multiple k-space lines from a train of refocused echoes became the basis of clinical fast or turbo spin-echo imaging. Later implementations retained this approach to accelerating T2-weighted acquisitions while addressing the blurring and radio-frequency demands of long echo trains.

Landmark1990Proceedings of the National Academy of Sciences8,190 citations

Brain magnetic resonance imaging with contrast dependent on blood oxygenation

S. Ogawa, T. M. Lee, A. R. Kay, D. W. Tank

The authors used high-field gradient echoes to observe brain microvasculature in live animals, exploiting the paramagnetism of deoxygenated hemoglobin. Image contrast changed when anesthesia, hypoglycemia, or inhaled gases altered physiology. The team named the effect blood oxygenation level-dependent, or BOLD, contrast.

SignificanceBOLD supplied an endogenous source of magnetic susceptibility contrast linked to blood oxygenation. Subsequent human visual stimulation experiments used that mechanism to localize task-related responses, establishing the signal used in a large share of functional MRI studies.

Followed byOgawa 1992

Key1990Magnetic Resonance in Medicine1,808 citations

Early detection of regional cerebral ischemia in cats: Comparison of diffusion- and T2-weighted MRI and spectroscopy

M. E. Moseley, Y. Cohen, J. Mintorovitch, L. Chileuitt, H. Shimizu … P. R. Weinstein

The authors compared diffusion-weighted imaging, T2-weighted imaging, and magnetic resonance spectroscopy after arterial occlusion in eight cats. Diffusion-weighted images showed increased signal in the ischemic region as early as 45 minutes. T2-weighted spin-echo images did not clearly show injury for two to three hours.

SignificanceThe animal experiment established that diffusion weighting could show changes in acute ischemia earlier than conventional T2 weighting. Subsequent human work tested this early diffusion signal in acute cerebral infarction and helped establish diffusion imaging in stroke assessment.

Landmark1990Magnetic Resonance in Medicine2,653 citations

The NMR phased array

P. B. Roemer, W. A. Edelstein, C. E. Hayes, S. P. Souza, O. M. Mueller

The authors reduced coupling among receiving coils by overlapping neighboring coils and using low-input-impedance preamplifiers. They derived a rule for combining coil data to maximize signal-to-noise ratio. Two four-element arrays yielded twofold and threefold gains at the depth of the spine compared with one large coil under matched imaging conditions.

SignificanceThe receive array provided broad coverage while preserving separate measurements from local coils. Both SMASH and SENSE cited the array work and used differences among coil sensitivities as spatial encoding, turning those separate measurements into a means of accelerating acquisition.

Followed bySodickson 1997

Notable1991Science746 citations

Echo-Planar Imaging: Magnetic Resonance Imaging in a Fraction of a Second

Michael K. Stehling, Robert Turner, Peter Mansfield

This review described the implementation of echo-planar imaging, which uses rapid gradient changes to acquire an image after a single spin excitation, in a fraction of a second. It discussed applications of that speed to diffusion, perfusion, and dynamic studies of the heart and other organs.

SignificanceThe review documents the transition from the echo-planar imaging proposal to an acquisition that could be implemented on imaging hardware. Subsequent human functional experiments used related rapid readouts to follow task-evoked signals, demonstrating an application discussed in the review.

Builds onMansfield 1977

Landmark1991Science2,131 citations

Functional Mapping of the Human Visual Cortex by Magnetic Resonance Imaging

John W. Belliveau, David N. Kennedy Jr., Robert C. McKinstry, Bradley R. Buchbinder, Robert M. Weisskoff, Mark S. Cohen

The team used magnetic resonance imaging with an injected contrast agent to compare regional cerebral blood volume at rest and during flashing visual stimulation. They measured a local blood volume increase in the primary visual cortex of seven participants and mapped the response.

SignificanceThese were the first published MR maps of task-evoked brain activity in humans, showing that a hemodynamic response could be localized to a specific cortical region. The same research center subsequently demonstrated functional mapping using endogenous contrast.

Followed byKwong 1992

Landmark1992Proceedings of the National Academy of Sciences4,763 citations

Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation

K. K. Kwong, J. W. Belliveau, D. A. Chesler, I. E. Goldberg, R. M. Weisskoff, B. P. Poncelet

The authors acquired fast echo-planar images through visual and motor tasks, using a gradient-echo sequence sensitive to oxygenation and an inversion-recovery sequence sensitive to flow. During 8 Hz visual stimulation in seven volunteers, both sequences showed a mean signal increase of about 1.8% in primary visual cortex.

SignificanceThis study demonstrated that endogenous hemodynamic contrast could identify task responses in human cortex on the scale of seconds. Together with independent reports in the same year, it established a way to map human task responses with MRI without injecting a contrast agent.

Builds onBelliveau 1991

Key1992Neurology962 citations

Fast magnetic resonance diffusion-weighted imaging of acute human stroke

S. Warach, D. Chien, W. Li, M. Ronthal, R. R. Edelman

The authors used rapid diffusion-weighted MRI in patients with cerebral infarction and compared the findings with conventional T2-weighted spin-echo images. Diffusion weighting revealed some infarcts earlier than the conventional sequence, and acute lesions showed lower apparent diffusion coefficients than unaffected regions.

SignificanceThe patient study connected early changes in water diffusion during cerebral ischemia with lesion detection in human stroke. In 1995, the group extended the clinical work to whole-brain echo-planar imaging in 40 patients and confirmed that early diffusion abnormalities could precede changes visible on conventional MRI.

Landmark1992Proceedings of the National Academy of Sciences4,224 citations

Intrinsic signal changes accompanying sensory stimulation: functional brain mapping with magnetic resonance imaging

S. Ogawa, D. W. Tank, R. Menon, J. M. Ellermann, S.-G. Kim … K. Ugurbil

At 4 tesla the authors used gradient-echo imaging to detect transient signal increases in primary visual cortex during visual stimulation. The fractional response fell when the echo time was shortened, consistent with a change in apparent transverse relaxation associated with blood oxygenation.

SignificanceThe study extended BOLD contrast from animal experiments to human cortical mapping and used echo-time dependence to test the proposed mechanism. It was one of three contemporary demonstrations that helped establish endogenous hemodynamic contrast for task-based functional imaging.

Builds onOgawa 1990

Key1992Magnetic Resonance in Medicine1,842 citations

Perfusion imaging

John A. Detre, John S. Leigh, Donald S. Williams, Alan P. Koretsky

The authors used radio-frequency pulses at 4.7 tesla to saturate water protons in arterial blood flowing toward the rat brain. They compared the resulting images with a distal saturation control to estimate regional cerebral blood flow, and detected changes associated with raised arterial carbon dioxide.

SignificanceThe rat experiment demonstrated quantitative perfusion imaging using arterial water as an endogenous tracer. This measurement principle is central to arterial spin labeling. A 2015 consensus from the ISMRM perfusion group and the European consortium for ASL in dementia gave implementation guidance for clinical MRI.

Landmark1992Magnetic Resonance in Medicine2,200 citations

Time course EPI of human brain function during task activation

Peter A. Bandettini, Eric C. Wong, R. Scott Hinks, Ronald S. Tikofsky, James S. Hyde

Using gradient-echo echo-planar imaging, the authors repeatedly scanned the human brain during a finger movement task. They observed a local signal increase and compared the time course at each location with the task schedule to map regions where the two were correlated.

SignificanceThree independent groups established human task functional MRI with endogenous contrast in the same period. This study showed how a rapid image series and the temporal correspondence between signal and task could be used to localize motor responses.

Landmark1994Biophysical Journal6,758 citations

MR diffusion tensor spectroscopy and imaging

P. J. Basser, J. Mattiello, D. LeBihan

The authors estimated a diffusion tensor from magnetic resonance signals acquired along multiple gradient directions and represented the resulting directional diffusivities as an ellipsoid. They demonstrated the method in muscle samples and ex vivo cat brain and described orientation-independent quantities derived from the tensor.

SignificanceDiffusion tensor imaging made anisotropy measurable voxel by voxel and yielded a principal diffusion direction that could estimate local tissue orientation. Early tractography studies subsequently used such directions to reconstruct three-dimensional paths through white matter in living subjects.

Builds onStejskal 1965

Landmark1995Magnetic Resonance in Medicine10,980 citations

Functional connectivity in the motor cortex of resting human brain using echo-planar MRI

Bharat Biswal, F. Zerrin Yetkin, Victor M. Haughton, James S. Hyde

The investigators first localized sensorimotor regions using hand movement and then recorded a resting echo-planar image series. Low-frequency fluctuations in the resting signal showed strong temporal correlations across the localized regions and with other brain areas related to motor function.

SignificanceThe study introduced the use of correlations in spontaneous resting signals to estimate functional relationships between brain regions. Later whole-brain resting-state imaging studies extended this type of measurement to identify groups of regions forming distributed functional networks.

Key1997Magnetic Resonance in Medicine2,458 citations

Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays

Daniel K. Sodickson, Warren J. Manning

SMASH formed spatial harmonics by linearly combining the sensitivities of array elements. This enabled the reconstruction of skipped phase-encoding lines in k-space before Fourier transformation. Using commercial phased arrays on two MRI systems, the authors demonstrated a twofold reduction in acquisition time.

SignificanceSMASH established a way to recover phase encoding in k-space from the spatial responses of a coil array. The later VD-AUTO-SMASH method used extra acquired data to calibrate the synthesis. The GRAPPA paper identifies that self-calibrating variant as one of its direct predecessors.

Builds onRoemer 1990

Landmark1999Magnetic Resonance in Medicine7,212 citations

SENSE: Sensitivity encoding for fast MRI

Klaas P. Pruessmann, Markus Weiger, Markus B. Scheidegger, Peter Boesiger

The authors used spatial differences in receiver coil sensitivity as additional encoding and formulated a reconstruction from reduced Fourier sampling. Two coils halved acquisition time for the demonstrated brain images, and five coils gave double-oblique cardiac images in one-third of the conventional time.

SignificanceSENSE established image-domain parallel imaging by showing how receiver sensitivity maps can separate pixels folded together by undersampling. Its formulation also described noise amplification associated with coil geometry, an important consideration when choosing an acceleration factor for routine clinical imaging.

Key1999Proceedings of the National Academy of Sciences1,948 citations

Tracking neuronal fiber pathways in the living human brain

T. E. Conturo, N. F. Lori, T. S. Cull, E. Akbudak, A. Z. Snyder, J. S. Shimony

The authors estimated the direction of fastest water diffusion in living human brains and followed these directions step by step from seed points. They selected paths connecting defined brain regions and demonstrated trajectories in the corpus callosum, visual projections, and subcortical association pathways.

SignificanceThis was an early demonstration of deriving spatial models of human white matter pathways from local diffusion directions and selecting them using anatomical or functional regions. It made it possible to use in vivo diffusion data to examine candidate connections between specified brain areas.

Key2001Magnetic Resonance in Medicine980 citations

7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images

J. Thomas Vaughan, Michael Garwood, Christopher M. Collins, Wei Liu, Lance DelaBarre, Gregor Adriany

The authors compared human head imaging at 7 and 4 tesla using measurements and electromagnetic modeling. At 7 tesla, average brain signal-to-noise was at least 1.6 times the value at 4 tesla, while the radio-frequency field was less uniform and excitation at the center of the head required more power.

SignificanceThe controlled comparison quantified both the signal gain and the radio-frequency engineering demands of ultrahigh field, providing a reference for subsequent coil and imaging work. The US Food and Drug Administration cleared the first clinical 7 tesla device in 2017.

Landmark2002Magnetic Resonance in Medicine5,951 citations

Generalized autocalibrating partially parallel acquisitions (GRAPPA)

Mark A. Griswold, Peter M. Jakob, Robin M. Heidemann, Mathias Nittka, Vladimir Jellus … Axel Haase

The authors used extra calibration lines to estimate local relationships among the receiver coils in k-space. They used those relationships to recover missing data for each coil before reconstructing and combining coil images. The paper described implementation and signal-to-noise behavior and demonstrated in vivo imaging.

SignificanceGRAPPA incorporated calibration into parallel acquisition and reconstructed missing samples directly in k-space. It became a common clinical parallel imaging method and supplied a reference for later approaches that generalized how relationships among coil measurements could be calibrated and enforced.

Notable2003Investigative Radiology247 citations

Magnetic Resonance Imaging at 3.0 Tesla: Challenges and Advantages in Clinical Neurological Imaging

Richard Frayne, Bradley G. Goodyear, Peter Dickhoff, M. Louis Lauzon, Robert J. Sevick

The Calgary group summarized 40 months of clinical neuroradiology at 3 tesla and presented patient images to illustrate potential benefits relative to 1.5 tesla. They described higher signal-to-noise and changes in contrast alongside practical issues involving radio-frequency power, coil design, and implant compatibility.

SignificanceThis report documented early clinical operation at 3 tesla and made the practical demands of higher-field imaging explicit alongside its benefits. Later guidance from the American College of Radiology continues to address risks by field strength and device conditions.

Landmark2006IEEE Transactions on Information Theory28,483 citations

Compressed sensing

David L. Donoho

Donoho analyzed signals that can be approximated by a small number of coefficients in a known transform. The paper established that nonadaptive linear measurements and convex optimization can recover useful approximations from many fewer measurements than signal dimensions and characterized the achievable accuracy.

SignificanceThe work placed signal compressibility and the choice of measurements within a common recovery framework. The sparse MRI study cited it in adapting this principle to MR images, using sparse transforms and an acquisition designed to collect less data.

Followed byLustig 2007

Landmark2006IEEE Transactions on Information Theory16,969 citations

Robust uncertainty principles: exact signal reconstruction from highly incomplete frequency information

Emmanuel J. Candès, Justin Romberg, Terence Tao

The authors studied recovery of a sparse signal from a randomly selected subset of its Fourier coefficients. They proved that under specified conditions, minimizing an L1 norm recovers the signal exactly with high probability even when the positions and amplitudes of its nonzero entries are unknown.

SignificanceThe Fourier recovery result showed how sparsity and a sampling design can jointly constrain an underdetermined reconstruction. Sparse MRI subsequently adapted this reasoning to incomplete k-space data and extended it to practical acquisitions, sparsifying transforms, and data fidelity constraints.

Followed byLustig 2007

Landmark2007Magnetic Resonance in Medicine7,800 citations

Sparse MRI: The application of compressed sensing for rapid MR imaging

Michael Lustig, David Donoho, John M. Pauly

The authors undersampled phase-encoding lines with a variable-density pseudorandom pattern and reconstructed images by penalizing transform coefficients subject to consistency with the measured data. Examples in multislice fast spin-echo brain images and three-dimensional contrast-enhanced angiography demonstrated how the method could accelerate acquisition.

SignificanceThe paper converted compressed sensing into an acquisition and reconstruction procedure that could be implemented on an MR scanner. Later studies combined sparse recovery and parallel imaging and evaluated the resulting shorter acquisitions in settings such as contrast-enhanced pediatric abdominal MRI.

Builds onCandès 2006, Donoho 2006 Followed byHammernik 2018

Key2011Physics in Medicine & Biology439 citations

Design and performance evaluation of a whole-body Ingenuity TF PET–MRI system

H. Zaidi, N. Ojha, M. Morich, J. Griesmer, Z. Hu, P. Maniawski

This study evaluated a sequential whole-body system combining a time-of-flight PET scanner with 3 T MRI. The PET photomultipliers received magnetic shielding and the electronics were relocated to reduce mutual interference. Measurements characterized PET performance and the use of MR-derived attenuation maps.

SignificanceThe Philips sequential design retained photomultiplier-based PET detectors through shielding and physical separation. In their evaluation of the simultaneous Siemens scanner, Delso and colleagues discussed the Philips design as a contemporaneous clinical alternative. Their standardized phantom measurements characterized the Siemens scanner.

Builds onSurti 2007

Key2011Journal of Nuclear Medicine960 citations

Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR Scanner

Gaspar Delso, Sebastian Fürst, Björn Jakoby, Ralf Ladebeck, Carl Ganter … Sibylle I. Ziegler

Delso and colleagues measured an integrated whole-body PET/MR scanner while each subsystem operated independently and while both acquired data together. PET measurements included resolution, sensitivity, scatter, and count losses. MRI quality-control tests covered geometric accuracy and signal quality. The authors reported no perceptible effect on overall performance from integration under the conditions they tested.

SignificanceThe evaluation documented the first commercial integrated whole-body PET/MR scanner with simultaneous acquisition. Collecting emissions and MR data over the same period made it possible to investigate tracer behavior alongside MR measures of anatomy and function.

Landmark2013NeuroImage6,502 citations

The WU-Minn Human Connectome Project: An overview

David C. Van Essen, Stephen M. Smith, Deanna M. Barch, Timothy E.J. Behrens, Essa Yacoub … for the WU-Minn HCP Consortium

The WU-Minn Human Connectome Project planned multimodal data collection for approximately 1,200 healthy young adults. The overview described structural, functional, and diffusion MRI alongside behavioral measures, set out processing and sharing plans, and presented initial examples of functional connectivity analyses.

SignificanceCommon acquisitions and processing made it possible to study functional and structural connectivity in the same population. Later releases through ConnectomeDB, with associated analysis tools, provided a resource for comparing and repeating network analyses on shared multimodal data.

Landmark2016Nature Neuroscience2,190 citations

Multimodal population brain imaging in the UK Biobank prospective epidemiological study

Karla L Miller, Fidel Alfaro-Almagro, Neal K Bangerter, David L Thomas, Essa Yacoub, Junqian Xu

The paper described the UK Biobank's multimodal brain MRI protocol and the analysis of the first roughly 5,000 imaged participants. It derived structural, functional, and diffusion measures and related selected imaging phenotypes to other participant information as demonstrations of population analysis.

SignificanceStandardized imaging and derived measures made it possible to link brain phenotypes with health, behavioral, and genetic information in a large cohort. UK Biobank provides access through research applications so independent investigations can reuse the same underlying measurements.

Landmark2018Magnetic Resonance in Medicine2,036 citations

Learning a variational network for reconstruction of accelerated MRI data

Kerstin Hammernik, Teresa Klatzer, Erich Kobler, Michael P. Recht, Daniel K. Sodickson … Florian Knoll

The network unrolled gradient updates of a variational model for multicoil MRI, learning its filters, activation functions, and weights for the measured-data terms. It was tested on retrospectively and prospectively undersampled knees. Quantitative comparisons and a reader study supported the results for fourfold regular undersampling.

SignificanceThe variational network made the parallel MRI acquisition model and the learned image prior explicit within a single trainable system. The later end-to-end variational network developed this design further by incorporating coil sensitivity estimation in the same reconstruction model.

Builds onLustig 2007 Followed bySriram 2020

Landmark2019IEEE Transactions on Medical Imaging1,490 citations

MoDL: Model-Based Deep Learning Architecture for Inverse Problems

Hemant K. Aggarwal, Merry P. Mani, Mathews Jacob

MoDL alternated a learned convolutional regularizer with steps that fit the measured data, sharing the convolutional weights across iterations. A conjugate gradient block solved the data consistency subproblem. In undersampled MRI experiments, the solver improved convergence per iteration when available memory restricted the network depth.

SignificanceWeight sharing made it possible to change the number of reconstruction steps while holding the number of learned parameters fixed. The subsequent parallel MRI survey uses MoDL to illustrate the combination of an explicit forward model and a learned regularizer.

Key2020IEEE Signal Processing Magazine514 citations

Deep-Learning Methods for Parallel Magnetic Resonance Imaging Reconstruction: A Survey of the Current Approaches, Trends, and Issues

Florian Knoll, Kerstin Hammernik, Chi Zhang, Steen Moeller, Thomas Pock … Mehmet Akçakaya

The review explains linear and nonlinear parallel MRI reconstruction from image-domain and k-space perspectives. It describes ways to use neural networks as learned image regularizers or as interpolators for missing k-space measurements. It also discusses measurement consistency, public benchmarks, and performance across acquisition conditions.

SignificanceThis widely cited technical reference ties learning methods to the physics of multicoil MRI. It supplies a common vocabulary for comparing image enhancement, direct reconstruction and methods that explicitly enforce data consistency, and documents the early availability of benchmarks for testing those differences.

Key2021JAMA Neurology311 citations

Assessment of Brain Injury Using Portable, Low-Field Magnetic Resonance Imaging at the Bedside of Critically Ill Patients

Kevin N. Sheth, Mercy H. Mazurek, Matthew M. Yuen, Bradley A. Cahn, Jill T. Shah, Adrienne Ward

In this single-center prospective study, the team performed bedside brain MRI for 50 intensive care patients using a portable 0.064 tesla scanner. They obtained several image contrasts, documented abnormalities and the numbers of diagnostic-grade examinations by sequence, and reported no adverse events during deployment or scanning.

SignificanceThe study established feasibility for acquiring brain MRI at the bedside in intensive care. Follow-up work evaluated measurements such as intracranial midline shift, and the American College of Radiology subsequently addressed the use of portable ultralow-field systems in its safety guidance.

Key2025Radiology65 citations

American College of Radiology Manual on MR Safety: 2024 Update and Revisions

Ivan Pedrosa, David A. Altman, Jonathan R. Dillman, Michael N. Hoff, Alexander M. McKinney, Scott B. Reeder

Members of the American College of Radiology committee described the structure and rationale of the 2024 safety manual. They reviewed facility zones, staff roles, patient and equipment screening, and emergency procedures, as well as evidence gaps for remote operation and scanners outside conventional field strengths.

SignificanceThe article documents the technical and clinical reasoning behind the American College of Radiology's consolidated MR safety recommendations. The manual covers institutional controls for risks from static fields, switched gradients, and radio-frequency exposure and addresses portable and ultrahigh-field systems.

Notable2025Medical Image Analysis39 citations

Brain Latent Progression: Individual-based spatiotemporal disease progression on 3D Brain MRIs via latent diffusion

Lemuel Puglisi, Daniel C. Alexander, Alzheimer’s Disease Neuroimaging Initiative, Australian Imaging Biomarkers and Lifestyle flagship study of aging, Daniele Ravì

BrLP combines latent diffusion with estimates of changes in structure volumes to forecast an individual’s future 3D brain MRI from available observations. Its external test used 2,257 T1-weighted scans from 962 NACC participants, comparing generated images with actual follow-up scans.

SignificanceObserved scans provided a reference for image and structure-volume prediction errors. The authors separately estimated uncertainty at the scan and voxel levels, and found that the forecasts tended toward changes typical of healthy aging in this study of aging and Alzheimer’s disease.

Notable2026ECCV 2026 (LNCS 17076)17 citations

CLARITY: Medical World Model for Guiding Treatment Decisions by Simulating Context-Aware Disease Trajectories

Tianxingjian Ding, Yuanhao Zou, Chen Chen, Mubarak Shah, Yu Tian

CLARITY predicts changes in imaging-derived features using elapsed time, clinical information, and treatments, then scores simulated trajectories with a survival model. Retrospective endpoints included survival prediction, agreement of proposed and recorded regimens, and a blinded expert comparison of recommendations for 40 held-out cases.

SignificanceThe work makes treatment an input to imaging state transitions. Regimen matching and expert ratings measure agreement and plausibility, respectively. The effect of an alternative treatment on an individual would require evidence beyond these retrospective comparisons.