MG·LB · Key works

Evaluation, reporting standards and regulation

In the exhibits12.9 Regulation and clinical evidence13.1 Generalization and evaluation13.2 Human–AI collaboration and the radiologist's role

Landmark1945Ecology13,933 citations

Measures of the Amount of Ecologic Association Between Species

Lee R. Dice

Dice studied ecological association using records of where two species occurred. One coefficient normalized twice the number of joint occurrences by the sum of the two species' separate occurrence counts. The paper discussed ways to measure association and interpret unequal occurrence frequencies.

SignificanceThe same form became a standard way to measure overlap between a predicted mask and its reference in medical image segmentation. Taha and Hanbury's metric analysis discusses its relationship to alternative overlap measures and guidance on choosing them.

Landmark1982Radiology24,806 citations

The meaning and use of the area under a receiver operating characteristic (ROC) curve.

James A. Hanley, Barbara J. McNeil

The paper interpreted the area under an ROC curve from graded readings or continuous scores as the probability that a randomly selected affected case ranks above an unaffected case. Relating the probability to the Wilcoxon statistic yielded practical approximations for standard errors and study sample sizes.

SignificanceThe interpretation gave reader studies a common meaning for a summary across rating thresholds and a way to plan precision. Later clinical evaluation guidance places that summary alongside threshold-specific performance, which is needed when a scoring system will be used at a defined operating point.

Followed byHanley 1983

Key1983Radiology7,586 citations

A Method of Comparing the Areas under Receiver Operating Characteristic Curves Derived from the Same Cases

James A. Hanley, Barbara J. McNeil

The authors compared ROC areas estimated from the same patients under two reading conditions. Using a binormal assumption, they derived a table that converts correlation between paired ratings into correlation between areas. Accounting for that correlation in the standard error of the area difference can increase statistical power.

SignificanceThis paper provided a parametric method for accounting for shared cases in reader or test comparisons. A later methodological study of sample size and power still used the Hanley–McNeil calculation to estimate the variance of differences between correlated ROC areas for continuous diagnostic scores.

Builds onHanley 1982

Landmark1988Biometrics25,065 citations

Comparing the Areas under Two or More Correlated Receiver Operating Characteristic Curves: A Nonparametric Approach

Elizabeth R. DeLong, David M. DeLong, Daniel L. Clarke-Pearson

Diagnostic tests evaluated on the same participants yield correlated estimates of ROC area. DeLong and colleagues used generalized U-statistics to estimate the covariance matrix of the empirical areas. The resulting nonparametric method compares two or more areas while accounting for the paired study design.

SignificanceThe method is a widely used statistical baseline for comparing tests or readers on shared cases, with implementations in statistical software. Studies of chest radiograph classifier generalization have used it to assess differences in ROC area across their planned test comparisons.

Key1989Medical Physics221 citations

Maximum likelihood analysis of free-response receiver operating characteristic (FROC) data

Dev P. Chakraborty

For reader studies that require localization, the paper modeled the scores of signal marks and the production of false-positive marks in free-response ROC data. FROCFIT estimated model parameters and their uncertainties with maximum likelihood. The author reported fits to several experimental data sets.

SignificanceThe paper supplied a statistical model for experiments in which readers can mark several locations per image. Free-response analysis later informed reader-based imaging benchmarks, including the low-dose CT challenge that used a jackknife alternative for evaluating marks of liver metastases.

Key1993IEEE Transactions on Pattern Analysis and Machine Intelligence5,184 citations

Comparing images using the Hausdorff distance

Daniel P. Huttenlocher, Gregory A. Klanderman, William J. Rucklidge

The paper used Hausdorff distance between point sets to compare shapes without first assigning point-to-point correspondences. It developed efficient search algorithms for translating a binary model relative to an image. The authors extended the techniques to rigid motion and partial matching.

SignificanceThe work gave a practical implementation of Hausdorff distance for comparing digital shapes. Medical segmentation evaluation subsequently used the distance and its robust variants to characterize contour displacement, providing information complementary to overlap when predicted boundaries are offset.

Key2004IEEE Transactions on Medical Imaging2,365 citations

Simultaneous Truth and Performance Level Estimation (STAPLE): An Algorithm for the Validation of Image Segmentation

Simon K. Warfield, Kelly H. Zou, William M. Wells III

STAPLE starts with several human or algorithm-generated segmentations. It uses expectation maximization to estimate the probability of a reference label at each voxel while estimating sensitivity and specificity for each input segmentation. The authors demonstrated the approach on synthetic and clinical images.

SignificanceThe approach made it possible to estimate rater reliability and a consensus reference within the same model. ITK provides an implementation that produces a probability map from multiple segmentations, allowing the procedure to be reused in validation and label-fusion workflows.

Key2009NeuroImage2,487 citations

Evaluation of 14 nonlinear deformation algorithms applied to human brain MRI registration

Arno Klein, Jesper Andersson, Babak A. Ardekani, John Ashburner, Brian Avants, Ming-Chang Chiang

The authors compared 14 nonlinear algorithms using 80 manually labeled brain scans and more than 45,000 registrations with common linear initialization. They compared alignment using overlap and distance measures. ART and SyN were in the top statistical rank across all four label sets and ranking analyses.

SignificanceThe shared scans, preprocessing, and anatomical labels enabled direct comparison across registration software. A subsequent evaluation of volume and surface registration used the results to select ART and SyN for the volume-based comparisons, carrying the benchmark into a different experimental design.

Key2015BMC Medical Imaging3,720 citations

Metrics for evaluating 3D medical image segmentation: analysis, selection, and tool

Abdel Aziz Taha, Allan Hanbury

The authors compared twenty metrics for three-dimensional medical segmentation, reconciled differences in definitions, and specified fuzzy extensions for masks with fractional voxel membership. They released an open implementation designed to handle volumes as large as whole-body MRI or CT with practical memory and runtime requirements.

SignificanceThe paper gave volumetric segmentation studies a shared technical reference and implementation for overlap, distance, and related measures. Metrics Reloaded later developed a broader selection framework organized around the task, the structure under study, and the consequences of different errors.

Landmark2015BMJ4,584 citations

STARD 2015: an updated list of essential items for reporting diagnostic accuracy studies

Patrick M. Bossuyt, Johannes B. Reitsma, David E. Bruns, Constantine A. Gatsonis, Paul P. Glasziou, Les Irwig

STARD 2015 updated a reporting checklist for diagnostic accuracy studies using evidence about sources of bias and variation. The thirty items cover participant selection, the index test, the reference standard, and how data were analyzed and reported, so readers can appraise the study's estimated accuracy.

SignificanceSTARD established a common reporting framework for diagnostic accuracy studies and is indexed by EQUATOR for that study design. The 2025 extension for algorithm-based tests used the 2015 checklist as its starting point and added considerations for model-based evaluations.

Followed bySounderajah 2025

Key2017Medical Physics425 citations

Low-dose CT for the detection and classification of metastatic liver lesions: Results of the 2016 Low Dose CT Grand Challenge

Cynthia H. McCollough, Adam C. Bartley, Rickey E. Carter, Baiyu Chen, Tammy A. Drees, Phillip Edwards

The Low Dose CT Grand Challenge supplied common contrast-enhanced CT cases to groups testing image-space denoising or iterative reconstruction. Participants reconstructed twenty quarter-dose test examinations. Eleven blinded readers marked liver metastases, with substantial differences in reader scores across the submitted reconstruction and denoising methods.

SignificanceThe competition tied reconstruction evaluation to the clinical task of detecting liver metastases. The Cancer Imaging Archive's larger collection includes 13 of the challenge test cases. A separate release provides all 30 training and test cases in the same standardized projection format for further comparisons.

Notable2017Official Journal of the European Union, L 117

Regulation (EU) 2017/745 of the European Parliament and of the Council of 5 April 2017 on medical devices, amending Directive 2001/83/EC, Regulation (EC) No 178/2002 and Regulation (EC) No 1223/2009 and repealing Council Directives 90/385/EEC and 93/42/EEC (Text with EEA relevance.)

European Parliament and Council of the European Union

The Medical Device Regulation establishes rules for classification, clinical evaluation, conformity assessment, and post-market surveillance of devices. Article 83 calls for manufacturers to maintain a surveillance system proportionate to device type and risk, and related articles specify planning and reporting obligations.

SignificanceThe regulation supplies the device-law basis for conformity assessment and post-market surveillance of qualifying imaging software in the European Union. The 2024 regulation lists it in Annex I, linking the high-risk system classification to product legislation and relevant conformity assessment requirements.

Key2018MICCAI 2018 (LNCS 11070)487 citations

Distribution Matching Losses Can Hallucinate Features in Medical Image Translation

Joseph Paul Cohen, Margaux Luck, Sina Honari

The authors varied the frequency of abnormalities between source and target image distributions and tested how CycleGAN translation responded. The experiments demonstrated that matching the target distribution could remove an abnormal feature present in the input or introduce a feature resembling pathology.

SignificanceThe study gave controlled evidence that a plausible translated image can change pathology when the target cohort has different disease prevalence. It provided a reproducible way to evaluate patient-level fidelity separately from visual realism or resemblance to a target image collection.

Builds onZhu 2017

Landmark2018PLOS Medicine2,399 citations

Variable generalization performance of a deep learning model to detect pneumonia in chest radiographs: A cross-sectional study

John R. Zech, Marcus A. Badgeley, Manway Liu, Anthony B. Costa, Joseph J. Titano, Eric Karl Oermann

The authors assessed pneumonia classifiers across three healthcare systems. Ranking by hospital alone reached an AUC of 0.861 in a pooled two-hospital dataset. The model trained on that pool achieved 0.931 on its internal test set and 0.815 at a third institution.

SignificanceThe study quantified a source of distribution shift by combining hospital identification experiments with testing at another institution. Subsequent work on COVID-19 radiographs cites it as evidence that a model can obtain high scores from acquisition-related correlates of disease prevalence.

Landmark2018Nature Communications506 citations

Why rankings of biomedical image analysis competitions should be interpreted with care

Lena Maier-Hein, Matthias Eisenmann, Annika Reinke, Sinan Onogur, Marko Stankovic, Patrick Scholz

The authors examined published biomedical imaging challenges and recomputed rankings under alternative conditions. Rankings often changed when the test cases, reference observer, or aggregation scheme changed. The survey also found that reports frequently omitted methodological information required to reproduce the comparisons.

SignificanceThe analysis showed how challenge design choices can materially change the resulting leaderboard. It informed structured challenge proposals at MICCAI and provided the empirical basis for the BIAS guidance on documenting data, reference standards, assessment measures, and rankings.

Followed byMaier-Hein 2020

Notable2019FDA 510(k) Premarket Notification K183202

Deep Learning Image Reconstruction

GE Medical Systems, LLC

The 510(k) record covers the CT reconstruction option that produces TrueFidelity images. The manufacturer integrated a neural network into the scanner's raw-data reconstruction chain and evaluated image properties including noise texture. In April 2019 the FDA determined that the option was substantially equivalent to legally marketed devices.

SignificanceThe record provides primary documentation of a commercial scanner implementation and its intended use. Subsequent phantom testing measured how TrueFidelity affected noise power spectra, spatial resolution, and task-based detectability over different conditions, supplying an independent comparison with iterative reconstruction.

Key2020Magnetic Resonance in Medicine312 citations

Advancing machine learning for MR image reconstruction with an open competition: Overview of the 2019 fastMRI challenge

Florian Knoll, Tullie Murrell, Anuroop Sriram, Nafissa Yakubova, Jure Zbontar, Michael Rabbat

The paper reports the single-coil and multicoil tracks of the 2019 fastMRI knee reconstruction challenge. Submissions were first screened by structural similarity and shortlisted reconstructions then went to radiologists for review. Examples included a small osteophyte and a meniscal tear that could be obscured in accelerated reconstructions.

SignificanceThe competition turned the data release into a comparison across teams and exposed the limits of measuring reconstruction quality by image similarity alone. The 2020 brain challenge continued the use of numerical screening and reader review while adding a transfer track and a review focused on pathology.

Builds onZbontar 2018, Knoll 2020

Key2020BMJ1,464 citations

Artificial intelligence versus clinicians: systematic review of design, reporting standards, and claims of deep learning studies

Myura Nagendran, Yang Chen, Christopher A. Lovejoy, Anthony C. Gordon, Matthieu Komorowski, Hugh Harvey

The systematic review examined study design, reporting, and risk of bias for comparisons of diagnostic deep learning with expert clinicians. Of 81 nonrandomized studies, nine were prospective and six tested systems in clinical settings. The authors also searched for registered randomized trials.

SignificanceThe review quantified the gap between retrospective expert comparisons and tests of clinical use, and examined whether published claims were supported by study design. Its separation of study designs provides a reference for assessing how subsequent imaging evaluation has changed.

Key2020Medical Image Analysis158 citations

BIAS: Transparent reporting of biomedical image analysis challenges

Lena Maier-Hein, Annika Reinke, Michal Kozubek, Anne L. Martel, Tal Arbel, Matthias Eisenmann

The paper presented a checklist for reporting biomedical image analysis competitions. It described the development process and specified what to disclose about the task, participants, data, reference labels, evaluation measures, and rankings so readers can understand or reproduce the comparison.

SignificanceThe checklist translated calls for challenge transparency into explicit reporting items. Its inclusion in the EQUATOR reporting-guideline library gives organizers and reviewers a shared reference for checking whether a published competition documents data handling, scoring, and ranking decisions.

Builds onMaier-Hein 2018

Landmark2020Radiology: Artificial Intelligence1,789 citations

Checklist for Artificial Intelligence in Medical Imaging (CLAIM): A Guide for Authors and Reviewers

John Mongan, Linda Moy, Charles E. Kahn Jr.

CLAIM presented a reporting checklist for medical imaging studies using machine learning. Its items addressed data sources and partitions, annotation and reference standards, model design and training, and performance evaluation. The paper explained the items for authors preparing reports and for reviewers appraising what was disclosed.

SignificanceThe checklist made imaging-specific details, such as annotation and how imaging data were partitioned, explicit reporting items. The 2024 revision retained that framework and is listed by EQUATOR, with updated guidance on acquisition and testing terminology.

Followed byTejani 2024

Landmark2020Nature Medicine1,138 citations

Guidelines for clinical trial protocols for interventions involving artificial intelligence: the SPIRIT-AI extension

Samantha Cruz Rivera, Xiaoxuan Liu, An-Wen Chan, Alastair K. Denniston, Melanie J. Calvert, on behalf of the SPIRIT-AI and CONSORT-AI Working Group

The SPIRIT extension used literature review, Delphi consultation, and consensus to specify how trial protocols should describe an algorithmic intervention. The additional items cover system version, input and output handling, the setting and skills required for use, and the planned approach to analyzing errors.

SignificanceThe guideline brought the operating conditions and planned analysis of algorithm errors into prospectively reported protocols. EQUATOR lists it under trial protocols alongside a companion CONSORT extension for reporting completed studies, providing aligned checks at two stages of a trial.

Key2020ACM CHIL 2020723 citations

Hidden Stratification Causes Clinically Meaningful Failures in Machine Learning for Medical Imaging

Luke Oakden-Rayner, Jared Dunnmon, Gustavo Carneiro, Christopher Ré

The authors examined clinically important subsets that had been combined under broad dataset labels. They compared several ways of finding performance differences, including expert-defined subclasses and error review. Experiments on simulated and medical imaging data identified gaps associated with low prevalence, noisy labels, subtle findings, and spurious correlates.

SignificanceThe paper made variation within a nominal diagnostic class an explicit evaluation problem. A later study of a commercial chest radiograph model assessed pneumothorax performance by clinical strata such as the presence of a drain, extending the investigation to a different system.

Key2020Proceedings of the National Academy of Sciences1,000 citations

On instabilities of deep learning in image reconstruction and the potential costs of AI

Vegard Antun, Francesco Renna, Clarice Poon, Ben Adcock, Anders C. Hansen

The authors tested learned reconstruction algorithms by applying small perturbations, introducing localized structures, and varying the number of samples. They documented examples of visible artifacts, missed small structures, and worse reconstructions when additional measurements were provided. The paper released software for reproducing the stability tests.

SignificanceThe study turned stability into a concrete evaluation problem and published tests for failures that average reconstruction scores can miss. The subsequent fastMRI brain challenge documented related failure modes in highly ranked submissions, including false structures in images with high structural similarity.

Landmark2020Nature Medicine1,949 citations

Reporting guidelines for clinical trial reports for interventions involving artificial intelligence: the CONSORT-AI extension

Xiaoxuan Liu, Samantha Cruz Rivera, David Moher, Melanie J. Calvert, Alastair K. Denniston, on behalf of the SPIRIT-AI and CONSORT-AI Working Group

The CONSORT extension added fourteen reporting items to the core randomized trial checklist for studies involving an algorithmic intervention. The items describe the system version, suitability and handling of inputs, how users interacted with outputs in the clinical workflow, and analysis of errors.

SignificanceThe checklist standardizes how reports describe the algorithmic component of a trial, enabling comparison of the tested versions and workflows. Clinical evaluation guidance for medical diagnosis lists the extension among the relevant reporting frameworks for large trials of these interventions.

Notable2020FDA 510(k) Premarket Notification K193282

SIGNA Premier

GE Healthcare (GE Medical Systems, LLC)

On April 10, 2020, the FDA found the SIGNA Premier MRI scanner substantially equivalent with the addition of its AIR Recon DL software feature. The submission described phantom tests and blinded radiologist readings that assessed signal-to-noise ratio, sharpness, lesion conspicuity, and image quality at shorter acquisition times.

SignificanceThe clearance documents scanner integration of learned reconstruction in commercial MRI. A subsequent outpatient implementation study included AIR Recon DL among the reconstruction products deployed and measured examination and turnaround times before and after implementation in routine practice.

Key2021IEEE Transactions on Medical Imaging485 citations

Results of the 2020 fastMRI Challenge for Machine Learning MR Image Reconstruction

Matthew J. Muckley, Bruno Riemenschneider, Alireza Radmanesh, Sunwoo Kim, Geunu Jeong, Jingyu Ko

The second fastMRI challenge used raw clinical brain MRI and included a transfer track for scanners outside the training set. Radiologists reviewed pathological findings, complementing quantitative image similarity scores. Some high-scoring reconstructions contained a false vessel or a bright line resembling a cerebrospinal fluid cleft.

SignificanceThe challenge incorporated scanner transfer and preservation of pathology into a public benchmark. Its documented failures give concrete examples for understanding when similarity scores and clinical judgments diverge, and for designing evaluations that examine individual structures in reconstructed images.

Key2021Nature Medicine1,387 citations

Underdiagnosis bias of artificial intelligence algorithms applied to chest radiographs in under-served patient populations

Laleh Seyyed-Kalantari, Haoran Zhang, Matthew B. A. McDermott, Irene Y. Chen, Marzyeh Ghassemi

The authors trained chest radiograph classifiers on three large datasets and a multisource combination, then measured how often models assigned a normal label to patients with findings. Their analysis compared demographic groups and found that disparities could be greater for intersecting underserved groups.

SignificanceBy measuring underdiagnosis as a distinct outcome, the study showed how aggregate performance can conceal the distribution of missed findings. Its cross-dataset and intersectional comparisons provide a concrete reference for testing how these errors are distributed across populations.

Key2022The Lancet Digital Health878 citations

AI recognition of patient race in medical imaging: a modelling study

Judy Wawira Gichoya, Imon Banerjee, Ananth Reddy Bhimireddy, John L. Burns, Leo Anthony Celi, Li-Ching Chen

The authors train models to predict self-reported race from medical images and test them across institutions and several modalities. They assess proposed proxy variables and perturb the images to investigate the source of the signal. The tested individual proxies did not account for the model's discrimination.

SignificanceThe finding shows why withholding demographic input fields does not prevent a model from accessing population-associated signals in the image itself. Cross-modality and external testing made the paper a reference for auditing fairness in medical image models.

Key2022Science Advances837 citations

Disparities in dermatology AI performance on a diverse, curated clinical image set

Roxana Daneshjou, Kailas Vodrahalli, Roberto A. Novoa, Melissa Jenkins, Weixin Liang, Veronica Rotemberg

The authors assembled the biopsy-confirmed Diverse Dermatology Images collection and used it to assess classifiers and dermatologist visual labels across skin tones. Models performed worse on darker skin and uncommon diseases. Fine-tuning on the more diverse collection reduced the measured disparity between skin tones.

SignificanceThe public image collection and pathology reference enabled subgroup evaluation without relying on the visual labels used to train many existing models. Testing both classifiers and human visual labels gave subsequent work a way to examine label quality alongside performance disparities.

Key2022BMJ953 citations

Reporting guideline for the early stage clinical evaluation of decision support systems driven by artificial intelligence: DECIDE-AI

Baptiste Vasey, Myura Nagendran, Bruce Campbell, David A. Clifton, Gary S. Collins, Spiros Denaxas

The DECIDE group developed reporting guidance for early clinical evaluations of decision support systems through a modified Delphi process and stakeholder consensus. The checklist has seventeen system-specific items and ten generic items. It addresses workflow, errors, safety, and human factors in small-scale use.

SignificanceThe checklist gives investigators a way to document the first clinical use of a system, including changes to its operation and the circumstances in which errors occur. It addresses a stage between offline evaluation and large randomized trials.

Key2023Radiology527 citations

Automation Bias in Mammography: The Impact of Artificial Intelligence BI-RADS Suggestions on Reader Performance

Thomas Dratsch, Xue Chen, Mohammad Rezazade Mehrizi, Roman Kloeckner, Aline Mähringer-Kunz, Michael Püsken

Twenty-seven radiologists graded fifty mammograms with BI-RADS suggestions attributed to an automated system. Some suggestions were deliberately incorrect. Correct grading declined across all experience groups when the suggestions were wrong, and less experienced readers followed certain incorrect upward suggestions more often.

SignificanceBy controlling whether the suggested category was correct, the study could directly measure how readers responded when assistance misled them. It provided a reader-study design for evaluating automation bias across experience levels in mammography interpretation.

Key2023Insights into Imaging548 citations

CheckList for EvaluAtion of Radiomics research (CLEAR): a step-by-step reporting guideline for authors and reviewers endorsed by ESR and EuSoMII

Burak Kocak, Bettina Baessler, Spyridon Bakas, Renato Cuocolo, Andrey Fedorov, Lena Maier-Hein

An international expert group used a modified Delphi process to develop CLEAR, a 58-item checklist for reporting radiomics studies. It covers data and patient selection, image segmentation and feature extraction, modeling and validation, and disclosure of the availability of data, code, and models.

SignificanceCLEAR gave authors and reviewers a common set of disclosures for the design, validation, and availability of radiomics studies. The European Society of Radiology and the European Society of Medical Imaging Informatics endorsed it, and subsequent society practice recommendations specifically directed researchers to the checklist.

Key2023Patterns396 citations

Evaluating progress in automatic chest X-ray radiology report generation

Feiyang Yu, Mark Endo, Rayan Krishnan, Ian Pan, Andy Tsai, Eduardo Pontes Reis

The study compared automatic report scores with radiologists’ counts of errors. RadGraph F1 scored overlap in clinical entities and relations, while RadCliQ combined measures to estimate error counts. Both aligned more closely with radiologist judgments than several conventional measures of textual similarity.

SignificanceThe study made radiologists’ error judgments an external criterion for choosing report metrics. Subsequent report generation experiments used both RadGraph F1 and RadCliQ to test whether improvements in text generation were accompanied by improvements in the clinical content measured by those scores.

Builds onJain 2021, Smit 2020

Key2023npj Digital Medicine649 citations

Large language models propagate race-based medicine

Jesutofunmi A. Omiye, Jenna C. Lester, Simon Spichak, Veronica Rotemberg, Roxana Daneshjou

The authors repeatedly queried four commercially available language models with questions developed to expose outdated race-based assumptions in medicine. Outputs from every tested model contained examples of potentially harmful race-based claims, and some answers changed when the same question was asked again.

SignificanceThe study gave safety evaluations a concrete way to test the recurrence of harmful medical assumptions through repeated prompts. Its observations show why average question-answering accuracy leaves out both content that can harm particular groups and variability across identical requests.

Key2023Radiology214 citations

Methods for Clinical Evaluation of Artificial Intelligence Algorithms for Medical Diagnosis

Seong Ho Park, Kyunghwa Han, Hye Young Jang, Ji Eun Park, June-Goo Lee … Jaesoon Choi

The review covers external testing, performance measures, and reporting for diagnostic algorithms. It discusses paired designs for comparing interpretations with and without assistance on the same cases and parallel designs for evaluating the effect of an intervention. Radiology examples illustrate reader order, washout, and randomized trial design.

SignificanceThe review gives readers a common reference for linking each clinical question to an appropriate design. Its audit of two radiology journals found paired designs in 22 of 24 studies comparing assisted and unassisted diagnosis, illustrating how the published evidence was produced.

Key2023Medical Image Analysis1,082 citations

Segment anything model for medical image analysis: An experimental study

Maciej A. Mazurowski, Haoyu Dong, Hanxue Gu, Jichen Yang, Nicholas Konz, Yixin Zhang

The authors evaluated the original SAM on 19 medical imaging datasets, comparing prompt designs across modalities and anatomical targets. Overlap varied substantially by task. Box prompts generally performed better than a single point, and some targets with indistinct borders remained difficult.

SignificanceThe study quantified the limits of transferring a natural-image segmenter directly to medical images and helped separate model performance from prompt selection. The later SAM 2 evaluation reused much of its dataset collection and expanded the comparison to volumetric prompts.

Builds onKirillov 2023

Key2024Radiology: Artificial Intelligence1,057 citations

Checklist for Artificial Intelligence in Medical Imaging (CLAIM): 2024 Update

Ali S. Tejani, Michail E. Klontzas, Anthony A. Gatti, John T. Mongan, Linda Moy … CLAIM 2024 Update Panel

The 2024 CLAIM update revised imaging-specific reporting items through expert review, including describing acquisition protocols and clarifying terms for reference standards, internal testing, and external testing. The article explains the scope of the checklist and how each item relates to transparent reporting of imaging studies.

SignificanceRequiring acquisition details makes it easier to assess whether experiments can be reproduced or compared across scanners and protocols. EQUATOR catalogs the updated version, which gives authors and reviewers a shared checklist for the information needed to interpret an imaging study.

Builds onMongan 2020 Followed byD’Antonoli 2026

Key2024Nature Medicine207 citations

Deep learning-aided decision support for diagnosis of skin disease across skin tones

Matthew Groh, Omar Badri, Roxana Daneshjou, Arash Koochek, Caleb Harris … Rosalind Picard

A simulated teledermatology study enrolled 848 specialist and primary-care physicians to propose differential diagnoses from photographs across skin tones. Model support improved overall diagnostic accuracy for both groups, while increasing the difference in accuracy between lighter- and darker-skin images among generalists.

SignificanceThe experiment evaluates the combined physician and model workflow across reader groups and skin tones. It shows why evaluation of the model alone or of the team's aggregate accuracy cannot substitute for subgroup analysis of the actual decisions made with assistance.

Key2024Canadian Association of Radiologists Journal70 citations

Developing, Purchasing, Implementing and Monitoring AI Tools in Radiology: Practical Considerations. A Multi-Society Statement From the ACR, CAR, ESR, RANZCR & RSNA

Adrian P. Brady, Bibb Allen, Jaron Chong, Elmar Kotter, Nina Kottler, John Mongan

Five radiology societies issued joint recommendations on developing, purchasing, implementing, and monitoring clinical software. The statement discusses local assessment, oversight, and the risk of performance drift. It proposes that registries collect model performance, examination parameters, and patient demographics where continuous monitoring is feasible.

SignificanceThe statement makes monitoring operational by connecting changes in performance with information a radiology department can track, such as a scanner or protocol change. The five societies published the same recommendations across their journals, giving clinical teams a shared point of reference for local governance.

Key2024Nature Medicine1,336 citations

Evaluation and mitigation of the limitations of large language models in clinical decision-making

Paul Hager, Friederike Jungmann, Robbie Holland, Kunal Bhagat, Inga Hubrecht, Manuel Knauer

The authors built an interactive evaluation from 2,400 real MIMIC-IV cases involving four abdominal conditions. They tested diagnosis, information gathering, and guideline adherence as information became available. Performance varied with information order, and the systems showed difficulties with laboratory results and following instructions.

SignificanceThe study provided a reproducible evaluation that combined information gathering, diagnostic judgment, and guideline adherence. Its design let researchers vary the order and availability of information and see how the same model behaved under different assumptions about a clinical workflow.

Key2024Nature Medicine295 citations

Heterogeneity and predictors of the effects of AI assistance on radiologists

Feiyang Yu, Alex Moehring, Oishi Banerjee, Tobias Salz, Nikhil Agarwal, Pranav Rajpurkar

The study analyzed algorithm-assisted reading by 140 radiologists across fifteen chest radiograph tasks. Experience, subspecialty, and familiarity with such tools did not reliably predict individual effects. In the aggregate analysis and for several individual findings, erroneous model predictions were associated with poorer reader performance.

SignificanceThe analysis separated aggregate reader performance from the effects for individual readers and findings, and examined model correctness explicitly. That design gives clinical evaluations a way to measure heterogeneity of assistance and to identify errors that affect the combined judgment.

Key2024JAMA Network Open1,129 citations

Large Language Model Influence on Diagnostic Reasoning: A Randomized Clinical Trial

Ethan Goh, Robert Gallo, Jason Hom, Eric Strong, Yingjie Weng, Hannah Kerman

Fifty physicians were randomized to use GPT-4 alongside conventional resources or to use conventional resources alone when working through clinical vignettes. Blinded graders scored diagnosis and reasoning using a standardized rubric. The study found no statistically significant improvement with access to GPT-4.

SignificanceThe trial made the clinician’s performance the main outcome and measured the model by itself separately. This distinction let researchers test whether access to a strong standalone model improves assisted diagnosis and provided a comparison for a later trial on management reasoning.

Notable2024arXiv362 citations

MAIRA-2: Grounded Radiology Report Generation

Shruthi Bannur, Kenza Bouzid, Daniel C. Castro, Anton Schwaighofer, Anja Thieme, Sam Bond-Taylor

MAIRA-2 took current radiographs and available prior images, reports, and examination context as input. It generated findings and attached bounding boxes to findings that could be localized. The authors introduced RadFact to assess whether report sentences were supported by a reference and to score the accompanying spatial predictions.

SignificanceBy attaching a region to a generated statement, the method made that statement’s proposed image evidence inspectable. RadFact operationalized separate checks on textual agreement and spatial localization, giving follow-up reporting methods evaluation targets for both language and visual grounding.

Builds onPérez-García 2025

Landmark2024Nature Methods835 citations

Metrics reloaded: recommendations for image analysis validation

Lena Maier-Hein, Annika Reinke, Patrick Godau, Minu D. Tizabi, Florian Buettner, Evangelia Christodoulou

Metrics Reloaded developed a structured approach to metric selection through a multistage Delphi process. It asks users to describe the task, the target structures, data, and algorithm outputs before choosing metrics for image classification, object detection, semantic segmentation, or instance segmentation.

SignificanceThe framework made criteria for choosing metrics explicit, including the distinction between detecting individual lesions and measuring regions or volumes. Its public tool and companion catalog of pitfalls make those choices traceable in biomedical image analysis benchmarks.

Notable2024The Lancet Digital Health487 citations

Randomised controlled trials evaluating artificial intelligence in clinical practice: a scoping review

Ryan Han, Julián N. Acosta, Zahra Shakeri, John P. A. Ioannidis, Eric J. Topol, Pranav Rajpurkar

This scoping review identified eighty-six randomized trials of machine learning interventions in clinical practice. Seventy reported favorable primary endpoints, which were most often diagnostic yield or diagnostic performance measures. Many studies were single center, and demographic and operational information was reported inconsistently.

SignificanceThe review documented the kinds of outcomes that clinical trials had measured and the information they omitted. This evidence map helps quantify how much of the reported randomized evidence concerns diagnostic performance and how often trials measured outcomes closer to patient benefit.

Notable2024Official Journal of the European Union, L 2024/1689

Regulation (EU) 2024/1689 of the European Parliament and of the Council of 13 June 2024 laying down harmonised rules on artificial intelligence and amending Regulations (EC) No 300/2008, (EU) No 167/2013, (EU) No 168/2013, (EU) 2018/858, (EU) 2018/1139 and (EU) 2019/2144 and Directives 2014/90/EU, (EU) 2016/797 and (EU) 2020/1828 (Artificial Intelligence Act) (Text with EEA relevance)

European Parliament and Council of the European Union

This European Union regulation establishes obligations by system risk. Article 6 addresses systems that are products or product safety components falling under listed legislation and subject to the specified conformity assessment conditions. Requirements for high-risk systems address data governance, technical documentation, human oversight, and post-market monitoring.

SignificanceThe regulation connects certain imaging device software to a cross-sector risk framework in addition to medical device law. The 2026 amending regulation revised application dates and changed provisions affecting some product safety components. The consolidated text records both changes.

Followed byUnion 2026

Key2024Nature Medicine447 citations

The limits of fair medical imaging AI in real-world generalization

Yuzhe Yang, Haoran Zhang, Judy W. Gichoya, Dina Katabi, Marzyeh Ghassemi

The authors studied demographic encodings and subgroup disparities in disease classifiers for radiology, ophthalmology, and dermatology. Mitigation could narrow measured gaps in the original data distribution, while its benefit varied on external datasets. Models with weaker demographic encodings often achieved more consistent fairness across the tested settings.

SignificanceThe study made transfer of a fairness intervention an empirical question by evaluating separate populations and institutions. Its design supports looking at overall discrimination, subgroup performance, and external gaps together when testing mitigation in a new deployment setting.

Landmark2024BMJ7,542 citations

TRIPOD+AI statement: updated guidance for reporting clinical prediction models that use regression or machine learning methods

Gary S. Collins, Karel G. M. Moons, Paula Dhiman, Richard D. Riley, Andrew L. Beam, Ben Van Calster

The update to TRIPOD set out twenty-seven reporting items for studies that develop or evaluate clinical prediction models, using either regression or machine learning. It explained the individual items and included a checklist for abstracts, covering details of data, modeling, evaluation, and open materials.

SignificanceThe update superseded the 2015 TRIPOD checklist and aligned reporting across modeling families. EQUATOR lists it for prediction model studies, where the common structure makes it easier to find evidence about development, performance evaluation, and potential transfer to another setting.

Key2024Nature Methods368 citations

Understanding metric-related pitfalls in image analysis validation

Annika Reinke, Minu D. Tizabi, Michael Baumgartner, Matthias Eisenmann, Doreen Heckmann-Nötzel, A. Emre Kavur

An international consortium used Delphi consultation and community feedback to catalog pitfalls in image analysis evaluation. Illustrated examples show how object size, matching rules, empty references, and aggregation across cases affect reported scores. The authors organized the pitfalls by where they arise in evaluation.

SignificanceThe catalog complements the companion selection framework by giving worked cases in which an apparently appropriate metric behaves poorly. Those examples help readers audit what an implementation or aggregation rule is measuring and recognize the conditions in which scores can be misleading.

Notable2025Nature Communications235 citations

A clinical benchmark of public self-supervised pathology foundation models

Gabriele Campanella, Shengjia Chen, Manbir Singh, Ruchika Verma, Silke Muehlstedt, Jennifer Zeng

Using routine-care slides from three medical centers, the study held public self-supervised tile encoders fixed and trained slide aggregators under a common protocol. It compared their features on tasks including cancer diagnosis and biomarker prediction, and made the automated benchmarking pipeline available for external use.

SignificanceApplying one evaluation protocol across models made comparisons possible on consistent clinical tasks, using material from several institutions and scanner vendors. The benchmark provides evidence for selecting a feature extractor by task and gives other researchers a way to compare subsequent models.

Notable2025FDA draft guidance, January 2025

Artificial Intelligence-Enabled Device Software Functions: Lifecycle Management and Marketing Submission Recommendations

U.S. Food and Drug Administration

In January 2025 the FDA issued draft recommendations on the total product lifecycle of device software with learned functions. The draft discusses data and development documentation, validation, user-facing information, and risk management. It proposes ways for submissions to describe post-market performance monitoring.

SignificanceThe draft documents the agency's proposed approach to maintaining evidence about real-world performance after authorization. It complements the final guidance on planned changes by describing how ongoing monitoring and other lifecycle information might be considered in a marketing submission.

Notable2025Scientific Reports10 citations

Clinical evaluation of medical image synthesis: a case study in wireless capsule endoscopy

Panagiota Gatoula, Dimitrios E. Diamantis, Anastasios Koulaouzidis, Cristina Carretero, Stefania Chetcuti-Zammit, Pablo Cortegoso Valdivia

The CEMIS protocol was tested on capsule endoscopy images generated with the TIDE-II variational autoencoder. Ten specialists judged single images, pairs, and groups for realism, diversity, or clinical features. In a paired task they identified real images more often than chance, while separate tasks used both real and synthetic images to assess abnormality recognition.

SignificanceThe case study makes clinical reader assessment of synthetic images reproducible across individual, paired, and grouped tasks. The real-image comparator for abnormality judgments gives readers a way to assess preservation of diagnostic features separately from judging whether an image looks authentic.

Key2025Nature Medicine330 citations

Collaboration between clinicians and vision–language models in radiology report generation

Ryutaro Tanno, David G. T. Barrett, Andrew Sellergren, Sumedh Ghaisas, Sumanth Dathathri, Abigail See

The authors trained Flamingo-CXR to generate chest radiograph reports and convened a radiologist panel to review model and clinician reports retrospectively. For inpatient and outpatient radiographs, clinically significant errors occurred in both reports in 24.8% of cases, only the generated report in 22.8%, and only the clinician report in 14.0%.

SignificanceThe error review also supplied edits for a retrospective proof of concept. Radiologists’ corrections were incorporated into model drafts, and raters compared the edited reports with the original clinical reports. Janus-Pro-CXR subsequently examined report quality and time in a prospective workflow study.

Key2025BMJ1,422 citations

FUTURE-AI: international consensus guideline for trustworthy and deployable artificial intelligence in healthcare

Karim Lekadir, Alejandro F. Frangi, Antonio R. Porras, Ben Glocker, Celia Cintas, Curtis P. Langlotz

The international consortium agreed on thirty recommendations spanning fairness, universality, traceability, usability, robustness, and explainability. They cover design, development, validation, deployment, and monitoring. Examples illustrate how different healthcare applications can translate the common set of recommendations into concrete evaluation and oversight practices.

SignificanceThe guidance brought testing across populations, user needs, and post-deployment monitoring into a common lifecycle framework. A subsequent medical imaging methods review used its principles to organize techniques available for operationalizing the recommendations in imaging research and deployment.

Notable2025IMDRF technical document N88

Good machine learning practice for medical device development: Guiding principles

International Medical Device Regulators Forum

The IMDRF document sets out ten good machine learning practice principles for developing medical devices. They address representative data, independent training and test sets, performance in clinically relevant conditions, information for users, monitoring deployed models, and evaluating the performance of the human-system team.

SignificanceThe document provides shared technical language for regulators and developers, continuing principles previously issued by national regulators. Its lifecycle framing ties deployed model monitoring to the evidence used in design and validation, including how the device is expected to be used.

Key2025Nature Medicine286 citations

GPT-4 assistance for improvement of physician performance on patient care tasks: a randomized controlled trial

Ethan Goh, Robert J. Gallo, Eric Strong, Yingjie Weng, Hannah Kerman, Jason A. Freed

The trial randomized 92 practicing physicians to use GPT-4 with conventional resources or conventional resources alone for five simulated patient-management cases. Investigators scored choices about testing, treatment, and follow-up. Access to GPT-4 improved management reasoning scores, while participants spent more time per case.

SignificanceThe study measured the effect of a language model on clinician management decisions alongside time spent on the task. Together with the earlier diagnostic trial, it supplied separate evidence on collaboration for two different types of clinical reasoning.

Key2025arXiv

HealthBench: Evaluating Large Language Models Towards Improved Human Health

Rahul K. Arora, Jason Wei, Rebecca Soskin Hicks, Preston Bowman, Joaquin Quiñonero-Candela, Foivos Tsimpourlas

HealthBench assembled 5,000 simulated health conversations, including both single-turn and multi-turn examples. A group of 262 physicians contributed case-specific criteria for assessing answers on dimensions including accuracy, completeness, and communication. A subset of consensus criteria was used to test agreement between automated scores and physician ratings.

SignificanceCase-specific criteria made open-ended health answers comparable along clinically defined dimensions. HealthBench Consensus retains criteria that multiple physicians agreed applied to the example and provides physician judgments for checking the automated grader. An independent study used a HealthBench sample alongside real clinician queries.

Notable2025Nature Communications35 citations

Knowledge-guided adaptation of pathology foundation models effectively improves cross-domain generalization and demographic fairness

Yanyan Huang, Weiqin Zhao, Zhengyu Zhang, Yihang Chen, Yu Fu, Feng Wu

FLEX used visual and textual prior knowledge to guide a task-specific bottleneck for adapting pathology foundation models. Across three cohorts, 16 tasks, and more than 9,900 slides, the study reported improved transfer to unseen cohorts and reductions in performance differences between demographic groups.

SignificanceThe study treated cross-site transfer and demographic subgroup performance as separately measurable outcomes of pathology model adaptation. Using three cohorts gave the authors a way to test both shifts in data origin and subgroup gaps across multiple downstream tasks.

Notable2025FDA final guidance, August 2025

Marketing Submission Recommendations for a Predetermined Change Control Plan for Artificial Intelligence-Enabled Device Software Functions

U.S. Food and Drug Administration

The FDA final guidance describes predetermined change control plans for eligible device software submitted through the 510(k), De Novo, and premarket approval pathways. It recommends describing the planned changes, the protocol for developing, validating, and implementing them, and an assessment of their impact.

SignificanceThe guidance explains how the FDA evaluates a change plan within a marketing submission. Once authorized, the plan can cover specified future changes, connecting those software updates to pre-established validation methods and impact assessments while preserving continued regulatory oversight.

Key2025NEJM AI320 citations

MedAgentBench: A Virtual EHR Environment to Benchmark Medical LLM Agents

Yixing Jiang, Kameron C. Black, Gloria Geng, Danny Park, James Zou … Jonathan H. Chen

MedAgentBench provided a FHIR-compliant virtual electronic health record environment containing 100 patient profiles and 300 clinician-written tasks. Agents called standard application interfaces to obtain or update data, and the benchmark evaluated whether the results or record changes specified by each task were completed correctly.

SignificanceThe benchmark made agent performance measurable through outcomes in a virtual record system. The published follow-up, MedAgentBench v2, used this setting to examine how variations in agent and interface design affect task completion, providing a direct extension of the initial evaluation.

Key2025NeurIPS 2025 (Datasets and Benchmarks)61 citations

MedAgentBoard: Benchmarking Multi-Agent Collaboration with Conventional Methods for Diverse Medical Tasks

Yinghao Zhu, Ziyi He, Haoran Hu, Xiaochen Zheng, Xichen Zhang, Zixiang Wang

MedAgentBoard compared multiple-agent systems, single language models, and conventional approaches on medical question answering, lay summaries, record-based prediction, and workflow automation. Multi-agent collaboration helped on some workflow tasks, while specialized methods often performed better on medical visual questions and electronic record prediction.

SignificanceThe benchmark made the advantage of agent collaboration an empirical question by including single-model and conventional baselines across different clinical tasks. HealthFlow used its workflow tasks to compare whether systems could produce complete and methodologically valid analysis artifacts.

Key2025Nature Medicine364 citations

Nationwide real-world implementation of AI for cancer detection in population-based mammography screening

Nora Eisemann, Stefan Bunk, Trasias Mukama, Hannah Baltus, Susanne A. Elsner, Timo Gomille

The PRAIM implementation study compared supported and standard double reading in an organized mammography screening program. It included 463,094 women at twelve German sites. Cancer detection was 6.7 versus 5.7 per 1,000 screened, and recall in the supported group met the study's noninferiority criterion.

SignificanceThe study documents large-scale use inside an established double-reading program. Radiologists chose whether to use the system, so the observational comparison complements randomized evidence by describing implementation in a different screening organization and reporting outcomes from routine practice.

Key2025The Lancet Digital Health263 citations

Screening performance and characteristics of breast cancer detected in the Mammography Screening with Artificial Intelligence trial (MASAI): a randomised, controlled, parallel-group, non-inferiority, single-blinded, screening accuracy study

Veronica Hernström, Viktoria Josefsson, Hanna Sartor, David Schmidt, Anna-Maria Larsson, Solveig Hofvind

The full screening cohort of MASAI was analyzed for cancers detected at the screening visit. Detection was 6.4 versus 5.0 per 1,000 participants for supported versus standard reading. The paper describes features of detected invasive cancers and in-situ disease and reports recall and false positives.

SignificanceThis analysis complements the early safety report by characterizing the additional cancers found at screening and reporting reading workload with the full cohort. The interval-cancer publication addresses a separate prespecified question requiring follow-up after the screening visit.

Key2025Nature Medicine630 citations

The STARD-AI reporting guideline for diagnostic accuracy studies using artificial intelligence

Viknesh Sounderajah, Ahmad Guni, Xiaoxuan Liu, Gary S. Collins, Alan Karthikesalingam, Sheraz R. Markar

The STARD extension was developed by international consensus for diagnostic accuracy studies using algorithmic tests. It expands reporting on the evaluated system and the data used to assess it, with attention to provenance, reference standards, performance evaluation, and the potential for bias in intended use.

SignificanceThe extension embeds information about algorithmic tests and their evaluation data within an established diagnostic accuracy framework. It gives imaging accuracy studies a common reporting structure for examining the tested system, case selection, and the meaning of reported performance.

Builds onBossuyt 2015

Key2025Nature Medicine3,155 citations

Toward expert-level medical question answering with large language models

Karan Singhal, Tao Tu, Juraj Gottweis, Rory Sayres, Ellery Wulczyn, Mohamed Amin

Med-PaLM 2 combined a stronger base model, medical adaptation, and strategies for aggregating candidate responses and retrieving evidence. It achieved up to 86.5% on the MedQA examination benchmark. Physicians also assessed longer answers to standard, adversarial, and real-world medical questions.

SignificanceThe study extended earlier question-answering comparisons with adversarial prompts and a specialist review of real consultation questions. Its separate measures for exam questions, longer responses, and different physician groups made it possible to identify where gains generalized and where they depended on the comparison.

Builds onSinghal 2023

Key2026npj Digital Medicine412 citations

AgentClinic: a multimodal benchmark for tool-using clinical AI agents

Samuel Schmidgall, Rojin Ziaei, Carl Harris, Ji Woong Kim, Eduardo Pontes Reis … Michael Moor

AgentClinic converted MedQA questions, MIMIC-IV records, and New England Journal of Medicine case challenges into simulated encounters. Models could request histories, test results, or images during the encounter. The benchmark covered nine specialties and seven languages and reported substantial accuracy drops for some models when static questions became sequential decisions.

SignificanceAgentClinic made information seeking and tool use observable alongside final diagnosis. By reformulating familiar cases as interactive episodes, the benchmark allowed comparison between static question answering and sequential reasoning under incomplete information while holding parts of the underlying medical content fixed.

Builds onJin 2021

Notable2026FDA 510(k) K252970

BriefCase-Triage: CARE Multi-triage CT Body

Aidoc Medical, Ltd.

This software uses a locked algorithm fine-tuned from a foundation model. It processes contrast and noncontrast chest, abdominal, or pelvic CT for people aged 18 and older. It flags 11 specified suspected findings for trained readers to prioritize review of the original exam. The FDA cleared the device in January 2026.

SignificanceThe case shows how a pretrained foundation model can supply several specified triage functions in one device. The public clearance record specifies the scans, the listed findings, and the notification role, defining the scope of the application.

Notable2026Radiology: Artificial Intelligence0 citations

Checklist for Artificial Intelligence in Medical Imaging (CLAIM): Explanation, Elaboration, and Examples

Tugba Akinci D’Antonoli, Lisa C. Adams, Amine Amyar, Ken Chang, Gunvant Chaudhari, Salvatore Claudio Fanni

This companion explains all 44 items of the 2024 CLAIM update, including the rationale for each item, common misinterpretations, and how to apply it. An appendix and online tool illustrate the items with published studies across data sourcing, model development, testing, and reporting.

SignificanceThe examples make it easier for authors and reviewers to apply the checklist consistently to a manuscript. EQUATOR indexes the paper with the 2024 checklist, and the RSNA's interactive resource makes the accompanying explanations and examples accessible for each item.

Builds onTejani 2024

Notable2026npj Digital Medicine26 citations

ClinicRealm: Re-evaluating large language models with conventional machine learning for non-generative clinical prediction tasks

Yinghao Zhu, Junyi Gao, Zixiang Wang, Weibin Liao, Xiaochen Zheng, Lifang Liang

ClinicRealm compared 15 generative language models, five BERT-style models, and 11 conventional approaches on clinical prediction using notes and structured records. Model rankings varied by input and the amount of training data available, and zero-shot models were competitive in some data-scarce settings.

SignificanceThe benchmark made clinical prediction measurable independently of medical question answering, using conventional models and zero-shot methods as direct comparisons. Its separation of notes from structured records provided a reference for evaluating models under different input and training-data conditions.

Notable2026IMDRF technical document N90

Essential Principles and Content of Predetermined Change Control Plans

International Medical Device Regulators Forum

This final IMDRF technical document describes predetermined change control plans for medical device software. It organizes content around a description of intended changes, a plan for making and controlling those changes, and impact assessment. It connects documentation of software changes with safety and performance evidence.

SignificanceThe document gives regulators a common basis for discussing software changes specified in advance. Its structure allows comparison of proposed change scopes and verification plans across jurisdictions while leaving the handling of particular submissions to the applicable national framework.

Notable2026npj Digital Medicine2 citations

HealthFlow: automating electronic health record analysis via a strategically self-evolving multi-agent framework

Yinghao Zhu, Zixiang Wang, Yifan Qi, Lei Gu, Dehao Sui, Haoran Hu

HealthFlow turned prior electronic health record analyses into structured examples for planning new analyses under methodological and dataset-specific constraints. The authors introduced EHRFlowBench and evaluated the framework on that benchmark and four others, comparing completion and validity of the artifacts produced.

SignificanceThe study evaluated EHR agents on workflow artifacts that require coherent planning and execution across several steps. Reproducible checks of those artifacts can expose methodological errors that would be invisible in a benchmark scored only by the final short answer.

Key2026Nature Medicine283 citations

Holistic evaluation of large language models for medical tasks with MedHELM

Suhana Bedi, Hejie Cui, Miguel Fuentes, Alyssa Unell, Michael Wornow, Juan M. Banda

MedHELM organized clinical uses into a clinician-validated taxonomy of five categories and 121 tasks. It mapped 37 benchmarks to that taxonomy and used a common evaluation framework to compare nine language models on activities including decision support, documentation, communication, research, and administration.

SignificanceMedHELM provided a task taxonomy and an extensible implementation for comparisons beyond medical exams. Results organized by clinical task allow researchers to see which activities are underrepresented and how model rankings change across uses that require different kinds of output.

Notable2026Nature Medicine147 citations

LLM-assisted systematic review of large language models in clinical medicine

Sully F. Chen, Anton Alyakin, Andreas Seas, Eunice Yang, Joanne J. Choi, Jin Vivian Lee

The systematic review identified 4,609 peer-reviewed evaluations of large language models in clinical medicine between January 2022 and September 2025. Of those using real patient data, 19 were prospective randomized trials. Simulations and exam-style tasks accounted for much of the published evaluation landscape.

SignificanceThe review quantified how often published evaluations used routine clinical data, randomized trials, simulations, or examinations. It showed how the evidence base varied by study design and provided context for interpreting direct comparisons between language models and clinicians across tasks.

Notable2026Official Journal of the European Union, L 2026/1744

Regulation (EU) 2026/1744 of the European Parliament and of the Council of 8 July 2026 amending Regulations (EU) 2024/1689, (EU) 2018/1139 and (EU) 2023/1230 as regards the simplification of the implementation of harmonised rules on artificial intelligence (Digital Omnibus on AI) (Text with EEA relevance)

European Parliament and Council of the European Union

The Digital Omnibus amended provisions governing high-risk systems and the schedule for applying them. Under revised Article 113, the relevant rules for systems classified as high-risk under Article 6(1) and Annex I apply from August 2, 2028. The amending regulation entered into force on July 27, 2026.

SignificanceThe date is relevant to imaging software that falls under the medical device legislation in Annex I and satisfies the product-related high-risk conditions. The official amendment and consolidated text document the timing and the conditions to which it applies.

Builds onUnion 2024

Notable2026IEEE Transactions on Biomedical Engineering57 citations

Segment Anything Model 2: An Application to 2D and 3D Medical Images

Haoyu Dong, Hanxue Gu, Yaqian Chen, Jichen Yang, Yuwen Chen, Maciej A. Mazurowski

The authors evaluated 80 prompting strategies across 21 medical datasets, treating adjacent slices as video frames for volumetric segmentation. For three-dimensional targets, box prompts generally improved mask overlap over points, and propagating masks in both directions improved performance over one-way propagation. Two-dimensional performance was similar to the original SAM.

SignificanceThe earlier 19-dataset study tested prompts on individual images. The SAM 2 evaluation controlled where a volume was prompted and varied the direction of mask propagation. It gave researchers a way to measure what one annotated slice contributes to segmentation across a volume.

Builds onRavi 2025

Notable2026Journal of Imaging Informatics in Medicine0 citations

Toward Verifiable Medical Imaging World Models: An Engineering Framework for Evaluating Simulation Fidelity, Roll-Out Stability, and Clinical Plausibility

Chathura Wimalasiri

The paper proposes assessing imaging world models by simulation fidelity, stability across steps, and clinical plausibility, then audits a purposive sample of nine models. It proposes estimating the number of steps that remain within a stated clinical error tolerance under the observed pattern of actions.