MG·LB · Key works

Deep-learning image reconstruction

In the exhibits11.2 Deep-learning image reconstruction9.3 Compressed-sensing MRI

Landmark2006IEEE Transactions on Information Theory28,483 citations

Compressed sensing

David L. Donoho

Donoho analyzed signals that can be approximated by a small number of coefficients in a known transform. The paper established that nonadaptive linear measurements and convex optimization can recover useful approximations from many fewer measurements than signal dimensions and characterized the achievable accuracy.

SignificanceThe work placed signal compressibility and the choice of measurements within a common recovery framework. The sparse MRI study cited it in adapting this principle to MR images, using sparse transforms and an acquisition designed to collect less data.

Followed byLustig 2007

Landmark2006IEEE Transactions on Information Theory16,969 citations

Robust uncertainty principles: exact signal reconstruction from highly incomplete frequency information

Emmanuel J. Candès, Justin Romberg, Terence Tao

The authors studied recovery of a sparse signal from a randomly selected subset of its Fourier coefficients. They proved that under specified conditions, minimizing an L1 norm recovers the signal exactly with high probability even when the positions and amplitudes of its nonzero entries are unknown.

SignificanceThe Fourier recovery result showed how sparsity and a sampling design can jointly constrain an underdetermined reconstruction. Sparse MRI subsequently adapted this reasoning to incomplete k-space data and extended it to practical acquisitions, sparsifying transforms, and data fidelity constraints.

Followed byLustig 2007

Landmark2007Magnetic Resonance in Medicine7,800 citations

Sparse MRI: The application of compressed sensing for rapid MR imaging

Michael Lustig, David Donoho, John M. Pauly

The authors undersampled phase-encoding lines with a variable-density pseudorandom pattern and reconstructed images by penalizing transform coefficients subject to consistency with the measured data. Examples in multislice fast spin-echo brain images and three-dimensional contrast-enhanced angiography demonstrated how the method could accelerate acquisition.

SignificanceThe paper converted compressed sensing into an acquisition and reconstruction procedure that could be implemented on an MR scanner. Later studies combined sparse recovery and parallel imaging and evaluated the resulting shorter acquisitions in settings such as contrast-enhanced pediatric abdominal MRI.

Builds onCandès 2006, Donoho 2006 Followed byHammernik 2018

Key2008Physics in Medicine & Biology2,229 citations

Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization

Emil Y. Sidky, Xiaochuan Pan

The algorithm minimized image total variation while enforcing nonnegativity and requiring the calculated projections to agree with the data within a tolerance. It combined adaptive steepest descent with projection onto convex sets and was tested on simulated cone-beam data from disk and jaw phantoms.

SignificanceThe paper became a widely cited baseline for sparse-view CT, separating the allowed projection error from the total variation penalty. The same group subsequently extended the framework to measured low-intensity X-ray projections and tested it under reduced-exposure conditions.

Key2017Medical Physics924 citations

A deep convolutional neural network using directional wavelets for low‐dose X‐ray CT reconstruction

Eunhee Kang, Junhong Min, Jong Chul Ye

The researchers applied a residual convolutional network to directional wavelet coefficients of reconstructed low-dose CT. The transform exposed oriented noise patterns and dependencies across bands. The method placed second in the 2016 Low Dose CT Grand Challenge, whose evaluation included readers marking liver metastases.

SignificanceThe challenge gave this early denoising method a common test set and a reader-based endpoint. The approach also established a practical example of performing learned denoising in a transform basis, a distinction retained in later reviews of low-dose CT methods.

Landmark2017IEEE Transactions on Image Processing2,968 citations

Deep Convolutional Neural Network for Inverse Problems in Imaging

Kyong Hwan Jin, Michael T. McCann, Emmanuel Froustey, Michael Unser

FBPConvNet first applied filtered back-projection to sparse-view CT data, then used a multiresolution residual convolutional network to remove artifacts in the initial image. The authors tested synthetic phantoms and real experimental sinograms. On their more realistic phantoms, it outperformed a total-variation reconstruction baseline.

SignificanceThe paper provided a prominent baseline for combining a conventional inverse with learned artifact correction. The Learned Primal-Dual study later used learned post-processing of filtered back-projection as a comparator for a network that instead placed the measurement operator inside the reconstruction.

Key2017IEEE Transactions on Medical Imaging1,150 citations

Generative Adversarial Networks for Noise Reduction in Low-Dose CT

Jelmer M. Wolterink, Tim Leiner, Max A. Viergever, Ivana Išgum

The authors trained a denoiser using cardiac CT images acquired at 20% of the routine dose. Voxel loss alone yielded the highest peak signal-to-noise ratio, while adversarial training better reproduced routine-dose image statistics. Denoising improved low-density calcium measurements in phantoms and enabled calcium scoring on noisy patient scans.

SignificanceThe experiment distinguished agreement with reference pixels, similarity of noise appearance, and usability for calcium scoring on the same set of scans. Reviews of low-dose CT restoration include it among the early uses of adversarial objectives in image-domain denoising.

Key2017Medical Physics425 citations

Low-dose CT for the detection and classification of metastatic liver lesions: Results of the 2016 Low Dose CT Grand Challenge

Cynthia H. McCollough, Adam C. Bartley, Rickey E. Carter, Baiyu Chen, Tammy A. Drees, Phillip Edwards

The Low Dose CT Grand Challenge supplied common contrast-enhanced CT cases to groups testing image-space denoising or iterative reconstruction. Participants reconstructed twenty quarter-dose test examinations. Eleven blinded readers marked liver metastases, with substantial differences in reader scores across the submitted reconstruction and denoising methods.

SignificanceThe competition tied reconstruction evaluation to the clinical task of detecting liver metastases. The Cancer Imaging Archive's larger collection includes 13 of the challenge test cases. A separate release provides all 30 training and test cases in the same standardized projection format for further comparisons.

Landmark2017IEEE Transactions on Medical Imaging2,163 citations

Low-Dose CT With a Residual Encoder-Decoder Convolutional Neural Network

Hu Chen, Yi Zhang, Mannudeep K. Kalra, Feng Lin, Yang Chen … Ge Wang

RED-CNN trained a residual convolutional encoder-decoder on image patches to denoise reconstructed low-dose CT. Its shortcuts linked encoder and decoder layers. Tests using simulated and clinical images compared noise suppression, preservation of anatomical structure, and lesion visibility with those of other image-domain methods.

SignificanceRED-CNN became a reference for denoising low-dose CT images after reconstruction, which makes the method testable without access to vendor-specific projections. Zeng and colleagues used it to study how differences in dose, reconstruction kernel, and slice thickness between training and testing affect denoising.

Landmark2018IEEE Transactions on Medical Imaging1,499 citations

A Deep Cascade of Convolutional Neural Networks for Dynamic MR Image Reconstruction

Jo Schlemper, Jose Caballero, Joseph V. Hajnal, Anthony N. Price, Daniel Rueckert

A cascade alternated convolutional corrections with enforcement of consistency with acquired k-space samples. For dynamic cardiac MRI, neighboring frames also provided information for joint reconstruction. In the authors' undersampling experiments the method better preserved anatomy than the reported comparators and reconstructed complete sequences in under ten seconds.

SignificanceThe cascade was an influential example of pairing learned corrections with repeated data consistency steps. It also demonstrated how temporal information could supplement undersampled measurements. Later experimental reviews of MRI reconstruction retained cascaded networks as a distinct comparison class.

Key2018arXiv1,345 citations

fastMRI: An Open Dataset and Benchmarks for Accelerated MRI

Jure Zbontar, Florian Knoll, Anuroop Sriram, Matthew J. Muckley, Mary Bruno, Aaron Defazio

The initial fastMRI report specified single-coil and multicoil knee reconstruction tasks, with fourfold and eightfold retrospective undersampling and common scoring metrics. It compared total variation reconstruction and U-Net baselines on the same splits. The U-Net baselines obtained higher test-set structural similarity in both tasks.

SignificanceReference implementations and results made the data release usable as a shared reconstruction benchmark. The 2019 fastMRI competition used the resource to organize single-coil and multicoil tracks and added radiologist review to numerical screening, extending the initial experimental protocol.

Followed byKnoll 2020

Landmark2018Nature1,965 citations

Image reconstruction by domain-transform manifold learning

Bo Zhu, Jeremiah Z. Liu, Stephen F. Cauley, Bruce R. Rosen, Matthew S. Rosen

AUTOMAP used dense and convolutional layers to learn a mapping from sensor measurements to images. The authors evaluated the design with several MRI sampling trajectories and additional imaging simulations. In the demonstrated settings the learned mapping reduced noise or artifacts, and the paper examined the learned intermediate representations.

SignificanceAUTOMAP became a widely cited instance of learning the sensor-to-image transformation directly. The parallel MRI survey places such mappings alongside architectures that retain the acquisition operator, helping readers identify where different reconstruction designs incorporate physics, use training data, and enforce consistency.

Landmark2018IEEE Transactions on Medical Imaging1,136 citations

Learned Primal-Dual Reconstruction

Jonas Adler, Ozan Öktem

The method unrolled a primal-dual optimization algorithm and replaced the proximal operations with convolutional networks while retaining the forward imaging operator. It started from measured projection data. Low-dose CT phantom experiments reported gains over filtered back-projection, total variation, and learned post-processing of a conventional reconstruction.

SignificanceThe method supplied a reference implementation of an end-to-end tomographic reconstructor with explicit forward and adjoint operations. It remains a reference for studying how learned updates interact with measured projections and for comparing unrolled reconstruction with image-domain correction.

Landmark2018Magnetic Resonance in Medicine2,036 citations

Learning a variational network for reconstruction of accelerated MRI data

Kerstin Hammernik, Teresa Klatzer, Erich Kobler, Michael P. Recht, Daniel K. Sodickson … Florian Knoll

The network unrolled gradient updates of a variational model for multicoil MRI, learning its filters, activation functions, and weights for the measured-data terms. It was tested on retrospectively and prospectively undersampled knees. Quantitative comparisons and a reader study supported the results for fourfold regular undersampling.

SignificanceThe variational network made the parallel MRI acquisition model and the learned image prior explicit within a single trainable system. The later end-to-end variational network developed this design further by incorporating coil sensitivity estimation in the same reconstruction model.

Builds onLustig 2007 Followed bySriram 2020

Notable2019FDA 510(k) Premarket Notification K183202

Deep Learning Image Reconstruction

GE Medical Systems, LLC

The 510(k) record covers the CT reconstruction option that produces TrueFidelity images. The manufacturer integrated a neural network into the scanner's raw-data reconstruction chain and evaluated image properties including noise texture. In April 2019 the FDA determined that the option was substantially equivalent to legally marketed devices.

SignificanceThe record provides primary documentation of a commercial scanner implementation and its intended use. Subsequent phantom testing measured how TrueFidelity affected noise power spectra, spatial resolution, and task-based detectability over different conditions, supplying an independent comparison with iterative reconstruction.

Key2019CVPR 2019353 citations

DuDoNet: Dual Domain Network for CT Metal Artifact Reduction

Wei-An Lin, Haofu Liao, Cheng Peng, Xiaohang Sun, Jingdan Zhang … Shaohua Kevin Zhou

DuDoNet corrected metal-corrupted sinograms and refined the resulting CT images within one trainable network. A differentiable Radon inversion layer connected the two stages. In the reported experiments, joint processing improved detail recovery and reduced residual and secondary artifacts relative to single-domain approaches.

SignificanceDuDoNet provided a concrete dual-domain baseline for learned metal artifact reduction. Later work on deep sinogram completion with an image prior compared against it when studying how projection continuity at the metal trace boundary affects artifacts after reconstruction.

Landmark2019IEEE Transactions on Medical Imaging1,490 citations

MoDL: Model-Based Deep Learning Architecture for Inverse Problems

Hemant K. Aggarwal, Merry P. Mani, Mathews Jacob

MoDL alternated a learned convolutional regularizer with steps that fit the measured data, sharing the convolutional weights across iterations. A conjugate gradient block solved the data consistency subproblem. In undersampled MRI experiments, the solver improved convergence per iteration when available memory restricted the network depth.

SignificanceWeight sharing made it possible to change the number of reconstruction steps while holding the number of learned parameters fixed. The subsequent parallel MRI survey uses MoDL to illustrate the combination of an explicit forward model and a learned regularizer.

Landmark2020IEEE Transactions on Pattern Analysis and Machine Intelligence1,028 citations

ADMM-CSNet: A Deep Learning Approach for Image Compressive Sensing

Yan Yang, Jian Sun, Huibin Li, Zongben Xu

The authors unrolled alternating-direction optimization into two trainable architectures for recovering images from sparse measurements. They learned the transforms and model and solver parameters together. On complex MRI and real-valued natural images, the trained networks delivered competitive reconstruction accuracy and speed in the reported comparisons.

SignificanceThe paper extended the 2016 Deep ADMM-Net proposal into a broader family of trainable solvers. It is a reference for unfolding the steps of an explicit inverse problem solver into layers, a design also seen in parallel MRI variational networks and later model-based architectures.

Key2020Magnetic Resonance in Medicine312 citations

Advancing machine learning for MR image reconstruction with an open competition: Overview of the 2019 fastMRI challenge

Florian Knoll, Tullie Murrell, Anuroop Sriram, Nafissa Yakubova, Jure Zbontar, Michael Rabbat

The paper reports the single-coil and multicoil tracks of the 2019 fastMRI knee reconstruction challenge. Submissions were first screened by structural similarity and shortlisted reconstructions then went to radiologists for review. Examples included a small osteophyte and a meniscal tear that could be obscured in accelerated reconstructions.

SignificanceThe competition turned the data release into a comparison across teams and exposed the limits of measuring reconstruction quality by image similarity alone. The 2020 brain challenge continued the use of numerical screening and reader review while adding a transfer track and a review focused on pathology.

Builds onZbontar 2018, Knoll 2020

Key2020IEEE Signal Processing Magazine514 citations

Deep-Learning Methods for Parallel Magnetic Resonance Imaging Reconstruction: A Survey of the Current Approaches, Trends, and Issues

Florian Knoll, Kerstin Hammernik, Chi Zhang, Steen Moeller, Thomas Pock … Mehmet Akçakaya

The review explains linear and nonlinear parallel MRI reconstruction from image-domain and k-space perspectives. It describes ways to use neural networks as learned image regularizers or as interpolators for missing k-space measurements. It also discusses measurement consistency, public benchmarks, and performance across acquisition conditions.

SignificanceThis widely cited technical reference ties learning methods to the physics of multicoil MRI. It supplies a common vocabulary for comparing image enhancement, direct reconstruction and methods that explicitly enforce data consistency, and documents the early availability of benchmarks for testing those differences.

Key2020MICCAI 2020 (LNCS 12262)539 citations

End-to-End Variational Networks for Accelerated MRI Reconstruction

Anuroop Sriram, Jure Zbontar, Tullie Murrell, Aaron Defazio, C. Lawrence Zitnick … Patricia Johnson

The end-to-end variational network estimated coil sensitivity maps and reconstructed undersampled multicoil MRI in a single trainable architecture. Cascaded refinement used learned image regularization and consistency with measured k-space. The paper reported better reconstruction scores than its comparators on fastMRI knee and brain data.

SignificanceThe architecture brought coil sensitivity estimation into the optimization of the reconstruction system. The fastMRI project distributed a Variational Network implementation, giving researchers an inspectable baseline for experiments on multicoil data and a reproducible reference when comparing alternative reconstruction stages.

Builds onHammernik 2018

Landmark2020Radiology: Artificial Intelligence606 citations

fastMRI: A Publicly Available Raw k-Space and DICOM Dataset of Knee Images for Accelerated MR Image Reconstruction Using Machine Learning

Florian Knoll, Jure Zbontar, Anuroop Sriram, Matthew J. Muckley, Mary Bruno, Aaron Defazio

The fastMRI knee release provided multicoil raw k-space measurements from 1,594 examinations and a separate collection of clinical DICOM image series. Its vendor-neutral measurement format made retrospective undersampling and comparison against fully sampled reconstructions possible using common data instead of locally acquired raw scans.

SignificanceFastMRI supported reproducible comparisons by making measurements available alongside reference images. The 2019 knee challenge used this release, and the later brain challenge broadened the benchmark to include pathology-centered reader evaluations and a track for scanners outside the training data.

Followed byKnoll 2020

Key2020Proceedings of the National Academy of Sciences1,000 citations

On instabilities of deep learning in image reconstruction and the potential costs of AI

Vegard Antun, Francesco Renna, Clarice Poon, Ben Adcock, Anders C. Hansen

The authors tested learned reconstruction algorithms by applying small perturbations, introducing localized structures, and varying the number of samples. They documented examples of visible artifacts, missed small structures, and worse reconstructions when additional measurements were provided. The paper released software for reproducing the stability tests.

SignificanceThe study turned stability into a concrete evaluation problem and published tests for failures that average reconstruction scores can miss. The subsequent fastMRI brain challenge documented related failure modes in highly ranked submissions, including false structures in images with high structural similarity.

Key2020Magnetic Resonance in Medicine436 citations

Self‐supervised learning of physics‐guided reconstruction neural networks without fully sampled reference data

Burhaneddin Yaman, Seyed Amir Hossein Hosseini, Steen Moeller, Jutta Ellermann, Kâmil Uğurbil, Mehmet Akçakaya

SSDU split the acquired k-space samples into two disjoint sets. One supplied data consistency within a physics-guided network and the other defined the training loss. On fourfold accelerated knee MRI, results were close to fully supervised reconstruction. The authors also evaluated prospectively undersampled brain data.

SignificanceThe paper established a way to train physics-guided reconstruction from the kind of incomplete measurements used at deployment. The later multi-mask SSDU study directly extended its measurement partitioning scheme to make fuller use of samples available within each scan.

Notable2020FDA 510(k) Premarket Notification K193282

SIGNA Premier

GE Healthcare (GE Medical Systems, LLC)

On April 10, 2020, the FDA found the SIGNA Premier MRI scanner substantially equivalent with the addition of its AIR Recon DL software feature. The submission described phantom tests and blinded radiologist readings that assessed signal-to-noise ratio, sharpness, lesion conspicuity, and image quality at shorter acquisition times.

SignificanceThe clearance documents scanner integration of learned reconstruction in commercial MRI. A subsequent outpatient implementation study included AIR Recon DL among the reconstruction products deployed and measured examination and turnaround times before and after implementation in routine practice.

Key2020American Journal of Roentgenology188 citations

Using Deep Learning to Accelerate Knee MRI at 3 T: Results of an Interchangeability Study

Michael P. Recht, Jure Zbontar, Daniel K. Sodickson, Florian Knoll, Nafissa Yakubova, Anuroop Sriram

Six readers compared standard 3 T knee MRI with images reconstructed from retrospectively undersampled data. Undersampling simulated a 3.49-fold speedup over fully sampled acquisition and a 1.88-fold speedup over standard parallel acquisition. The images met the study's interchangeability criterion for internal derangement of the knee, and readers favored the accelerated images for image quality.

SignificanceThe study evaluated whether reconstructed scans could substitute for standard scans on a specified diagnostic task. Its reader-based interchangeability design supplied clinical evidence that complemented fastMRI's image similarity metrics and defined the setting in which the replacement was tested.

Notable2021IEEE Transactions on Medical Imaging184 citations

Deep Sinogram Completion With Image Prior for Metal Artifact Reduction in CT Images

Lequan Yu, Zhicheng Zhang, Xiaomeng Li, Lei Xing

The method produced an image prior and projected it forward differentiably to guide a second network that repaired metal-corrupted sinogram values. Filtered back-projection yielded the final image. Experiments with simulated and real artifacts examined projection continuity around metal traces and reported reduced artifacts relative to the comparison methods.

SignificanceThe paper showed how an estimated image could guide a projection-space correction and how that correction could be tested on both simulated and real artifacts. The differentiable forward operator allowed the prior-image and sinogram networks to be optimized jointly.

Key2021IEEE Transactions on Medical Imaging485 citations

Results of the 2020 fastMRI Challenge for Machine Learning MR Image Reconstruction

Matthew J. Muckley, Bruno Riemenschneider, Alireza Radmanesh, Sunwoo Kim, Geunu Jeong, Jingyu Ko

The second fastMRI challenge used raw clinical brain MRI and included a transfer track for scanners outside the training set. Radiologists reviewed pathological findings, complementing quantitative image similarity scores. Some high-scoring reconstructions contained a false vessel or a bright line resembling a cerebrospinal fluid cleft.

SignificanceThe challenge incorporated scanner transfer and preservation of pathology into a public benchmark. Its documented failures give concrete examples for understanding when similarity scores and clinical judgments diverge, and for designing evaluations that examine individual structures in reconstructed images.

Landmark2021ICLR 20218,230 citations

Score-Based Generative Modeling through Stochastic Differential Equations

Yang Song, Jascha Sohl-Dickstein, Diederik P. Kingma, Abhishek Kumar, Stefano Ermon, Ben Poole

The authors unified score-based models and diffusion in continuous time using stochastic differential equations. A learned time-dependent score specified the reverse process. The framework supported predictor-corrector sampling and a probability-flow ordinary differential equation, and the experiments included unconditional generation and imaging inverse problems.

SignificanceThe continuous-time formulation made it possible to reason about the learned prior and numerical solver within the same model. The later medical inverse problems study explicitly applied this score framework with physical measurement operators for CT and MRI.

Followed byChung 2022, Song 2022

Key2022Medical Image Analysis671 citations

Score-based diffusion models for accelerated MRI

Hyungjin Chung, Jong Chul Ye

The method learned a score model from fully sampled MR images and combined diffusion sampling with k-space data consistency during reconstruction. The authors evaluated the same learned prior with single-coil and multicoil acquisitions and different undersampling schemes, reporting improvements over the reconstruction methods they compared.

SignificanceThe paper showed that a single independently learned image prior could be applied to several acquisition settings. Subsequent work on adaptive diffusion priors continued this line of investigation by examining how the learned prior could be adjusted at test time for individual accelerated MRI acquisitions.

Builds onSong 2021

Key2022ICLR 2022865 citations

Solving Inverse Problems in Medical Imaging with Score-Based Generative Models

Yang Song, Liyue Shen, Lei Xing, Stefano Ermon

The researchers learned a generative score prior from medical images and introduced the measurements and their forward operator during sampling at test time. Tests included CT and MRI inverse problems. The study reported comparable or improved reconstruction in several tasks and stronger generalization to changed measurement processes.

SignificanceThe study used a common framework to test score priors across tomographic and MR measurement models. By varying the operator used at inference, it provided a direct evaluation of whether a learned prior could support multiple reconstruction tasks without acquisition-specific paired training.

Builds onSong 2021

Key2023Radiology528 citations

Deep Learning Image Reconstruction for CT: Technical Principles and Clinical Prospects

Lennart R. Koetzier, Domenico Mastrodicasa, Timothy P. Szczykutowicz, Niels R. van der Werf, Adam S. Wang, Veit Sandfort

The review traced clinical CT reconstruction from filtered back-projection through iterative and learned methods. It described commercial training targets and summarized evidence for noise texture, spatial resolution, and dose reduction across applications. It also examined metal artifact reduction and prospective uses in photon-counting CT.

SignificanceThe review assembled early clinical evidence for scanner-integrated deep learning reconstruction and explained why different training targets can yield different image properties. It provides a reference for tracing commercial implementations to their underlying studies and for comparing results across protocols and clinical tasks.

Key2023Medical Image Analysis1,207 citations

Diffusion models in medical imaging: A comprehensive survey

Amirhossein Kazerouni, Ehsan Khodapanah Aghdam, Moein Heidari, Reza Azad, Mohsen Fayyaz … Dorit Merhof

This survey introduced diffusion training and sampling, then organized early medical imaging studies by task. It covered two- and three-dimensional generation, translation, reconstruction, segmentation, and anomaly detection. Its task tables documented datasets, conditioning inputs, and evaluation methods, alongside practical issues such as computational cost.

SignificanceThe review became a widely cited entry point to early medical diffusion research. Its cross-task organization makes it possible to trace which assumptions and evaluation designs were used in the underlying studies, helping distinguish image synthesis questions from reconstruction with measured data.

Key2024ECCV 2024 (LNCS 15118)12 citations

Task-Driven Uncertainty Quantification in Inverse Problems via Conformal Prediction

Jeffrey Wen, Rizwan Ahmad, Philip Schniter

The authors use conformal calibration to quantify uncertainty that undersampling and reconstruction contribute to a downstream task. In accelerated MRI experiments they construct intervals for the task score that would be obtained from the fully sampled image and simulate stopping acquisition according to interval width.

SignificanceThis study connects reconstruction uncertainty directly to a downstream scalar output, giving investigators a target different from pixel-level error. The accelerated MRI experiments show how the usefulness of additional measurements can be evaluated in terms of an intended imaging task.