MG·LB · Key works

Digital imaging, standards and PACS

In the exhibits6.1 Representation of digital images6.2 The sampling theorem and aliasing6.3 The Fourier transform and spatial frequency6.4 Convolution and filtering6.5 Noise, blur, and inverse problems7.1 The DICOM standard and PACS7.2 Digital radiographs and spiral CT

Landmark1822Firmin Didot, père et fils

Théorie analytique de la chaleur

Joseph Fourier

Fourier formulated heat conduction in solids using differential equations and expanded prescribed temperature distributions in trigonometric series. The components could be treated individually and then added, yielding temperature distributions over time for solid bodies with different shapes and boundary conditions.

SignificanceThe book developed a systematic method for representing distributions as frequency components and treating those components separately. The resulting tradition of Fourier analysis underlies spatial-frequency descriptions of digital images and the reconstruction of magnetic resonance images from encoded frequency data.

Landmark1928Transactions of the American Institute of Electrical Engineers4,215 citations

Certain Topics in Telegraph Transmission Theory

H. Nyquist

Nyquist analyzed distortion in telegraph lines in terms of their frequency response and derived conditions under which successive pulses would avoid interference at the decision instants. He related the required bandwidth to the signaling rate under ideal conditions and examined waveforms that could satisfy the constraints.

SignificanceThe work made the bandwidth constraint on telegraph signaling explicit and was an early source for later sampling theory. Related frequency limits are used in digital imaging to choose sample spacing and understand how unresolved spatial frequencies appear as aliasing.

Key1948Journal of the Optical Society of America1,056 citations

The Sensitivity Performance of the Human Eye on an Absolute Scale

Albert Rose

Rose used a detector limited by random photon fluctuations as a benchmark for human visual sensitivity. A television pickup experiment related target visibility to luminance, contrast, and angular size. Under the experimental model he estimated a threshold signal-to-noise ratio of about five.

SignificanceThe result became the Rose criterion used in image quality analysis. Medical physics texts use it as an approximate detectability benchmark for targets in noisy images, where visibility also depends on target size, background, and the viewing task.

Landmark1949Proceedings of the IRE9,337 citations

Communication in the Presence of Noise

Claude E. Shannon

Shannon represented messages and transmitted signals as points in function spaces and expressed a band-limited waveform in terms of uniformly spaced samples. The paper gave a construction for recovering the waveform from sufficiently close samples and analyzed achievable transmission rates in the presence of noise.

SignificanceThe sampling relationship provides a theoretical basis for the spatial spacing of digital image samples. Applying the same reasoning to spatial frequencies explains why detail beyond the range represented by the sampling grid can appear as spurious lower-frequency structure.

Key1956Australian Journal of Physics819 citations

Strip Integration in Radio Astronomy

R. N. Bracewell

Bracewell analyzed how scanning a radio source with a long, narrow telescope beam integrates the true distribution along strips. He related recoverable resolution to the beam profile and gave a method for reconstructing the source distribution from scans made at different orientations.

SignificanceThe paper gives an early application of the relationship between projections and spatial frequencies. The same relationship later explained how angular measurements provide the frequency information needed to recover a cross-sectional image in medical tomography.

Landmark19581957 Eastern Joint Computer Conference126 citations

Experiments in processing pictorial information with a digital computer

R. A. Kirsch, L. Cahn, C. Ray, G. H. Urban

The National Bureau of Standards team used a scanner to convert pictures to discrete samples and passed those values to the SEAC computer. They reported examples with photographs and printed patterns, showing how programmed operations could manipulate and analyze structure within digital images.

SignificanceThe work demonstrated a complete process from a physical picture to an array that a computer could manipulate. NIST identifies the 1957 scanning demonstration as a starting point for digital image processing, and medical image formats subsequently used discrete arrays for image storage.

Landmark1965Mathematics of Computation16,828 citations

An Algorithm for the Machine Calculation of Complex Fourier Series

James W. Cooley, John W. Tukey

Cooley and Tukey factored the calculation of a complex discrete Fourier transform into smaller transforms and reused intermediate results. For sample counts with suitable factors, the work grows approximately as the sample count times its logarithm, compared with quadratic work for direct summation.

SignificanceThis formulation helped popularize the fast Fourier transform, making repeated frequency-domain operations practical for large discrete arrays. Image filtering and MRI reconstruction from measured Fourier data are two applications in which the computational saving matters.

Landmark1971Proceedings of the National Academy of Sciences1,192 citations

Three-dimensional Reconstruction from Radiographs and Electron Micrographs: Application of Convolutions instead of Fourier Transforms

G. N. Ramachandran, A. V. Lakshminarayanan

The paper replaced direct two-dimensional Fourier computation in projection reconstruction with a one-dimensional convolution on each projection. The authors assembled the filtered data from different angles into sections and reported faster computation and greater accuracy in their tests using simulated projections.

SignificanceThe formulation made the filtering stage of CT reconstruction practical with a spatial-domain kernel. The IAEA handbook describes convolution followed by back-projection as a classical CT method and identifies the ramp filter by the authors' names, Ram–Lak.

Landmark1973British Journal of Radiology5,075 citations

Computerized transverse axial scanning (tomography): Part 1. Description of system

G. N. Hounsfield

Hounsfield described a head scanner that measured X-ray transmission through the same section at many angles. A computer estimated the attenuation of the individual elements of the section from those readings. The resulting images resolved differences between soft tissues with similar attenuation.

SignificanceThe EMI system put projection acquisition, numerical reconstruction, and section display into a scanner that could be used on patients. Hounsfield and Cormack shared the 1979 Nobel Prize in Physiology or Medicine for the development of computer-assisted tomography.

Key1982American Association of Physicists in Medicine57 citations

A Standard Format for Digital Image Exchange

Brent S. Baxter, Lewis E. Hitchner, Gerald Q. Maguire Jr.

The AAPM task force proposed a magnetic-tape interchange format in which multidimensional raster arrays are stored as sequential files. An opening directory records descriptive information in readable key-value pairs. The format worked within existing specifications for recorded magnetic tape and tape labels.

SignificanceThe report documents an early formal proposal for exchanging digital medical images across systems and treating image arrays and descriptive information as parts of the same interchange structure. The later DICOM specification also made this relationship explicit for networked imaging systems.

Key1982Proceedings of SPIE 31820 citations

Filmless Picture Archiving And Communication In Diagnostic Radiology

André J. Duerinckx, E. J. Pisa

The authors examined changes in digital acquisition and proposed a sequence of archiving and communication strategies from a research or teaching setting to broad clinical service. Their assessment compared levels of online storage and concluded that a system with partial online digital storage was feasible.

SignificancePresented at the first dedicated PACS meeting, the paper made filmless radiology concrete as a system of archiving and communication capabilities that could be introduced in stages. Later hospital-scale evaluations examined how these capabilities affected clinical access to images.

Landmark1983Radiology978 citations

Computed radiography utilizing scanning laser stimulated luminescence.

M. Sonoda, M. Takano, J. Miyahara, H. Kato

The Fuji system recorded a latent X-ray image on a storage phosphor plate. A laser subsequently scanned the plate and released light in proportion to the stored signal, which the reader converted to digital values. The plate could then be erased and reused.

SignificanceStorage plates made it possible to digitize projection radiographs while retaining cassette-based acquisition in existing rooms. Digital processing and archiving could therefore be introduced before flat-panel detectors were widely available. The IAEA handbook describes this technology as computed radiography.

Landmark1985ACR–NEMA Standards Publication No. 300-1985

Digital Imaging and Communications

American College of Radiology and National Electrical Manufacturers Association

The two sponsoring organizations specified a hardware interface, a minimum set of commands, and consistent data formats for transferring digital medical images. The specification addressed point-to-point communication and defined common technical requirements for sending images between devices made by different vendors.

SignificanceThis was the first published version in the standards lineage that became DICOM. It established common image data and communication conventions, continued through a 1988 revision, and was substantially reorganized to support network operation in DICOM in 1993.

Followed byAssociation 1993

Key1991Communications of the ACM4,452 citations

The JPEG still picture compression standard

Gregory K. Wallace

Wallace explained JPEG compression for continuous-tone still pictures, including lossy coding based on the discrete cosine transform and quantization and lossless coding based on prediction. He outlined the baseline coding steps in the 1991 ACM article and revisited them in the revised IEEE version published in 1992.

SignificanceThe article became an early reference for JPEG's coding modes and practical use. DICOM subsequently defined transfer syntaxes for encapsulating JPEG-compressed pixel data within medical image objects, allowing systems that support the same syntax to exchange those data.

Landmark1993NEMA Standards Publication PS3

Digital Imaging and Communications in Medicine (DICOM)

American College of Radiology and National Electrical Manufacturers Association

Version 3.0 organized medical images and associated information into defined objects, service classes, and message exchange rules. It specified encoding and network communication, giving applications a way to describe and negotiate the operations, objects, and transfer syntaxes they could support.

SignificanceThe standard supplied common definitions for exchanging images and clinical context among scanners, workstations, and archives. These definitions support multi-vendor PACS deployments, and subsequent parts and supplements extended the same framework to storage media and additional clinical objects.

Builds onAssociation 1985 Followed byJr. 1997

Key1995Medical Physics355 citations

X-ray imaging using amorphous selenium: Feasibility of a flat panel self-scanned detector for digital radiology

Wei Zhao, J. A. Rowlands

Zhao and Rowlands assessed a flat-panel concept that used amorphous selenium to convert X-rays directly to electrical charge and a thin-film transistor matrix to read out the resulting image. The analysis indicated feasibility for projection radiography, with electronic noise still limiting performance at typical fluoroscopic exposure rates.

SignificanceThe analysis set design requirements for a direct-conversion radiographic panel. The same team subsequently reported images of a hand phantom obtained with an operating prototype. Later clinical reports document use of amorphous-selenium flat panels for routine projection radiography.

Key1997Medical Physics120 citations

Empirical investigation of the signal performance of a high-resolution, indirect detection, active matrix flat-panel imager (AMFPI) for fluoroscopic and radiographic operation

L. E. Antonuk, Y. El-Mohri, J. H. Siewerdsen, J. Yorkston, W. Huang … R. A. Street

This study measured the behavior of a large-area active-matrix flat panel in radiographic and fluoroscopic modes. An intensifying screen converted X-rays to light, which a matrix of amorphous-silicon photodiodes and thin-film transistors read out. The authors characterized dark signals, temporal response, and sensitivity with different phosphor screens.

SignificanceThe measurements showed which signal and timing properties must be managed to use a single indirect panel for still radiographs and successive fluoroscopy frames. Scintillators coupled to amorphous-silicon readout arrays subsequently became a common flat-panel detector architecture.

Key1997Journal of the American Medical Informatics Association559 citations

Understanding and Using DICOM, the Data Interchange Standard for Biomedical Imaging

W. Dean Bidgood Jr., Steven C. Horii, Fred W. Prior, Donald E. Van Syckle

The authors explained DICOM information objects, services, and messages in terms of network image management, printing, procedure management, and offline media exchange. They also discussed conformance statements and how implementing the standard affected clinical users and practical system integration decisions.

SignificanceThis early reference explained how to evaluate what a vendor's DICOM conformance claim covers and why the supported service roles and transfer options matter for interoperability. The standard's continued use of conformance statements formalizes the disclosure of these implementation details.

Builds onAssociation 1993

Notable1999Radiology212 citations

Principles of Digital Radiography with Large-Area, Electronically Readable Detectors: A Review of the Basics

Harrell G. Chotas, James T. Dobbins III, Carl E. Ravin

The review compared large-area electronic X-ray detectors. It explained indirect conversion using a scintillator and light-sensitive elements, direct conversion using charge generated in a photoconductor, and how the detector array reads out the resulting signal. It also discussed implications for image quality.

SignificanceThe article documents the transition from systems requiring separate plate readout to electronically readable area detectors. Its distinction between direct and indirect conversion remains a framework used in medical physics teaching to explain how digital radiographic detectors collect signals.

Notable1999The British Journal of Radiology71 citations

The benefits of hospital-wide picture archiving and communication systems: a survey of clinical users of radiology services

S. Bryan, G. Weatherburn, J. Watkins, M. Buxton

The researchers surveyed clinical users before and after hospital-wide PACS implementation at Hammersmith Hospital and included several other hospitals for comparison. After deployment, users reported fewer problems obtaining images, and junior clinical staff reported spending less time searching for them.

SignificanceThis evaluation documented the shift from film handling to digital access through the experience of clinical staff. It used image availability and time spent searching as workflow measures, providing site-specific evidence about deployment beyond the technical ability to transmit images.

Key2001IEEE Signal Processing Magazine2,109 citations

The JPEG 2000 still image compression standard

Athanassios Skodras, Charilaos Christopoulos, Touradj Ebrahimi

The authors described the core JPEG 2000 standard, explaining image tiling, wavelet transformation, and entropy coding and comparing it with existing formats. They showed how its architecture supports lossless and lossy coding, progressive decoding, and priority for regions of interest.

SignificanceThe tutorial explains the options JPEG 2000 provides for different storage and transmission needs. DICOM subsequently defined JPEG 2000 transfer syntaxes for lossless-only and general use, enabling adoption by compatible medical archives and image communication systems.

Key2004Journal of Digital Imaging1,946 citations

OsiriX: An Open-Source Software for Navigating in Multidimensional DICOM Images

Antoine Rosset, Luca Spadola, Osman Ratib

The authors developed an open-source desktop application for navigating large DICOM image series, with multiplanar reformatting, volume rendering, and fusion of PET and CT. The system used ITK and VTK libraries for image processing and rendering and demonstrated navigation with multidimensional, multimodality studies.

SignificanceOsiriX combined DICOM communication and interactive volume display in an extensible open-source desktop application. Follow-up reports described its use for interpreting large PET/CT studies and an extension for sending and retrieving DICOM series between computers over a network.

Notable2007Journal of Digital Imaging209 citations

Increasing the Number of Gray Shades in Medical Display Systems—How Much is Enough?

Tom Kimpe, Tom Tuytschaever

The authors examined grayscale display using human luminance discrimination, the DICOM grayscale display function, and the characteristics of medical LCDs. Under the modeled conditions, increasing the panel's inherent bit depth from 11 to 12 bits yielded only a small improvement in calibration accuracy.

SignificanceThe study distinguished stored bit depth, display luminance levels, and perceptible gray shades. Bender and colleagues cited it in a study that measured just-noticeable luminance steps for 8-, 10-, and 11-bit lookup tables and asked radiologists to compare images displayed with the 8- and 11-bit tables.

Notable2019Journal of Digital Imaging25 citations

Implementation and Benefits of a Vendor-Neutral Archive and Enterprise-Imaging Management System in an Integrated Delivery Network

Chen Sirota-Cohen, Beverly Rosipko, Daniel Forsberg, Jeffrey L. Sunshine

A regional health network in northeast Ohio migrated multiple archives to a central vendor-neutral repository serving 54 radiology and 26 cardiology sites. Compared with preimplementation baselines, the authors reported about 30 percent lower storage costs per unit of capacity and about 80 percent fewer unscheduled outages.

SignificanceThe case shows how an enterprise archive extended beyond departmental PACS by making both DICOM and non-DICOM material accessible across specialties. The network also documented that the centralized system handled considerably more retrievals after implementation.

Key2020Journal of Digital Imaging20 citations

Interoperability and Considerations for Standards-Based Exchange of Medical Images: HIMSS-SIIM Collaborative White Paper

Kenneth R. Persons, Jason Nagels, Chris Carr, David S. Mendelson, Henri “Rik” Primo … Matthew Doyle

The white paper compared image exchange projects in Ontario, Austria’s electronic health record program, and the US RSNA Image Share Network, covering image discovery, retrieval, and access governance. It contrasted two Ontario repositories that used DICOM queries and an XDS registry, respectively, to discover examinations from outside sites.

SignificanceThe cases show what standards-based exchange required in practice, including matching patients across organizations, defining access, and retrieving outside examinations into local systems. A subsequent HIMSS–SIIM retrospective cited the paper in its discussion of interorganizational image sharing.