MG·LB · Researchers

Alex Zwanenburg

Coordinated standard definitions and reference values for quantitative radiomics.

Computer-aided detection and radiomics ORCID OpenAlex

German Cancer Research Center

Key works · 3

Landmark2020Radiology4,893 citations

The Image Biomarker Standardization Initiative: Standardized Quantitative Radiomics for High-Throughput Image-based Phenotyping

Alex Zwanenburg, Martin Vallières … Aditya Apte

The initiative compared radiomics software on a shared digital phantom and a common CT image under predefined processing configurations. Participating teams agreed on reference feature values and then assessed reproducibility of standardized features in multimodal images from 51 patients with soft-tissue sarcoma.

SignificanceReference values made it possible to test independent software implementations against known inputs and settings. The public specifications provide formulas and benchmark results to support comparable feature computation before researchers evaluate the clinical validity of a radiomic model.

Key2023Insights into Imaging548 citations

CheckList for EvaluAtion of Radiomics research (CLEAR): a step-by-step reporting guideline for authors and reviewers endorsed by ESR and EuSoMII

Burak Kocak, Bettina Baessler … Lena Maier-Hein

An international expert group used a modified Delphi process to develop CLEAR, a 58-item checklist for reporting radiomics studies. It covers data and patient selection, image segmentation and feature extraction, modeling and validation, and disclosure of the availability of data, code, and models.

SignificanceCLEAR gave authors and reviewers a common set of disclosures for the design, validation, and availability of radiomics studies. The European Society of Radiology and the European Society of Medical Imaging Informatics endorsed it, and subsequent society practice recommendations specifically directed researchers to the checklist.

Key2024Radiology296 citations

The Image Biomarker Standardization Initiative: Standardized Convolutional Filters for Reproducible Radiomics and Enhanced Clinical Insights

Philip Whybra, Alex Zwanenburg … Alexandre Ayotte

Teams used digital phantoms and a chest CT image to establish reference filter-response images and derived feature values for eight types of convolutional filter. In validation with multimodality soft-tissue sarcoma images, 458 of 486 evaluated features met the study's reproducibility criterion across nine teams.

SignificanceThe benchmarks extended reference computation from feature definitions to the filtering step that precedes extraction. The initiative releases expected filter responses, feature values, and a compliance tool so researchers can check whether disagreement between implementations arises during filtering or during subsequent measurement.