MG·LB · Key works

3D visualization

In the exhibits6.6 3D visualization: MPR, MIP and volume rendering7.4 3D reconstruction and visualization

Key1977Journal of Computer Assisted Tomography155 citations

Display of Three-Dimensional Information in Computed Tomography

G. T. Herman, H. K. Liu

The authors assembled transverse CT slices into a three-dimensional array and developed software to display a section through that array in an arbitrary orientation. They also demonstrated how to detect an organ boundary and display the isolated structure as a surface.

SignificanceThe study showed that one CT volume could be resampled outside the acquired orientation and also used to depict an organ surface. Both capabilities became functions of subsequent medical workstations for multiplanar reformatting and surface display.

Key1979Computer Graphics and Image Processing468 citations

Three-dimensional display of human organs from computed tomograms

Gabor T. Herman, Hsun Kao Liu

The authors approximated organ surfaces from CT with small square faces of restricted orientation and adapted a depth buffer to remove hidden surfaces efficiently. They applied low-pass filtering to reduce artifacts from the square approximation and demonstrated the method with actual patient-derived organ volumes.

SignificanceThe work showed that voxel boundaries could be rendered as visible faces for three-dimensional inspection of organs imaged by CT. Drebin and colleagues later described this square-face model when comparing existing surface methods with direct volume rendering.

Key1984Radiology497 citations

Three dimensional CT reconstruction images for craniofacial surgical planning and evaluation

M. W. Vannier, J. L. Marsh, J. O. Warren

The authors reconstructed three-dimensional bone and soft tissue surfaces from high-resolution CT contours and adapted computer-aided design methods to complex craniofacial cases. They showed how those surfaces could delineate abnormal anatomy, support surgical planning, and assist quantitative evaluation after surgery.

SignificanceThe work brought CT-derived surface models into preoperative and postoperative craniofacial assessment. Follow-up studies showed how clinicians could view skull reconstructions from different directions and selectively hide structures to inspect anatomical relationships obscured in an external view.

Landmark1987SIGGRAPH 198712,195 citations

Marching cubes: A high resolution 3D surface construction algorithm

William E. Lorensen, Harvey E. Cline

The algorithm visits cells of eight neighboring samples, selects a triangle configuration according to the samples' relationship to an isovalue, and interpolates vertex positions along cell edges. The authors used local gradients for shading and demonstrated the resulting surfaces with CT, MRI, and SPECT data.

SignificanceThe case table and interpolation made isosurface extraction a practical cell-by-cell operation that produced triangular meshes from medical volumes. The Visualization Toolkit later made the method available as a reusable component for extracting surfaces from volume data.

Landmark1988IEEE Computer Graphics and Applications2,732 citations

Display of surfaces from volume data

Marc Levoy

Levoy computed voxel shading from local gradients and separately assigned opacity according to a surface classification rule. Combining the shaded samples along each viewing ray produced a surface depiction directly from a three-dimensional array, with examples drawn from medical and molecular data.

SignificanceSeparating shading, classification, and ray compositing gave visualization systems a way to adjust the displayed structures while rendering directly from sampled volumes. Later acceleration work retained voxel classification and compositing while reducing the time required to generate each view.

Followed byLacroute 1994

Landmark1988ACM SIGGRAPH Computer Graphics1,806 citations

Volume rendering

Robert A. Drebin, Loren Carpenter, Pat Hanrahan

The authors assigned different optical and color properties to materials and their boundaries and computed images by simulating absorption along view rays. The procedures addressed aliasing and quantization artifacts, and the paper illustrated the rendering method on several kinds of volumetric data, including medical images.

SignificanceThis approach made it possible to show several structures and their occlusion relationships from one volume, with optical properties controlling which materials were emphasized. Clinical CT angiography later used related volume-rendering methods to depict vessels alongside relevant surrounding anatomy.

Key1989IEEE Transactions on Medical Imaging198 citations

Three-dimensional display in nuclear medicine

J. W. Wallis, T. R. Miller, C. A. Lerner, E. C. Kleerup

The investigators compared several surface and volume display techniques for nuclear medicine data, including maximum-activity projection, which keeps the highest activity along each viewing ray. Scintigraphic examples illustrated how the different projections represented focal uptake and spatial relationships in the volume.

SignificanceMaximum-activity projection made prominent foci in a volume visible in a single projection. The same maximum-value operation became a display option for CT angiography, where it highlights structures with high attenuation, including vessels opacified with contrast material.

Key1990Journal of Digital Imaging271 citations

Real time volumetric ultrasound imaging system

Olaf T. von Ramm, Stephen W. Smith

The authors used a 289-element two-dimensional phased array to scan a pyramidal volume with pulse echoes. Parallel processing on reception produced approximately eight volume acquisitions per second and also let the system display sections selected from the acquired three-dimensional data.

SignificanceThe prototype combined a two-dimensional array, parallel reception, and section display from acquired volumes to show how rapidly changing anatomy could be scanned in three dimensions. Later real-time three-dimensional echocardiography developed this approach using matrix-array transducers.

Landmark1990Radiology1,159 citations

Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation

W. A. Kalender, W. Seissler, E. Klotz, P. Vock

The investigators combined continuous gantry rotation with controlled continuous table motion, producing a helical acquisition. They interpolated the measurements to reconstruct sections at positions chosen after scanning. Clinical examples included lung nodules and contrast-enhanced studies acquired with single-breath-hold volume coverage.

SignificanceHelical acquisition made it possible to cover an organ continuously in one breath hold and choose reconstruction levels afterward. Subsequent multidetector systems retained helical sampling while increasing the volume covered per gantry rotation and the speed of each examination.

Followed byHu 2000

Key1994SIGGRAPH 19941,159 citations

Fast volume rendering using a shear-warp factorization of the viewing transformation

Philippe Lacroute, Marc Levoy

The authors factored the viewing transformation into a three-dimensional shear aligned with the data slices and a two-dimensional warp of an intermediate projection. Traversing the volume and intermediate image in synchrony, with run-length encoding to skip regions, accelerated rendering on contemporary workstations.

SignificanceAligning voxel rows with intermediate image rows reduced the work needed to generate a new view. A subsequent parallel implementation retained the factorization and increased the rate at which medical volumes could be rendered for interactive inspection.

Builds onLevoy 1988

Landmark1996IEEE Visualization 1996218 citations

The design and implementation of an object-oriented toolkit for 3D graphics and visualization

William J. Schroeder, Kenneth M. Martin, William E. Lorensen

The authors described the freely available C++ Visualization Toolkit, including its data representations, object model, execution synchronization, and bindings for interpreted languages. They demonstrated how common software components could be assembled into workflows for visualizing scalar, vector, and tensor data.

SignificanceVTK made three-dimensional processing and display algorithms reusable across applications. Medical software such as OsiriX used it for rendering, and IEEE VIS recognized the paper's enduring contribution with a Test of Time Award in 2021.

Landmark1996Journal of the American Medical Informatics Association779 citations

The Visible Human Male: A Technical Report

V. Spitzer, M. J. Ackerman, A. L. Scherzinger, D. Whitlock

The report documented how the National Library of Medicine's Visible Human Male data were produced. MRI, CT, and photographs of serial cryosections were acquired from the same cadaver. The authors described specimen selection, image production, and the resulting collection of about 15 gigabytes.

SignificanceImaging and physical sections from the same specimen provided a common reference for volumetric anatomy. The National Library of Medicine documents reuse of Visible Human data for anatomical teaching resources, three-dimensional reconstruction, and research on processing medical images.

Key1999The New England Journal of Medicine814 citations

A Comparison of Virtual and Conventional Colonoscopy for the Detection of Colorectal Polyps

Helen M. Fenlon, David P. Nunes, Paul C. Schroy III, Matthew A. Barish, Peter D. Clarke, Joseph T. Ferrucci

In a prospective study of 100 patients at high risk of colorectal neoplasia, the investigators reconstructed endoluminal views from helical CT and compared the findings with conventional colonoscopy in the same patients. The virtual examination detected a greater proportion of larger polyps than of smaller ones.

SignificanceComparing CT endoluminal display with conventional colonoscopy in the same patients moved virtual endoscopy from feasibility testing to clinical assessment by lesion size. Subsequent research extended the evaluation from a high-risk study population to asymptomatic people undergoing screening.

Key1999Proceedings of the National Academy of Sciences1,948 citations

Tracking neuronal fiber pathways in the living human brain

T. E. Conturo, N. F. Lori, T. S. Cull, E. Akbudak, A. Z. Snyder, J. S. Shimony

The authors estimated the direction of fastest water diffusion in living human brains and followed these directions step by step from seed points. They selected paths connecting defined brain regions and demonstrated trajectories in the corpus callosum, visual projections, and subcortical association pathways.

SignificanceThis was an early demonstration of deriving spatial models of human white matter pathways from local diffusion directions and selecting them using anatomical or functional regions. It made it possible to use in vivo diffusion data to examine candidate connections between specified brain areas.

Key2002IEEE Visualization 2002214 citations

CPR - Curved Planar Reformation

Armin Kanitsar, Dominik Fleischmann, Rainer Wegenkittl, Petr Felkel, Meister Eduard Gröller

The authors resampled CT volumes along a vessel centerline to display the lumen, wall, and surrounding tissue of a curved vessel in one image. They compared three reformations using a scanned tube phantom and presented thick, rotating, and multipath variants.

SignificanceThe study made explicit how curved reformations display long vessel segments within a single view and how the chosen method changes the representation of length, orientation, and branches. A subsequent paper extended multipath reformation to display an entire vascular tree.

Key2003The New England Journal of Medicine2,123 citations

Computed Tomographic Virtual Colonoscopy to Screen for Colorectal Neoplasia in Asymptomatic Adults

Perry J. Pickhardt, J. Richard Choi, Inku Hwang, James A. Butler, Michael L. Puckett, Hans A. Hildebrandt

The researchers examined 1,233 asymptomatic adults with virtual and optical colonoscopy on the same day. CT readers initially searched a three-dimensional endoluminal display for polyps. With final optical findings after segmental unblinding as the reference, CT colonography had a per-patient sensitivity of 93.8% for adenomatous polyps at least 10 mm in diameter.

SignificanceThe study provided screening data for CT colonography using a primary three-dimensional reading method in asymptomatic adults. Later multicenter validation also studied performance by lesion size, providing independent evidence for assessing the technique's use in screening.

Key2004Journal of Digital Imaging1,946 citations

OsiriX: An Open-Source Software for Navigating in Multidimensional DICOM Images

Antoine Rosset, Luca Spadola, Osman Ratib

The authors developed an open-source desktop application for navigating large DICOM image series, with multiplanar reformatting, volume rendering, and fusion of PET and CT. The system used ITK and VTK libraries for image processing and rendering and demonstrated navigation with multidimensional, multimodality studies.

SignificanceOsiriX combined DICOM communication and interactive volume display in an extensible open-source desktop application. Follow-up reports described its use for interpreting large PET/CT studies and an extension for sending and retrieving DICOM series between computers over a network.

Key2006RadioGraphics396 citations

Volume Rendering versus Maximum Intensity Projection in CT Angiography: What Works Best, When, and Why

Elliot K. Fishman, Derek R. Ney, David G. Heath, Frank M. Corl, Karen M. Horton, Pamela T. Johnson

The authors compared maximum intensity projection and volume rendering for CT angiography. Clinical images illustrated what each display preserves and how superimposed structures or rendering choices can affect interpretation. They related the strengths and limitations of the displays to specific clinical tasks.

SignificanceThe review connected algorithmic differences to clinical decisions about displaying CT angiograms. It offered a reference for postprocessing multidetector CT volumes, distinguishing tasks that benefit from emphasizing high-attenuation vessels from those that require surrounding anatomy and depth cues.

Landmark2012Magnetic Resonance Imaging10,484 citations

3D Slicer as an image computing platform for the Quantitative Imaging Network

Andriy Fedorov, Reinhard Beichel, Jayashree Kalpathy-Cramer, Julien Finet, Jean-Christophe Fillion-Robin, Sonia Pujol

The paper described 3D Slicer's architecture for extensions and its common facilities for image input, visualization, registration, and segmentation. Examples from the Quantitative Imaging Network showed how research teams used the platform for cancer imaging and distributed study-specific tools through it.

SignificanceThe platform made it possible to distribute new algorithms as modules with shared visualization and medical-image infrastructure. The 3D Slicer documentation identifies this work as a platform citation, giving studies that use it a common reference for the software architecture.

Key2017American Journal of Roentgenology243 citations

Cinematic Rendering in CT: A Novel, Lifelike 3D Visualization Technique

Marwen Eid, Carlo N. De Cecco, John W. Nance Jr., Damiano Caruso, Moritz H. Albrecht, Adam J. Spandorfer

The article explained how cinematic rendering applies global illumination to CT volumes by modeling light propagation, absorption, and scattering. Side-by-side images of an intracranial aneurysm and an aortic stent illustrated how shading changes the cues to the depth and shape of anatomical structures.

SignificanceThe pictorial review provided an early reference for applying global illumination to clinical CT display. Brookmeyer and colleagues cited the article in their 2024 review of implementation, which described how cinematic rendering fits into postprocessing and preprocedural planning.

Key2018CVPR 2018904 citations

PU-Net: Point Cloud Upsampling Network

Lequan Yu, Xianzhi Li, Chi-Wing Fu, Daniel Cohen-Or, Pheng-Ann Heng

PU-Net extracted multiscale features from patches of a sparse point cloud, expanded the features through several branches, and decoded them into a denser set of coordinates. Experiments on synthetic and scanned data found that generated points were more uniformly distributed and closer to the reference surfaces than the baselines.

SignificancePU-Net established a learned point-set baseline for adding samples to an observed surface. The subsequent EC-Net study extended this line of work by incorporating distances to surface edges, explicitly evaluating what happens to sharp features as the point set is densified.

Key2019ICCV 2019951 citations

PointFlow: 3D Point Cloud Generation with Continuous Normalizing Flows

Guandao Yang, Xun Huang, Zekun Hao, Ming-Yu Liu, Serge Belongie, Bharath Hariharan

PointFlow used continuous normalizing flows at two levels, one for shapes and one for point locations conditioned on a shape. A sampled shape could therefore be represented by an arbitrary number of points. Experiments compared shape generation, point-cloud reconstruction, and unsupervised representation learning.

SignificancePointFlow supplied a reproducible probabilistic baseline for sampling a continuous representation of point clouds. Luo and Hu compared their later point-cloud diffusion model against it on shape categories shared across the two studies, reporting metrics for generation and reconstruction.

Key2021CVPR 20211,220 citations

Diffusion Probabilistic Models for 3D Point Cloud Generation

Shitong Luo, Wei Hu

The authors learned to reverse diffusion on three-dimensional point coordinates, conditioning the reverse steps on a latent representation of object shape. The study evaluated generation and reconstruction on ShapeNet and tested representations learned without labels on separate point-cloud classification datasets.

SignificanceThe study adapted denoising diffusion to unordered spatial samples and compared it with existing probabilistic 3D generators including PointFlow. Subsequent work on medical volume synthesis cited it as an example of extending diffusion beyond conventional two-dimensional images.

Builds onHo 2020

Notable2025Computerized Medical Imaging and Graphics10 citations

3D cardiac shape analysis with variational point cloud autoencoders for myocardial infarction prediction and virtual heart synthesis

Marcel Beetz, Abhirup Banerjee, Lei Li, Julià Camps, Blanca Rodríguez, Vicente Grau

A variational point-cloud autoencoder learned three-dimensional cardiac shape variation using data from more than 10,000 subjects. In the study cohort, regression on the latent variables achieved higher AUROC than clinical biomarker baselines, including ejection fraction, for detecting prevalent and predicting incident myocardial infarction. The authors also used generated hearts in electrophysiology simulations.

SignificanceThe study demonstrated a concrete use of medical shape generation in building populations of virtual hearts for computational experiments. By running electrophysiology simulations on generated geometries, it evaluated a downstream use beyond geometric similarity to the training point clouds.

Notable2026MICCAI 2026 (LNCS 16893)12 citations

SAW: Toward a Surgical Action World Model via Controllable and Scalable Video Generation

Sampath Rapuri, Lalithkumar Seenivasan, Dominik Schneider, Roger Soberanis-Mukul, Yufan He, Hao Ding

SAW uses video diffusion to generate laparoscopic clips given a starting scene, text, a tissue affordance mask, and a tool-tip trajectory. When synthetic clips were added to training, one spatiotemporal convolutional network improved its recognition of clipping and cutting on held-out real footage.

SignificanceAction recognition on real test clips measures one use for the synthetic footage. A separate experiment supplied simulator-derived trajectories to evaluate visual rendering from specified tool movements, such as the appearance of the tool and nearby tissue over time.